: SZARR190307012-01
Test Report
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 2 of 11
Test Method:
A. XRF Screening Test
XRF screening limits in mg/kg for regulated elements according to IEC 62321-3-1:2013.
Limit of IEC 62321-3-1:2013 Unit (mg/kg)
Element
Polymers Metals Composite material
Cd BL≤(70-3σ)<X <(130+3σ)≤OL BL≤(70-3σ) <X <(130+3σ)≤OL LOD<X <(150+3σ)≤OL
BL≤(700-3σ) <X BL≤(700-3σ) <X BL≤(500-3σ)<X
Pb
<(1300+3σ)≤OL <(1300+3σ)≤OL <(1500+3σ)≤OL
BL≤(700-3σ)<X BL≤(700-3σ)<X BL≤(500-3σ)<X
Hg
<(1300+3σ)≤OL <(1300+3σ)≤OL <(1500+3σ)≤OL
Br BL≤(300-3σ)< X N.A. BL≤(250-3σ)< X
Cr BL≤(700-3σ)< X BL≤(700-3σ)< X BL≤(500-3σ)< X
Note:
-N.A. = Not Applicable
-BL = Under the XRF screening limit
-OL = Further chemical test will be conducted while result is above the screening limit
-X= The symbol “X” marks the region where further investigation is necessary
-3σ= The reproducibility of analytical instruments
-LOD= Detection limit
B. Chemical Test
Measured
Test Item(s) Test Method MDL Limit
Equipment(s)
Lead (Pb) IEC 62321-5:2013 2 mg/kg 1000 mg/kg
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 3 of 11
Test Results:
Sample Sample Chemical Test
Tested Items XRF Screening Test Conclusion
No. Description Unit (mg/kg)
Pb BL /
Cd BL /
Hg BL /
Cr(Cr(VI) ) BL /
Silvery metal
1 Br(PBBs&PBDEs) N.A. / PASS
spring
DBP N.A. /
BBP N.A. /
DEHP N.A. /
DIBP N.A. /
Pb BL /
Cd LOD /
Hg BL /
Cr(Cr(VI) ) BL /
2 Chip capacitor Br(PBBs&PBDEs) BL / PASS
DBP N.A. N.D.
BBP N.A. N.D.
DEHP N.A. N.D.
DIBP N.A. N.D.
Pb BL /
Cd BL /
Hg BL /
Cr(Cr(VI) ) BL /
3 Crystal oscillator Br(PBBs&PBDEs) N.A. / PASS
DBP N.A. /
BBP N.A. /
DEHP N.A. /
DIBP N.A. /
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 4 of 11
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 5 of 11
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 6 of 11
Note:
- The screening results are only used for reference.
- When conducting the test for PBBs&PBDEs, XRF was introduced to screen Br Exclusively; When
conducting the test for Hexavalent Chromium, XRF was introduced to screen Chromium exclusively.
-BL = Under the XRF screening limit
-OL = Further chemical test will be conducted while result is above the screening limit
-X= The symbol “X” marks the region where further investigation is necessary
-LOD= Detection limit
-MDL = Method Detection Limit
-N.A. = Not Applicable
-N.D. = Not Detected (<MDL)
-/=Not tested
-mg/kg = ppm = parts per million
- μg/cm2 = microgramme per square centimetre
-Negative = Absence of Cr(VI) , the detected Cr(VI) concentration in the boiling water extraction solution is
less than 0.10ug/cm2.
-Positive = Presence of Cr(VI), the detected Cr(VI) concentration in the boiling water extraction solution is
equal to or greater than 0.13ug/cm2.
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 7 of 11
Test Process:
◆ IEC 62321-5:2013
Dry Ashing/
Alkali Fusion/ Residue
Analyzed Make up with Acid Dissolution
by deionized Filtration
ICP-OES water
Solution
◆ IEC 62321-4:2013+AMD1:2017
Alkali Fusion/
Residue
Acid Dissolution
Analyzed Make up with
by deionized Filtration
ICP-OES water
Solution
◆ IEC 62321-7-1:2015
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 8 of 11
◆ IEC 62321-7-2:2017
Weigh sample
Add digestion Heat at 90-95℃for
Cr(VI) and place it in a
reagent 3 hours
conical flask
◆ IEC 62321-6:2015
Weigh sample
Extracted with Concentrate the
PBBs/ PBDEs and place it in a
organic solvent extract
thimble
◆ IEC 62321-8:2017
Weigh sample
Extracted with Concentrate the
Phthalate and place it in a
organic solvent extract
thimble
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 9 of 11
Photograph of Sample
SZARR190307012-01
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 10 of 11
2 3
6
4 5
AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 11 of 11
9 10
AB-RHS-03-a