Report No.

: SZARR190307012-01

Test Report

GUANGZHOU HC INFORMATION TECHNOLOGY CO.,


Client Name :
LTD

ROOM 608 NUM.19 JIANGONG ROAD TIANHE


Address :
SOFTWARE PARK TIANHE DISTRICT GUANGZHOU

Product Name : RF Wireless Module

Date : Mar. 15, 2019

Shenzhen Anbotek Compliance Laboratory Limited


Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 1 of 11

Applicant : GUANGZHOU HC INFORMATION TECHNOLOGY CO., LTD


Address : ROOM 608 NUM.19 JIANGONG ROAD TIANHE SOFTWARE PARK
TIANHE DISTRICT GUANGZHOU
The submitted sample and sample information was/were submitted and identified by/on the behalf
of the client
Sample Name : RF Wireless Module
Model No. : HC-12
Manufacturer GUANGZHOU HC INFORMATION TECHNOLOGY CO., LTD
Sample Received Date : Mar. 07, 2019
Testing Period : Mar. 07, 2019 to Mar. 15, 2019

Test Requested : As specified by client, to test the Lead(Pb), Cadmium(Cd),


Mercury(Hg), Hexavalent Chromium(Cr(VI)), Polybrominated
Biphenyl(PBBs), Polybrominated Diphenyl Ethers (PBDEs), Diisobutyl
phthalate (DIBP), Dibutyl phthalate(DBP), Benzyl butyl
phthalate(BBP), Di-2-ethylhexyl phthalate(DEHP) in the submitted
sample in accordance with the RoHS Directive 2011/65/EU and
amendment Commission Delegated Directive (EU) 2015/863 with
effective from 22 July 2019.

Test Method: Please refer to the following page(s).

Test Result(s): Please refer to the following page(s).

Tested by Reviewed by Approved by


Liqing Yang Niki You Leo Li
Test engineer Test engineer Authorized signatory

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 2 of 11

Test Method:
A. XRF Screening Test
XRF screening limits in mg/kg for regulated elements according to IEC 62321-3-1:2013.
Limit of IEC 62321-3-1:2013 Unit (mg/kg)
Element
Polymers Metals Composite material
Cd BL≤(70-3σ)<X <(130+3σ)≤OL BL≤(70-3σ) <X <(130+3σ)≤OL LOD<X <(150+3σ)≤OL
BL≤(700-3σ) <X BL≤(700-3σ) <X BL≤(500-3σ)<X
Pb
<(1300+3σ)≤OL <(1300+3σ)≤OL <(1500+3σ)≤OL
BL≤(700-3σ)<X BL≤(700-3σ)<X BL≤(500-3σ)<X
Hg
<(1300+3σ)≤OL <(1300+3σ)≤OL <(1500+3σ)≤OL
Br BL≤(300-3σ)< X N.A. BL≤(250-3σ)< X
Cr BL≤(700-3σ)< X BL≤(700-3σ)< X BL≤(500-3σ)< X

Note:
-N.A. = Not Applicable
-BL = Under the XRF screening limit
-OL = Further chemical test will be conducted while result is above the screening limit
-X= The symbol “X” marks the region where further investigation is necessary
-3σ= The reproducibility of analytical instruments
-LOD= Detection limit

B. Chemical Test
Measured
Test Item(s) Test Method MDL Limit
Equipment(s)
Lead (Pb) IEC 62321-5:2013 2 mg/kg 1000 mg/kg

Cadmium (Cd) IEC 62321-5:2013 ICP-OES 2 mg/kg 100 mg/kg

Mercury (Hg) IEC 62321-4:2013+AMD1:2017 2 mg/kg 1000 mg/kg

IEC 62321-7-1:2015 0.10μg/cm2


Hexavalent Chromium Cr(VI) UV-VIS 1000 mg/kg
IEC 62321-7-2:2017 2 mg/kg
Polybrominated Biphenyls
IEC 62321-6:2015 5 mg/kg 1000 mg/kg
(PBBs)
Polybrominated Diphenyl
IEC 62321-6:2015 GC-MS 5 mg/kg 1000 mg/kg
Ethers (PBDEs)
Phthalates
IEC 62321-8:2017 50 mg/kg 1000 mg/kg
(DIBP, DBP, BBP, DEHP)

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 3 of 11

Test Results:
Sample Sample Chemical Test
Tested Items XRF Screening Test Conclusion
No. Description Unit (mg/kg)
Pb BL /
Cd BL /
Hg BL /
Cr(Cr(VI) ) BL /
Silvery metal
1 Br(PBBs&PBDEs) N.A. / PASS
spring
DBP N.A. /
BBP N.A. /
DEHP N.A. /
DIBP N.A. /
Pb BL /
Cd LOD /
Hg BL /
Cr(Cr(VI) ) BL /
2 Chip capacitor Br(PBBs&PBDEs) BL / PASS
DBP N.A. N.D.
BBP N.A. N.D.
DEHP N.A. N.D.
DIBP N.A. N.D.
Pb BL /
Cd BL /
Hg BL /
Cr(Cr(VI) ) BL /
3 Crystal oscillator Br(PBBs&PBDEs) N.A. / PASS
DBP N.A. /
BBP N.A. /
DEHP N.A. /
DIBP N.A. /

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 4 of 11

Sample Sample XRF Screening Test Chemical Test


Tested Items Conclusion
No. Description Unit (mg/kg) Unit (mg/kg)
Pb BL /
Cd BL /
Hg BL /
Cr(Cr(VI) ) BL /
Coppery metal
4 Br(PBBs&PBDEs) N.A. / PASS
joint
DBP N.A. /
BBP N.A. /
DEHP N.A. /
DIBP N.A. /
Pb BL /
Cd LOD /
Hg BL /
Cr(Cr(VI) ) BL /
5 Chip triode Br(PBBs&PBDEs) X N.D. PASS
DBP N.A. N.D.
BBP N.A. N.D.
DEHP N.A. N.D.
DIBP N.A. N.D.
Pb BL /
Cd LOD /
Hg BL /
Cr(Cr(VI) ) BL /
6 Chip diode Br(PBBs&PBDEs) BL / PASS
DBP N.A. N.D.
BBP N.A. N.D.
DEHP N.A. N.D.
DIBP N.A. N.D.

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 5 of 11

Sample Sample XRF Screening Test Chemical Test


Tested Items Conclusion
No. Description Unit (mg/kg) Unit (mg/kg)
Pb BL /
Cd LOD /
Hg BL /
Cr(Cr(VI) ) BL /
7 Blue PCB Br(PBBs&PBDEs) X N.D. PASS
DBP N.A. N.D.
BBP N.A. N.D.
DEHP N.A. N.D.
DIBP N.A. N.D.
Pb BL /
Cd BL /
Hg BL /
Cr(Cr(VI) ) BL /
8 Soldering tin Br(PBBs&PBDEs) N.A. / PASS
DBP N.A. /
BBP N.A. /
DEHP N.A. /
DIBP N.A. /
Pb BL /
Cd LOD /
Hg BL /
Cr(Cr(VI) ) BL /
9 Square IC(big) Br(PBBs&PBDEs) BL / PASS
DBP N.A. N.D.
BBP N.A. N.D.
DEHP N.A. N.D.
DIBP N.A. N.D.

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 6 of 11

Sample Sample XRF Screening Test Chemical Test


Tested Items Conclusion
No. Description Unit (mg/kg) Unit (mg/kg)
Pb BL /
Cd LOD /
Hg BL /
Cr(Cr(VI) ) BL /
Square
10 Br(PBBs&PBDEs) BL / PASS
IC(small)
DBP N.A. N.D.
BBP N.A. N.D.
DEHP N.A. N.D.
DIBP N.A. N.D.

Note:
- The screening results are only used for reference.
- When conducting the test for PBBs&PBDEs, XRF was introduced to screen Br Exclusively; When
conducting the test for Hexavalent Chromium, XRF was introduced to screen Chromium exclusively.
-BL = Under the XRF screening limit
-OL = Further chemical test will be conducted while result is above the screening limit
-X= The symbol “X” marks the region where further investigation is necessary
-LOD= Detection limit
-MDL = Method Detection Limit
-N.A. = Not Applicable
-N.D. = Not Detected (<MDL)
-/=Not tested
-mg/kg = ppm = parts per million
- μg/cm2 = microgramme per square centimetre
-Negative = Absence of Cr(VI) , the detected Cr(VI) concentration in the boiling water extraction solution is
less than 0.10ug/cm2.
-Positive = Presence of Cr(VI), the detected Cr(VI) concentration in the boiling water extraction solution is
equal to or greater than 0.13ug/cm2.

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 7 of 11

Test Process:

◆ IEC 62321-5:2013

Weigh the sample Add digestion Digest the


Pb/Cd reagent sample
into a vessel

Dry Ashing/
Alkali Fusion/ Residue
Analyzed Make up with Acid Dissolution

by deionized Filtration
ICP-OES water
Solution

◆ IEC 62321-4:2013+AMD1:2017

Weigh sample and Digest sample in


place it in a Add digestion microwave
Hg microwave digestion reagent digestion oven
vessel

Alkali Fusion/
Residue
Acid Dissolution
Analyzed Make up with
by deionized Filtration
ICP-OES water
Solution

◆ IEC 62321-7-1:2015

Take a portion of Extracted with Filter and remove


Cr(VI)
the sample boiling water the sample

Analyzed Adjust the pH value


Add test solution
by UV-Vis of the solution

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 8 of 11

◆ IEC 62321-7-2:2017

Weigh sample
Add digestion Heat at 90-95℃for
Cr(VI) and place it in a
reagent 3 hours
conical flask

Adjust the pH value Add test Adjust the pH value


Cool and filter
of the solution solution of the solution

Make up with Analyzed


deionized water by UV-Vis

◆ IEC 62321-6:2015

Weigh sample
Extracted with Concentrate the
PBBs/ PBDEs and place it in a
organic solvent extract
thimble

Analyzed Make up with Transfer the extract


by GC-MS organic solvent into a volumetric flask

◆ IEC 62321-8:2017

Weigh sample
Extracted with Concentrate the
Phthalate and place it in a
organic solvent extract
thimble

Analyzed Make up with Transfer the extract


by GC-MS organic solvent into a volumetric flask

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 9 of 11

Photograph of Sample

SZARR190307012-01

Photo(s) of the tested component(s)

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 10 of 11

2 3

6
4 5

AB-RHS-03-a
Test Report
Report No.: SZARR190307012-01 Date: Mar. 15, 2019 Page 11 of 11

9 10

***** End of Report *****