RoHS TEST REPORT

Report No. : NPS018050349-CE


Applicant : Xiamen Sunford Industry&Trade Co., Ltd.
Address : 6F NO 12,LONGSHENGLI,SIMING DISTRICT, XIAMEN CITY,CHINA
Manufacturer : Xiamen Sunford Industry&Trade Co., Ltd.
Address : 6F NO 12,LONGSHENGLI,SIMING DISTRICT, XIAMEN CITY,CHINA
Importer : N/A

Equipment Under Test (EUT)


Trade Name : N/A
Product Name : Fire Ball , Automatic Fire Extinguisher
Model No. : ACD1.3
Serial No. : ACD0.5、ACD0.8、 ACD1、 ACD1.2、ACD1.35、ACD4、ACD6
Fire Class Class A、Class B、Class C、Class E、Class F

Standards : EN 50581:2012
EN 62321:2012
Date of Receipt : May 21, 2018
Date of Test : May 21, 2018 - May 25, 2018
Date of Issue : May 25, 2018

Reviewed by:
Jerry Chou
(Chief Engineer)

Prepared By:
NPS China Test Laboratory
NPS building, No.160,GuanChang Road,ChangAn Town,DongGuan City,GuangDong Province,China 523855
HK Phone:+852-53700017 China Phone:+86-769-81883000 www.rohs.gs www.nps.org.cn
UK Phone:+44-20-37342132 USA Phone:+1-213-2895039 www.nps.hk e nps@nps.hk
The sample detailed above has been tested to the requirements of Council Directives 2011/65/EU (EU)2015/863
The test results have been reviewed against the Directives above and found to meet their essential requirements.
Report No: NPS018050349-CE

1 CONTENTS
Page
1 CONTENTS................................................................................................................................................................2
2 TEST SUMMARY......................................................................................................................................................3
2.1 CONCLUSION..................................................................................................................................................... 3
CLIENT............................................................................................................................................................................. 4
INFORMATION...................................................................................................................................................................4
3 ROHS REQUIREMENT........................................................................................................................................... 5
3.1 ROHS LIMITS.................................................................................................................................................... 5
3.2 XRF SCREENING LIMIT IN PPM FOR REGULATED ELEMENTS IN VARIOUS MATRICES....................................5
3.3 OTHER NOTES................................................................................................................................................... 6
3.4 POSSIBLE TEST CASE VERDICTS...................................................................................................................... 6
4 PRODUCT ASSEMBLY INFORMATION............................................................................................................ 7
4.1 PRODUCT COMPONENT STRUCTURE................................................................................................................7
4.2 EXPLOSIVE VIEW...............................................................................................................................................7
5 TEST DATA............................................................................................................................................................... 8
6 CHEMICAL TESTING PROCESS FLOW.......................................................................................................... 10
6.1 LEAD, CADMIUM, MERCURY, HEXAVALENT CHROMIUM TESTING PROCESS FLOW....................................10
6.2 PBBS/PBDES TESTING PROCESS FLOW..................................................................................................... 11
7 PHOTOS OF THE EUT..........................................................................................................................................12
8 EQUIPMENT USED DURING TSET................................................................................................................... 13
9 CE LABEL.............................................................................................................................................................. 14

CE/RoHS Test Report Page 2 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

2 TEST SUMMARY
Test item Test Requirement Test Method RL Result

Lead (Pb) EN 62321:2012 EN 62321, section 8/ 9 /10 2 ppm Pass

Cadmium (Cd) EN 62321:2012 EN 62321, section 8/ 9 /10 2 ppm Pass

Mercury (Hg) EN 62321:2012 EN 62321, section 7 2 ppm Pass

Chromium (CrⅥ) EN 62321:2012 EN 62321, Annex B 5 ppm Pass

Chromium (CrⅥ) EN 62321:2012 EN 62321, Annex C 10ppm Pass

PBBs/ PBDEs EN 62321:2012 EN 62321, Annex A 10 ppm Pass

With reference to EN 62321:2012


(a) Section 6: Screening by X-ray Fluorescence Spectrometry (XRF)
(b) Chemical test:

(1) 1 ppm = 1 ppm = 0.0001%.


(2) RL = (10ppm) = Report Limit
(3) ND = Not Detected ( < RL).
(4) "-" = Not Regulated.

2.1 Conclusion
Tested samples Standard Result

Screening components Screening by XRF spectroscopy Pass

of submitted samples and chemical confirmation test Pass

CE/RoHS Test Report Page 3 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

Test Report
Client Applicant Xiamen Sunford Industry&Trade Co., Ltd.
Information 6F NO 12,LONGSHENGLI,SIMING DISTRICT, XIAMEN
Address
CITY,CHINA
Trade Name N/A
Product Name Fire Ball , Automatic Fire Extinguisher
Model ACD1.3
ACD0.5、ACD0.8、 ACD1、 ACD1.2、ACD1.35、ACD4、
Product Serial no.
ACD6
Detail Class A(Solid/Wood/combustible)
Class B(Liquid/Gasoline/Soluble solids)
Fire Class Class C(combustible gas)
Class E(Electrical object)
Class F(Cooking oil)
Appearance
N/A
& Odor
Lead (Pb),Cadmium (Cd),Mercury (Hg),Chromium (CrⅥ)
Test Items
PBBs/ PBDEs
Test
Test Method With reference to EN 50581:2012、EN 62321:2012
Content
The submitted samples complied with the requirement
Conclusion
of above EN 62321:2012 Standards.
1) When determining for test conclusion, measurement uncertainty of
tests has been considered.
Remark 2) This report shall not be reproduced except in full without the written
approval of the testing laboratory.

Tested by: Reviewed by:

Jack Chen
Andy Yang
Engineer
Supervisor
May 25, 2018
May 25, 2018

CE/RoHS Test Report Page 4 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

3 RoHS Requirement
3.1 RoHS Limits

Restricted substances Limits


Lead (Pb) 0.1% (1000 ppm)
Cadmium (Cd) 0.01% (100 ppm)
Mercury (Hg) 0.1% (1000 ppm)
Chromium(Ⅵ) (Cr6+) 0.1% (1000 ppm)

Polybrominated biphenyls (PBBs) 0.1% (1000 ppm)


Polybrominated diphenyl ethers (PBDEs) 0.1% (1000 ppm)
Di-(2-ethylhexyl) phthalate (DEHP) 0.1% (1000 ppm)
Benzylbutyl phthalate (BBP) 0.1% (1000 ppm)
Dibutyl phthalate (DBP) 0.1% (1000 ppm)
Di-isononyl phthalate (DINP) 0.1% (1000 ppm)

3.2 XRF Screening Limit in ppm for regulated elements in various matrices.

Element Polymer materials Metallic materials Composite materials


Cd BL ≤(70 -3σ)< X <( 130+3σ)≤OL BL ≤(70 -3σ) < X < (70 +3σ)≤OL LOD < X < (150 +3σ) ≤OL

Pb BL≤ (700 -3σ) < X < (1300 +3σ)≤OL BL≤ (700 -3σ) < X < (1300 +3σ)≤OL BL≤ (500 -3σ) < X < (1500 +3σ)≤OL

Hg BL≤ (700 -3σ) < X < (1300 +3σ)≤OL BL≤ (700 -3σ) < X < (1300 +3σ)≤OL BL≤ (500 -3σ) < X < (1500 +3σ)≤OL

Cr BL ≤ (700-3σ)< X BL ≤ (700-3σ)< X BL ≤ (500-3σ)< X

Br BL ≤( 300-3σ)< X Not Applicable BL ≤(250 -3σ)< X

Remark:
-A “BELOW LIMIT” (BL) or “OVER LIMIT” (OL) determination will be set at 30 % (50 % for composite
materials) less than or greater than the limit, respectively. The margins of safety have been agreed
upon based on the experience of many experts and practitioners in the industry. Further explanation
for this approach to estimating uncertainty.
-The symbol “X” marks the region, where further investigation is necessary.
-LOD means Limit of Detection.
-The term “3σ” expresses the repeatability of the analyzer at the action level.

CE/RoHS Test Report Page 5 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

3.3 Other notes


Remark:
-Chemical confirmation tests were conducted to verify the inconclusive results,
Chromium( Ⅵ )(Cr6+), Poly brominated biphenyls(PBBs) and Poly brominated diphenyl
ethers(PBDEs) content.
-As requested by the applicant, only components shown in this report were screened by XRF
spectroscopy for 2011/65/EU other components were not screened included in this report.

Disclaimers:
This XRF Screening Report is for reference purposes only. The applicant shall make its/his/her
own judgment as to whether the information provided in this XRF Screening Report is sufficient
for its/his/her purposes.
The results shown in this XRF Screening Report will differ based on various factors, including
but not limited to, the sample size, thickness, area, surface flatness, equipment parameters and
matrix effect
(e.g. Plastic, Rubber, Metal, Glass, Ceramic etc.). Further wet chemical pre-treatment with
relevant chemical equipment analysis are required to obtain quantitative data.

- Photos are included.

3.4 Possible test case verdicts


-Specimens, which requested to determine Cadmium, Mercury and Lead Content by
chemical test, have been dissolved completely.
- 1ppm = 1ppm(parts per million)
- N.D.=not detected(<RL)
- RL= Report Limit
- N.A.= Not Applicable
- BL= BELOW LIMIT
- OL= OVER LIMIT

CE/RoHS Test Report Page 6 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

4 Product Assembly Information


4.1 Product component structure

4.2 Explosive View

CE/RoHS Test Report Page 7 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

5 Test Data
Chemical confirmation
Serial No. Sample name XRF Results result (ppm) Test Position

Pb N.D.
Cd N.D.
1 Plastic Hg N.D. --
Cr N.D.
Br N.D.
Pb BL
Cd N.D.
2 String Hg BL --
Cr N.D.
Br N.D.
Pb N.D.
Cd N.D.
3 Paper Hg N.D. --
Cr N.D.
Br N.D.
Pb BL
Cd N.D.
4 Glue Hg N.D. --
Cr N.D.
Br BL
Pb BL
Cd BL

5 Cystosepiment Hg N.D. --
Cr N.D.
Br BL
Pb N.D.
Cd N.D.

6 Plastic Hg N.D. --
Cr N.D.
Br N.D.

CE/RoHS Test Report Page 8 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

Chemical confirmation
Serial No. Sample name XRF Results result (ppm) Test Position

Pb N.D.
Cd N.D.
7 Powder Hg N.D. --
Cr N.D.
Br N.D.
Pb N.D.
Cd N.D.
8 Metal Hg N.D. --
Cr N.D.
Br N.D.
Pb N.D.
Cd N.D.
9 Plastic Hg N.D. --
Cr N.D.
Br N.D.
Pb N.D.
Cd N.D.

10 Paper Hg N.D. --
Cr N.D.
Br N.D.

Below is blank

CE/RoHS Test Report Page 9 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

6 Chemical Testing Process Flow


6.1 Lead, Cadmium, Mercury, Hexavalent Chromium Testing Process Flow

Lead, Cadmium, Mercury

Cut and Weigh Add Digested Cool the Digested


the Samples Reagents or Solutions Solution

Analyzed by ICP-AES/ Filter the Digested


AAS Solution

Hexavalent Chromium

Heat Water to boil


Gut sample (50+5) Add 50mL DI water to
and keeping
cm2 beaker
10mins

Add 1mL color


Add 1mL Complement the
developing read
orthophosphoric acid water to 50mL
gent

Analyzed by UV-Vis

CE/RoHS Test Report Page 10 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

6.2 PBBs/PBDEs Testing Process Flow

PBBs/PBDEs Cutting/Preparation

Weigh Sample

PBBs/PBDEs

Sample solvent extraction

Concentration/Dilution of
Extracted Solution

Filtration

GC-MS

DATA

CE/RoHS Test Report Page 11 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

7 PHOTOS OF THE EUT

EUT – Photos 1

产品图 1

EUT– Photos 2

CE/RoHS Test Report Page 12 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

8 EQUIPMENT USED DURING TSET

No. Equipment Manufacturer Model Serial No.

1 ICP-OES Agilent 725 NC01109

2 CV-AAS Agilent / NC011013

3 ICP-MS Agilent 7700e NC012016

4 GC-MS Agilent 7890A NC011002

X-ray Fluorescence
5 Skyray Instrument EDX1800B NC016011
Spectrometry (XRF)
/ / / / /

CE/RoHS Test Report Page 13 of 14


NPS China Test Laboratory
Report No: NPS018050349-CE

9 CE Label
1. The CE conformity marking must consist of the initials‘CE’taking the following form:
If the CE marking is reduced or enlarged, the proportions given in the above
graduated drawing must be respected.
2. The CE marking must have a height of at least 5 mm except where this is not
possible on account of the nature of the apparatus.
3. The CE marking must be affixed to the product or to its data plate. Additionally it
must be affixed to the packaging, if any, and to the accompanying documents.
4. The CE marking must be affixed visibly, legibly and indelibly.It must have the same
height as the initials ‘CE’ Proposed Label Location on EUT
EUT Bottom View/proposed CE Mark Location

※※※ End of Report ※※※