You are on page 1of 2

MICROLAB

AN IS/ISO/IEC 17025 METALLURGICAL SERVICES


Accredited by NABL, Dept. of Science & Technology, Govt. of India.
nd
10A,Sai Nagar, 2 Cross, Opp. Krishnar temple, Sidco Industrial Estate, Coimbatore – 641 021
Phone: 0422 - 2674872. Email: Coimbatore@microlabchennai.com, web: www.microlabchennai.com TC-5848
Page 1 of 1

TEST REPORT

Customer: ULR-TC584820000005681F
M/s. Microtech Precision Engineering Report No / Date ML/G4000/3/20-21/ Dt: 18.12.2020
SF.No:576/5, Pothiyam Palayam Road , Your ref./ Date DC No: 2939/Dt: 10.12.2020
Arasur Village, Sulur Thaluk, Our ref./ Date TOCR: G4000/20-21/ Dt: 10.12.2020
Coimbatore -641 407 Nature of test Inter-granular Corrosion Test
Test Reference ASTM G28 Method A
Date of Testing 17.12.2020-18.12.2020
Sample Draw By Customer
Test Sample
Size: Dia 30mm
Sample
Material Grade: Hast alloy C276
Description
Heat No: VK0049E1G30
Qty: 1No.
1.Inter-granular Corrosion Test (As per ASTM G28):

Observation
Test parameters

Test solution Ferric Sulfate – Sulfuric Acid


Size and Total surface area of the H: 18.11mm; D: 20.02mm;
2
specimen Total surface Area = 17.6770 cm .
Initial weight of specimen 50.3093 gm

Start of test 17.12.2020(1:00pm)

End of test 18.12.2020(1:00pm)

Duration of test 24 hrs


0
Test Temperature 120 C

Final weight of specimen 50.2166 gm

Weight loss 0.0927 gm

Corrosion rate 0.180 (mm/month)

Acceptance criteria 0.08 (mm/month)

Result Test Unsatisfactory

Verified by:
For MICROLAB

S.Venkateshwaran
Authorized Signatory.
------------------------------------------------------------END OF THE REPORT--------------------------------------------------------------

Note: This report relates only to the particular sample submitted for test ❋ any correction in the report will invalidate this report ❋ Sample will be destroyed after 15
days from the date of completion of tests unless informed by the customer❋ Any complaints about this report should be communicated in writing within 7 days of the issue of
this report❋ This report cannot reproduced except in full ❋Sample descriptions is given as described by the customers❋Sampling is not carried laboratory.
Format No: ML/5.10/AD/TR/01.
MICROLAB
AN IS/ISO/IEC 17025 METALLURGICAL SERVICES
Accredited by NABL, Dept. of Science & Technology, Govt. of India.
nd
10A,Sai Nagar, 2 Cross, Opp. Krishnar temple, Sidco Industrial Estate, Coimbatore – 641 021
Phone: 0422 - 2674872. Email: Coimbatore@microlabchennai.com, web: www.microlabchennai.com TC-5848
Page 1 of 1

TEST REPORT

Customer: ULR-TC584820000005681F
M/s. Microtech Precision Engineering Report No / Date ML/G4000/4/20-21/ Dt: 18.12.2020
SF.No:576/5, Pothiyam Palayam Road , Your ref./ Date DC No: 2939/Dt: 10.12.2020
Arasur Village, Sulur Thaluk, Our ref./ Date TOCR: G4000/20-21/ Dt: 10.12.2020
Coimbatore -641 407 Nature of test Chemical analysis (OES)
Test Reference ASTM E415-2017
Date of Testing 17.12.2020
Sample Draw By Customer
Test Sample
Sample
Material Grade: 8.8
Description
Qty: 1No.

1. Chemical Analysis:

Elements Symbol Unit Observed Values

Carbon C % 0.352
Silicon Si % 0.208

Manganese Mn % 0.412
Phosphorus P % 0.033

Sulphur S % 0.026
Chromium Cr % 0.190

Copper Cu % 0.328

Verified by:
For MICROLAB

S.Venkateshwaran
Authorized Signatory.
------------------------------------------------------------END OF THE REPORT--------------------------------------------------------------

Note: This report relates only to the particular sample submitted for test ❋ any correction in the report will invalidate this report ❋ Sample will be destroyed after 15
days from the date of completion of tests unless informed by the customer❋ Any complaints about this report should be communicated in writing within 7 days of the issue of
this report❋ This report cannot reproduced except in full ❋Sample descriptions is given as described by the customers❋Sampling is not carried laboratory.
Format No: ML/5.10/AD/TR/01.