Professional Documents
Culture Documents
TEST REPORT
Page 1 of 5
Report Issued To Imperial Auto Industries Ltd Report No. K9502-0
Plot No.- 48, DLF Ind. Area Phase ULR- TC733223000014746F
- I, Faridabad Date Received 02-06-2023
Date Issued 12-06-2023
Client Information
Recipient Mr Gaurav Singh
Recipient Email gauravsingh@impauto.com,
madhavsingh@impauto.com,
anilazad@impauto.com
Sample Information
Sample Description: PART NO.- 832102496, PART NAME- SHEET, MATERIAL- HR 1 PER IS (1079)
Conformity Specification IS 1079:2017, Grade HR1 <3.0 mm Thick
Results The material conforms to IS 1079:2017, Grade HR1 <3.0 mm Thick with respect to
test/s carried out.
Authorised Sign
(Dr. Amit Bishnoi)
(Technical Head)
WIDMANS LABORATORY (P) LTD.
PLOT NO. 155 E, SECTOR – 7, IMT MANESAR GURGAON, HARYANA (INDIA) 122050
Tel:(0124)4014550,+91-9810930809,+91-9999370036 Mail: mail@widmanslab.comWeb: www.widmanslab.com
TEST REPORT
Page 2 of 5
Report Issued To Imperial Auto Industries Ltd Report No. K9502-0
Plot No.- 48, DLF Ind. Area Phase ULR- TC733223000014746F
- I, Faridabad Date Received 02-06-2023
Date Issued 12-06-2023
Authorised Sign
(Dr. Amit Bishnoi)
(Technical Head)
WIDMANS LABORATORY (P) LTD.
PLOT NO. 155 E, SECTOR – 7, IMT MANESAR GURGAON, HARYANA (INDIA) 122050
Tel:(0124)4014550,+91-9810930809,+91-9999370036 Mail: mail@widmanslab.comWeb: www.widmanslab.com
TEST REPORT
Page 3 of 5
Report Issued To Imperial Auto Industries Ltd Report No. K9502-0
Plot No.- 48, DLF Ind. Area Phase ULR- TC733223000014746F
- I, Faridabad Date Received 02-06-2023
Date Issued 12-06-2023
Bend Test: Test Method : IS 1599:2019
Date of Testing :12-06-2023
Parameter Result
Specimen Size (mm), W x T x L 40.20x3.2x300
Mandrel Size 2t
Angle of Bend, Degree 180
Observation No Crack Observed.
Testing Engineer: Ankit Prakash
Authorised Sign
(Dr. Amit Bishnoi)
(Technical Head)
WIDMANS LABORATORY (P) LTD.
PLOT NO. 155 E, SECTOR – 7, IMT MANESAR GURGAON, HARYANA (INDIA) 122050
Tel:(0124)4014550,+91-9810930809,+91-9999370036 Mail: mail@widmanslab.comWeb: www.widmanslab.com
TEST REPORT
Page 4 of 5
Report Issued To Imperial Auto Industries Ltd Report No. K9502-0
Plot No.- 48, DLF Ind. Area Phase ULR- TC733223000014746F
- I, Faridabad Date Received 02-06-2023
Date Issued 12-06-2023
Hardness (HRBW) Test Method : IS 1586 (Part-1):2018
Date of Testing :09-06-2023
Location-At Surface Temperature (°C) 24.3
S.No Results Unit
1. 58.0 HRBW
2. 59.0 HRBW
3. 59.0 HRBW
Average 58.67 HRBW
Authorised Sign
(Dr. Amit Bishnoi)
(Technical Head)
WIDMANS LABORATORY (P) LTD.
PLOT NO. 155 E, SECTOR – 7, IMT MANESAR GURGAON, HARYANA (INDIA) 122050
Tel:(0124)4014550,+91-9810930809,+91-9999370036 Mail: mail@widmanslab.comWeb: www.widmanslab.com
TEST REPORT
Page 5 of 5
Report Issued To Imperial Auto Industries Ltd Report No. K9502-0
Plot No.- 48, DLF Ind. Area Phase ULR- TC733223000014746F
- I, Faridabad Date Received 02-06-2023
Date Issued 12-06-2023
Microstructure Test: Test Method : ASM Handbook vol 9:2004
Date of Testing :08-06-2023
Location - At Core
Observation General micro structure reveals spherodised structure at 400x magnification
--------------End of Report------------------
Authorised Sign
(Dr. Amit Bishnoi)
(Technical Head)
WIDMANS LABORATORY (P) LTD.
PLOT NO. 155 E, SECTOR – 7, IMT MANESAR GURGAON, HARYANA (INDIA) 122050
Tel:(0124)4014550,+91-9810930809,+91-9999370036 Mail: mail@widmanslab.comWeb: www.widmanslab.com