Test Report

Report No. : JOB/CAA/JAM/23/000862-1 Sample Id No. : 0595


Received Date : 16.03.2023 Reported Date : 16.03.2023

Name Of Customer : Kavita Enterprise


Address Of Customer : Shed No 487, GIDC-2, Vishal Chowk, Dared, Jamnagar, Gujarat, 361004
Samples Received From : Kavita Enterprise
Date Of Analysis 16.03.2023
Sample Descriptions (As Declared)
Product Name : BRASS INSERT
Sample Status : Satisfactory,
Other Details : N/A
The Above Sample(S) Was/Were Examined as Detailed Above and The Following Results Obtained.
Test Test Method Specification Result
With Reference to IEC 62321-5:2013
Cadmium As Cd, Mg/Kg 100 Max. 32
(Determination By ICP-OES)
With Reference to IEC 62321-5:2013
Lead As Pb, Mg/Kg 40000 Max. 38425
(Determination By ICP-OES)
With Reference to IEC 62321-5:2013
Mercury as Hg, Mg/Kg 1000 Max. <1.0
(Determination By ICP-OES)
With Reference to IEC 62321-5:2017
Chromium Hexavalent as Cr (Vi), Mg/Kg 1000 Max. <1.0
(Determination By ICP-OES)
• Test Results Summary of Heavy Metals for ROHS Directive 2011/65/Eu,
• The Above Limits Were Quoted From 2002/95/Ec and Amendment 2005/618/Ec for Homogeneous Materials

______________________________
Jayanti Koringa
(Authorized Signatory)

Note : The results reported relate to the sample tested only. The Test Certificate shall not be reproduced in full or part without the written permission of INTERTEK. The sample(s) has been not
drawn/sampled by INTERTEK LAB. The reported result(s) provide no warranty or verification on the sample(s) representing any specific goods and / or shipment and only relate to the sample(s) as
received and tested. This report was prepared solely for the use of the client named in this report. Intertek disclaims any and all liability for damage or injury which results in the use of the information
contained herein and accepts no responsibility for any loss, damage or liability suffered by a third party as a result of any reliance upon or use of this report. All jobs are performed as per Intertek terms &
Conditions available at htpp://www.intertek.com/terms/or can be made available on request

Issue No.: 02 Amend No.: 00


IIPL/17025/QF/7.8/01
Issue Date.: 01.06.2022 Amend Date.: 00.00.0000
Page No. 1 of 2
Intertek India Private Limited Ph.: +91 288 2730438/463,
201-204, 2nd Floor, Plot No. 4056, Fax.: +91 288 2731037,
GIDC- Phase - III, Dared, Email: lab.jamnagar@intertek.com
Jamnagar – India – 361 004. www.intertek.com

Test Report

Report No. : JOB/CAA/JAM/23/000862-1 Sample Id No. : 0595


Received Date : 16.03.2023 Reported Date : 16.03.2023

Sample Picture Is Here

-: End Of Report: -

______________________________
Jayanti Koringa
(Authorized Signatory)

Note : The results reported relate to the sample tested only. The Test Certificate shall not be reproduced in full or part without the written permission of INTERTEK. The sample(s) has been not
drawn/sampled by INTERTEK LAB. The reported result(s) provide no warranty or verification on the sample(s) representing any specific goods and / or shipment and only relate to the sample(s) as
received and tested. This report was prepared solely for the use of the client named in this report. Intertek disclaims any and all liability for damage or injury which results in the use of the information
contained herein and accepts no responsibility for any loss, damage or liability suffered by a third party as a result of any reliance upon or use of this report. All jobs are performed as per Intertek terms &
Conditions available at htpp://www.intertek.com/terms/or can be made available on request

Issue No.: 02 Amend No.: 00


IIPL/17025/QF/7.8/01
Issue Date.: 01.06.2022 Amend Date.: 00.00.0000
Page No. 2 of 2