Professional Documents
Culture Documents
WIOMANS LAB
TUV ilac-MRA
SUD
NASC
TC-7332
TEST REPORT
Page 1 of 2
Report Issued To Hitech Engineers Report No0. D4474
Plot No. 245, 246, Sector-7, IMT ULR- TC733221000010176F
Manesar, Gurgaon Date Received 09-03-2022
Date Issued 14-03-2022
Client Informatio 1
Recipient Mr Akash Kumar
Recipient Email npd@thehitech.com.quality@thehitech.co
m
Sample Information
Sample Description: ELVIED COATING)
Quantity Submitted: 1
Testing Period: 09-03-2022-14-03-2022
Conformity Specification
ars)
Authorised Sign
WIDMANS LABORATORY (P) LTD.
PLOT NO. 155 E, SECTOR -7, IMT MANESAR GURGAON, HARYANA (INDIA) 122050
Tel:/0124)4014550,+91-9810930809,+91.9999370036 Mail: mail@widmanslab.comWeb: www.widmanslab.com
TC-7332
TEST REPORT
Page 2 of 2
Report Issued To Hitech Engineers Report No. D4474
Plot No. 245, 246, Sector-7, IMT ULR- TC733221000010176F
Manesar, Gurgaon Date Received 09-03-2022
Date Issued 14-03-2022
ELV/ROHSTest: Test Method:WI/WL/01:2016
Parameter Result Permissible Limit Protocol
Lead (as Pb) <10 1000 ppm Max AAS/ WL/WI/01
Cadmium (as Cd) <20 100 ppm Max AAS/ WL/WI/01
Murcury (as Hg) Not Detected 1000 ppm Max AAS/ WL/Wi/01
Hexavalent Chromium (as Cr+6) 10 1000 ppm Max AAS/ WL/WI/01
Testing Engineer:Amjad Khan
--End of Report---.
fars
Authorised Sign
WIDMANS LABORATORY (P) LTD.
PLOT NO. 155 E, SECTOR-7, IMT MANESAR GURGAON, HARYANA (INDIA) 122050
Tel:(0124)4014550,+91-9810930809,+91-9999370036 Mail: mail@widmanslab.comWeb: www.widmanslab.com