1.0 SCOPE:
This procedure applicable for Magnetic Particle Examination of establishes a method of locating
surface and near surface discontinuities in Peeled bars (Before Forging) stage of A668 Raw
material 75 RCS
6.0 EQUIPMENT:
A. Magnaflux make or suitable model with bench type unit.
B Fluorescent black light with black light intensity-min 1000 micro w/cm2..
B. Fluorescent Magnetic Powder.
C. Pie - Shaped ASTM Field indicator or KETOS Ring.
D. Centrifugal Tube with Stand.
E. Residual field Indicator.
b) Procedure: The Accuracy of the ammeters shall be verified by equipment traceable to national
standard. Comparative reading shall be taken for at least three different current
output levels encompassing the usable range.
c) Tolerance: Ammeter reading shall not deviate by more than 10% of full scale, relative to the
actual current value as showed by test meter.
SANASWADI Revision 00
Date 14.12.2019
Magnetic Particle Examination Page 2 of 5
WIFPL/YKE/MPI/
Procedure for A668 bars for Yoke A668-Yoke/01
Forgings Die No.: 1085
d) Black light intensity shall be checked for every six months to ensure minimum black light
intensity 1000µw/cm2.
9.0 MAGNETIZATION :
a) Circular Magnetization :
Magnetization is accomplished by passing AC/HWDC, by head shot method keeping the bars
suitably on V-supports of the machine. Place the pie shaped ASTM-Field indicator on the job over
the area under examination and adjust the Magnetization step gradually until correct flux density is
evident on ASTM-field indicator by spraying testing medium simultaneously .if clear indications
observed on ASTM-field indicator, record and set the current for testing.
Apply current shot and examine under the black light while simultaneously spraying a small
quantity of the prepared medium over the area under examination by a sprayer. Mark indications if
any and evaluate them.
The temperature of the part shall not exceed 570C for wet magnetic particle method(As per ASME,
Section –V and SE-709 Clause8.4).
75 mm RCS bars shall be magnetized by passing 1200 to 2400 amperes (Current will be set on pie
gauge)
b) Longitudinal magnetization:
Magnetization is accomplished by a coil, fed by DC/HWDC. Place the Pie shaped ASTM-field
indicator on the job over the area under examination and adjust the Magnetization step gradually
until correct flux density is evident on ASTM-field indicator by spraying testing medium
simultaneously. If clear indications observed on ASTM-field indicator, record and set the current
for testing.
Apply current shot and examine under the black light while spraying a small quantity of the
prepared medium simultaneously over the area under examination by a sprayer. Mark indications if
any and evaluate them.
Suggest current for 75 mm RCS bars is 4.5 KAT.
13.0 DEMAGNETIZATION:
After magnetic particle inspection, all bars shall be demagnetized. Demagnetization is achieved by
withdrawing the job through a coil carrying current at mains frequency. In this process the job is
subjected to a diminishing magnetic field of reversing polarity & stands demagnetized to level of 2
gauss Flux. Strength of residual filed is checked by residual file indicator.
14.0 DOCUMENTS:
A test report duly signed by WIFPL,YKEPL containing all relevant information shall be submitted to
NPCIL-QS on completion of examination for review.