Technical catalogue Alpha and FX family
Product catalogues for programmable logic controllers and
accessories for the Alpha and FX families
This technical catalogue is designed to give an overview of the extensive range of moulded-case circuit breakers of the World Super
Series and related accessories. If you cannot find the information you require in this catalogue, there are a number of ways you can get
further details on configuration and technical issues, pricing and availability.
For technical issues visit the www.mitsubishi-automation.com website.
Our website provides a simple and fast way of accessing further technical data and up to the minute details on our products and
services. Manuals and catalogues are available in several different languages and can be downloaded for free.
For technical, configuration, pricing and availability issues contact our distributors and partners.
Mitsubishi partners and distributors are only too happy to help answer your technical questions or help with configuration building.
For a list of Mitsubishi partners please see the back of this catalogue or alternatively take a look at the “contact us” section of our
website.
This catalogue is a guide to the range of products available. For detailed configuration rules, system building, installation and configura-
tion the associated product manuals must be read. You must satisfy yourself that any system you design with the products in this cata-
logue is fit for purpose, meets your requires and conforms to the product configuration rules as defined in the product manuals.
Specifications are subject to change without notice. All trademarks acknowledged.
© Mitsubishi Electric Europe B.V., Factory Automation - European Business Group, 02/2008, 5th edition
2 MITSUBISHI ELECTRIC
/// CONTENTS
웇 Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
웇 Electronic Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
웇 Calculation and Selection Software MELSHORT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
웇 Product Skeleton of Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
웇 Model Overview and Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Das Inhalts-
verzeichnis wird nach der Freigabe aktualisiert!
MITSUBISHI ELECTRIC 3
World Super Series WSS – The Extensive Breaker Series from MITSUBISHI ELECTRIC
The circuits of the Mitsubishi breaker series are amongst the The system is based, among other things, on the well-known and
smallest compact circuit breakers in the world with electronic proven microprocessor technology.
overload indication of this kind.
JIS
MITSUBISHI Ue
Icn
35kA
OFF
550VAC
50kA
NO-FUSE BREAKER 460VAC
85kA
EN60947-2 220VAC
IEC60947-2
MITSUBISHI OFF JIS C 8201-2
40°C
Icu/Ics
MODEL
NF400-SEP IEC 60947-2
MITSUBISHI
10/10kA
MODEL 22/22kA 30/30kA EN60947-2
NF125-SGW 525VAC Icu/Ics
30/30kA 42/42kA Ue
500VAC
36/36kA 3P
45/45kA NO-FUSE BREAKER 690VAC
25/13kA
440VAC POLE 85/85kA 65/33kA
36/36kA 400 40°C MODEL
NF1000-SS
500VAC
In 125A 380/415VAC
230VAC
85/85kA
20/20kA
Ui 690VAC
50 - 60Hz
500VAC
50kA
440VAC
400VAC
85/43kA
85/43kA
125/63kA
300VAC 8kV 85kA 230VAC
Ir 80-125A Uimp 250VAC
In 1000A Cat. B Icw 20kA 0.1s
POLE
Ui690V
3P
Uimp 8kV
ON Ir 500-1000A
Cat.A ON
PUSH TO TRIP
MITSUBISHI ELECTRIC
MITSUBISHI ELECTRIC
PUSH TO TRIP
MITSUBISHI ELECTRIC
T Ir
MODEL Ip 300 8 10
70% PAL OVER 4 5 6
RE100 In 100A Is
Ii 250
350 3.5 7 6 12
50/60Hz TL 220 3 14
Ts 2.5 8
Ip(xIr) 400 2 10 4 16
IS(xIr) TS(S) Ii(X100A) 200
Ir(A) TL(S) 8 10 Ii(X400A)
4 5 6 .2 Ir(A) IS(xIr)
80 .1 6 12 TEST .1 .2
60 80 3.5 7 60 80
3
8 .10
2.5 .3 4 14 .07 T Ir .10 PUSH TO TRIP
100 2 10 .06 100 .06 .3 .07
63 100 12 Ip 12
Is Ip(xIr)
Ii TL(sec) TS(sec)
TL
Ts
OVER
PAL
70%
4 5 6 8 10
300 .7 .8 12
250 3 7 6
350 14
T Ir 225 8
16
Ip
Is 1 2 10 4
.5
Ii 200 IS (×In, Ir ) II(×400A)
TL Ir(×400A)
Ts In(A) .2 .8 .9
60 100 .1
TEST 150
.3 .7 1.0
12 .06
T S (s) IP (×In, Ir)
T L (s)
The new WSS breaker series meets The proven World Super Series features The proven standard series for a high
national and international protection rat- technical know-how and the micro- breaking performance providing an opti-
ings according to VDE, EN, and IEC stan- processor technology tried and tested in mum protection for transformer and gen-
dards for industrial applications as well as longstanding experience. erator feed in, and output breakers.
for extended shipping demands. The fully enclosed circuit breakers provide Circuit breakers can be used as section or
The new tripping technology guarantees a an increased safety and at the same time disconnecting switch.
high reliability and highest protection. decreased switching times.
앬 1000 to 1600 A
앬 16 to 250 A in one model size (3- and 앬 400 to 800 A 앬 1 model size (3- and 4-pole)
4-pole) 앬 2 model sizes (3- and 4-pole) 앬 electronic trip system
앬 interchangeable relay unit (thermal 앬 electronic trip system 앬 available in fixed versions
type or electronic type) 앬 available in fixed and plug-in versions 앬 additional disconnectors available
앬 available in fixed and plug-in versions 앬 additional disconnectors available
앬 breaking capacity
Ics = 100 % Icu, up to 690 V
앬 additional disconnectors available
10 SGW
7,5 HW
5 SW SW
4 MITSUBISHI ELECTRIC
Outline
With its new breaking technology the technology and innovative engineering,
circuit breakers offer greater safety and with a newly developed electronic trip
even faster circuit-breaking speed relay.
through the use of the latest switch-off
ent
of grid gap, shape, and material. handle, minimizing contact wear and
em
mov d ensuring safety.
i
R ap
Magnetic flux
Grid
Magnetic Arc
force
앬 Trip indication
Arc extinction
The automatically tripped condition is
indicated by the handle in the center
position between ON and OFF; the yel-
low or white line cannot be seen in this
position.
The arc is instantaneously trans- The figure shows the handle in tripped
ferred to the arc-extinguishing position.
chamber (see the figure above) 앬 Resetting
by the arc runner, which reduces Resetting after tripping is performed by
damage to contacts and first moving the handle OFF position to
improves interrupting perfor- engage the mechanism, then returning
mance. MITSUBISH I
OFF
IEC60947-2
JIS C 8201-2
EN60947-2
40°C
Icu/Ics the handle to ON to reclose the circuit.
KER
NO-FUSE BREA Ue
8/8kA
690VAC
22/22kA
NF125-SGW
앬 Trip-Free
MODEL 525VAC
30/30kA
500VAC
36/36kA
440VAC
36/36kA
380/415VAC
In 100A 230VAC
85/85kA
20/20kA Even if the handle is held at ON, the
300VAC
Ir 63-100A
POLE
Ui690V
3P
Uimp 8kV
breaker will trip if an overcurrent flows.
ON
Cat.A
MITSUBISHI ELECTR
IC 앬 Contact on Mechanism
PUSH TO TRIP
TS(S)
TL
Ii(X100A)
8
Ts
10
Ip(xIr) breaker will trip and the handle will
4 5 6
ing state.
63
MODEL T Ir
RE100 In 100A Ip
Is 70% PAL OVER
50/60Hz TL Ii
Ts
IS(xIr)
Ir(A)
80
60
TL(S)
80 3.5
4 5 6
7
.1
TS(S)
.2
Ii(X100A)
6
8 10
12
Ip(xIr)
The setting can be changed by simply
3
63 100 12 100
2.5
2
8
10 .06 .3 4 14 .07 .10 turning the control dials, providing the
optimum characteristics for particular
Trip relay with control dials road conditions.
MITSUBISHI ELECTRIC 5
Electronic device loads, such as inverters, Our electronic moulded-case circuit The pre-alarm module (with contact
distort the current waveform. Mitsubishi’s breakers feature a pre-alarm system as output) is optional available with
electronic breakers use a digital detector standard. The pre-alarm outputs an alarm electronic molded-case and earth-leakage
to measure the current’s effective value before the circuit breaker trip is activated. circuit breakers (on request).
and minimize overload tripping errors. When the load current exceeds the set
This enables precise protection of the pre-alarm current, it outputs a pre-alarm
circuit. signal (from a solid-state relay) and lights
the LED.
Current setting Ir
High-voltage fuse allowable
short-time characteristic
Our standard electronic trip relay offers a High
voltage
number of outstanding benefits.
The user has a choice of six different Long time-delay
operating time TL Low
parameters as tripping characteristics with voltage
the multiple coordinated protection Pre-alarm
Time [s]
Instantaneous tripping
current II
Current [A]
250 300 .7 .8 4 5 6 8 10
3 7 6 12 Instantaneous tripping current II
225 350
8 14
200 .5 1 2 10 4 16
In(A) Ir(×400A) IS (×In, Ir ) II(×400A)
60 100 .1 .2 .8 .9 Pre-alarm current IP
TEST 150
12 1.0
.06 .3 .7
T L (s) T S (s) IP (×In, Ir)
NF400-SEW 3P
L1
The neutral-pole overload protection cir-
The separately sold portable tester allows cuit is standard with 4-wire electronic
the user to check the four characteristics: moulded-case devices. L2
앬 1. Long-delay tripping It prevents burn-out when the neutral-
앬 2. Short-delay tripping pole’s load current is greater than the
앬 3. Instantaneous tripping voltage pole in a 3-phase 4 wire circuit
which is prone to distorted third-harmonic L3
앬 4. Pre-alarm characteristics
current flows.
LEDs for load current, pre-alarm and
over-current show the operating status.
N
6 MITSUBISHI ELECTRIC
MITSUBISHI ELECTRIC 7
10
see page 12
see page 35
see page 35
see page 41 11
see page 40
see page 40
see page 40
12 16
98
ALc
see page 35
96
ALa ALb
98
ALARM SWITCH
5A
3A
0.4A
0.2A
125V
250V
125V
250V
AC
AC
DC
95
c
DC
96
b
AX AL
98
a
14
a
ALAX-2GSWLS
14
MITSUBISHI ELECTRIC
AXc AXb AXa
see page 35
12
b
12
11
c
11
AUXILIARY SWITCH
5A
3A
0.4A
0.2A
125V
250V
125V
250V
AC
AC
DC
DC
see page 41
see page 37
13 1
see page 37
see page 36
see page 36
see page 39 ED
ON
P
IP
TR
OFF T
SE
see page 26
T Ir
RE MODEL Ip
70% PAL OVER
PUSH RE100 In 100A Is
Ii
TO 50/60Hz TL
TRIP Ts
Ip(xIr)
IS(xIr) TS(S) Ii(X100A)
Ir(A) TL(S) 8 10
4 5 6 .1 .2 6 12
80 3.5
60 80 7
3
8 .10
2.5 .3 4 14 .07
100 2 10 .06
63 100 12
see page 30
see page 28
14 17
ON
SOURCE
ED
D3 D2
P3 P2
Hi Lo
D1
P1
P
IP
TR
OFF
RE
UVTSA250-2GSWRS
PUS
TO H
TRIP
15 18
OFF
S4
ON
S2
K1 K1
K1 S1
K2
K2
P2 Uc
K3
P1 Supply
SW1 Power
Uc K2
K3 Operating
K3
Circuit
S2 S4
S1
P1 P2
SHT
C1
S1
AC100-240V
50/60Hz
C2
S2
P2 S1 S2 S4
P1
MODEL MSDBA-NF25GSW
MITSUBISHI A0106 햳
POWER SUPPLY MODULE SERIAL:
NO-FUSE BREAKER ON
MODEL NF250-SGW
50/60Hz
Uimp 8kV
Ui 690V
Push to Cat.A
EN60947-2
IEC60947-2
40°C
JIS C 8201-2 (MANU)
ON Ue
Icu/Ics
8/8kA
690VAC Dis-
22/22kA
525VAC charge
30/30kA
500VAC 햲
36/36kA
AUTO 440VAC
36/36kA
380/415VAC Push
Push to 230VAC
85/85kA
MITSUBISHI ELECTRIC
OPEN
(TRIP) RATED CURRENT
MANU
250 A
8 MITSUBISHI ELECTRIC
4 5 6 7
2 3
1 9 8
IEC60947-2 EN60947-2
9
20/20kA
300VAC
Ir 75-125A
3P
POLE
Ui690V Uimp 8kV
Cat.A ON
PUSH TO TRIP
MITSUBISHI ELECTRIC
2 3
4 5 6 7
MITSUBISHI ELECTRIC 9
690 V 2.5 / 1 20 / 20 20 / 20 20 / 20 20 / 20
500 V 7.5 / 4 50 / 50 50 / 50 50 / 50 50 / 50
IEC 947-2
[kA] AC 햲 440 V 10 / 5 65 / 65 65 / 65 65 / 65 65 / 65
EN 60 947-2
(50/60 Hz)
VDE 0660
(Icu / Ics)
230 V 25 / 13 100 / 100 100 / 100 100 / 100 100 / 100
Ui [V] 690
690 V 25 / 25
Ui [V] 690
3/4
690 V 30 / 30
Ue [V] AC (50/60 Hz) / DC 500 / 250 500 / 250 690 / 300 690 / 300
[A] (breaking) AC/DC 256 / 128 504 / 252 1000 / 500 1280 / 640
10 MITSUBISHI ELECTRIC
30 / 30 30 / 30 30 / 30 햳 30 / 30 30 / 30 65 / 33 65 / 33 65 / 33
햳
36 / 36 36 / 36 42 / 42 42 / 42 42 / 42 85 / 43 85 / 43 85 / 43
햳
20 / 20 20 / 20 10 / 10 15 / 15 15 / 15
50 / 50 50 / 50 50 / 50 50 / 50 50 / 50
65 / 65 65 / 65 65 / 65 65 / 65 65 / 65
100 / 100 100 / 100 100 / 100 100 / 100 100 / 100
3 3 3 3
25 / 25 15 / 10 20 / 15 20 / 15
125 / 125 70 / 35 70 / 35 70 / 35
30 / 30 35 / 35 35 / 35
690 / 300 690 / 250 690 / 250 690 / 250 660 / 250 660 / 250 660 / 250
2000 / 1000 3200 / 1600 5040 / 2520 6400 / 3200 8000 / 14000 10000 / 5000 12800 / 6400
* adjustable
MITSUBISHI ELECTRIC 11
3, 4, 6, 10, 16, 20, 3, 4, 6, 10, 16, 20, 10, 16, 20, 25, 32, 16–25, 25–40, 40–63, 16–32, 32–63,
In [A]
40 °C 25, 32 25, 32, 40, 50, 63 40, 50, 63 63–100, 80–125 63–100, 75–125
at ambient temperature
Fixed Fixed Fixed Adjustable Adjustable
3 3/4 3/4 3/4 3/4
voltage Ui [V] AC 600 600 690 690 690
690 V — — 2.5 / 1 8/8 8/8
500 V 2.5 / 1 7.5 / 4 7.5 / 4 30 / 30 30 / 30
AC 440 V 2.5 / 1 7.5 / 4 10 / 5 36 / 36 36 / 36
[kA] (50/60 Hz)
IEC/EN 60947-2
ca
a 75 75 / 100 75 / 100 105 / 140 105 / 140
a c
b 130 130 130 165 165
[mm]
b c 68 68 68 86 86
ca 90 90 90 110 110
[kg] 0.55 0.60 / 0.70 0.60 / 0.70 2.0 / 2.6 2.0 / 2.6
Alarm switch (AL) 쏹 쏹 쏹 쏹 쏹
Auxiliary switch (AX) 쏹 쏹 쏹 쏹 쏹
Shunt trip (SHT) 쏹 쏹 쏹 쏹 쏹
12 MITSUBISHI ELECTRIC
쏹 쏹 쏹 쏹 /—
— 쏹 — —
— 쏹 — —
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
— — — —
LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB
Thermal-magnetic Electronic Thermal-magnetic Thermal-magnetic
Equipped Equipped Equipped Equipped
MITSUBISHI ELECTRIC 13
ca
a 105 / 140 105 / 140 105 / 140 105 / 140
a c
b 165 165 165 165
Dimensions [mm]
b c 86 86 86 86
ca 110 110 110 110
Weight [kg] 2.0 / 2.6 2.0 / 2.6 2.0 / 2.6 2.0 / 2.6
Alarm switch (AL) 쏹 쏹 쏹 쏹
Auxiliary switch (AX) 쏹 쏹 쏹 쏹
Cassette-
type Shunt trip (SHT) 쏹 쏹 쏹 쏹
accessories
Undervol- Non-synchronousclosing (UVT-N) — — — —
tage trip Synchronous closing (UVT-S) 쏹 쏹 쏹 쏹
14 MITSUBISHI ELECTRIC
125–160, 160–250 125–250 125–160, 160–250 125–250 125–160, 160–225 125–160, 160–225
Adjustable Adjustable Adjustable Adjustable Adjustable Adjustable
3/4 3/4 3/4 3/4 3 3/4
690 690 690 690 690 690
8/8 8/8 20 / 20 20 / 20 25 / 25 30 / 30
30 / 30 30 / 30 50 / 50 50 / 50 125 / 125 200 / 200
36 / 36 36 / 36 65 / 65 65 / 65 125 / 125 200 / 200
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
— — — — — —
쏹 쏹 쏹 쏹 쏹 쏹
— — — — — —/쏹
쏹 쏹 쏹 쏹 쏹 —
— 쏹 — 쏹 — —
— 쏹 — 쏹 — —
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹/—
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
— — — — — —
LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB
Thermal-magnetic Electronic Thermal-magnetic Electronic Thermal-magnetic Thermal-magnetic
Equipped Equipped Equipped Equipped Equipped Equipped
MITSUBISHI ELECTRIC 15
16 MITSUBISHI ELECTRIC
— 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
LR, GL, BV, AB LR, GL, BV, AB LR, GL, BV, AB LR, GL, BV, AB
Electronic Electronic Electronic Electronic
Equipped Equipped Equipped Equipped
MITSUBISHI ELECTRIC 17
18 MITSUBISHI ELECTRIC
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
쏹 — — —
쏹 쏹 쏹 —
쏹 — — —
쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹
— LR, GL, AB LR, GL, AB —
Electronic Electronic Electronic Electronic
Equipped Equipped Equipped Equipped
MITSUBISHI ELECTRIC 19
Making cur- AC / DC A 320 / 128 630 / 252 1250 / 500 1600 / 640 2500 / 1000
rent cycles 5 5 3/5 3/5 3/5
Making and
braking current
Breaking cur- AC / DC A 256 / 128 504 / 252 1000 / 500 1280 / 640 2000 / 1000
rent cycles 5 5 3/5 3/5 3/5
햲 햳 햴 햵 햶
This performance is accordance with IEC60947-2 clause 7.2.4.1. On request. Standard. Assembly by factory. TC-N.
Missing specifications accord. to IEC/EN 60947-2 on request.
20 MITSUBISHI ELECTRIC
— — — — — —
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
— — — — — —
쏹 쏹 쏹 쏹햶 쏹햶 —
— — — — — —
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
쏹 쏹 쏹 쏹 쏹 쏹
— — — — — —
MITSUBISHI ELECTRIC 21
3A 16–25 A
4A 25–40 A
6A 40–63 A
10 A 63–100 A
16 A 80–125 A
20 A
25 A
32 A 16–32 A
32–63 A
3A 63–100 A
4A 75–125 A
6A
10 A
16 A 16–25 A
20 A 25–40 A
25 A 40–63 A
32 A 63–100 A
40 A 80–125 A
50 A
63 A
16–32A
32–63A
10 A 63–100A
16 A 75–125A
20 A
25 A
32 A 16–25 A
40 A 25–40 A
50 A 40–63 A
63 A 63–100 A
16–25 A
25–40 A
40–63 A
63–100 A
햲
Reference to breaker specifications on p. 12ff.
22 MITSUBISHI ELECTRIC
125–160 A 125–160 A
160–250 A
80–160 A
125–250 A
125–160A
160–225 A
80–160 A
125–160 A
160–225 A
125–160 A
160–250 A
125–250 A
200–400 A 200–400 A
300–630 A 300–630 A
400–800 A 400–800 A
200–400 A 200–400 A
300–630 A 400–800 A
400–800 A
Order Information for Moulded-Case Circuit Breakers Order Information for Disconnectors
1000–1600 A DSN series 32–1600 A
햲 햲
500–1000 A 32 A
600–1250 A 63 A
800–1600 A 125 A
160 A
250 A
400 A
630 A
800 A
1000 A
1250 A
햲 1600 A
Reference to breaker specifications on p. 12ff.
MITSUBISHI ELECTRIC 23
023.prn 23
????
Donnerstag, 28. Februar 2008 09:10:09
Farbprofil: Deaktiviert
Komposit Standardbildschirm
Internal Accessories
The new arrangement and design of The presence of separate circuit chambers The cassette type accessories are available
pluggable accessories such as indicator makes the system even safer. in several versions and fit for breaker series
and auxiliary contacts allows you to Thus cassette type accessories ensure from 32 A up to 800 A:
modify the circuit in a way that saves time flexibility when upgrading circuits. 앬 alarm switch (AL)
and space – at any time, even when built in 앬 auxiliary switch (AX)
and ready for operation. 앬 alarm and auxiliary switch (AL+AX)
앬 shunt trip device (SHT)
앬 undervoltage trip device (UVT)
with lead-wire terminal block as standard.
In addition you can choose the lead-wire
version or the internal terminal type as an
option.
Provides for indication that the MCCB Provides for indication of whether the
has tripped. breaker is ON or OFF.
AC100-240V
98
T Ir
Ip PAL OVER
In 100A Is 70%
RE100
5A
Ii
3A
50/60Hz TL
0.4A
Ts
0.2A
Ir(A) TL(S) 8 10
125V
250V
4 5 6
3
AC
8 .10
14 .07
DC
2.5
95
.3 4
c
SHTA240-2GSWRS
DC
100 2 10 .06
63 100 12
96
b
AX AL
available as internal
98
a
14
a
ALAX-2GSWLS
14
MITSUBISHI ELECTRIC
AXc AXb AXa
12
11
c
Example: SHT
11
AUXILIARY SWITCH
The connection
AC
AC
DC
DC
For the breakers of the Super Series, 1000 A up to 1600 A, please contact your Distributor.
24 MITSUBISHI ELECTRIC
The alarm switch AL indicates that the breaker has tripped. page 26
The shunt trip SHT trips the breaker automatically by remote. A cut-off switch is integrated. page 28
The allowable tripping voltage is 70% to 110% of the rated voltage for both AC and DC.
The undervoltage trip UVT trips the breaker automatically when the voltage drops. The tripping voltage is 35% to 70% of the page 30
rated voltage. When the voltage recovers to 85% of the rated voltage or above, the UVT can be reset and the breaker closed.
For the connection of the control wires 앬 Lead-wire terminal block (SLT)
MITSUBISHI ELECTRIC offers you two ways: 앬 Internal terminal type for direct connection.
The terminal cover for the lead-wire screws is adopted for easier wiring.
96
ALa ALb
95
c
DC
96
b
AX AL
ALAX-2GSWLS
14
MITSUBISHI ELECTRIC
AXc AXb AXa
12
b
12
11
c
11
AUXILIARY SWITCH
5A
3A
0.4A
0.2A
125V
250V
125V
250V
AC
AC
DC
DC
Cassette-type accessory
Example:
ALAX, also for SHT, UVT
Optional the cassette-type accessories 앬 Quick install and de-install of the inter-
are available as internal terminal type nal accessories is possible without
without terminal block. demounting the breaker.
The control wires can be connected to 앬 Mounting of several breakers
AL-2GSWN
MITSUBISHI ELECTRIC
98
ALa
96
ALb
the integrated screw terminals and can side-by-side in a row is possible.
be lead out of the breaker housing in 앬 Thus the screw terminals for control
Example: line-side direction. wires are inside of the breaker hous-
AL, also for SHT, UVT
ing, no special terminal cover for the
screw terminals is necessary.
Screw terminals
MITSUBISHI ELECTRIC 25
SHT
C1
C1
앬 Internal terminal type is also available.
S1
S1
AX
14
a
C2
C2
S2
S2
AC100-240V AC100-240V
14
50/60Hz 50/60Hz
12
b
12
11
c
SHTA240-2GSWRS SHTA240-2GSWRS
0.2A
125V
250V
125V
250V
AC
AC
DC
DC
Ir Ir
MODEL Ip MODEL Ip
70% PAL OVER
RE100 In 10 Is
Ii RE100 In 10 Is
Ii
50/6 TL 50/60 TL
Ts Ts
Ts
Ir(A)
80
60
TL(S)
80 3.5
3
IS(xIr)
4 5 6
7
Ir(A)
80
60
TL(S)
80 3.5
3
IS(xIr)
4 5 6
7
98 14
2.5 8 2.5 8
100 2 10 . 100 2 10 .0
63 100 12 63 100 12
96 12
95 11
(1 W) (1 W)
Figure shows Lead-wire terminal block type (SLT). Figure shows Internal terminal type.
Alarm switch AL Auxiliary switch AX
Switching Operation
26 MITSUBISHI ELECTRIC
1W NF/DSN32–63
1W NF/DSN125–250
1W
NF/DSN400–800 Left side
2W
3W NF/DSN800
1W NF/DSN1000–1600
1W
NF/DSN32–63
2W
1W
NF/DSN125–250
2W
1W
NF/DSN400–800
2W Left side
3W NF/DSN800
4W NF400-UEW 4P
1W
2W NF/DSN1000–1600
3W
1W
NF/DSN125–250 Left side
2W
1W+1W NF/DSN32–63
1W+1W NF/DSN125–250
1W+1W NF/DSN400–800
NF400-UEW 4P Left side
2W+2W
1W+1W
NF/DSN1000–1600
1W+2W
MITSUBISHI ELECTRIC 27
C1
S1
available).
C2
S2
AC100-240V AC100-240V
50/60Hz 50/60Hz
C1
Figure shows Lead-wire terminal block type (SLT). Figure shows Internal terminal type.
SHT
C2
햴
햲 햳
햵
Equipped 50
AC 24–48
AC 100–240
AC 380–550 120 ≤15
(50 / 60 Hz)
Equipped DC 100–125 60
28 MITSUBISHI ELECTRIC
AC 24–48 V
AC 100–240 V
AC 380–550 V
DC 12 V
NF/DSN32–63 NF/DSN32–63
DC 24–36 V
DC 36–48 V
DC100–125 V
DC220–250 V
AC 24–48 V
AC 100–240 V
AC 380–550 V
DC 12 V
NF/DSN125–250 NF/DSN125–250
DC 24–36 V
DC 36–48 V
DC100–125 V
DC220–250 V
AC 100–450 V / DC 100–200 V
NF/DSN400–800 NF/DSN400–630 AC 24–48 V / DC 24–48 V
AC 380–550 V
AC 100–450 V / DC100–200 V
— NF/DSN800 AC 24–48 V / DC 24–48 V
NF400-UEW 4P
AC 380–550 V
AC 100–120 V
AC 200–240 V
NF/DSN1000–1600 NF/DSN1000–1600 AC 380–450 V
DC 24 V
DC 110 V
AC 24–48 V
AC 100–240 V
AC 380–550 V
DC 12 V
NF/DSN125–250
DC 24–36 V
DC 36–48 V
DC 100–125 V
DC 220–250 V
MITSUBISHI ELECTRIC 29
Hi Lo
D1
P1
T Ir T Ir
Ip Ip PAL OVER
PAL OVER 70%
In 100A Is
Ii
70% In 100A Is
Ii
50/60Hz TL 50/60Hz TL
Ts Ts
Ip(xIr) Ip(xIr)
xIr) TS(S) Ii(X100A) Ir) TS(S) Ii(X100A)
8 10 8 10
5 6 .1 .2 6 .1 .2 6 12
6 12
7 7
8 .10 8 .10
4 14 .07 .3 4 14 .07
10 .06 .3 10 .06
Figure shows Lead-wire terminal block type (SLT). Figure shows Internal terminal type.
J2 J2
MITSUBISHI
J1 J1
OFF
D2 D2
Power control voltage
D1 D1
Breaker
햳 햴
햲
AC 100–120
AC 200–240
AC 220–240
AC 380–450 ≤ 30
쏹 AC 400–440
(50 / 60 Hz)
DC 24, DC 110
5 35–70 % U N
min. 85 % U N
AC 100–110/120–130
AC 200–220/230–250
AC 380–415/440–480 5–30
쏹 (50 / 60 Hz) (Instantaneous type)
DC100/110
햵
AC 100–120/200–240/380–450 5–35
쏹 AC 200–250/380–450/460–550 (Time delay type with
(50 / 60 Hz) 3 voltage inputs)
햲
Also for DSN types.
햳
Other voltages on request.
햴
The operating time is the time from the start of operating the breaker since the undervoltage trip went from voltage to no-voltage condition.
햵
DC version on request.
UVTs with Time delay on request.
30 MITSUBISHI ELECTRIC
Types of UVTs
3 UVTNA450-05SWRSU30 UVTNA550-05SWRSU030
4 UVTNA450-05SWRFSU30 UVTNA550-05SWRFSU30
3 UVTSA450-2GSWRSU30 UVTSA550-2GSWRSU30
4 UVTSA450-2GSWRFSU30 UVTSA550-2GSWRFSU30
MITSUBISHI ELECTRIC 31
AC 24 / 48 V AC 24 / 48 V
AC 100–110 / 120–130 V AC 100–110 / 120–130 V
AC 200–220 / 230–250 V AC 200–220 / 230–250 V
NF/DSN32–63 AC 380–415 / 440–480V NF/DSN 63 AC 380–415 / 440–480V
AC 500–550 / 600 V AC 500–550 / 600 V
DC 24 / 48 V DC 24 / 48 V
DC 110 / 125 V DC 110 / 125 V
AC 24 / 48 V AC 24 / 48 V
AC 100–110 / 120–130 V AC 100–110 / 120–130 V
AC 200–220 / 230–250 V AC 200–220 / 230–250 V
AC 380–415 / 440–480V AC 380–415 / 440–480 V
NF/DSN125–250 NF/DSN125–250
AC 500–550 / 600 V AC 500–550 / 600 V
DC 24 / 48 V DC 24 / 48 V
DC 100 / 110 V DC 100 / 110 V
DC 110 / 125 V DC 110 / 125 V
AC 100–110 / 120–130 V
AC 200–220 / 230–250 V
NF/DSN1000–1600 AC 380–415 / 440–480 V
DC 24 / 48 V
DC 100 / 110 V
AC 24 / 48 V
AC 100–110 / 120–130 V
AC 200–220 / 230–250 V
AC 380–415 / 440–480 V
NF/DSN125–250
AC 500–550 / 600 V
DC 24 / 48 V
DC 100 / 110 V
DC 110 / 125 V
UVT
햲
...: non-synchronous closing type
UVTfor ...:
synchronous closing closing
synchronous on requesttype
32 MITSUBISHI ELECTRIC
AC 24 / 48 V AC 24 / 48 V
AC 100–120 / 200–240 / AC 100–120 / 200–240 /
380–450 V 380–450 V
AC 200–250 / 380–450 / AC 200–250 / 380–450 /
NF/DSN32–63 460–550 V NF/DSN32–63 460–550 V
AC 380–450 / 460–550 / AC 380–450 / 460–550 /
600–690 V 600–690 V
DC 24 / 48 V DC 24 / 48 V
DC 100–110 V DC 100–110 V
AC 24 / 48 V AC 24 / 48 V
AC 100–120 / 200–240 / AC 100–120 / 200–240 /
380–450 V 380–450 V
AC 200–250 / 380–450 / AC 200–250 / 380–450 /
NF/DSN125–250 460–550 V NF/DSN125–250 460–550 V
AC 380–450 / 460–550 / AC 380–450 / 460–550 /
600–690 V 600–690 V
DC 24 / 48 V DC 24 / 48 V
DC 100 / 110 V DC 100 / 110 V
AC 24 / 48 V
AC 100–120 / 200–240 /
380–450 V
AC 200–250 / 380–450 /
NF/DSN125–250 460–550 V
AC 380–450 / 460–550 /
600–690 V
DC 24 / 48 V
DC 100–110 V
MITSUBISHI ELECTRIC 33
AC 100–120 / 200–240 /
380–450
NF/DSN1000–1600
AC 200–250 / 380–450 /
460–550 V
AC 100–120 / 200–240 /
380–450 V
NF/DSN125–250
AC 200–250 / 380–450 /
460–550 V
34 MITSUBISHI ELECTRIC
If no connection method is specified with The front-connection model can be modi- More details on request.
the order, we deliver the standard fixed- fied to other types (excluding plug-in)
installation type with front connection. with special purchase options.
IEC60947-2 EN60947-2
Appearance
500VAC
36/36kA EN60947-2
440VAC IEC60947-2
36/36kA
In 100A 380/415VAC
230VAC
85/85kA MITSUBISHI OFF JIS C 8201-2
40°C
Icu/Ics
300VAC
20/20kA NO-FUSE BREAKER Ue
690VAC
8/8kA
Ir 63-100A MODEL 22/22kA
3P NF125-SGW 525VAC
30/30kA
POLE 500VAC
36/36kA
Ui690V Uimp 8kV 440VAC
36/36kA
PUSH TO TRIP
MITSUBISHI ELECTRIC Ir 63-100A MITSUBISHI OFF JIS C 8201-2
40°C
Icu/Ics
POLE
3P NO-FUSE BREAKER Ue
690VAC
8/8kA
Uimp 8kV MODEL 22/22kA
Ui690V NF125-SGW 525VAC
Cat.A ON 500VAC
440VAC
30/30kA
36/36kA
T Ir 36/36kA
MODEL
RE100 In 100A
50/60Hz
Ip
TL
Is
Ii
70% PAL OVER
PUSH TO TRIP
MITSUBISHI ELECTRIC In 100A 380/415VAC
230VAC
85/85kA
20/20kA
Ts 300VAC
TS(S) Ii(X100A)
Ip(xIr) Ir 63-100A
TL(S) IS(xIr) 8 3P
Ir(A) 10
POLE
4 5 6 .1 .2 6 12
80 3.5
60 80
3
7
Ui690V Uimp 8kV
T Ir
63 100 12 100
2.5
2
8
10 .06 .3 4 14 .07 .10
MODEL
RE100 In 100A
Ip
Is
Ii
70% PAL OVER Cat.A ON
50/60Hz TL
Ts
Ip(xIr)
PUSH TO TRIP
MITSUBISHI ELECTRIC
IS(xIr) TS(S) Ii(X100A)
Ir(A) TL(S) 8 10
4 5 6 .1 .2 6 12
80 3.5
60 80 7
3
8 .10
2.5 .3 4 14 .07
100 2 10 .06
63 100 12
T Ir
MODEL Ip
70% PAL OVER
RE100 In 100A Is
Ii
50/60Hz TL
Ts
Ip(xIr)
IS(xIr) TS(S) Ii(X100A)
Ir(A) TL(S) 8 10
4 5 6 .1 .2 6 12
80 3.5
60 80 7
3
8 .10
2.5 .3 4 14 .07
100 2 10 .06
63 100 12
32–250 A 쏹 쏹 쏹햲 쏹
400–800 A 쏹 쏹 — 쏹
쏹
햳 햳
1000–1600 A — — —
햲 햳
Only for frame sizes 125/160/250 A On request, modified at factory.
왎 Connection Accessories
3 3
NF/DSN32–63 NF/DSN32–63 —
4 4
3 3
NF/DSN125–250 NF/DSN125–250 IP 20
4 4
3 3
NF/DSN400 NF/DSN400 —
4 4
3 3
NF/DSN630 NF/DSN630 —
4 4
3 3
NF/DSN800 NF/DSN800 —
4 4
Solderless terminals SL
3 1 Set = 3 pcs.
NF/DSN125–250 2.5–185 mm² Cu/Al
4 1 Set = 4 pcs.
MITSUBISHI ELECTRIC 35
Cat.A ON
PUSH TO TRIP
MITSUBISHI ELECTRIC
MODEL
RE100 In 100A
50/60Hz
T
Ip
TL
Ir
Ts
Is
Ii
70% PAL OVER
The V-type operating handle is available in the following colour
combinations:
Ip(xIr)
IS(xIr) TS(S) Ii(X100A)
Ir(A) TL(S) 8 10
4 5 6 .1 .2 6 12
80 3.5
60 80 7
3
8 .10
2.5 .3 4 14 .07
100 2 10 .06
63 100 12
RE
PUSH
TO
Example:
TRIP
cabinet door
ED
8/8kA
690VAC
22/22kA
MODEL
NF125-SGW 525VAC
30/30kA
P
500VAC
36/36kA
IP
440VAC
36/36kA
100A
combinations:
380/415VAC
TR
In 230VAC
85/85kA
20/20kA
300VAC
Ir 63-100A
3P
POLE
Uimp 8kV
PUSH TO TRIP
MITSUBISHI ELECTRIC
T Ir
MODEL Ip OVER
RE100 RE In 100A Is
Ii
70% PAL
50/60Hz TL
Ts
PU Ip(xIr)
IS(xIr) TS(S)
SH Ii(X100A)
Ir(A) TL(S) TO 8 10
80 3.5
4 5 6 TR
.1 IP .2 6 12
60 80 7
3
8 .10
2.5 .3 4 14 .07
100 2 10 .06
63 100 12
36 MITSUBISHI ELECTRIC
앬 The handle lock HL type can be used for 3- and 4-pole breaker
types.
앬 The handle locks can be used without padlock as lock covers.
앬 The HLF types are used for OFF-lock and the HLN types are
used for ON-lock.
앬 The handle lock HLF3 type enables the user to lock the handle
with up to three padlocks against switching.
앬 The HLS types are used for OFF-lock only.
HLS-2GSW
NF/DSN32–63
NF/DSN125–250
NF/DSN32–63
NF/DSN125–250
NF/DSN125–250
HLF3-2GSW
NF/DSN32–63
NF/DSN125–250
NF/DSN32–63
NF/DSN125–250
NF/DSN400–800
NF/DSN100–1600
HL-4SW
MITSUBISHI ELECTRIC 37
IEC60947-2 EN60947-2
OFF
550VAC
In 100A 380/415VAC
230VAC
85/85kA
20/20kA
NO-FUSE BREAKER 460VAC
220VAC
50kA
85kA
300VAC
Ir 63-100A MODEL
NF400-SEP IEC 60947-2
3P EN 60947-2
POLE Icu/Ics
400A
OFF
S4
ON 30/30kA
K1
K2
K2
P2 Uc
Supply
42/42kA
K3
P1
Cat.A SW1 Power
Uc K2
K3
K3
Circuit
Operating 45/45kA
S2 S4 3P 85/85kA
POLE
400
S1
MITSUBISHI ELECTRIC 40°C
P1 P2
PUSH TO TRIP Ui 690VAC
50 - 60Hz
50kA
8kV 500VAC 85kA
Uimp 250VAC
MODEL
In 100A
T
Ip
Ir
Is 70% PAL OVER
Control circuit
ON
RE100 Ii
50/60Hz TL
Ts voltage should be
IS(xIr) TS(S) Ii(X100A)
Ip(xIr)
supplied to P1
TL(S)
Ir(A)
4 5 6 .2
8 10
and P2 terminals.
80 .1 6 12
60 80 3.5 7
3
8 .10
2.5 .3 4 14 .07 PUSH TO TRIP
100 2 10 .06
63 100 12 MITSUBISHI ELECTRIC
P2 S1 S2 S4
P1 300 4 5 6
8 10
250
350 3.5 7 6 12
220 3 14
2.5 8
10 4 16
200 400 2
xIr) Ii(X400A)
Ir(A) IS(xI
IS(xIr)
TEST .1 .2
60 80
T Ir .10
100 .06 .3 .07
Ip 12
Is xIr)
Ip(xI
Ip(xIr)
Ii c)
sec)
TL(se
TL(sec) TS(sec)
sec)
TS(sec)
TL
Ts
MODEL MSDBA-NF25GSW
MITSUBISHI A0106 햳
POWER SUPPLY MODULE SERIAL:
NO-FUSE BREAKER ON
MODEL NF250-SGW
50/60Hz
Uimp 8kV
Ui 690V
Push to Cat.A
EN60947-2
IEC60947-2
40°C
JIS C 8201-2 (MANU)
ON Ue
Icu/Ics
8/8kA
690VAC Dis-
22/22kA
525VAC charge
30/30kA
500VAC 햲
36/36kA
AUTO 440VAC
36/36kA
380/415VAC Push
Push to 230VAC
85/85kA
MITSUBISHI ELECTRIC
OPEN
(TRIP) RATED CURRENT
MANU
250 A
OFF
Rated operating voltage (V) DC 24 V AC 100/110 V, 200/220 V (AC 240 V) AC 100/110 V, 200/220 V (AC 240 V)
햳 DC48–60V
(allowable voltage range 85–110%) AC100–240V / DC100–250V DC 100/110 V (DC 125 V) DC 100/110 V (DC125 V)
DC 100 / 110 V 0.20 OFF: 1.0 (3.0) ON: 8.0 OFF: 1.0 (3.0) ON: 9.0
Operating current
햴 100 / 110 V 0.50 OFF: 1.0 (3.0) ON: 10.0 OFF: 1.0 (3.0) ON: 10.0
(A, eff.) AC
200 / 200 V 0.35 OFF: 0.5 (1.5) ON: 8.0 OFF: 0.5 (1.5) ON: 8.0
ON operating 0.05–0.1 (self holding) 0.05 0.07
Operating time (sec.) OFF operating 0.6 and less (self holding) 3 and less (self holding) 3 and less (self holding)
Spring charging 1.2 and less — —
Transformer capacity required (VA) 150 700 700
Endurance voltage (V) 1500 1500 1500
햲
Also usable for Disconnectors DSN with 3 and 4 poles.
햳
The voltages in parentheses ( ) are special options and might require an external resistor. For details, consult your distributor.
햴
The values in parentheses ( ) show starting current.
앬 The motor operated types should not 앬 The current breaker position ON, OFF If the breaker is an auto reset type, it con-
be operated 10 times consecutively or TRIPPED will be shown with a special tains a built-in alarm switch and the
(one on/off counts as an operation). display on the motor. off-control circuit close when the breaker is
앬 The operating voltage should be 앬 The dielectric strength of the electrical tripped. Since the breaker automatically
between 85 – 110 % of the rated con- operating circuits is 1500 V. When per- resets itself after tripping, the power is eas-
trol voltage. forming a dielectric strength test ily restored by switching on the breaker
simultaneously with another device at again. With a UVT mounted, however, auto
a voltage over 1500 V, the operating reset may not be possible. In this case,
circuit terminal should be discon- please consult your distributor.
nected.
앬 More details on request.
38 MITSUBISHI ELECTRIC
OFF
S4
ON
S2
K1 K1
K1 S1
K2
K2
P2 Uc
K3
P1 Supply
SW1 Power
Uc K2
K3 Operating
K3
Circuit
S2 S4
S1
P1 P2
Control circuit
voltage should be
supplied to P1
and P2 terminals.
Spring-charged type Spring-charged type
P1 P2 S1 S2 S4 MDS.....-NF2GSWE MDS-4SW.... and
and breaker type NF250-SGW breaker type NF400-SEW
IEC60947-2 EN60947-2
TL
Ts
Is 525VAC
Ii
500VAC
70%
440VAC Ip(xIr)
PAL
22/22kA
OVER
30/30kA
36/36kA
charge
햲 ON
AUTO 36/36kA
TL(S) IS(xIr) TS(S) Ii(X100A)
380/415VAC Push
Ir(A)
80
60 80 3.5
4 5 6
7
.1Push to
.2 6
8 10
230VAC
12
85/85kA
MITSUBISHI ELECTRIC
3
2.5 8
10 .06
OPEN .3 4 14 .07 .10
100 2
63 100 12 (TRIP) RATED CURRENT PUSH TO TRIP
MANU MITSUBISHI ELECTRIC
250 A
300 8 10
4 5 6
250
350 3.5 7 6 12
220 3 14
2.5 8
10 4 16
200 400 2
xIr) Ii(X400A)
Ir(A) IS(xI
IS(xIr)
T Ir
OFF TEST 60 80 .1 .2
.3 .07 .10
Ip 12 100 .06
Is xIr)
Ip(xI
Ip(xIr)
Ii c)
sec)
TL(se
TL(sec) c)
sec)
TS(sec)
TS(se
TL
Ts
Automatic reset type requires the Automatic reset type requires the
Control power additional wiring shown by the Control power additional wiring shown by the
supply dotted lines. supply dotted lines.
DC 24 V
NF/DSN125–250 DC48–60V
AC100–240V / DC100–250V
AC 100–110 V
NF/DSN400–630 AC 230 V
DC 100–110 V
DC 100–110 V
NF/DSN800 AC 230 V
DC 100–110 V
AC 100–110 V
NF/DSN1000–1600 AC 230 V
DC 100–110 V
MITSUBISHI ELECTRIC 39
왎 Terminal Covers
Cat.A ON
PUSH TO TRIP
MITSUBISHI ELECTRIC
T Ir
MODEL Ip
70% PAL OVER
RE100 In 100A Is
Ii
50/60Hz TL
Ts
Ip(xIr)
IS(xIr) TS(S) Ii(X100A)
Ir(A) TL(S) 8 10
4 5 6 .1 .2 6 12
80 3.5
60 80 7
3
8 .10
2.5 .3 4 14 .07
100 2 10 .06
63 100 12
3 3
NF/DSN32–63 white IP20 NF/DSN125–250 transparent IP40
4 4
3
NF/DSN125–250 white IP40
4
3
NF/DSN32–63 white IP20
4
3 3
NF/DSN32–63 white IP20 NF/DSN125–250 white IP40
4 4
3 3
NF/DSN125–250 white IP40 NF/DSN400–630 transparent IP20
4 4
3 black 3
NF/DSN400–630 IP20 NF/DSN800 transparent IP20
4 transparent 4
3
NF/DSN800 transparent IP20
4
3
NF/DSN800 transparent IP20
4
3 NF/DSN1000–1250
(fixed with screws) transparent IP20 3
4 NF/DSN32–63 white IP20
4
3
NF/DSN125–250 white IP40
4
40 MITSUBISHI ELECTRIC
왎 Mechanical Interlock MI
(Front)
0A 440VAC
380/415VAC
36/36kA
36/36kA
In 100A 440VAC
380/415V
85/85kA 230VAC
00A 230VAC Ir 63-100A 300VAC
300VAC 20/20kA
3P POLE 3P
Uimp 8kV Ui690V Uimp 8kV
Cat.A
For use between two breakers of 125/160/250 AF 400 AF 630–800 AF 1000–1250 AF 1600 AF
MODEL T Ir MODEL T Ir
RE100 In 100A Ip
Is 70% PAL OVER
RE100 In 100A Ip
Is 70%
50/60Hz TL Ii 50/60Hz TL Ii
Ts Ts
Ir(A) TL(S) IS(xIr) TS(S) Ii(X100A) Ip(xIr) Ir(A) TL(S) IS(xIr) TS(S) Ii(X100A) Ip(x
0 4 5 6 8 10 80 4 5 6 8 10
60 80 3.5 .1 .2 6 60 80 3.5 .1 .2 6
3 7 12 3 7 12
2.5 8 2.5 8
100 12 100 2 10 .06 .3 4 14 .07 .10 63 100 12 100 2 10 .06 .3 4 14 .07
For use between two breakers of 125/160/250 AF 400 AF 630–800 AF 1000–1250 AF 1600 AF
barriers as standard.
In 230VAC
85/85kA
20/20kA
300VAC
Ir 63-100A
3P
POLE
Ui690V Uimp 8kV
Cat.A ON
PUSH TO TRIP
MITSUBISHI ELECTRIC
T Ir
MODEL Ip
70% PAL OVER
RE100 In 100A Is
Ii
50/60Hz TL
Ts
Ip(xIr)
IS(xIr) TS(S) Ii(X100A)
Ir(A) TL(S) 8 10
4 5 6 .1 .2 6 12
80 3.5
60 80 7
3
8 .10
2.5 .3 4 14 .07
100 2 10 .06
63 100 12
MITSUBISHI ELECTRIC 41
IEC60947-2 EN60947-2
Cat.A ON
PUSH TO TRIP
MITSUBISHI ELECTRIC
T Ir
MODEL
T
Ip PAL OVER
In 100A Is 70%
Ir(A)
80
60
RE100
TL(S)
80 3.5
IS(xIr)
4 5 6
50/60Hz
7
.1
TS(S)
.2
TL
6
8
Ts
Ii(X100A)
10
Ii
12
Ip(xIr)
for electronic breakers 100 A– 1600 A
3
8 .10
2.5 .3 4 14 .07
100 2 10 .06
63 100 12
000
L 30
POWER
ON
42 MITSUBISHI ELECTRIC
/// INDEX
MITSUBISHI ELECTRIC 43
MITSUBISHI ELECTRIC EUROPE B.V. TEHNIKON B:TECH, a. s. RIFAS UAB Sirius Trading & Services srl Euro Energy Components AB CBI Ltd.
25, Boulevard des Bouvets Oktyabrskaya 16/5, Off. 703-711 Headoffice, U Borové 69 Tinklu g. 29A Aleea Lacul Morii Nr. 3 Järnvägsgatan 36 Private Bag 2016
Phone: +33 (0)1 / 55 68 55 68 Phone: +375 (0)17 / 210 46 26 Phone: +420 569 777 777 Phone: +370 (0)45 / 582 728 Phone: +40 (0)21 / 430 40 06 Phone: +46 (0)300 / 69 00 40 Phone: + 27 (0)11 / 928 2000
MITSUBISHI ELECTRIC EUROPE B.V. Koning & Hartman B.V. Antonios Drepanias S.A. INTEHSIS srl CONSYS TRIELEC AG
Gothaer Straße 8 Woluwelaan 31 52, Arkadias Str. bld. Traian 23/1 Promyshlennaya st. 42 Mühlentalstr. 136
Phone: +49 (0)2102 / 486-0 Phone: +32 (0)2 / 257 02 40 Phone: +30 210 / 578 1599 Phone: +373 (0)22 / 66 4242 Phone: +7 812 / 325 36 53 Phone: +41 (0)52 / 625 84 25
MITSUBISHI ELECTRIC EUROPE B.V. AutoCont C.S. Meltrade Ltd. IMTECH CRAFT GTS
Westgate Business Park, Ballymount Jelinkova 59/3 Fertő utca 14. Sluisjesdijk 155 Bulevar Svetog Cara Konstantina 80-86 Darulaceze Cad. No. 43 KAT.2
Phone: +353 (0)1 4198800 Phone: +420 (0)59 / 5691 150 Phone: +36 (0)1 / 431-9726 Phone: +31 (0)10 / 487 19 11 Phone:+381(0)18/292-24-4/5,523962 Phone: +90 (0)212 / 320 1640
MITSUBISHI ELECTRIC EUROPE B.V. AutoCont C.S. GINO Industries Ltd. SCANELEC AS CS MTrade Slovensko, s.r.o. CSC Automation Ltd.
Viale Colleoni 7 Technologická 374/6 26, Ophir street Leirvikasen 43B Vajanskeho 58 15, M. Raskova St., Fl. 10, Office 1010
Phone: +39 039 / 60 53 1 Phone: +420 595 691 150 Phone: +972 (0)4 / 867 06 56 Phone: +47 (0)55 / 50 60 00 Phone: +421 (0)33 / 7742 760 Phone: +380 (0)44 / 494 33 55
MITSUBISHI ELECTRIC EUROPE B.V. B:TECH A.S. Kazpromautomatics Ltd. MPL Technology Sp. z o.o. INEA d.o.o.
Carretera de Rubí 76-80 Na Ostrove 84 2, Scladskaya str. Ul. Krakowska 50 Stegne 11
Phone: +34 93 / 565 3131 Phone: +420 (0)569 / 408 841 Phone: +7 3212 / 50 11 50 Phone: +48 (0)12 / 630 47 00 Phone: +386 (0)1 / 513 8100
MITSUBISHI ELECTRIC EUROPE B.V.