RC Section: 15850 Manufacturer: B. Provide manufacturer’s standard ceiling air B. Manufacturer’s standard ceiling air diffusers
Para: 2.01 GAMMA LINE of size, shape, capacity and type indicated and
diffusers of size, shape, capacity and type indicated
International as required for complete installation are
Page# 10,11,14, .and as required for complete installation
P.O. Box :7071 attached.
16-18 & 24of 28 C. Ceiling Compatibility
Riyadh 12883
www.gammaline.com 1.Provide diffusers with border styles that are
Pay Item: 1. Diffusers with border styles that are
compatible with adjacent ceiling systems, and that
2-02.13.04.05. 2- compatible with adjacent ceiling systems, and
Supplier: are specifically manufactured to fit into ceiling
02.13.04.06 that are specifically manufactured to fit into COMPLY with RC
SAUDI AIRCON module with accurate fit and adequate support.
2-02.13.04.07 ceiling module with accurate fit and adequate specification
P.O Box: 11730
Refer to the Royal Commission’s Contract Drawings support. As per the RC Contract drawings and
.2-02.13.04.08 31961 Al-Jubail
and Specifications, for types of ceiling systems which specification.
.2-02.13.04.09 Industrial City
Kingdom of Saudi .will contain each type of ceiling air diffuser
:Drawing No Arabia D. Types
725-320-20UC-ME- Tel:+966-13-3408700 Provide ceiling diffusers of type, capacity, and .1 Technical Data and schedules are attached.
220 fax: +966-13-3408539 with accessories and finishes as listed on diffuser
schedule. The following requirements shall apply to
items when indicated by manufacturer and model
:number on schedule
Manufacturer: REGISTERS AND GRILLES 2.07 Proposed Models : SGII-N-VD for Registers
RC Section: 15850 GAMMA LINE A. Supply and return air grilles and register frames Proposed Model: SGII-N for Return Grill
Para: 2.01 International shall have overlap margin with sponge rubber
Page# 10,11,14, P.O. Box :7071 gasket, furnished with pierced screw holes and Register and Grilles 2.07
16-18 & 24of 28 Riyadh 12883 mounting screws. Supply and return registers shall a. Supply Register and return air grilles frames
www.gammaline.com be furnished with opposed blade volume control have overlap margin with sponge rubber
Pay Item: damper constructed of heavy gage galvanized steel gasket, furnished with pierced screw holes and
Supplier: and operated by key or arm from face of the mounting screws. Supply register furnished
2-02.13.04.05. 2- SAUDI AIRCON COMPLY with RC
02.13.04.06 register. If indicated in the Contract Drawings, the with opposed blade volume control damper specification
P.O Box: 11730 damper shall be furnished with spring closing and constructed of heavy gage galvanized steel and
2-02.13.04.07 31961 Al-Jubail .UL-listed fusible link for 71°C (160°F) operated by key or arm from face of the
.2-02.13.04.08 Industrial City register. The fire damper is furnished with
.2-02.13.04.09 Kingdom of Saudi spring closing and UL-listed fusible link for 71°C
Arabia C. Provide manufacturer’s standard registers and .(160°F) as per contract drawings
:Drawing No Tel:+966-13-3408700 grilles; of size, shape, capacity and type indicated C. manufacturers Standard registers and grills
725-320-20UC-ME- fax: +966-13-3408539 .and as required for complete installation .are attached as per the project requirement