You are on page 1of 2

REPLACEMENT CT TUBES

REDUCE REPLACEMENT COSTS


AND TOTAL COST OF OWNERSHIP

You can‘t afford to wait until your scanner fails to


consider your options. That‘s why we quickly deliver
quality CT tubes from one of our forward stocking Call AllParts Medical today
locations in the United States. +1 866.507.4793 or visit
We provide 24/7/365 customer service and technical
support you need to replace, install and calibrate your
dunlee.com to learn more
replacement CT tube.

DUNLEE GLASSWARE SOLUTIONS EXPERIENCE FOR THE


Glassware Solutions programs protect providers from unexpected FUTURE
CT tube replacement costs. Dunlee and AllParts Medical offer two Building on 100+ years of experience,
programs from which to choose based on your preference for CT Dunlee’s people, products, programs
tube failure risk: and partnerships have shaped how
diagnostic images are made. Dunlee
GLASSWARE SOLUTIONS PRO for those who prefer proactive remains at the forefront of medical
CT tube replacement and whose tolerance for scanner is down- imaging as an international leader in
time is zero. the research, design, and manufactu-
ring of high-performance CT tubes.
GLASSWARE SOLUTIONS for those who desire a flat monthly
“subscription” fee with no deductibles and unlimited CT tube
replacements over the life of the contract.
TubeType Ordering No. Focal Spot kHU Standard Warranty
General Electric
REEVO Series
REEVO240G 9896-055-96401 0.7 x 0.6 8,000 12 months, full
This 8.0 MHU CT tube is designed 0.9 x 0.9
as a replacement for use in
GE Discovery™, GE Lightspeed™ and
GE Optima™*

DA200 Series
DA200P40 4598-006-53451 0.9 x 0.7 6,300 12 months or 6,000
This 6.3 MHU CT tube is designed 1.2 x 1.1 patient exams, full
as a replacement for use in
GE Optima™*

DA200ULTRA 9896-055-88704 0.9 x 0.7 6,300 12 months, full


This 6.3 MHU CT tube is designed 1.2 x 1.1
as a replacement for use in
GE BrightSpeed™, GE Discovery™,
GE Lightspeed™ and GE Optima™*

DA165 Series
DA165NP 9896-055-83901 0.9 x 0.7 3,500 14,000 slices/90 days full,
This 3.5 MHU CT tube is designed as a 1.2 x 1.2 140,000 slices or
replacement for use in GE HiSpeed, 12 months pro-rated
GE BrightSpeed™ and GE Optima™*

DA135 Series
DA135 CT/e 9896-055-80800 0.7 x 0.6 2,000 8,000 slices/90 days full,
This 2.0 MHU CT tube is designed 80,000 slices or
as a replacement for use in GE Brivo™, 12 months pro-rated
GE HiSpeed and GE CT Dual™*

Siemens
S532/Akron Series
S532B/Akron B 9896-055-95702 0.5 x 0.7 5,300 100 %: 40,000 ss or
This 5.3 MHU CT tube is designed 0.6 x 1.3 6 months
as a replacement for use in 70 %: 80,000 ss or
Siemens SOMATOM* 8 months
40 %: 150,000 ss or
12 months

S532Q/Akron Q 9896-055-95902 0.5 x 0.7 5,300 100 %: 30,000 ss or


This 5.3 MHU CT tube is designed 0.8 x 1.2 6 months
as a replacement for use in 70 %: 60,000 ss or
Siemens SOMATOM* 8 months
40 %: 120,000 ss or
12 months
*The products listed may be trademarks of the OEM. For the latest information regarding
compatibility for CT tubes and scanners, please refer to our cross-reference guide.
Document No. 452299129131 vers 02

All rights are reserved. Reproduction in whole or in part is prohibited Contact us for further information and to find
without the prior written consent of the copyright holder. the tube best suited to your needs.

Dunlee reserves the right to make changes in specification and/or to dis- c/o AllParts Medical
continue any product at any time without notice or obligation and will not Tel: +1 866.507.4793 • apmsales@philips.com
be liable for any consequences resulting from the use of this publication. 400 Brick Church Park Dr • Nashville, TN 37207

Dunlee is a brand of the Philips Company Group dunlee.com

You might also like