You are on page 1of 10

DE S IG N E NVE LO PE 6 80 0 G 3 DU T Y PUMP | File No: 100.

617

AN D 1 STAN DBY, DOMESTIC WATER BOOSTER WITH


Date: april 19, 2019
Supersedes: 100.617

STANDBY | N 3 3 0 2 0 2s — N 3 9 0 3 0 2s | S U B M I T T A L
Date: june 27, 2017

Job: Representative:

Order by: Date:

Engineer: Submitted by: Date:

Contractor: Approved by: Date:

pump de sig n data moto r de sig n data


No. of pumps: Tag: hp: rpm: 3600
Total package capacity: USgpm (L/s) Frame size: Enclosure:  odp  tefc
Pump capacity: USgpm (L/s) Head: ft (m) Volts: Hertz: 60 Hz Phase: 3
Liquid: Viscosity: Efficiency: nema premium 12.12
Temperature: °f (°c) Specific gravity:

note: Test tolerance according to iso 9906 Grade 2b


±8% on measured flow and ±5% on measured head

o p tio nal h e ader fl an g e co n n ec tio n s co ntro l pan el s pecific atio n s


Suction  ansi 125/150 nema 4 type enclosure
Discharge  ansi 125/150  ansi 250/300 Low suction shutdown and auto re-start
Main disconnect with interlock
Fused motor protection
co n n ec tio n o rientatio n Fused control circuit transformer
Power on indication
Suction  Right
 Left
Motor run indication
Discharge  Right
 Left
Virtual h-o-a for each pump
No-flow shutdown and automatic alternation
Soft fill mode
drive data
Pressure setback mode
Enclosure: ul type 12 ul or csa labeled
emi/rfi control: Integrated filter designed to meet en61800-3 Field adjustable set points, alarms and timers
Harmonic suppression: Integrated dc link reactors Flash memory storage
Cooling: Fan-cooled through back channel No-flow pressure optimization
Ambient temperature: -10°c to +45°c up to 1000 meters
above sea level
(-14°f to +113°f, 3280 ft)
o p tio nal equipment
su bmi tta l Design envelope 6800 g
n330202s - n390302s 3 duty pumps & 1 standby, Domestic water booster with standby

design envelope capability data


envelope curve max flow max head best eff % each motor frame size
pump
number usgpm (L/s) ft (m) point (bep) motor hp odp tefc
 N3 3 0 2 0 2S VMS-10 02B 226.2 (14.27) 97.6 (29.7) 67.60% 2 — 5 6C
 N3 3 0 4 0 2S VMS-1004BE 206.2 (13.01) 196.4 (59.9) 67.60% 3 — 18 4TC
 N3 3 0 6 0 2S VMS-1006B 218.5 (13.79) 294.6 (89.8) 67.60% 5 — 18 4TC
 N3 3 0 9 0 2S VMS-1009B 218.3 (13.77) 444.4 (135.5) 67.60% 7.5 18 4TC —
 N3 312 0 2S VMS-1012B 218.3 (13.77) 592.6 (180.6) 67.60% 10 — 215TC
 N3 316 0 2S VMS-1016B 227.5 (14.35) 790.1 (240.8) 67.60% 15 215TC —
 N3 5 010 2S VMS-3201 556.5 (35.11) 88.6 (27.0) 68.70% 5 — 18 4TC
 N3 5 0 222S VMS-3202-2 556.5 (35.11) 148.8 (45.4) 68.70% 7.5 18 4TC —
 N3 5 0 3 22S VMS-3203-2 558.1 (35.21) 237.0 (72.2) 68.70% 10 — 215TC
 N3 5 0 4 3 2S VMS-3204-3 558.1 (35.21) 314.6 (95.9) 68.70% 15 215TC —
 N3 5 0 5 0 2S VMS-3205 549.2 (34.65) 449.9 (137.1) 68.70% 20 — 2 5 6TC
 N3 5 0 6 0 2S VMS-3206 555.9 (35.07) 546.1 (166.5) 68.70% 25 — 2 8 4TSC
 N3 6 010 2S VMS-4501E 833.3 (52.57) 116.7 (35.6) 83.10% 7.5 — 215TC
 N3 6 0 212S VMS-4502-1 839.6 (52.97) 200.4 (61.1) 83.10% 15 215TC —
 N3 6 0 3 22S VMS-4503-2 846.8 (53.42) 290.2 (88.5) 83.10% 20 — 2 5 6TC
 N3 6 0 5 0 2S VMS-4505 830.1 (52.37) 611.3 (186.3) 83.10% 40 — 3 24TSC
 N37010 2S VMS-6401E 1177.8 (74.31) 123.2 (37.6) 84.70% 10 — 215TC
 N370 212S VMS-6402-1 1217.5 (76.81) 226.6 (69.1) 84.70% 20 — 2 5 6TC
 N370 3 22S VMS-6403-2 1217.5 (76.81) 339.1 (103.4) 84.70% 30 — 2 8 6TSC
 N370 422S VMS-6404-2 1196.7 (75.50) 475.2 (144.8) 84.70% 40 — 3 24TSC
 N3 8 010 2S VMS-1501B 350.5 (22.11) 62.6 (19.1) 72.50% 2 5 6C —
 N3 8 0 3 0 2S VMS-1503BE 352.7 (22.25) 189.8 (57.9) 72.50% 5 — 18 4TC
 N3 8 0 4 0 2S VMS-1504BE 352.7 (22.25) 253.1 (77.1) 72.50% 7.5 — 215TC
 N3 8 0 5 0 2S VMS-1505B 350.7 (22.13) 316.4 (96.4) 72.50% 10 — 215TC
 N3 8 070 2S VMS-1507B 352.7 (22.25) 442.9 (135.0) 72.50% 15 215TC —
 N3 810 0 2S VMS-1510B 354.7 (22.38) 639.9 (195.0) 72.50% 20 — 2 5 6TC
 N3 9 0 2 0 2S VMS-2002B 393.8 (24.84) 143.5 (43.7) 73.00% 5 — 18 4TC
 N3 9 0 3 0 2S VMS-2003B 394.0 (24.86) 216.5 (66.0) 73.00% 7.5 18 4TC —

Notes:
1 nsf 61 and nsf 372 certified complete package assembly.
2 Standard right hand connection orientation illustrated, please
indicate alternate connection orientation, if required.
3 All pumps are equal.
4 Standard grooved header connections.
Optional flanged ansi 150# or 300# connections available.
5 Optional tank shipped loose, installed by others.
Design envelope 6800 g submit ta l
3 duty pumps & 1 standby, Domestic water booster with standby n330202s - n390302s

max working
booster a b c max d e f g h j j1 weight
pressure
model
inches (mm) psi (bar) lbs (kg)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 3 0 2 0 2S 232 (16) 1034 (469)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 3 0 4 0 2S 232 (16) 1123 (509)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 3 0 6 0 2S 232 (16) 1136 (515)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 3 0 9 0 2S 232 (16) 1374 (623)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 8.25
 N3 312 0 2S 363 (25) 1746 (792)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (210)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 8.25
 N3 316 0 2S 363 (25) 1914 (868)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (210)
96.48 39.63 62.70 8.06 86.61 22.72 7.87 31.50 9.00 9.00
 N3 5 010 2S 232 (16) 1722 (781)
(2451) (1007) (1592) (205) (2200) (577) (200) (800) (229) (229)
96.48 39.63 62.70 8.06 86.61 22.72 7.87 31.50 9.00 9.00
 N3 5 0 222S 232 (16) 1883 (854)
(2451) (1007) (1592) (205) (2200) (577) (200) (800) (229) (229)
96.48 39.63 62.70 8.06 86.61 22.72 7.87 31.50 9.00 9.00
 N3 5 0 3 22S 232 (16) 2407 (1092)
(2451) (1007) (1592) (205) (2200) (577) (200) (800) (229) (229)
96.48 39.63 62.70 8.06 86.61 22.72 7.87 31.50 9.00 9.00
 N3 5 0 4 3 2S 232 (16) 2487 (1128)
(2451) (1007) (1592) (205) (2200) (577) (200) (800) (229) (229)
96.48 41.63 62.70 8.06 86.61 22.72 7.87 31.50 9.00 10.00
 N3 5 0 5 0 2S 363 (25) 2942 (1334)
(2451) (1057) (1592) (205) (2200) (577) (200) (800) (229) (254)
96.48 41.63 63.40 8.06 86.61 22.72 7.87 31.50 9.00 10.00
 N3 5 0 6 0 2S 363 (25) 3795 (1722)
(2451) (1057) (1610) (205) (2200) (577) (200) (800) (229) (254)
96.78 43.85 62.70 9.44 86.61 22.72 7.87 31.50 13.50 13.50
 N3 6 010 2S 232 (16) 2104 (954)
(2458) (1114) (1592) (240) (2200) (577) (200) (800) (343) (343)
96.78 43.85 62.70 9.44 86.61 22.72 7.87 31.50 13.50 13.50
 N3 6 0 212S 232 (16) 2682 (1216)
(2458) (1114) (1592) (240) (2200) (577) (200) (800) (343) (343)
96.78 43.85 62.70 9.44 86.61 22.72 7.87 31.50 13.50 13.50
 N3 6 0 3 22S 232 (16) 3123 (1416)
(2458) (1114) (1592) (240) (2200) (577) (200) (800) (343) (343)
96.78 45.85 69.73 9.44 86.61 22.72 7.87 31.50 13.50 15.00
 N3 6 0 5 0 2S 363 (25) 5094 (2311)
(2458) (1165) (1771) (240) (2200) (577) (200) (800) (343) (381)
96.78 48.87 62.70 9.44 86.61 22.72 7.87 31.50 13.50 13.50
 N37010 2S 232 (16) 3193 (1448)
(2458) (1241) (1592) (240) (2200) (577) (200) (800) (343) (343)
96.78 48.87 62.70 9.44 86.61 22.72 7.87 31.50 13.50 13.50
 N370 212S 232 (16) 3680 (1669)
(2458) (1241) (1592) (240) (2200) (577) (200) (800) (343) (343)
96.78 48.87 62.70 9.44 86.61 22.72 7.87 31.50 13.50 13.50
 N370 3 22S 232 (16) 4576 (2076)
(2458) (1241) (1592) (240) (2200) (577) (200) (800) (343) (343)
96.78 51.44 66.03 9.44 86.61 22.72 7.87 31.50 13.50 15.00
 N370 422S 363 (25) 5554 (2519)
(2458) (1307) (1677) (240) (2200) (577) (200) (800) (343) (381)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 8 010 2S 232 (16) 1014 (460)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 8 0 3 0 2S 232 (16) 1165 (529)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 8 0 4 0 2S 232 (16) 1319 (598)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 8 0 5 0 2S 232 (16) 1669 (757)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 8 070 2S 232 (16) 1836 (833)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 8.25
 N3 810 0 2S 363 (25) 2249 (1020)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (210)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 9 0 2 0 2S 232 (16) 1085 (492)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)
85.65 30.70 61.42 6.19 78.74 16.81 3.94 27.56 7.50 7.50
 N3 9 0 3 0 2S 232 (16) 1307 (593)
(2176) (780) (1560) (157) (2000) (427) (100) (700) (191) (191)

Note:
All dimensions are inches (mm), tolerances are (+/-) ½" (12 mm) unless otherwise specified.
su bmi tta l Design envelope 6800 g
n330202s - n390302s 3 duty pumps & 1 standby, Domestic water booster with standby

performance curve - vms 10b

q [l/min]
0 50 100 150 200 250 300 400
280
900
p h h
[psi] [ft] vms 1016/15 hp vms 10b - 60 hz - 3450 rpm [m]
348 800 vms 1015/15 hp 240

vms 1014/15 hp
700
290
200
vms 1012/10 hp
600
vms 1011/10 hp

232 vms 1010/10 hp 160


500
vms 1009/7.5 hp

vms 1008/7.5 hp
174 400 120
vms 1007/7.5 hp

vms 1006/5 hp
300
116 vms 1005/5 hp 80

vms 1004/5 hp
200
vms 1003/3 hp
58 40
100 vms 1002/2 hp

vms 1001/1 hp

0 0 0
0 10 20 3 40 50 60 70 80 U.S.g.p.m.

0 2 4 6 8 10 12 14 16 18 20 q [m3/h]
80
1.5
% 60 [%]
p2 1
[hp] Single Impeller hp
0.5 40

0 20
0 10 20 3 40 50 60 70 80 U.S.g.p.m.
8
20
npsh npsh
[ft] 10 4 [m]

0 0
0 10 20 3 40 50 60 70 80 U.S.g.p.m.

note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
Design envelope 6800 g submit ta l
3 duty pumps & 1 standby, Domestic water booster with standby n330202s - n390302s

performance curve - vms 15b

q [l/min]
0 100 200 300 400 500
280
900
p h h
vms 1512b/25hp [m]
[psi] [ft] vms 15b - 60 hz - 3500 rpm
348 800
vms 1511b/25hp 240

vms 1510b/20hp
700
290
200
vms 1509b/20hp

600
vms 1508b/20hp
232 160
500 vms 1507b/15hp

vms 1506b/15hp
174 400 120
vms 1505b/10hp

300
vms 1504b/10hp
116 80

vms 1503b/7.5hp
200

vms 1502b/5hp
58 40
100
vms 1501b/2hp

0 0 0
0 20 40 60 80 100 120 U.S.g.p.m.

0 5 10 15 20 25 q [m3/h]
80
2.5
%
60 [%]
p2 2
[hp]
1.5 40
Single impeller hp
1 20
0 20 40 60 80 100 120 U.S.g.p.m.
8
20
npsh 4
npsh
[ft] 10 [m]
0 0
0 20 40 60 80 100 120 U.S.g.p.m.

note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
su bmi tta l Design envelope 6800 g
n330202s - n390302s 3 duty pumps & 1 standby, Domestic water booster with standby

performance curve - vms 20b

q [l/min]
0 100 200 300 400 500 600
280
900
p h h
[psi] [ft] vms 20b - 60 hz - 3450 rpm [m]
348 800 vms 2010/25 hp
240

vms 2009/25 hp
700
290
vms 2008/20 hp
200

600
vms 2007/20 hp
232 160
500
vms 2006/15 hp

174 400 vms 2005/15 hp


120

vms 2004/10 hp
300
116 80
vms 2003/7.5 hp

200
vms 2002/5 hp
58 40
100 vms 2001/3 hp

0 0 0
0 20 40 60 80 100 120 140 U.S.g.p.m.

40q [m /h]
3
0 5 10 15 20 25 30
3 80

%
60 [%]
p2 2.5
[hp]
2 40
Single Impeller hp
1.5 20
0 20 40 60 80 100 120 140 U.S.g.p.m.
12
30
npsh 8 npsh
20
[ft] 4
[m]
10
0 0
0 20 40 60 80 100 120 140 U.S.g.p.m.

note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
Design envelope 6800 g submit ta l
3 duty pumps & 1 standby, Domestic water booster with standby n330202s - n390302s

performance curve - vms 32

335 1100
H H
(m) (ft) vms 32 - 60 hz - 3500 rpm
304 1000 vms 3210-1
min. flow

274 900 vms 3209

244 800
vms 3208-3

vms 3207
213 700

vms 3206
183 600

vms 3205
152 500

122 400 20 6
vms 3204-3

vms 3203
91 300 15 4.5

nsph(m)
nsph(ft)
vms 3203-2

61 200 vms 3202-2 10 3

vms 3201
30 100 5 1.5
npsh
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200
us gpm

0 5 9 14 18 23 27 32 36 41 45
q m3/h
80
70
60
50
eff.% 40
30
20
10
0
0 20 40 60 80 100 120 140 160 180 200
us gpm

note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
su bmi tta l Design envelope 6800 g
n330202s - n390302s 3 duty pumps & 1 standby, Domestic water booster with standby

performance curve - vms 45

274 900
H H
(m) (ft)
vms 4507-2 vms 45 - 60 hz - 3500 rpm
244 800 min. flow

vms 4506

213 700

vms 4505
183 600

152 500
vms 4504-1

122 400 20 6
vms 4503

vms 4503-2

91 300 15 4.5

nsph(m)
nsph(ft)
vms 4502-1

61 200 10 3

vms 4501 npsh


30 100 5 1.5
vms 4501-1

0 0 0 0
0 50 100 150 200 250 300
us gpm

0 11 13 34 45 57 68
q m3/h
90
80
70
60
eff.% 50
40
30
20
10
0
0 50 100 150 200 250 300
us gpm

note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
Design envelope 6800 g submit ta l
3 duty pumps & 1 standby, Domestic water booster with standby n330202s - n390302s

performance curve - vms 64

183 600
H H vms 64 - 60 hz - 3500 rpm
(m) (ft) vms 6404 min. flow

152 500 vms 6404-2

vms 6403
122 400

vms 6403-2

91 300
vms 6402

vms 6402-1

61 200 20 6

vms 6401
15 4.5

nsph(m)
nsph(ft)
vms 6401-1
30 100 10 3

5 1.5
npsh

0 0 0 0
0 50 100 150 200 250 300 350 400 450
us gpm

0 11 13 34 45 57 68 80 91 102
q m /h 3

90
80
70
60
eff.% 50
40
30
20
10

0 50 100 150 200 250 300 350 400 450


us gpm

note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
su bmi tta l Design envelope 6800 g
n330202s - n390302s 3 duty pumps & 1 standby, Domestic water booster with standby

10

4
3 11 6
2
discharge
j1 connection
grooved
standard

c max 7
b
8
9 f
5
d
j
g suction
h 10 a connection
1 grooved
e standard

11
Models N330202S - N390302S

item description
1 Stainless steel suction header
12 2 Stainless steel discharge header
3 Pump with integrated ivs controls
4 Control panel with plc
5 Suction isolation valve
6 Grooved connection
7 Pressure gauge
8 Pressure transducer
9 Pressure gauge isolation valve
toronto
10 Stainless steel base and panel support
+1 416 755 2291
11 Plug pipe
buffalo
12 Flo-Trex valve
+1 716 693 8813

birmingham
+44 (0) 8444 145 145

manchester
+44 (0) 8444 145 145

bangalore
+91 (0) 80 4906 3555

shanghai
+86 21 3756 6696
a r m s t r o n g f lu i d t e c h n o lo g y
são paulo established 1934 a r m s t r o n g f lu i d t e c h n o lo g y. c o m
+55 11 4785 1330

You might also like