1. Installation place
2. System parameters
3. Pump performance
4. Datasheet
5. Bill of materials
The information provided in this document is the result of calculations based on statistical data and approximations.
Nastec disclaims any liability arising from errors.
Location
-13,46074 -76,17006 26 -6
Average daily solar irradiance [kWh/m^2/day] for 5,56 5,37 5,51 5,90 6,14 5,86 6,06 6,31 6,40 6,28 6,63 6,20 6,02
latitude tilted panels
Max daily ambient temperature [°C] 15,41 15,52 15,80 15,66 15,22 14,39 14,58 15,80 16,57 17,35 17,19 16,32 15,82
Min daily ambient temperature [°C] 10,07 10,04 10,13 9,55 7,75 5,75 4,79 6,02 8,04 9,61 10,09 10,40 8,52
Average daily temperature [°C] 12,74 12,78 12,97 12,61 11,49 10,07 9,69 10,91 12,31 13,48 13,64 13,36 12,17
The information provided in this document is the result of calculations based on statistical data and approximations.
Nastec disclaims any liability arising from errors.
Submersible
Dynamic Head
Internal Diameter
40 m
101,6 mm
90° Curves
Borehole Diameter
18 Inches
2
Check Valves
Sol a r pa nel s pecs 1
I mp 8.37 A
NOCT 46 °C
Admitted Power Losses Admitted Power Losses
TC -0.41 %/K
2 % 4 %
Orientation North
The information provided in this document is the result of calculations based on statistical data and approximations.
Nastec disclaims any liability arising from errors.
Sol a r pump
Manufacturer Nastec
Description VSP60-8
Sol a r pa nel s
Manufacturer Nastec
Wp 260 W
Vmp 31,4 V
Voc 38,4 V
Imp 8,37 A
Strings 4
Total panels 72
Monthly delivery
P1 Power 15302 W
500
Flow 72,81 m^3/h
400
Da i l y performa nce
m^3/day
The information provided in this document is the result of calculations based on statistical data and approximations.
Nastec disclaims any liability arising from errors.
January February
100 100
m^3/h
m^3/h
50 50
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 2 4 6 8 10 12 14 16 18 20 22
March April
100 100
m^3/h
m^3/h
50 50
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 2 4 6 8 10 12 14 16 18 20 22
May June
100 75
50
m^3/h
m^3/h
50
25
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 2 4 6 8 10 12 14 16 18 20 22
July August
75 75
50 50
m^3/h
m^3/h
25 25
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 2 4 6 8 10 12 14 16 18 20 22
September October
75 75
50 50
m^3/h
m^3/h
25 25
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 2 4 6 8 10 12 14 16 18 20 22
November December
75 75
50 50
m^3/h
m^3/h
25 25
0 0
0 2 4 6 8 10 12 14 16 18 20 22 0 2 4 6 8 10 12 14 16 18 20 22
The information provided in this document is the result of calculations based on statistical data and approximations.
Nastec disclaims any liability arising from errors.
The information provided in this document is the result of calculations based on statistical data and approximations.
Nastec disclaims any liability arising from errors.