Professional Documents
Culture Documents
Note: H= 40 meter
L= 200 meter
Q= 35-40 m3/hari
Parameter
Location: Indonesia, Saumlaki (8° South; 131° Water temperature: 25 °C
East)
Required daily output: 35 m³; Sizing for average month Dirt loss: 5,0 % Motor cable: 50 m
Pipe type: plastic, drawn/pressed, new: 0,007 mm Static head: 40 m Pipe length: 200 m
Output [m³]
Hourly values 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00
Output [m³/h]
Energy [kWh] 0,007 0,32 0,69 1,00 1,2 1,3 1,4 1,3 1,2 0,96 0,66 0,31 0,007
Irradiation [kWh/m²] 0,004 0,17 0,36 0,55 0,69 0,78 0,81 0,78 0,69 0,55 0,36 0,17 0,004
Ambient temp. [°C] 22 22 23 25 27 29 31 32 32 32 32 31 31
System characteristic
Wiring diagram
Sizing Layout
H (Static head): Vertical height from the dynamic water level to the highest point of delivery.
B (Drawdown): Lowering of water level depending on flow rate and recovery rate of the well.
D (Pipeline inner diameter)
L (Pipe length): Entire pipeline from the pump outlet to the point of delivery. Ellbows and armatures must be added as an
equivalent length of pipeline.
M (Motor cable): The cable between controller and pump unit.
T (Tilt angle): Angle of the PV generator surface from the horizontal plane.
System Overview
Head max. 70 m
Flow rate max. 7,6 m³/h
Technical Data
Controller PS2-1800
ƒControlling and monitoring
ƒControl inputs for dry running protection, remote control etc.
ƒProtected against reverse polarity, overload and overtemperature
ƒIntegrated MPPT (Maximum Power Point Tracking)
ƒBattery operation: Integrated low voltage disconnect
ƒIntegrated Sun Sensor
Standards
2006/42/EC, 2004/108/EC, 2006/95/EC
IEC/EN 61702:1995
The logos shown reflect the approvals that have been granted for this product family. Products are ordered and supplied with the approvals specific to the market
requirements.
**Vmp: MPP-voltage under Standard Test Conditions (STC): 1000 W/m² solar irradiance, 25 °C cell temperature
H1 = 352 mm A= 611 mm
H2 = 333 mm B= 185 mm
W1 = 207 mm C= 426 mm
W2 = 170 mm D= 96 mm
W3 = 164 mm E= 98 mm
D1 = 124 mm S= 1,5 in
Net weight
Controller 6,0 kg
Pump Unit 14 kg
Motor 7,0 kg
Pump End 6,5 kg
*Vmp: MPP-voltage under Standard Test Conditions (STC): 1000 W/m² solar irradiance, 25 °C cell temperature