Parameter
Location: Sudan, Khartoum (15° North; 32° East) Water temperature: 35 °C
Required daily output: 10 m³; Sizing for average month Dirt loss: 6.0 % Motor cable: 33 m
Pipe type: plastic Static head: 28 m Pipe length: 44 m
Output [m³]
Energy [kWh] 2.1 2.2 2.3 2.4 2.1 2.1 2.0 2.0 2.1 2.0 2.0 2.0 2.1
Irradiation [kWh/m²] 7.9 8.6 9.1 9.6 8.4 8.2 7.8 7.9 8.4 8.2 8.1 7.6 8.3
Rainfall [mm] 0 0 0 0 0.10 0.23 1.5 2.1 0.73 0.13 0 0 0.40
Ambient temp. [°C] 24 25 29 32 30 30 29 29 32 32 29 26 29
Hourly values 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00
Output [m³/h]
Energy [kWh] 0.031 0.12 0.17 0.20 0.21 0.22 0.22 0.22 0.21 0.19 0.16 0.11 0.030
Irradiation [kWh/m²] 0.11 0.43 0.64 0.78 0.86 0.89 0.90 0.89 0.86 0.78 0.64 0.43 0.11
Ambient temp. [°C] 24 24 25 27 29 31 33 34 34 34 34 33 33
Thursday, 20 October 2016
ﺗﺼﻤﯿﻢ ﻣﻨﻈﻮﻣﺔ ﻟﺮﻓﻊ اﻟﻤﯿﺎه اﻟﺠﻮﻓﯿﺔ
System characteristic
Wiring diagram
Thursday, 20 October 2016
ﺗﺼﻤﯿﻢ ﻣﻨﻈﻮﻣﺔ ﻟﺮﻓﻊ اﻟﻤﯿﺎه اﻟﺠﻮﻓﯿﺔ
System Layout
Sizing Layout
H (Static head): Vertical height from the dynamic water level to the highest point of delivery.
B (Drawdown): Lowering of water level depending on flow rate and recovery rate of the well.
D (Pipeline inner diameter)
L (Pipe length): Entire pipeline from the pump outlet to the point of delivery. Ellbows and armatures must be added as an
equivalent length of pipeline.
M (Motor cable): The cable between controller and pump unit.
T (Tilt angle): Angle of the PV generator surface from the horizontal plane.