You are on page 1of 2

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Masonry Shear Wall Design Based on TMS 402-16/13 & 2019 CBC (both ASD and SD)
INPUT DATA & DESIGN SUMMARY
SPECIAL INSPECTION ( 0=NO, 1=YES ) 1 Yes
(This option only for local jurisdiction amendments to the code, not part of TMS.)
TYPE OF MASONRY ( 1=CMU, 2=BRICK ) 1 CMU
MASONRY STRENGTH fm' = 3 ksi
REBAR YIELD STRESS fy = 60 ksi
ALLOWABLE 30% INCREASING ? (Yes or No, CBC 1605.3.2) Yes
SEISMIC PERFORMANCE CATEGORY D Seismic D
( C,D,E, 0=WIND, 5=GRAVITY)
MASONRY LAID IN RUNNING BOND ? (TMS 402 7.3.2.6) Yes
SERVICE AXIAL LOAD P= 300 kips, at middle of Lw

SERVICE SHEAR LOAD Vx = 190 kips, (in-plane force)


SERVICE MOMENT LOAD Mx = 6200 ft-kips, (top flange, bf1, compression)
My = 500 ft-kips, (out-of-plane, left b11 & b21, compression)

EFFECTIVE HEIGHT OF WALL hw = 16 ft


LENGTH OF SHEAR WALL Lw = 30 ft, (within vertical control joints)
THE WALL DESIGN IS ADEQUATE.
THICKNESS OF WALL tw = 8 in
REINFORCING OF WALL 2 # 6 at each ends, with 8 in center to edge.
Ash, Horizontal 1 # 6 @ 16 in o.c.
Asv, Vertical 1 # 6 @ 24 in o.c.

TOP FLANGE (COMPRESSION) b11 = 48 in , b12 = 24 in , bf1 = 80 in ,(TMS 402 5.1.1.2.3)


tf1 = 12 in , 2 # 5 @ 48 in o.c., Vertical

BOTTOM FLANGE b21 = 36 in , b22 = 48 in , bf2 = 92 in ,(TMS 402 5.1.1.2.3)


tf2 = 8 in , 2 # 5 @ 48 in o.c., Vertical

ANALYSIS
CHECK FLEXURAL & AXIAL CAPACITY BY ALLOWABLE STRESS DESIGN (ASD)




P (k)


0
0 1 1 2 2 3

-


M (ft-k)

P (load) = 300 kips < P (allowable) = Pa = 2069.557 kips


M (resultant) = (Mx2 + My2)0.5 = 6220.129 ft-kips < M (allowable) = 7571.528 ft-kips [Satisfactory]
Where Em = 2700 ksi, (TMS 402 4.2.2.2.1) An = 4235 in2
Es = 29000 ksi, (TMS 402 4.2.2.1) Ast = 9.94 in2
Scale Factor = 1.333 , (TMS 402-11 2.1.2) fs ≥ 0 ksi, (TMS 402 8.3.3.3)
Fb = 1.320 ksi, (TMS 402 8-18) h/r= 87 , neglected conservatively flanges.
Fs = 32.00 ksi, (TMS 402 8.3.3.1) Pa = 2069.557 kips, (TMS 402 8.3.4.2.1)
(cont'd)
CHECK FLEXURAL & AXIAL CAPACITY BY STRENGTH DESIGN (SD)

1
f Pn
(k)


0
-1 0 1 2 3 4 5 6



f Mn (ft-k)

Pu = 1.2 P = 360 kips < fPn = 4729.013 kips, (TMS 402 9.3.4.1.1)
Mu = (1/0.7) (Mx2 + My2)0.5 = 8885.898 ft-kips < fMn = 12763.3 ft-kips, at Pu level.
[Satisfactory]
Where emu = 0.0025 , (TMS 402 9.3.2.c) d= 363 in
f= 0.9 , (TMS 402 9.1.4.1) fm' = 3 ksi

CHECK SHEAR CAPACITY


 (ASD), (TMS 402 8.3.6)

 1   P d 1    P  
 MAX  SF    4  1.75MIN 1 , M T   f m  0.25   0.5 A v F s ,  SF   4  1.75MIN 1 , M T   f m  0.25  
' '

Fv  4   Vd   An  A ns 2   Vd   A n  

= 106 psi > 1.5 fv = 104 psi [Satisfactory]


(factor 1.5 from TMS 402 7.3.2.6.1.2)

  4 M  
  SF  MIN 3 , MAX  2 , 2  1  T   
'
fm
Fv, Maximum   3 Vd   
146 psi > 1.5 fv
[Satisfactory]

CHECK MINIMUM REINFORCEMENTS


Ash,min = 0.064 in2/ft < Ash,actual = 0.330 in2/ft [Satisfactory] (TMS 402 7.3.2.6)
Ssh,max = 48 in > Ssh,actual = 16 in [Satisfactory] (TMS 402 7.3.2.6)
Asv,min = 0.064 in /ft
2
< Asv,actual = 0.220 in /ft
2
[Satisfactory] (TMS 402 7.3.2.6)
Ssv,max = 48 in > Ssv,actual = 24 in [Satisfactory] (TMS 402 7.3.2.6)
Atotal,min = 0.183 in2/ft < Atotal,actual = 0.550 in2/ft [Satisfactory] (TMS 402 7.3.2.6)

CHECK MAXIMUM REINFORCEMENT


' PERCENTAGE
nfm
 max  
 f 
2 f y  n  'y 
 f m 0.0087 > r= 0.0003 [Satisfactory]

(TMS 402 8.3.4.4)