Professional Documents
Culture Documents
Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.
EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.
FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability
CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)
Unidirectional Bidirectional
MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump
Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated
COMBINATION CONTROLS
LINES MEASUREMENT
Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow
Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
111-7898 3E-5179
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Part Number: for 1
Connector Plug
2
Ground (Wired): This indicates that the component is connected to a grounded wire.
The grounded wire is fastened to the machine. Receptacle
Plug
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
It is grounded by being fastened to the machine.
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. 325-AG135 PK-14
Harness identification code:
The electromagnet can open or close the switch part of the relay. Wire Gauge*
This example indicates wire group 325,
wire 135 in harness "AG". Wire Color
Solenoid: A solenoid is an electrical component that is activated by electricity. *Wire gauge is shown in AWG (American Wire Gauge)
It has a coil that makes an electromagnet when current flows through it. but could also be shown in metric denoted with mm
The electromagnet can open or close a valve or move a piece of metal that can do work. Deutsch connector: Typical representation
1
of a Deutsch connector. The plug contains all
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a 2 sockets and the receptacle contains all pins.
permanent magnet. It has two coils (latch and unlatch) that make electromagnet Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places 1
of a Sure-Seal connector. The plug and receptacle
the latch coil circuit open at the time the coil latches. 2 contain both pins and sockets.
RENR9980-08
November 2019
© 2019 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Yellow,” the “Power Edge”
and Cat “Modern Hex” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION
Schematic Machine
Description
Location Location
Accumulator Gp A-5 1
Cylinder Gp - Boom E-2 2
Cylinder Gp - Bucket E-7 3
Cylinder Gp - Stick E-7 4
Filter Gp - Oil (Case Drain) A-5 5
Filter Gp - Oil (Hydraulic Return) A-6 6
Filter Gp - Oil (Pilot) A-4 7
Manifold Gp - Control (Pilot Oil) A-6 8
Motor Gp - Hydraulic Fan A-7 9
Motor Gp - Swing E-5 10
Motor Gp - Travel (Left) E-5 11
Motor Gp - Travel (Right) E-3 12
Pump Gp - Hydraulic Fan B-3 13
Pump Gp - Main B-2 14
Sensor As - Pressure (Hydraulic Pump #1 Outlet) D-4 30
Sensor As - Pressure (Hydraulic Pump #2 Outlet) A-7 31
Switch As - Pressure (Implement, Swing) D-6 32
Switch As - Pressure (Travel, LH) D-2 33
Switch As - Pressure (Travel, RH) C-5 34
Swivel Gp A-2 15
Valve Gp - Check (Oil Cooler Bypass) B-2 16
Valve Gp - Cushion (Crossover Relief) B-7 17
Valve Gp - Load Control (Boom Drift Red, Relief Line) D-7 18
Valve Gp - Load Control (Stick Drift Red, Relief Line) D-7 19
Valve Gp - Main Control C-2 20
Valve Gp - Pilot (Travel) D-7 21
Valve Gp - Pilot Control (Left Joystick) C-7 22
Valve Gp - Pilot Control (Right Joystick) C-6 23
Valve Gp - Pressure Reducing (Boom, Swing Priority) B-4 24
Valve Gp - Shuttle B-7 25
Valve Gp - Shuttle B-4 26
Valve Gp - Solenoid (Heavy Lift) A-4 27
Valve Gp - Travel (Counterbalance) (Left) D-5 28
Valve Gp - Travel (Counterbalance) (Right) D-3 29
TAP LOCATION
Tap Schematic
Description
Number Location
AA Pilot Filter Pressure Test Port A-6
BB Drive Pump Pressure Test Port B-2
CC Power Shift Pressure Test Port A-2
DD Idler Pump Pressure Test Port A-2
SOS Hydraulic Oil Sampling Port A-5
7 6 5 4 3 2 1
(10) MOTOR GP
PG SWING
(3) CYLINDER GP 200-3373
(4) CYLINDER GP DR
BUCKET STICK (12) MOTOR GP (2) CYLINDER GP
357-9767 R.C.V.-C (11) MOTOR GP TRAVEL (RIGHT)
357-4704 BOOM
TRAVEL (LEFT) 271-6376 358-5973
MU 271-6376
BG AG
E E
Pp3 Pp3
T1
B1 A1 T1
T2
T2
B A
A B B A
BL2 AL2
(28) VALVE GP (29) VALVE GP
(21) VALVE GP TRAVEL (COUNTERBALANCE) (LEFT) TRAVEL COUNTERBALANCE (RIGHT)
PILOT (TRAVEL) (17) VALVE GP 204-2819 204-2819
310-0414 CUSHION (CROSSOVER RELIEF) BL1 AL1 BR1 AR1
TP 322-8716
TT (15) SWIVEL GP
TRAVEL (L) TRAVEL (R) 234-4440
D D
(18) VALVE GP
LOAD CONTROL
BACK FWD FWD BACK (BOOM DRIFT RED, RELIEF LINE)
T1 T5 T2 T4 T6 T3 255-5683
aL1 bL1 bR1 aR1 (19) VALVE GP
LOAD CONTROL BL3 AL3 BR4
(34) SWITCH AS (STICK DRIFT RED,
BDr
SP3 SPi SP2 BP3 BPi BP2
(33) SWITCH AS PRESSURE RELIEF LINE)
PRESSURE (TRAVEL, RH) 255-5680 SDr aL2 aL1
AR4
(TRAVEL, LH) 309-5769
309-5769 R.C.V.: B
AL2 AL1 AR1 aR3 aR4
AR5
BR5
aR5
AL4
IN aL3
T aL4 SP1 ST Di4 Pi4 aR2 BR2 AR2 Pi1 BP1 BT R3 MAIN CONTROL
(22) VALVE GP
(23) VALVE GP UP BL3 R2 BACK DOWN BR4 R1 IN 285-1345
BACK
CLOSE
PILOT CONTROL LINE PATTERNS
C (LEFT JOYSTICK) PILOT CONTROL C
Pressure Line
297-0533 (RIGHT JOYSTICK)
297-0532 Pilot / Load Sensing Pressure
JLP JRT
Drain / Return Lines
JLT JRP
STICK SWING BUCKET BOOM Air Line
Component Group
CALLOUTS
YY Taps (Pressure, Sampling, Sensor - by letter)
OUT IN R L OPEN CLOSE DOWN UP DL DL D Connectors (By letter)
BOOM (2)
(R)
TRAVEL
STICK (1)
SWING
ATCH
BUCKET
BOOM (1)
STICK (2)
TRAVEL (L)
Callout Number Component
(Machine Location from (52) VALVE GP - CONTROL Name
Component LocationsTable)
138-1234 Part Number
260-2180
#2 (SWING)
C PRESSURE (IMPLEMENT, T B a1
310-0210
B SWING) P1 P2 M1
BB
A G 309-5769 (27) VALVE GP
SOLENOID
RIGHT Psv
P1 (HEAVY LIFT) S
PUMP
R.C.V.: A DE F A 121-6303 CC
(16) VALVE GP PAC
a3
CHECK (OIL COOLER BYPASS) (6) FILTER GP (7) FILTER GP
190-7745 OIL (HYDRAULIC RETURN) DR3 DR4 Pi2 DR5 T-OUT1 DR6 (1) ACCUMULATOR GP T P OIL (PILOT) LEFT M2 Do not operate or work on this product unless you have
188-4140 164-6981 158-8987 PUMP DD read and understood the instruction and warnings in the
DR
Dr1
tions or heed the warnings could result in injury or
(5) FILTER GP OUT IN (30) SENSOR AS -
A OIL (CASE DRAIN)
death. Proper care is your responsibility.
A
PRESSURE
289-8194 T PL (HYDRULIC PUMP #1 OUTLET)
(9) MOTOR GP 260-2180
PG PC
HYDRAULIC FAN THIS SCHEMATIC IS FOR THE 330D, 336D AND 336D2 EXCAVATOR, AND 336D MHPU
234-4638 B A HYDRAULIC SYSTEM / WITH HEAVY LIFT AND FINE SWING
AA SOS HL
MEDIA NUMBER: RENR9980-08
Pi2 SCHEMATIC PART NUMBER: 259-7414, CHANGE: 02, VERSION: HE
Components are shown installed on a fully operable machine with the key and engine off.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.
7 6 5 4 3 2 1
FILTERS
VIEW ALL CALLOUTS
SOS AA
7
MACHINE COMPONENT LOCATIONS
VIEW ALL CALLOUTS
32 25 22 23 33 21 34 4
8 26
2
16
24
27 14 13 17
MOTOR GP - SWING AND SWIVEL
VIEW ALL CALLOUTS
10
15
MOTOR GP - TRAVEL
VIEW ALL CALLOUTS
28
29
11
BB CC 5
31 9 DD 30
VALVE GP - MAIN CONTROL
VIEW ALL CALLOUTS
20 18 19