INTERACTIVE SCHEMATIC

Bookmarks X
*This document is best viewed at a
Options
screen resolution of 1024 X 768.
Features
Cover Page
To set your screen resolution do the following:
Tables RIGHT CLICK on the DESKTOP.
Component Select PROPERTIES.
Connector
CLICK the SETTINGS TAB.
Schematic
Machine Views
MOVE THE SLIDER under SCREEN RESOLUTION
Chassis View until it shows 1024 X 768.
Cab View CLICK OK to apply the resolution.
Engine View
*Due to different monitor sizes and PDF reader preferences
The Bookmarks panel will allow you to there may be some variance in linked schematic locations
quickly navigate to points of interest.

Click here to save a copy of


EC-C2 E-C60 this interactive schematic
EC-C3
to your desktop
E-C61

VIEW ALL CALLOUTS

EC-C1
When only one callout is showing on a
machine view, clicking on this button will
Click on any text that is BLUE and make all of the callouts visible. This
underlined. These are hyperlinks button is located in the top right corner
that can be used to navigate the of every machine view page.
schematic and machine views.

ELECTRICAL SYMBOLS BASIC HYDRAULIC


HOTKEYS (Keyboard Shortcuts) COMPONENT SYMBOLS
T

Pressure Temperature Level Flow


Pump

FUNCTION KEYS
Switch Switch Switch Switch Circuit Breaker
or Motor Variability

Click here to view the


Zoom In “CTRL” / “+” Schematic Symbols
Fluid
Conditioner
Spring
(Adjustable)

Zoom Out “CTRL” / “-” and Definitions page

Fit to Page “CTRL” / “0” (zero)


Hand Tool “SPACEBAR” (hold down)
Find “CTRL” / “F”
Search “CTRL” / “SHIFT” / “F”
SCHEMATIC SYMBOLS AND DEFINITIONS

VALVES INTERNAL PASSAGEWAYS PUMPS BASIC HYDRAULIC


ENVELOPES FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
PARALLEL
FLOW
CROSS
FLOW
FIXED DISPLACEMENT
COMPONENT SYMBOLS

One Position Two Position Three Position Unidirectional Bidirectional Pump


Infinite Two Three Variability
Positioning Position Position or Motor
PORTS VARIABLE DISPLACEMENT
NON- COMPENSATED

CYLINDERS Fluid Spring


(Adjustable)
Two-way Three-Way Four-Way Conditioner
Unidirectional Bidirectional
CONTROL
AB AB
Single Acting Double Acting
MOTORS Pressure
FIXED DISPLACEMENT Spring
P T P T Compensation
Normal Position Shifted Position Infinite Position

CHECK
Control
ACCUMULATORS Unidirectional Bidirectional
Valves
Line Restriction
(Variable)
VARIABLE DISPLACEMENT
Basic Spring Shuttle NON- COMPENSATED
Pilot
Symbol Loaded Line Restriction
Controlled Spring Loaded Gas Charged Restriction
(Fixed)

Unidirectional Bidirectional

MAIN AUX.
Line Restriction
PILOT CONTROL 2-Section
RELEASED PRESSURE ROTATING SHAFTS Variable and Pressure
Compensated
Pump

Unidirectional Bidirectional
External Return Internal Return
Attachment Pump: Variable and
REMOTE SUPPLY PRESSURE Pressure Compensated

Internal Hydraulic Pneumatic


Simplified Complete Supply Pressure Energy Triangles

COMBINATION CONTROLS
LINES MEASUREMENT

Solenoid Solenoid Solenoid Solenoid and Servo Thermal Detent Crossing Joining
or Manual and Pilot Pilot or Manual Pressure Temperature Flow

MANUAL CONTROL FLUID STORAGE RESERVOIRS

Push-pull Lever Manual Shutoff General Manual Push Button Pedal Spring Vented Pressurized Return Above Fluid Level Return Below Fluid Level

HYDRAULIC SYMBOLS - ELECTRICAL ELECTRICAL SYMBOLS


G
M T

Pressure Temperature Level Flow


Transducer Transducer Generator Electric Pressure Pressure Switch Temperature Electrical
Switch Switch Switch Switch Circuit Breaker
(Fluid) (Gas / Air) Motor Switch (Adjustable) Switch Wire

BASIC ELECTRICAL COMPONENT SYMBOLS HARNESS AND WIRE SYMBOLS


Wire, Cable, or Harness Assembly Identification:
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it. Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).

Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
AG-C4 L-C12
111-7898 3E-5179
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Part Number: for 1
Connector Plug
2
Ground (Wired): This indicates that the component is connected to a grounded wire.
The grounded wire is fastened to the machine. Receptacle
Plug
Pin or Socket Number
Ground (Case): This indicates that the component does not have a wire connected to ground. Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
It is grounded by being fastened to the machine.
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
harness (C1, C2, C3, ...)
a normally open reed switch; it opens the contacts of a normally closed reed switch.
L-C12
3E-5179
Sender: A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure. 5A
T Its resistance changes to give an indication to the gauge of the temperature or pressure. Component
Fuse (5 Amps) 9X-1123 Part Number
Relay (Magnetic Switch): A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it. 325-AG135 PK-14
Harness identification code:
The electromagnet can open or close the switch part of the relay. Wire Gauge*
This example indicates wire group 325,
wire 135 in harness "AG". Wire Color
Solenoid: A solenoid is an electrical component that is activated by electricity. *Wire gauge is shown in AWG (American Wire Gauge)
It has a coil that makes an electromagnet when current flows through it. but could also be shown in metric denoted with mm
The electromagnet can open or close a valve or move a piece of metal that can do work. Deutsch connector: Typical representation
1
of a Deutsch connector. The plug contains all
Magnetic Latch Solenoid: An electrical component that is activated by electricity and held latched by a 2 sockets and the receptacle contains all pins.
permanent magnet. It has two coils (latch and unlatch) that make electromagnet Sure-Seal connector: Typical representation
when current flows through them. It also has an internal switch that places 1
of a Sure-Seal connector. The plug and receptacle
the latch coil circuit open at the time the coil latches. 2 contain both pins and sockets.
M0100459
November 2018

426F2 Backhoe Loader


Hydraulic System
DJ4172-UP
EJ2250-UP
EJ41500-UP

© 2018 Caterpillar. All Rights Reserved. CAT, CATERPILLAR, LET’S DO THE WORK, their respective logos, “Caterpillar Yellow,” the “Power Edge”
and Cat “Modern Hex” trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.
COMPONENT LOCATION
Schematic Machine
Description
Location Location
ACCUMULATOR GP - PILOT (CHARGED) D-3 1
ACCUMULATOR GP - RIDE CONTROL (CHARGED) (OPTIONAL) C-8 2
CYLINDER GP - BOOM F-6 3
CYLINDER GP - BUCKET F-3 4
CYLINDER GP - EXTENDABLE STICK F-2 5
CYLINDER GP - LIFT C-6 6
CYLINDER GP - MULTI PURPOSE BUCKET (OPTIONAL) C-5 7
CYLINDER GP - STABILIZER (LH) F-4 8
CYLINDER GP - STABILIZER (RH) F-4 9
CYLINDER GP - STEERING D-7 10
CYLINDER GP - STICK F-2 11
CYLINDER GP - SWING F-5 12
CYLINDER GP - TILT C-6 13
FILTER GP - HYDRAULIC A-7 14
MANIFOLD GP - RIDE CONTROL (OPTIONAL) B-8 15
PUMP GP - IMPLEMENT B-3 16
PUMP GP - METERING (HMU) D-8 17
RADIATOR AND HYD OIL COOLER GP A-6 18
SWITCH AS - PRESSURE (RIDE CONTROL) (OPTIONAL) B-8 19
TANK AND MTG GP - HYDRAULIC A-5 20
TANK GP - HYDRAULIC A-5 21
VALVE GP - BACKHOE E-6 22
VALVE GP - BOOSTED BRAKE C-2 23
VALVE GP - CONTROL (TILT) C-7 24
VALVE GP - LOAD CONTROL (STABILIZER) (OPTIONAL) F-4 25
VALVE GP - MANIFOLD AND REDUCING (SERVICE BRAKE CONTROL) C-3 26
VALVE GP - PRESSURE CONTROL (RELIEF) (SWING) (OPTIONAL) F-5 27
TAP LOCATION

Tap Schematic
Description
Number Location
AA PUMP DISCHARGE PRESSURE PORT B-3
BB LOAD SENSE PRESSURE PORT B-3
CC PILOT PRESSURE PORT C-3
SOS OIL SAMPLING PORT A-7
8 7 6 5 4 3 2 1

BOOM SWING STAB STAB BUCKET STICK E-STICK SLIDE FRAME CLAMP
(8) CYLINDER GP (9) CYLINDER GP
(3) CYLINDER GP (12) CYLINDER GP STABILIZER (LH) (4) CYLINDER GP (11) CYLINDER GP (5) CYLINDER GP
SWING STABILIZER (RH)
F BOOM 478-1348 478-1348
BUCKET STICK E-STICK (OPT) F
478-1347 478-1349 STD: 478-1345 STD: 478-1346 510-7948
E-STICK: 546-6620 E-STICK: 546-6613

(27) VALVE GP - PRESSURE


CONTROL
(RELIEF) (SWING) (OPT)
(25) VALVE GP - LOAD CONTROL
320-7812
(STABILIZER) (OPT)
308-3437

(22) VALVE GP A B
CONTROL (BACKHOE) 207 bar
A B

6 BANK: 456-1853
7 BANK: 479-0623
B1 A1 B2 A2 B3 A3 B4 A4 B5 A5 B6 A6 B7 A7 C

LS b
b b b b b

E E

(17) PUMP GP
METERING (HMU)
4WD: 449-1647
2WD: 532-4993
a a a a a a

(9) CYLINDER GP
STEERING T3
L R 4WD: 214-5097 T
2WD: 532-9806
B T B A T T T T T T B A T
T A T B A B A

STEERING
D D

(23) VALVE GP
BOOSTED BRAKE
(1) ACCUMULATOR GP 220-8226
PILOT (CHARGED)
149-0686
(6) CYLINDER GP (13) CYLINDER GP (7) CYLINDER GP
LIFT TILT MP BUCKET (OPT)
478-1350 478-1351 551-5182
LEFT
LIFT TILT AUXILIARY BRAKE TO REAR AXLE
PEDAL
(OPTIONAL ONLY) LEFT WHEEL BRAKE

P T LS
RIGHT TO REAR AXLE
BRAKE RIGHT WHEEL BRAKE
PEDAL

C C
(24) VALVE GP
CONTROL (TILT)
2 BANK: 456-1851 M LS D B1 A1 B2 A2 B3 A3
3 BANK: 456-1852 CC
(2) ACCUMULATOR GP
(Dimensions: 39 inches x 28 inches)

DLS (26) VALVE GP


RIDE CONTROL (CHARGED) (OPT) MANIFOLD AND REDUCING
345-3672 b (SERVICE BRAKE CONTROL)
373-6966
b b
M0100459

(19) SWITCH AS (15) MANIFOLD GP P


PRESSURE RIDE CONTROL (OPT)
(RIDE CONTROL) (OPT) 518-5019 (16) PUMP GP
IMPLEMENT
304-5696 307-3063
PS ACC

a a a LINE PATTERNS
LS
BB Pressure Line
30 Page,

T Pilot / Load Sensing Pressure

B T T
T T
X1 Drain / Return Lines B
B B A T
R H B Air Line
T
Component Group

CALLOUTS
LIFT TILT YY Taps (Pressure, Sampling, Sensor - by letter)
AA DL DL D Connectors (By letter)

Callout Number Component


(Machine Location from (52) VALVE GP - CONTROL Name
Component LocationsTable)
138-1234 Part Number

HYDRAULIC CIRCUIT COLOR DESCRIPTIONS


MB
PILOT PUMP OUTPUT
MAIN PUMP OUTPUT
SLIDE FRAME CLAMP CIRCUIT
BUCKET CYLINDER CIRCUIT
LOAD SENSE CIRCUIT
STEERING CIRCUIT
(14) FILTER GP STICK CYLINDER CIRCUIT
HYDRAULIC SUPPLY LINE
E-STICK CIRCUIT
361-6768 BOOM CYLINDER CIRCUIT
AUX CIRCUIT
SWING CYLINDER CIRCUIT
DRAIN / RETURN LINE
A (18) RADIATOR AND STABILIZER CYLINDER CIRCUIT A
LIFT CYLINDER CIRCUIT
HYD OIL COOLER GP TILT CYLINDER CIRCUIT
487-3313 BOOSTED BRAKE OIL CIRCUIT
(20) TANK AND MTG GP
HYDRAULIC
473-9925 MS L2
SOS (21) TANK GP
HYDRAULIC
S L1
THIS SCHEMATIC IS FOR THE 426F2 BACKHOE LOADER HYDRAULIC SYSTEM
HAMMER RETURN 510-7168
MEDIA NUMBER: M0100459
Do not operate or work on this product unless you have
read and understood the instruction and warnings in the SCHEMATIC PART NUMBER: 485-7320, CHANGE: 04, VERSION: D
relevant Operation and Maintenance Manuals and
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
relevant service literature. Failure to follow the instruc-
tions or heed the warnings could result in injury or
in neutral and with parking brake set.
death. Proper care is your responsibility. Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.

8 7 6 5 4 3 2 1
MACHINE LEFT REAR VIEW
VIEW ALL CALLOUTS

4
5

11
BACKHOE AR
25 EXTENDABLE STICK VIEW

19
15

25

27

2 VIEW OF AREA “A”


(ROTATED FOR CLARITY)
MACHINE RIGHT SIDE VIEW
VIEW ALL CALLOUTS

BACKHOE AR
STANDARD STICK VIEW

11

6
13

12

10 7
9
UNDER CAB VIEW
VIEW ALL CALLOUTS
20 21 18

17

23
16

14
1

26 BB

CC
AA

24

SOS

22