You are on page 1of 13

Vickers®

Directional Controls

Wet Armature Solenoid Operated


Directional Control Valves
DG4S*-01, 60 design

Revised 3/92 GB–C–2129


Table of Contents

Basic Characteristicts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Functional Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Model Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Maximum Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Solenoids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Pressure Drop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Maximum Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
DG4S2–012A–*–60
DG4S4–01*A–*–60
DG4S4–01*B–*–60
DG4S4–01*F–*–60
DG4S4–01*C–*–60
DG4S4–01*N–*–60
DG4S2–01*N–*–60
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
SDG4S4–01*A–*–60
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
PBDG4S*–01**–*–60
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
PA*DG4S*–01**–*–60
PA5DG4S*–01**–*–60
SPA5DG4S*–01**–*–60
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
W, WT & WL Models
Installation Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
U Models
Mounting Subplates and Bolt Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2
Basic characteristics General description
Max. pressure Up to 250 bar (3600 psi) DG4S* models are direct solenoid Valves are available with AC or DC
dependent on fluid operated, 2-way or 4-way directional wet-armature solenoid(s). Electrical
control valves. Their primary function in a connections to the valve are made in an
Max. flow rates Up to 95 l/min
hydraulic circuit is to direct fluid flow to a electrical wiring housing or by various
(25 USgpm) dependent
work cylinder or to control the direction plug-in devices. A ground terminal is
on spool
of rotation of a hydraulic motor. provided.
Mounting ISO 4401-05/ Port connections are made by mounting
pattern CETOP 5/NFPA-D05 the valve on a manifold or subplate
containing the interface.

Functional symbols
Graphic
Standard N" Models
Symbol A" Models B" Models C" Models F" Models
Spool Detented
Center Spring Offset Spring Centered Spring Centered Spring Offset
Types (No Spring)
Condition
b AB b AB b AB a b AB b AB a

0
PT PT PT PT PT
b AB b AB a b AB
1
PT PT PT

b AB b AB a

11
PT PT

b AB b AB b AB a b AB b AB a

2
PT PT PT PT PT

b AB b AB a b AB

3
PT PT PT
b AB b AB a
31
PT PT
b AB b AB b AB a b AB b AB a
6
PT PT PT PT PT
b AB a AB b AB a
b AB b AB b

7
PT PT PT PT PT
AB b b AB a

8
PT PT
b AB b AB a b AB a

33
PT PT
b AB b AB a
2
(2-way)
PT PT

Standard (right hand) build shown. Note


A" solenoid omitted. On all models, when solenoid a" is
energized, flow is always P" to A". When
solenoid b" is energized, flow is always P"
to "B". This is in accordance with the
ANSI-B93.9 standard. Solenoid
designations a" and b" are identified on
the diagram plate on the side of the valve.
3
Model Code
(F3) - * *** DG4S * ** - 01 ** * - (U) - ** - 60 - (LH)

1 2 3 4 5 6 7 8 9 10 11

1 Seals 5 Electrical accessories 9 Coil identification letter(s)


Blank - Standard seals L - Solenoid indicator lights See Solenoids" section.
F3 - Special seals W - Wiring housing
LW - Wiring housing with indicator lights 10 Design number
2 Monitor switch
WT - Wiring housing with terminal strip
S - Monitor switch (Available as Omit if not required. Subject to change.
A" spring offset model only) Installation dimensions remain as shown
Omit if not required. 6 Spool types for designs 60 through 69.
See Functional symbols" section.
3 Electrical plug options 11 Left hand assembly
PA - Insta-plug (male only) 7 Spool/spring arrangement Omit for right hand assembly with
PB - Insta-plug male & A - Spring offset, P to A solenoid a" removed.
female receptacles B - Spring centered, solenoid a"
PA3 - 3 pin connector removed
PA5 - 5 pin connector C - Spring centered, three position
Omit if not required. F - Spring offset, P to A; shift to center For DIN 46350 electrical plug(s)
4 Flow direction N - No spring, detented See U models" in Installation
2 - 2 way 8 Wet armature solenoid(s) dimensions" section.
4 - 4 way (Non-serviceable core tubes) For mounting subplates and bolt kits
Blank - Flying lead coil(s) See Installation dimensions" and
U - DIN 43650 coil(s) without Ordering procedure" sections.
electrical plug

Maximum pressure Solenoids


Ports P, A & B 250 bar (3600 psi)* Solenoid Solenoid Inrush Holding Holding
Port T 70 bar (1000 psi) Identification Voltage Rating Amps Amps Watts
Letter (rms) (rms)
*70 bar (1000 psi) with high water base
fluids (95% maximum water content) B 120 VAC 60 Hz 3.80 0.69 35
110 VAC 50 Hz 4.10 0.85 33
D 240 VAC 60 Hz 2.10 0.34 36
220 VAC 50 Hz 2.30 0.45 34
ED 240 VAC 50 Hz 1.85 0.27 28
Solenoid energizing A
C
110 VAC 50 Hz
220 VAC 50 Hz
3.80
2.00
0.63
0.30
29
28
Spring centered and spring offset valves G 12 VDC 3.67 44
will be spring positioned unless the H 24 VDC 1.83 44
solenoid is energized continuously. J 48 VDC 0.92 44
No-spring detented valves may be X 250 VDC 0.17 44
energized momentarily, approximately DP 125 VDC 0.35 44
.15 second; when the solenoid is
de-energized the spool will remain in
the last position attained, provided there
Response time
is no shock, vibration or unusual The following response times were Response up to full system pressure is
pressure transients. measured from the point of energization/ dependent on the system's compressed
de-energization to the point of first volume and can vary with each
NOTE indication of inlet pressure change. application.
Any sliding spool valve, if held shifted
under pressure for long periods, may Model Valve type AC Solenoid DC Solenoid
stick and not spring return, due to Shift Return Shift Return
silting. Therefore, it is recommended B/C Spring centered 20 ms 40 ms 50 ms 80 ms
that the valve be cycled periodically to A Spring offset 18 ms 25 ms 50 ms 60 ms
prevent this from occurring. F Spring offset 18 ms 18 ms 30 ms 80 ms
N Detented 25 ms 60 ms

4
Drain NOTE
Surges of oil in a common line serving
On 2-way valves, T" is the drain and
these and other valves can be of
must be connected to the tank through a
sufficient magnitude to cause inadvertent
surge-free line, so there will be no back
shifting of these valves. This is
pressure at this port.
particularly critical in the no-spring
detented type valves. Separate tank
lines, or a vented manifold with a
continuous downward path to tank, are
necessary.

Pressure drops
The pressure drop curves give For any other viscosity, the pressure drop
approximate pressure drop (DP) when (DP) will change as follows:
passing 21 cSt (100 SUS) fluid (having
.865 specific gravity) through the Viscosity cSt 14 32 43 54 65 76 86
indicated flow path. (SUS) (75) (150) (200) (250) (300) (350) (400)
% of DP 93 111 119 126 132 137 141
Pressure drop curve reference chart (Approx)
Curve numbers
Spool type For any other specific gravity (G1),
P-A B-T P-B A-T P-T
the pressure drop (DP1) will be
0C/N 2 1 3 1 2
approximately: DP1 = DP (G1/G)
1C 1 2 3 1 -
11C 2 1 2 2 -
2C/N 2 2 3 2 -
3C 3 2 3 1 - FLOW - USgpm
31C 3 1 3 2 -
0 2 6 10 14 18 22 26
6C/N 4 1 4 1 -
7C/N 1 2 1 2 - 20
280
8C 3 4 3 4 6 7
18 260
33C/N 3 2 3 2 - 6
2 way 240
16 5
2A 2 - 7 -
220
PRESSURE DROP - psid

2A-LH 7 - 2 -
PRESSURE DROP - bar

14 200
2N 2 - 2 - 4
12 180
3 160
Pressure drop curve reference chart 10
Curve numbers 140
Spool type 2
P-A B-T P-B A-T 8 120
0A/F 1 2 2 2 100
0A/F-LH 2 2 2 2 6 1
80
1F 1 2 - -
4 60
1F-LH - - 2 2
2A/F 2 2 5 4 40
2
2A/F-LH 4 4 3 2 20
3F 2 1 - - 0 0
3F-LH - - 2 2
0 20 40 60 80 100
6A/F 2 1 6 3
6A/F-LH 4 2 3 2 FLOW - l/min
7A/F 1 2 2 4
7A/F-LH 2 3 2 2

5
Maximum flow data
Maximum recommended flow data is for
AC & DC solenoid valves
AC or DC solenoids at 90% nominal FLOW - USgpm
voltage in a 4-way circuit with cylinder 0 2 6 10 14 18 22 26
ports either looped or blocked and 300
containing 2,5 liter (.66 USgpm) 4000
compressed volume. Reduced
performance may result when certain 250
spools are used in 3-way circuits.

PRESSURE - psi
PRESSURE - bar
3000
200
6 4 2
Maximum flow chart reference 150
3 2000
Model Spool type Curve number 1
5
AC DC 100
A 0 1 1
2 2 2 1000
6 3 3 50
7 2 2
B/C 0 1 1
0 0
1 6 6
11 6 6 0 20 40 60 80 100
2 1 1 FLOW - l/min
3 2 2
31 2 2
6 2 2
AC & DC solenoid valves
7 1 1 FLOW - USgpm
8 4 8 0 2 6 10 14 18 22 26
33 1 1 300
F 0 1 1
4000
1 5 5
2 1 1 250
PRESSURE - bar

3 1 7

PRESSURE - psi
6 1 7 3000
7 1 1 200
N 0 1 1
2 1 1 150 7 2000
6 1 1
8
7 2 2
33 1 1 100
2-way
A 1000
2 5 5
N 50
2 3 3

0 0
0 20 40 60 80 100
FLOW - l/min

Seals/fluids Application
Special F3 seals are required for use
recommendations
with phosphate ester type fluids or their Filtration...............ISO 4406 Code 18/15
blends. Standard seals are suitable for
use with water glycol, water-in-oil Operating temp......20_ to 50_C (70_ to 120_F)
emulsion fluids, HWBF (95% maximum Fluid viscosity.......16 - 51 cSt (75-250 SUS)
water content), and petroleum oil.

6
Installation dimensions in mm (inches)

3rd angle
Applicable models projection

DG4S2-012A-*-60 Spring offset


DG4S4-01*A-*-60 Spring offset
DG4S4-01*B-*-60 Spring centered
DG4S4-01*F-*-60 Spring offset
Right hand model shown D 212,4 DC " models
(8.36) AC" models 173,8
159,2 DC " models (6.84)
(6.27) AC" models 120,6
(4.75)

97,7
(3.85) Sol. `b'

69,5
89,4 (2.73)
36,1
(3.52)
(1.42)

34,9 L" models 45,3


(1.38) (1.78) 90,5
69,8 Manual actuator (3.56)
(2.75)
71,4
(2.81)
D 8B" right hand build model has
solenoid `b' on opposite end
(B" port end).

Applicable models
DG4S4-01*C-*-60 Spring centered D
DG4S4-01*N-*-60 No spring detented
DG4S2-01*N-*-60 No spring detented
318,4 DC " models
(12.54) AC" models 241,2
159,2 DC " models (9.50)
(6.27) 120,6 AC" models
(4.75)

97,7
(3.85)
89,4 Sol `b' Sol. `a'
(3.52)
69,3
(2.73)

L" models 45,3


(1.78) 90,5
Manual actuator (3.56)

D 8C" models have solenoid


designations reversed.

7
Applicable models
SDG4S4-01*A-*-60 Spring offset
Right hand model shown

Integral monitor switch permits electrical Volts AC amp DC amp


interlocking of various hydraulically 28 20 10
controlled motions without resorting to 125 20 0.5
external mechanical contrivances. The 250 20 0.2
switch monitors the valve spool position 480 20
and may be wired into the control circuit. 600 5

Monitor switch data: Monitor switch housing does not provide


Plunger type for manual operation.
- panel mounting
- single pole
- double throw contact arrangement
- A" normally closed
- B" normally open.

253,1 AC" models D


(9.96)
120,6 AC" models D 132,5
(4.75) (5.22)
Hole for
switch leads
97,7
(3.85)

Sol. `b'
89,4
(3.52)
69,5
(2.73)

45,3
L" models Manual 190± 0.38
(1.78) 90,5
actuator (.075 ± .015)
(3.56)

53,9 Torque housing screws


(2.12) 1.4 - 1.8 N.m
27,0 9,5
(12-18 lbf.in.)
(1.06) (.38)

46,0
(1.81)

23,0 1,6
(.91) 10,3 (.06)
10,3
(.41) (.41) 16,7
23,8 23,8 (.66)
(.94) (.94)

D For DC model length, see A models at


top of facing page.

8
4 leads approx. 178 mm (7.00") long. White leads are connected to solenoid 'a'
and black leads are connected to solenoid 'b'. (See diagram plate) For type 8"
spool and left hand models, conduit connection location is reversed.
Applicable models
PBDG4S*-01 *-*-60 Clearance required to remove
female receptacle
20,2
Stripped and (.80) 63,5
twisted wire (2.50)

12,7
(.50)
WARNING
Warning
plate G

Center line of 160,3


.5000 NPTF (6.31)
dryseal thread
126,2 154,9
(4.97) (6.10)
Sol. `b'
146,8
(5.77)

PB-L" models 34,9


Manual (1.38)
PB" models 69,8
actuator
(2.75)
71,4
Electrical conduit connection is over
G Warning (2.81)
solenoid on single solenoid models,
and over b" solenoid on dual Electrical power must be disconnected
solenoid models. See diagram plate before removing or replacing this
for b" solenoid location. receptacle.

The insta-plug" consists of the 88,9


following features: (3.50)
44,4
1. Section A", a four-pronged self Connections to the electric power are (1.75)
aligning electrical plug secured in a made through the end of the receptacle
housing that is mounted on top center housing and can be prewired by the
of the valve body where the solenoid customer. End location of electrical conduit
leads terminate; or: port permits space-saving side-by-side
2. A B" complete insta-plug assembly valve mounting.
that includes the A" housing on top of
which rests a similar housing Wire leads approximately 177.8 mm
containing the mating receptacle. The (7.00") long are provided when no lights
two housings are keyed to assure are specified. Models with lights have Electrical receptacle
proper hook-up. terminals inside the receptacle housing. 8-32 Tapped hole for customer
to connect ground
The top housing is removed from the A nameplate and solenoid indicator lights
lower (A") housing to break the electrical are part of the receptacle when specified. Solenoid indicator lights
connections to the valve solenoids, or
pressed onto the A" housing to
After initial installation, electrical and
complete the circuit. The assembly is
hydraulic connections need not be
held together by two slotted thumb
disturbed when valve with insta-plug
screws.
is removed.
Solenoids A" and B" are identified on
the plug-in and receptacle housings;
they correspond with solenoid
identification plate.

9
Applicable models
PA*DG4S*W/LW-01*A-*-60
PA*DG4S*W/LW-01*B-*-60
PA*DG4S*W/LW-01*F-*-60
PA5DG4S4W/LW-01*C-*-60
PA5DG4S4W/LW-01*N-*-60
SPA5DG4S4W/LW-01*A-*-60

103,5
65,4
14,2 (4.08)
(2.58)
32,7 (.56)
(1.29)

Warning
.8750-16 WARNING
Electrical power tag G
UN-2A Thd. must be disconnected
before removing or
replacing plug

Wiring decal
25,4
Hex 137,4
(1.00)
(5.41)

129,0
(5.08)

104,3
(4.11)

W" models
LW" models [

2 lead ( to monitor switch,


common, black lead)
1 lead to solenoid
1 lead to solenoid B" 5 lead to
1 green lead (ground) 1 lead to solenoid solenoid
5 lead to
3 lead to solenoid 5 lead to solenoid
solenoid B" 4 lead to monitor
4 lead capped 4 lead to switch, N.O.,
solenoid A" plain lead

3 green lead (ground) 3 green lead (ground) 3 green lead


2 lead to solenoid
2 lead capped 2 lead to solenoid A" (ground)

PA3DG4S*W/LW-01**-*-60 PA5DG4S*W/LW-01**-*-60 PA5DG4S4W/LW-01**-*-60 SPA5DG4S4W/LW-01**-*-60

A models A models C models A models only


B models B models N models
F models F models

Electrical connection is over solenoid on [ Receptacle will be prewired directly to the D For models with monitor switch, wires
single solenoid models, and over b" terminals on the solenoid indicator light to be supplied and connected by
solenoid on dual solenoid models. See package. (For exception see note D"). customer.
diagram plate for b" solenoid location.
Electrical rating 600 volts, 3 pole, 10 Receptacle will be prewired to the
amps and 5 pole, 8 amps. The female solenoid eyelets. The connection will be
portable plug to be furnished by made via No. 6 screws and nuts
customer. insulated with black electrical tape. (For
G Warning exception see note D").
Electrical power must be
disconnected before removing
or replacing this receptacle.

10
W, WT & LW models

D For models with monitor switch, The housing can be rotated 180_ if the
wires to be supplied and connected by connection is required on the opposite
customer. end. This connection will readily accept
common electrical quick disconnect
assemblies on the market. The wiring
housing is available with all options.
.5000 NPTF
Dryseal thread
65,4 LW" models D
(2.58)
W/WT" models
32,7
(1.29)

129,0
(5.08)

104,3 137,4
(4.11) (5.41)

DG4S*-W-01 DG4S*-LW-01
A drilled hole is provided for a customer's Lights are on" when there is voltage
no. 8 self tapping screw which will permit across the solenoids.
a ground wire to be secured to the pilot
valve body. (Not shown on this drawing).
The wiring housing has a cast hole 3
which also permits securing a ground
wire with customer's no. 8 self tapping
screw. Units can be series grounded if
desired. The DG4S*-01 pilot valve
bodies have
a cast ground symbol" adjacent to the
drilled hole.

11
U models

This interface is used for connecting


electrical receptacles conforming to
German DIN std 43650.

DC " models dual solenoid 318,4


(12.54)

AC" models dual solenoid 241,2


(9.50)
212,4 DC " models single solenoid
(8.36)
AC" models single solenoid 173,8
(6.84)

U" DIN 43650


AC" type

120,6 78,5
(4.75) AC" models (3.09)
159,2 89,4
(6.27) (3.52)
DC " models

Plug connector
(Order separately)
(ISO4400/DIN 43650)
51 22,5 D
Cable diameter range Ø6-10mm (0.24-0.40) (2.01) (.88)
Wire section range Ø,5-1,5mm 2 (0.0008-0.0023in2)
Teminals Screw type
27
Type of protection IEC144 class IP65, when plugs are fitted correctly to (1.06)
the valves with the interface seals (suppplied with plugs)
in place.
Seal
M3 1,5
thread (.06)
30,5 5,5
(1.20) (.22)
Connector can be positioned at 90_ Voltage Gray - Black -
Receptacle (AC or DC) 26,5
intervals on valve by re-assembling A" sol. B" sol.
(1.04)
contact holder into appropriate Without
710776 710775
position inside connector housing. lights
27,5
12-24 977467 977466 (1.08)
Connectors with and without indicator With
100-125 977469 977468
lights are available (Order separately): lights
200-240 977471 977470

12
Mounting Subplates and Bolt Kits

P" pressure conn.


50,80 (2.00) 10,31 (.406) D. thru 20.57 (.81) D.
39,62 (1.56) Spotface 4-holes for mounting 28,45 (1.12)
10,41 (.41)
11,9 R 10,41 (.41) 3,59 (.22)
(.47) 68,33 (2.69) 5,59
23,88 (.94) *B" cyl (.22)
15,75 (.62)
6,35 (.25) conn.
14,99 (.59)
114,30
91,95 (4.50)
26,16
45,97 (3.62)
(1.03) 43,69
P
(1.81) B T
A
47,75 (1.72)
* T" 47,75 23,11 (1.88)
tank (1.88) (.91)
conn.
11,18 R
(.44) 18,29
12,70 23,11 101,60
(.50) 53,98 (.91) (.72) (4.00)
23,88 (.94) 20,57
(2.12) (.81)
* A" Cyl. con. 79,38
(3.12) A
.750-16 UNF-2B Thd. for
33,02 (1.30) .2500-20 UNC-2B thd .500 O.D. tubing. 4 holes
4-holes for mounting (system connections)
*Ports on model DGSME-01-20-T8 only .438 dia system port 4 holes

Model Dimension A" When subplate is not used, a machined


pad (as indicated by subplate shaded
DGSM-01-20-T8 31,75 (1.25)
area) must be provided for mounting;
DGSME-01-20-T8 38,10 (1.50)
pad must be flat within 0.0127 mm
(.0005 inch) and smooth within 1.6 mm
(63 microinch).

Mounting position Ordering procedure


The mounting position is unrestricted for Valves, subplates and bolt kits must be Maximum recommended mounting bolt
all valves, except detented (N model) ordered separately. torque is 12,6 N.m (112 lbf. in.).
valves which must be installed with their Example: Mounting bolts, when provided by
longitudinal axis horizontal for reliable One (1) DG4S4-012C-U-B-60 valve customer, should be SAE grade 7 or
operation. One (1) 710775 solenoid plug connector, better.
black, marked B
One (1) 710776 solenoid plug connector,
gray, marked A
One (1) DGSM-01-20 T8 subplate
One (1) BKDG01-633 bolt kit