You are on page 1of 19

From the dawn of Excellence

emanates the high noon of Performance.


Gelco Electronics is a full service electronic company that manufactures superior quality electronic control &
measuring equipment alongwith power saving devices. Established in 1984, the company is located in the industrial
belt of Ahmedabad, which is one of the fastest developing metropolitan cities of India.

Our state of the art manufacturing facility with its prolific R&D centre in conjunction with our strict adherence
to quality control and safety norms has ensured an impressive growth record in these past three decades. More
importantly, it has gained a reputation of Excel- lence & Dependability from its clients.

After achieving wide success in the Indian market, Gelco Electronics is now spreading its wings internationally.
To attain the same level of success globally, Gelco Electronics has conducted extensive research in each
market to understand their electrical equipment’s needs and subsequently, developed specific products for
them that are longlasting, efficient and safe.

Range of Produc ts
• Single Phase Motor Starters & Control Panel
• Three Phase DOL Motor Starters & Control Panel
• Three Phase Star Delta Motor Starters & Control Panel
• Duty Stand by Panel for Duplex Pumps
• Panel Accessories

A pp l i c at i o n s
• Home
• Agriculture
• Industries
SINGLE PHASE MOTOR STARTER
Input Supply voltage : 230V, AC ±20% | Output supply voltage : 230V, AC +20%

INDE X (1.1) | GSS-MCB


Topic Page
S a l i e n t F e at u r e s :
Single Phase Motor Starter 1-2 • Easy to operate
Single Phase Electronic Control Panel 3 • Overload protection through MCB
Three Phase Dol Motor Starter 4-5 • Economical Solution
Three Phase Dol Motor Starter - Metal Body 6 • Enclosure made from Engineering grade Plastic (ABS)
Three Phase Star Delta Motor Starter 7
Three Phase Dol Electronic Control Panel 8 A pp l i c at i o n :
Three Phase Star Delta Electronic Control Panel 9 Only for Oil Filled Pump set

Duty Stand By Panel For Duplex Pumps Operation 10


Va r i a n t s :
Stabilizer 11
Motor H.P. Run Capacitor MCB
Auto Switch 12
0.75 HP 0 + 25 MFD 10 Amp.
Motor Starter 13
1.0 HP 0 + 36 MFD 10 Amp.
A.C. Switch 14
1.5 HP 0 + 50 MFD 16 Amp.
Phase Failure Relay 15 2.0 HP 0 + 72 MFD 25 Amp.
Phase Failure Relay 16
Motor Protection Relay 17
Pump Protection Relay 18
Analog Timer 19-20
Digital Timer 21 (1.2) | GSS-RE
Digital Time Switch 22
S a l i e n t F e at u r e s :
Earth Leakage Relay 23-24
• Electronic Start/Stop push buttons.
Earth Leakage Circuit Breaker 25
• Electronic Overload protection
Panel Meters 26
• High voltage protection above 270 Vac.
Automatic Light Controller 27
Spp With Water Level Guard 28 • Low voltage protection below 150 Vac.

Water Level Controller 29-30 • Engineering grade plastic enclosure (ABS).


• Facility to connect Gelco Water Level Controller Adaptor

( LLC-001D/LLC-001)
NOTE:
• A wide range of products which can be offered on request. A pp l i c at i o n :
• We can supply starter / panel / A.T.S. panel / 60 Hz starter / panel as per customer’s specifications. Only for Oil Filled Pump set
• A wide range of lighting products which can be offered on request.
• We can supply submersible flat & round, PVC & rubber, 3 core and 4 core cable. Va r i a n t s :
• We can supply submersible pumpsets, monoblock pumpsets, industrial pumpset, electric induction motors & Motor H.P. Run Capacitor MCB
UPVC column pipes etc. 0.75 HP 0 + 25 MFD 4 - 10 Amp.
• Due to continues R & D; specifications, construction of materials, design, out look, colour 1.0 HP 0 + 36 MFD 4 - 10 Amp.
& finishing etc. can be changed without intimation. 1.5 HP 0 + 50 MFD 10 - 16 Amp.
2.0 HP 0 + 72 MFD 10 - 16 Amp.

1
SINGLE PHASE MOTOR STARTER SINGLE PHASE ELECTRONIC
Input Supply voltage : 230V, AC ±20% | Output supply voltage : 230V, AC +20% CONTROL PANEL Input Supply voltage : 230V, AC ±20%
Output supply voltage : 230V, AC ±20%

(1.3) | DCP - RE (2.1) | MCB WS


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Electronic Start/Stop Push button. • In built digital Volt and Amp. Meter ( GELCO ACCURA)
• Easy to operate
• In built digital volt and amp meter
• Powder coated sheet metal enclosure.
• Latest Micro Controller Based Technology for better accuracy
• Presice protection against Overload( Over Current) A pp l i c at i o n :
• Presice protection aganist high voltage • Submersible/Monoblock Pump set.

• Presice protection against low voltage


Va r i a n t s :
• Dry run protection ( Optional)
MCB Start Capacitor Run Capacitor
• Digital indication of fault condition.
10 100/120 MFD 36 MFD
• Engineering grade plastic enclosure( ABS) 20 150/200 MFD 36 + 36 MFD
• Facility to connect GELCO Water Level Controller Adaptor 25 200/250 MFD 36 + 36 MFD
( LLC-001D) 25 200/250 MFD 50 + 50 MFD
• Parameters can be programmable

A pp l i c at i o n :
Only for Oil filled pumpset
(2.2) | DCP - 7201
Va r i a n t s :
S a l i e n t F e at u r e s :
Motor H.P. Run Capacitor • Fully automatic Electronic Start/Stop facility
1.0 HP 36 MFD • Digital Micro Controller based technology
1.5 HP 50 MFD • Higher accuracy
2.0 HP 72 MFD • Digital indication of fault condition.
• Precise overload protection( Over Current)
• Precise Overvoltage protection
• Precise Under voltage protection
• Dry run Protection.
• Parameters can be programmable
• In built Auto ON/OFF timer ( 1-240 Minutes)
• Powder Coated sheet metal enclosure.

A pp l i c at i o n :
Submersible/Monoblock Pumpset for water in residence,
commercial, farming, gardening.

Va r i a n t s :
Motor H.P. Start Capacitor Run Capacitor
1.0 HP 100/120 MFD 36 MFD
1.5 HP 150/200 MFD 36 + 36 MFD
2.0 HP 200/250 MFD 50 + 50 MFD

2 3
THREE PHASE DOL MOTOR STARTER Input/Output Voltage :415 V ± 20%VAC

(3.1) | GTW (3.3) | GTA


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Current sensing unit • Current Sensing Unit
• Inverse current characteristics • Additional facility to make Motor/Pump ON
• Electronic start/stop push button facility automatically after power supply resumption.
• Electronic overload protection. • One minute Time Delay before start
• Over voltage protection • Can be used up to 7.5Hp DOL moter/pumps
• Under voltage protection
A pp l i c at i o n :
• Dry run protection(Optional)
• D.O.L. Submersible Pump set for water in residence,
• Phase failure protection.
commercial, farming, gardening.
• Reverse phasing protection
• Induction motor in industries
• Engineering grade plastic enclosure(ABS)
• Can be used up to 7.5Hp DOL moter/pumps Va r i a n t s :
• Other Models are also available on request Type Current Range
A pp l i c at i o n : GTA-304 2 - 5 Amp.
• D.O.L. Submersible Pump set for water in residence, GTA-305 4 - 10 Amp.
commercial, farming, gardening. GTA-306 8 - 20 Amp.
• Induction motor in industries

Va r i a n t s :
Type Current Range (3.4) | DCP - 304
GTW-304 2 - 5 Amp.
S a l i e n t F e at u r e s :
GTW-305 4 - 10 Amp. • Used latest Micro controller based technolgy
GTW-306 8 - 20 Amp. • Electronic Start/Stop push button
• Inbuilt digital volt & amp Meter
• Digital display of fault condition
(3.2) | GTV • Electronic overload protection
S a l i e n t F e at u r e s : • Over voltage protection
• All facilities available as per GTW • Under voltage protection
• Current and voltage sensing unit • Dry Run protection
• Facility to connect GELCO Water Level Controller • Parameters can be programmed
(Model LLC-001/LLC-001D) • Phase failure protection
• Can be used up to 7.5Hp DOL moter/pumps • Reverse phasing protection
• Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D)
A pp l i c at i o n :
• Engineering grade plastic enclosure(ABS)
• D.O.L. Submersible Pump set for water in residence,
• Can be used up to 7.5Hp DOL moter/pumps
commercial, farming, gardening.
• Induction motor in industries A pp l i c at i o n :
• Three phase DOL Submersible/Monoblock Pump set
Va r i a n t s :
for water in residence, commercial, farming, gardening
Type Current Range
GTV-304 2 - 5 Amp. Va r i a n t s :
GTV-305 4 - 10 Amp. Current Range
GTV-306 8 - 20 Amp. 2 - 5 Amp.

4 5
THREE PHASE DOL MOTOR STARTER - METAL BODY THREE PHASE STAR DELTA MOTOR STARTER
Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC

(4.1) | GEW-1(DOL) (5.1) | GLO-FASD / SA-Metal Body


S a l i e n t F e at u r e s : Va r i a n t s :
• Easy to operate
• Powder Coated sheet metal enclosure. Type Motor H.P. Overload range
• Thermal Overload protection GLO-1 3 HP 6 - 10 A
GLO-1 4 HP 6 - 10 A
A pp l i c at i o n : GLO-1 5 HP 6 - 10 A
• D.O.L Motors for water in residence, commercial, farming, gardening. GLO-1 6 HP 6 - 10 A
GLO-1 7.5 HP 6 - 10 A
Va r i a n t s :
GLO-1 10 HP 6 - 10 A
Motor H.P. Overload range GLO-1 12 HP 10 - 16 A
5.0 HP 6 – 10 A GLO-1.5 15 HP 13 - 21 A
7.5 H.P 9 – 14 A GLO-2 20 HP 20 - 32 A
10 H.P 13 – 21 A GLO-2 25 HP 20 - 32 A
GLO-3 30 HP 28 - 42 A
GLO-3 40 HP 28 - 32 A

(4.2) | GLO-1 (DOL)


Va r i a n t s :
Motor H.P. Overload range
3.0 HP 6 – 10 A
5 H.P 6 – 10 A
7.5 H.P 10 - 16 A

(4.3) | GLO-1.5 / 2 / 3 (DOL)


Va r i a n t s :
Motor H.P. Overload range
10 HP 13 - 21 A
15 H.P 20 - 32 A
20 H.P 20 - 32 A
30 H.P 28 - 42 A

6 7
THREE PHASE DOL ELECTRONIC THREE PHASE STAR DELTA ELECTRONIC
CONTROL PANEL Input Voltage : 415 V ± 20% VAC
Output Voltage: 415 V ± 20% VAC CONTROL PANEL Input Voltage : 415 V ± 20% VAC
Output Voltage: 415 V ± 20% VAC

(6.1) | DIGI : DOL (7.1) | DCP-9613


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• In Built digital volt& Amp meter ( AVM-101) • Fully Automatic Star delta starter
• With bright LED phase indication with flash • Used latest micro controller based technology
• Automatic rotational phase to phase voltage indication
• Inbuilt Digital volt /Amp Meter
• Thermal overload protection
• Electronic Overload protection
• Short circuit protection through MCB
• Over voltage protection
• Over voltage protection
• Under voltage protection • Under Voltage protection
• Phase Failure Protection • Dry run protection
• Auto Start after resumption of Supply • Current sensing unit
• Powder coated sheet Metal encloser • Phase failure protection
• Reverse phase protection
A pp l i c at i o n :
• For 3 phase DOL Submersible/Monoblock Pump set at irrigation, • Parameters can be programmed

remote farms, unattainable gardening area. • Inbuilt Auto ON/OFF timer


• Powder coated sheet metal enclosure( IP55)
Va r i a n t s :
• Easy to maintain detachable spares
Relay Range
• Remote ON/OFF
4 - 6.5 Amp. 6 - 10 Amp. 9 - 14 Amp. 13 - 21 Amp.
A pp l i c at i o n :
• For three phase star delta motors used in farms, pumping
station, municipal corporation
(6.2) | DCP-9603
Va r i a n t s :
S a l i e n t F e at u r e s :
• Used latest Micro controller based technolgy Overload Overload
Motor H.P. Motor H.P.
• Electronic Start/Stop push button range range
• Inbuilt digital volt & amp Meter 7.5 HP 8 - 20 Amp. 20.0 HP 16 - 40 Amp.
• Digital display of fault condition 10.0 HP 8 - 20 Amp. 25.0 HP 16 - 40 Amp.
• Electronic overload protection 12.5 HP 8 - 20 Amp. 30.0 HP 32 - 80 Amp.
• Over voltage protection
15.0 HP 16 - 40 Amp. 35.0 HP 32 - 80 Amp.
• Under voltage protection
• Dry Run protection
• Parameters can be programmed
• Phase failure protection
• Reverse phasing protection
• Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D)
• Remote ON/OFF
• Powder coated sheet metal enclosure

A pp l i c at i o n :
• Three phase DOL Submersible/Monoblock Pump set
for water in residence, commercial, farming, gardening.
Va r i a n t s :
Current Range
2 - 5 Amp. 4 - 10 Amp. 8 - 20 Amp.

8 9
DUTY STAND BY PANEL FOR DUPLEX PUMPS OPERATION STABILIZER

(8.1) | DUTY STAND BY PANEL FOR (9.1) | SERVO


DUPLEX PUMPS OPERATION S e rv o C o n t r o l l e d V o lta g e S ta b i l i z e r
S a l i e n t F e at u r e s : • I/P: 170V to 270V (For 1 Phase)
• Suitable for Single Phase & Three Phase Power Supply 360V to 460V (For 3 Phase)
• Volt Current and other Fault Conditions Display. • O/P: 215V AC +/- 1% for 1 Phase
• Over voltage, under Voltage and Dry run Protection. 415V AC +/- 1% for 3 Phase
• Pump run and trip indication. • Capacity: Up to 400 KVA
• Singe Phasing, Current and Voltage Sensing Protection. • Cooling: Air Cooled
• Selector/Toggle Switch for pump-1 and pump-2 Oil Cooled
parallel/alternate operation • Balance or Unbalance Type,
• Manual/Auto ON/OFF • Display Parameter: Digital Volt and Amp. Meter
• Sheet metal enclosre with IP-55 Protection • Protection: Over Voltage, Under Voltage, Overload,

Single Phasing Prevention


A pp l i c at i o n :
• Suitable for booster pumps application

Va r i a n t s :
• Up to 35 HP

(9.2) | VIOLTEE
Output Time
Model Input Range Application
Range Delay
220V AC ±
GDMS-20 170V AC – 270V AC
10%
10 Sec. Television
220V AC ±
GDMS-50 170V AC – 270V AC
10%
3 Min. Refrigerator
210V AC –
DLC-50 170V AC – 270V AC
230V AC
10 Sec. Computer

Model Input Range Output Range Time Delay


170V AC – 270V
GDMS - 300 AC
220V AC ± 10% 3 Min.
170V AC – 270V
GDMS - 400 AC
220V AC ± 10% 3 Min.
170V AC – 270V
GDMS - 500 AC
220V AC ± 10% 3 Min.

10 11
AUTO SWITCH MOTOR STARTER

(10.1) | Auto Switch (10.2.1) | GSW


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Voltage sensing unit • I/P: 230 V, 1Phase, AC Supply
• Phase failure protection • ABS Body
• High/Low voltage protection
• Reverse phasing protection
• Over Load Protection
• Engineering grade plastic enclosure (ABS)
• Variable current (Amp.) Setting
• Auto ON after resumption of power supply
• Panel mountable Va r i a n t s :
Type Current Range:
T e c h n i c a l S p e c i f i c at i o n s :
GSW-104 2 - 5 Amp.
• Aux Supply Voltage: 415V AC +/- 20 % , 50 Hz
GSW-105 4 - 10 Amp.
• Phase unbalance volt: 45 V +/- 5 V
GSW-106 8 - 14 Amp.
• Start Time delay: 1 Minute GSW-107 10 - 16 Amp.
• Output: 1 C/O, 6 Amp (Resi.)@ 230 VAC GSW-108 14 - 22 Amp.

A pp l i c at i o n :
• For MCC of water pumps at remote farms, unattaindable area.

(10.2.2) | GSW-T
S a l i e n t F e at u r e s :
• I/P: 230 V, 1Phase, AC Supply,
• ABS Body
• High/Low voltage protection
• Over Load Protection
• Time Delay Facility
• Built in Starter
• Variable current /AMP setting
• Relay Type Switching device

Va r i a n t s :
Type Current Range:
GSW-T-104 2 - 5 Amp.
GSW-T-105 4 - 10 Amp.
GSW-T-106 8 - 14 Amp.
GSW-T-107 10 - 16 Amp.
GSW-T-108 14 - 22 Amp.

12 13
A.C. SWITCH PHASE FAILURE RELAY

((10.2.2) | AaCcSVCH (10.3.1) | PFR-104


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Input Voltage: 85V Ac To 300V Ac • Micro controller based technology
• Current Range: 2A to 16A • Slim in size
• High Voltage Protection : Above 280v
• Higher accuracy
• High Voltage Cut Off: Below 260v
• Voltage sensing unit
• Low Voltage Protection : Below 160v
• Phase failure protection
• Low Voltage Cut in : Above 175v
• Over Load Protection programmable range 2A to 16A • Reverse phasing protection

• Time Delay : 60 sec.(1minute) After resumption of power supply • Engineering grade plastic enclosure (ABS)
• Switching device : Relay • DIN rail mountable
• Unique Alarm system for High voltage, Low voltage,
T e c h n i c a l S p e c i f i c at i o n s :
Over load tripping
• Display of live voltage and live current by seven segment LED • Aux Supply Voltage: 415V AC +/- 20 % , 50 Hz

• Display total run time of your load in hour • Phase unbalance volt: 45 V +/- 5 V
• Tripping delay: 4 to 7 sec
A pp l i c at i o n : • Output: 1 C/O, 6 Amp (Resi.)
• Air-Conditioner, Television, Refrigerator, Domestic Flour Mill
A pp l i c at i o n :
• For MCC of water pumps, generators, compressors

(10.3.2) | PFR-105
S a l i e n t F e at u r e s :
• Micro controller based technology
• Slim in size
• Higher accuracy
• Voltage sensing unit
• Phase failure protection
• Engineering grade plastic enclosure (ABS)
• DIN rail mountable

T e c h n i c a l S p e c i f i c at i o n s :
• Aux Supply Voltage: 415 VAC +/- 20 % , 50 Hz
• Phase unbalance volt: 45 V +/- 5 V
• Tripping delay: 4 to 7 sec
• Output: 1 C/O, 6 Amp (Resi.)

A pp l i c at i o n :
• For MCC of water pumps, generators,compressors

14 15
PHASE FAILURE RELAY MOTOR PROTECTION RELAY

(10.3.3) | PFR-106 (10.4.1) | MGR-101


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Micro controller based technology • Current Sensing unit
• Slim in size • Inverse current characteristics-2
• Micro controller based technology
• Higher accuracy
• Electronic Over load protection
• Voltage sensing unit
• Over voltage protection
• Phase failure protection
• Engineering grade plastic enclosure(ABS)
• Over voltage protection (PFR 106) • DIN rail & Panel Mountable
• Under voltage protection (PFR 106)
• Reverse phasing protection T e c h n i c a l S p e c i f i c at i o n s :
• Aux. Supply voltage 415 +/- 20 % VAC
• Engineering grade plastic enclosure (ABS)
• Over voltage: 120% +/- 5 V of supply voltage
• DIN rail mountable
• Under Voltage : 80 % +/- 5 V of supply voltage
T e c h n i c a l S p e c i f i c at i o n s : • Hysterius
• Aux Supply Voltage: 415V AC +/- 20 % , 50 Hz • Current unbalance Phase-Phase: 50 % of Full Scale current
• Phase unbalance volt: 45V +/- 5 V • Tripping Delay: 4 to 7 Sec.
• Over voltage: Above 480 VAC • Dry run : 40% to 80% of Overload Setting

• Under Voltage: Below 320 V A pp l i c at i o n :


• Tripping delay: 4 to 7 sec • MCC Panels of Water Pumps in hilly area.
• Output: 1 C/O, 6 Amp (Resi.)

A pp l i c at i o n :
• For MCC of water pumps, generators, compressors, Lift (10.4.2) | MGR-102
S a l i e n t F e at u r e s :
• Current & Voltage Sensing unit
• Inverse current characteristics-2
• Micro controller based technology
• Electronic Over load protection
• Over voltage protection
• Under voltage protection
• Phase failure protection
• Reverse phase protection
• Engineering grade plastic enclosure(ABS)
• DIN rail & Panel Mountable

T e c h n i c a l S p e c i f i c at i o n s :
• Aux. Supply voltage 415 +/- 20 % VAC
• Over voltage: 120% +/- 5 V of supply voltage
• Under Voltage : 80 % +/- 5 V of supply voltage
• Current unbalance Phase-Phase: 50 % of Full Scale current
• Voltage Unbalance Phase-Phase : 45 +/- 5 V
• Tripping Delay: 4 to 7 Sec.

A pp l i c at i o n :
• MCC Panels of water pumps.

16 17
PUMP PROTECTION RELAY ANALOG TIMER

(10.5.1) | PGR-101 (10.6.1) | AC-22


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Current Sensing unit • Micro Controller based technology
• Inverse current characteristics • Cyclic timer
• Micro controller based technology • Easy to programme ,through dial on front
• Electronic Over load protection • DIN Rail Mountable
• Over voltage protection • Engineering grade plastic enclosure(ABS)
• Under voltage protection
• Phase failure protection T e c h n i c a l S p e c i f i c at i o n s :
• Reverse phase protection • Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC

• Output 1 c/o, 6Amp.(Resi) at 230VAC • Output: 2 C/O Relay (5A @ 230 VAC)

• Dry run Protection ( Prodless ) • Control Action: Cyclic


• Time Range: 1-10 sec /min/hr. Selectable trough DIP Switch
• Reset: Power On reset

A pp l i c at i o n :
• MCC panel for water pumps, compressors, generators,
airconditioners

(10.5.2) | PGR-102 (10.6.2) | AS-22


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Current & Voltage Sensing unit
• Micro Controller based technology
• Inverse current characteristics
• Single action timer
• Micro controller based technology
• Delay ON/ OFF timer (Selectable )
• Electronic Over load protection
• Easy to programme ,through dial on front
• Over voltage protection
• Under voltage protection • DIN Rail Mountable
• Phase failure protection • Engineering grade plastic enclosure (ABS)
• Reverse phase protection
• Dry Run protection ( Prodless )
T e c h n i c a l S p e c i f i c at i o n s :
• Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC
• Engineering grade plastic enclosure(ABS)
• DIN rail & Panel Mountable • Output: 2 C/O Relay (5A @ 230 VAC)
• Control Action: Selectable Delay ON/OFF
T e c h n i c a l S p e c i f i c at i o n s : • Time Range: 1/3/10/30 sec/min/hr. Selectable trough DIP Switch
• Aux. Supply voltage 415 +/- 20 % VAC
• Reset: Power On reset
• Over voltage: 120% +/- 5 V of supply voltage
• Under Voltage : 80 % +/- 5 V of supply voltage A pp l i c at i o n :
• Current unbalance Phase-Phase: 50 % of Full Scale current • MCC panel for water pumps, compressors, generators
• Voltage unbalance Phase-Phae : 45 V +/- 5 V
• Dry Run : 40 % to 80 % of overload setting
• Tripping Delay: 4 to 7 Sec.

A pp l i c at i o n :
• MCC Panels of water pumps in hilly area

18 19
ANALOG TIMER DIGITAL TIMER

(10.6.3) | AS-21 (10.6.1) | DT-48


S a l i e n t F e at u r e s : T e c h n i c a l S p e c i f i c at i o n s :
• Micro Controller based technology • Supply: 230V AC ± 20%, 50 Hz
• Single Action timer
• Output: 2 C/O Relay (5A @ 230 VAC)
• Delay ON/OFF timer (Factory set)
• Control Action: Selectable Delay On/Off
• Higher Accuracy
• Time Range: 0-99.9 hr./min./sec.
• Easy to programme ,through dial on front
• DIN Rail Mountable • Display: 0.4” Seven Segment LED

• Engineering grade plastic enclosure(ABS) • Accuracy: ± 0.01% of FSD

T e c h n i c a l S p e c i f i c at i o n s :
• Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC
• Output: 1 C/O Relay (5A @ 230 VAC)
• Control Action: Delay ON/ Delay OFF
• Time Range: 0-60 sec
• Reset: Power On reset

A pp l i c at i o n :
• MCC panel for water pumps, compressors,generators , airconditioners

(10.6.4) | SD-22
S a l i e n t F e at u r e s :
• Micro Controller based technology
• Star Delta timer
• Din rail Mountable
• Higher Accuracy
• Easy to programme
• Engineering grade plastic Encloser(ABS)

T e c h n i c a l S p e c i f i c at i o n s :
• Supply: 110/230/415V AC ± 20% 50 Hz
• Output: 2 No. 1 C/O (230V AC, 6A)
• Time Range: y run up time 30/60 sec y to
Δ change over time 30-100msec
• Reset: Power On Reset

A pp l i c at i o n :
• MCC panel for Star Delta pumps set.

20 21
DIGITAL TIME SWITCH EARTH LEAKAGE RELAY

(10.7.1) | DTS-502 (10.8.1) | ELR-101


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Micro Controller Based technology
• Micro controller based technology
• Higher precision
• On/ Off time is programmable
• Panel/Surface mountable
• 10 No of programme for On/Off
• Parameters are settable through knob in front panel
• Display of real time clock
• Engineering grade plastic enclosure( ABS)
• LED display of unit On
• With CBCT
• Easy to programme
• Engineering grade plastic enclosure (ABS) T e c h n i c a l S p e c i f i c at i o n s :
• Auxiliary Supply: 110/280/415v, 50 HZ,
T e c h n i c a l S p e c i f i c at i o n s : • Relay Contact: 1 C/O contact with 6 Amp.
• Input Supply: 230 +/- 20 % VAC • Resistive load at 230v AC,
• Output Supply: 230 +/- 20 % VAC • Leakage Current Range:
• Capacity: 20 amp at 230 VAC (Resi.)
30 to 100 mA
0.1 to 1 Amp
A pp l i c at i o n :
0.5 to 5 Amp.
Water pump, Street lights
• Reset: Manual
• Operating Temp. : -5°C to 60°C
• CBCT : 70,100,200,300 & 400mm
(10.7.2) | DTS-601
A pp l i c at i o n :
S a l i e n t F e at u r e s :
Distribution panels for hotels, commercial complex,
• Micro controller based technology
residential blocks, industrial complex. Mining industry
• On/ Off time is programmable
• 10 No of programme for On/Off
• Display of real time clock
• LED display of unit On
• Easy to programme
• Engineering grade plastic enclosure (ABS)

T e c h n i c a l S p e c i f i c at i o n s :
• Input Supply:415 +/- 20 % VAC
• Output :Potential Free 1 Contact,6 amp at 230 VAC (Resi.)

A pp l i c at i o n :
• Water pump, street lights

22 23
EARTH LEAKAGE RELAY EARTH LEAKAGE CIRCUIT BREAKER

(10.8.2) | ELR-9601 (10.9.1) | EL+MCB


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Micro Controller Based technology • Load Current Rating: 16A / 25A / 32A
• Higher precision • System Voltage: 230V AC, 1 Phase, 50Hz,
• DIN standard flush mountable(92x92)
• Sensitivity: 3-50 mA,
• Digital display of leakage current
• Tripping Time: <30 ms.
• Parameters are programmable
• High/Low Voltage Cut off,
• Engineering grade plastic enclosure( ABS)
• With CBCT • Overload – Short Circuit Protection

T e c h n i c a l S p e c i f i c at i o n s :
• Supply Voltage : 75-275V AC/DC, 50/60 Hz 415V AC,
• 50Hz ± 15%
• Relay contact : 1 change over
• Potential free contact
• Positive safety output (Relay will energies on fault)
• Contact Rating: 6A at 230V AC / 30V DC
• Leakage current range : 50-999mA
• Trip time set: 0.05 to 5 Sec.
• Display: Digital 7seg. LED display
• Operating temp. : -5°c to 60°c
• CBCT 70, 100, 200, 300 & 400mm

A pp l i c at i o n :
Distribution panels for hotels, commercial complex, residential
blocks, industrial complex. Mining industry.

24 25
PANEL METERS AUTOMATIC LIGHT CONTROLLER

(10.10) | AVM-101 (10.11.1) | AUTOPHOTO


S a l i e n t F e at u r e s : Type AMPR PHASE APPLICATION
• Micro Controller Based technology ALC – 6 ( I ) 1 6 Amp 1 Phase Indoor application
• Inbuit C.T.
ALC – 10 ( I ) 1 10 Amp 1 Phase Indoor application
• Indicates phase –phase voltage
• Indicates system current ALC – 10 ( O ) 1 10 Amp 1 Phase Indoor application

• Indication for phase through high bright LED ALC – 25 ( I ) 1 25 Amp 1 Phase Indoor application
• Voltage indiaction rotate at fixed interval for different phase-phase
ALC – 25 ( O ) 1 25 Amp 1 Phase Indoor application
• Panel mountable
ALC – 16 ( O ) 3 16 Amp 1 Phase Indoor application
T e c h n i c a l S p e c i f i c at i o n s :
• Aux. Supply : 415 +/- 20 % VAC ALC – 32 ( O ) 3 32 Amp 1 Phase Indoor application
• Amp. Range : 4-40 Amp, 10-100 Amp
ALC – 63 ( O ) 3 63 Amp 1 Phase Indoor application

A pp l i c at i o n :
Control Panels for housing, water pumps, industries,
residential complex etc.

26 27
SPP WITH WATER LEVEL GUARD WATER LEVEL CONTROLLER

(10.12.1) | SWG (10.13.1) | LLC-101


S a l i e n t F e at u r e s : S a l i e n t F e at u r e s :
• Phase failure relay with dry run protection ( with Prod) • Easy to install
• DIN rail/ Panel mountable
• Voltage sensing unit
• Two tank controller
• Over voltage protection
• Automatic control of starter according to set water level in tanks
• Under voltage protection
• LED indications for water level in tank
• Engineering grade plastic (HIPS) enclosure • Specially for three phase motor starters
• Panel mountable • Availabe with S.S Sensors/Magnetic sensors/Float switch
• Available with S.S. Sensor. • Engineering grade plastic enclosure(ABS)

T e c h n i c a l S p e c i f i c at i o n s : T e c h n i c a l S p e c i f i c at i o n s :
• Aux Supply: 415 +/- 20 % VAC, 50 Hz • System Voltage: 415 VAC +/- 20 % , 50 Hz
• Output : 1 C/O , 6Amp @ 230 AC (Resi.) • Output : 1 CO contact ,1 Amp. At 415 VAC, Pf=0.5

• Over voltage: Above 480 VAC


A pp l i c at i o n :
• Under voltage : Below 320 VAC MCC of water pump in hotels, housed, high rise towers,
societies, industries, commercial complexes, municipal water stations.
A pp l i c at i o n :
MCC for sewage pumps

(10.13.2) | LLC-2
S a l i e n t F e at u r e s :
• Easy to install
• Panel mountable
• Two tank controller
• Automatic control of starter according to set water level in tanks
• LED indications for water level in tank
• Specially for single phase motor starters
• Availabe with S.S Sensors/Magnetic sensors/Float switch
• Engineering grade plastic enclosure(ABS)

T e c h n i c a l S p e c i f i c at i o n s :
• System Voltage: 230 VAC +/- 20 %, 50 Hz
• Output Voltage: 230 VAC +/- 20 %, 50 Hz
• Capacity 30 A at 230 VAC ( Resi.)

A pp l i c at i o n :
MCC of water pump in hotels, housed, high rise towers, societies,
industries, commercial complexes, municipal water stations.

28 29
WATER LEVEL CONTROLLER

(10.13.3) | LLC-2S
S a l i e n t F e at u r e s :
• Easy to install
• Two tank controller
• Automatic control of starter according to set water level in tanks
• LED indications for water level in tank
• Specially for single phase submersible semi automatic
motor starters
• Availabe with S.S Sensors/Magnetic sensors/Float switch
• Engineering grade plastic enclosure(ABS)

T e c h n i c a l S p e c i f i c at i o n s :
• System Voltage: 230 VAC +/- 20 % , 50 Hz
• Output Voltage: 230 VAC+/- 20 %, 50 Hz
Capacity 30 A at 230 VAC ( Resi.)

A pp l i c at i o n :
MCC of water pump in hotels, housed, high rise towers, societies,
industries, commercial complexes, municipal water stations.

(10.13.4) | LLC-001/LLC-001D
S a l i e n t F e at u r e s :
• Water Level controller adopter
• Usefull with GELCO make single or three phase DOL or
• FASD starters having adopter facility only
• Easy to install
• Panel mountable
• Two tank controller
• Automatic control of starter according to set water level in tanks
• LED indications for water level in tank
• Availabe with S.S Sensors/Magnetic sensors/Float switch
• Engineering grade plastic enclosure (ABS)
• For GELCO starter having micro controller based technology use
LLC-001 D

A pp l i c at i o n :
Motor starter of water pump in hotels, housed, high rise
towers, societies, industries, commercial complexes,
municipal water stations.