Professional Documents
Culture Documents
I. NOMENCLATURE
α Aspect ratio
β Overlap ratio
ρ Density [kg/m3]
ω Angular velocity [rad/s]
θ Angle of attack [rad]
d Diameter of the Blade [m]
D Diameter of rotor [m]
e Gap between two paddles [m]
F Force of turbine [N] Fig. 1 Savonius Rotor
G Coefficient of gravity [m/s2]
H Height of turbine [m] Different designs of water current turbine are available for the
i Number of angle of attack extraction of energy from the river water or canals. Based on
n Number of force on the rotor the alignment of the rotor axis with respect to water flow,
N Rotation velocity [rpm] turbine can be classified as (1) horizontal axis turbine (axial
P Power [watts] turbines) and (2) vertical axis turbine (cross flow turbines).
r Radius [m] The commonly used vertical axis turbines are Savonius
T Torque of model [Nm] turbine, helical turbine, Darrieus turbine and H-shaped
V Current velocity [m/s] Darrieus turbine. [3]
SUBSCRIPT Figure 2 indicates comparision of coefficient of power of
r Rotor some of the hydro kinetic turbines, at different Tip Speed
s Shaft Ratio (λ).
II. INTRODUCTION
The recent increase in the price of crude oil has reminded
many quarters on the transient nature of fossil fuel. On the
other hand, environmental issues are forcing governments to
consider the incentives for development of alternative clean
sources of energy.
Published By:
Retrieval Number: B1572053213/2013©BEIESP Blue Eyes Intelligence Engineering
379 & Sciences Publication
Investigation of Overlap Ratio for Savonius Type Vertical Axis Hydro Turbine
β= 0 β=0.1 β=0.2
(a)
Fig. 3. Schematic diagram of a Savonius rotor.
C. Overlap Ratio
The equation for the overlap ratio is given by
Published By:
Retrieval Number: B1572053213/2013©BEIESP Blue Eyes Intelligence Engineering
380 & Sciences Publication
International Journal of Soft Computing and Engineering (IJSCE)
ISSN: 2231-2307, Volume-3, Issue-2, May 2013
C. Simulation Results
The analysis is done using above parameters β= 0, 0.1, and
0.2 and for four different configurations. Figure 7 (a to d)
shows pressure contour of simulation condition at 0°, 45°,
90°, and 135°.
0 45˚ 90˚ From the simulation results, forces on the blades are found
(b) from which the torque on turbine is calculated. The forces on
Fig. 5. (a) Overlap ratio configuration and (b) Angle of attack. every rotor blade for every angle were calculated to provide
the resultant force, based on Figure 7.
Three different overlap ratios are studied, i.e. β= 0, 0.1, and
0.2, as shown in Fig. 5(a). All configurations are evaluated for
four different orientations as shown in Fig. 5 (b).
B. Computational Domain and Initial Mesh
The computational domain used in simulation is shown in Fig.
5. Fig. 6 indicates initial mesh for one of the configuration
(β=0.2). Other computational parameters used in study is
shown in Table 2.
(a) θ = 0˚
(c) θ = 90˚
SR.N
(d) θ = 135˚
INPUT VALUE
O
1 Domain motion Rotating Figure7. Contour of pressure for different angle of attack
2 Angular Velocity 30 to 60 RPM Figure 7 shows the direction and distance of force from the
Boundary Condition inlet center of the turbine-shaft. The torque at every angle of attack
3 Subsonic
flow (Tθ) can be determined by the following formula:
4 Normal velocity 0.6 m/s n
5 Outlet pressure 1 atm T Fn d
6 Angle of Attack 0,45˚,90˚ & 135˚ n 1
Published By:
Retrieval Number: B1572053213/2013©BEIESP Blue Eyes Intelligence Engineering
381 & Sciences Publication
Investigation of Overlap Ratio for Savonius Type Vertical Axis Hydro Turbine
0 1.014
1 0 45 1.5133 0.9331 3.908
90 -0.2146
135 1.4199
0 0.99727
2 0.1 45 1.6909 1.0131 4.243
90 0.8902
135 0.4742
0 0.95301
3 0.2 45 1.1349 1.0777 4.5133
90 1.0956
135 1.1272
Fig.7 Force direction on the paddle turbine for θ = 45°
TABLE 5 Torque and power developed on Turbine blades
with V = 0.60 m/s and ω = 5.235 Rad/sec
The average torque (Tm) is calculated as follows:
Angular
T Sr.
No
Overlap
Ratio (β)
position
of vanes
Torque
developed
Avg.
Torque
Power
Tm 0
(3) . θ Tθ (Nm) Tm (Nm)
(W)
i
Results of the simulation are given in Table 3 to 6 and 0 0.90153
variations of Cp with reference to TSR are shown in Fig. 8, 9 45 0.5379
and 10. 1 0 0.6107 3.947
90 0.03517
135 0.9682
IV. RESULTS AND DISCUSSIONS 0 0.8964
The calculated instantaneous torque for different overlap 2 0.1
45 1.1689
0.8724 4.567
ratios and at different angular positions is shown in table 3. 90 1.0778
The calculation is done for velocity of 0.6 m/s and at angular 135 0.3465
velocity of 3.14 rad/s. On the base of instantaneous torque, 0 0.94622
average torque and developed power is calculated. 45 0.7121
3 0.2 0.9096 4.762
90 1.1834
TABLE 3 Torque and power developed on Turbine blades 135 0.7969
with V = 0.60 m/s and ω = 3.14 rad/sec
TABLE 6 Torque and power developed on Turbine blades
with V = 0.60 m/s and ω = 6.28 Rad/sec
Angular Angular
position Torque Average Power Avg.
Sr. Overlap
of vanes developed Torque develop
Overlap position Torque
No. Ratio (β) Sr. Torque Power
θ Tθ (Nm) Tm (Nm) ed (W) Ratio of vanes developed
No. Tm (W)
(β) θ Tθ (Nm)
(Nm)
0 1.1351
0 0.86705
45 1.898 45 0.5054
1 0 1.056 3.321 1 0 0.6416 4.029
90 0.42004 90 -0.0271
135 1.056 135 1.2209
0 1.0731 0 0.79796
45 1.9842 45 0.99505
2 0.1 1.3064 4.102 2 0.1 0.7489 4.7034
90 1.2006 90 0.83604
135 0.9676
135 0.3667
0 0.85248
0 0.97684 3 0.2 0.7825 4.914
45 0.6687
45 1.4029
3 0.2 1.3781 4.327
90 1.6439
135 1.4885
Published By:
Retrieval Number: B1572053213/2013©BEIESP Blue Eyes Intelligence Engineering
382 & Sciences Publication
International Journal of Soft Computing and Engineering (IJSCE)
ISSN: 2231-2307, Volume-3, Issue-2, May 2013
V. CONCLUSIONS REFERENCES
The most recommended overlap ratio for this type of turbine [1] Nakajima M; Iio S, Ikeda T (2008), “Performance of Double-step
is β = 0.20 and with increase TSR, coefficient of power Savonius Rotor for Environmentally Friendly Hydraulic Turbine”, J.
increases and coefficient of torque decreases. This is similar of Fluid Sci. and Tech. 3(3):410-419
[2] Ali Arslan , Rizwan Khalid, Zohaib Hassan and Irfan A. Manarvi,
to the results of studies on Savonius turbine for wind turbine “Design and Manufacture of a Micro Zero Head Turbine for Power
applications. The results obtained from simulation are plotted Generation”, international journal of multidisciplinary sciences and
for different overlap ratio as shown in Fig.8, Fig. 9 and Fig. engineering, vol. 2, no. 7, 2011
10. The results indicates that overlap ratio of 0.2 provides [3] Kailash Golecha, T.I. Eldho, S.V. Prabhu, "Influence of the deflector
plate on the performance of modified Savonius water turbine",
highest Cp and Ct among all studied overlap ratios. From Applied Energy, Vol. 88, N. 9, pp. 3207-3217, 2011.
analysis it can be concluded that, maximum Cp of nearly 0.5 [4] Saha U.K., Rajkumar M., “On the performance analysis of Savonius
can be achieved at Tip speed ratio of 1.2 for overlap ratio of rotor with twisted blades”. J Renew Energy 2005:0960–1481
0.2. This simulation study shows that vertical axis Savonius [5] Md. Imtiaj Hassan, Tariq Iqbal, Nahidul Khan, Michael Hinchey,
Vlastimil Masek, “CFD analysis of a Twisted Savonius Turbine”,
turbine has good potentials for low head hydro turbine Memorial University of Newfoundland St. John’s, NL, A1B 3X5,
velocity application. Canada
[6] Jean-luc menet, nachida bouraba, “Increase in the savonius rotors
efficiency via a parametric investigation”, Valenciennes Cedex 9
FRANCE.
[7] Sargolazei J, “Prediction of power ratio and torque in wind turbine
Savonius rotors using artificial neural networks” , Proceedings of the
WSEAS International Conference on Renewable Energy Sources,
Arcachon, France, Page (14-16),2009.
[8] Burcin Deda Altan, Mehmet Atılgan , Aydogan Ozdamar, “An
experimental study on improvement of a Savonius rotor performance
with curtaining”, Experimental Thermal and Fluid Science 32 (2008)
1673–1678
[9] Gupta, R., Biswas, A., Sharma, K. K., “Comparative study of a three
bucket savonius rotor with a combined three bucket Savonius –three
bladed Darrieus rotor”. Renewable Energy, 33, Page
(1974-1981),2008
Fig. 8 CP & CT at overlap ratio β= 0 [10] M.A. Kamoji, S.B. Kedare, S.V. Prabhu, "Experimental
investigations on single stage modified Savonius rotor", Applied
Energy, Vol. 86, 2009, pp. 1064-1073
[11] Vinay p v, “Modified savonius rotor for Domestic power
production”, International Journal of Engineering Science and
Technology (IJEST) ISSN : 0975-5462 Vol. 4 No.07 , 2012
[12] Dobrev I, Massouh F (2011), “CFD and PIV investigation of
unsteady flow through Savonius wind turbine”. Energy Procedia,
Vol. 6, 2011, pp. 711-720
[13] Shamsun nahar, md. Quamrul islam, mohammad ali, “Design,
fabrication and its performance test of a six bladed Savonius rotor”,
international journal of advanced renewable energy research vol.1,
issue. 5, pp. 276-282, 2012
[14] Sanjay W. Rukhande, Shami Pathan,Aditya Kamble, Pratik Kale,
Pankaj Daga and Sagar Pandita, “ Design and development of micro
savonius type vawt”, Proceedings of the NCNTE-2012.
Published By:
Retrieval Number: B1572053213/2013©BEIESP Blue Eyes Intelligence Engineering
383 & Sciences Publication