You are on page 1of 4

ATTACHMENT 1.

NOZZLE CALCULATION: TEST SEPARATOR

Gas Capacity Limitation (based on gas outlet nozzle size)

Given data:

Operating Press. :P = 60 psig


74.7 psia
Operating Temp. :T = 100 degF
560 degR
Gas Compressibility :Z = 0.9

Given data:

Gas Flowrate : Qg = 3.00 MMSCFD


Oil Flowrate : Qo = 2000 BOPD
Water Flowrate : Qw = 2000 BWPD
Gas/Liquid Ratio :R = 750 SCF/bbl

1. Inlet Nozzle (Two-Phase Line)

1/2
ZRT

d= ( ((
Criteria:
11. 9+

1000 v
Q
16 .7 P l ) )
)
v max :v = 80 ft/s
v min :v = 60 ft/s
15 ft/s

ID min :d = 3.97 in 4.00 4000


ID max :d = 4.58 in
8.99 in

Actual ID 6 in OK

2. Liquid Outlet Nozzle (Liquid Line):

1 /2
Ql
(
d= 0 . 012
v )
Criteria:
v max :v = 15 ft/s
v min :v = 3 ft/s

a. Oil Outlet
ID min :d = 1.3 in
ID max :d = 4.0 in
Actual ID 2 in OK

b. Water Outlet
ID min :d = 1.3 in
ID max :d = 2.8 in
Actual ID 2 in OK
ATTACHMENT 1.4

NOZZLE CALCULATION: SCRUBBER

Gas Capacity Limitation (based on gas outlet nozzle size)

Given data:

Operating Press. :P = 40 psig


54.7 psia
Operating Temp. :T = 100 degF
560 degR
Gas Compressibility :Z = 0.9

Given data:

Gas Flowrate : Qg = 15.00 MMSCFD


Oil Flowrate : Qo = 1000 BOPD
Water Flowrate : Qw = 1000 BWPD
Gas/Liquid Ratio :R = 7500 SCF/bbl

1. Inlet Nozzle (Two-Phase Line)

1/2
ZRT

d= ( ((
Criteria:
11. 9+

1000 v
Q
16 .7 P l ) )
)
v max :v = 80 ft/s
v min :v = 60 ft/s
15 ft/s

ID min :d = 10.19 in 4.00 2000


ID max :d = 11.76 in
23.49 in

Actual ID 12 in OK

2. Liquid Outlet Nozzle (Liquid Line):

1 /2
Ql
(
d= 0 . 012
v )
Criteria:
v max :v = 15 ft/s
v min :v = 3 ft/s

ID min :d = 1.3 in
ID max :d = 2.8 in
Actual ID 2 in OK
ATTACHMENT 1.4

NOZZLE CALCULATION: PROD SEPARATOR

Gas Capacity Limitation (based on gas outlet nozzle size)

Given data:

Operating Press. :P = 30 psig


44.7 psia
Operating Temp. :T = 100 degF
560 degR
Gas Compressibility :Z = 0.9

Given data:

Gas Flowrate : Qg = 3.00 MMSCFD


Oil Flowrate : Qo = 10000 BOPD
Water Flowrate : Qw = 10000 BWPD
Gas/Liquid Ratio :R = 150 SCF/bbl

1. Inlet Nozzle (Two-Phase Line)

1/2
ZRT

d= ( ((
Criteria:
11. 9+

1000 v
Q
16 .7 P l ) )
)
v max :v = 80 ft/s
v min :v = 60 ft/s
15 ft/s

ID min :d = 5.32 in 4.00 20000


ID max :d = 6.14 in
11.62 in

Actual ID 6 in OK

2. Liquid Outlet Nozzle (Liquid Line):

1 /2
Ql
(
d= 0 . 012
v )
Criteria:
v max :v = 15 ft/s
v min :v = 3 ft/s

a. Oil Outlet
ID min :d = 2.8 in
ID max :d = 8.9 in
Actual ID 3 in OK

b. Water Outlet
ID min :d = 2.8 in
ID max :d = 6.3 in
Actual ID 3 in OK
Gas Capacity Limitation

Given data:
Prod Sep Tes Sep FWKO Scrbber
Operating Press. :P = 60 60 30 40 psig
74.7 74.7 44.7 54.7 psia
Operating Temp. :T = 100 100 100 100 degF
560 560 560 560 degR
Gas Compressibility :Z = 0.99 0.99 0.99 0.99
Gas Outlet Nozzle :d = 10 6 6 12 in
Criteria:
v max :v = 80 80 80 80 ft/s
v min :v = 15 15 15 15 ft/s
60 60 60 60 ft/s

Gas capacity based on gas outlet nozzle size:

2
vd P
Qg=
60TZ

Gas Flowrate : Qg = 17.97 6.47 3.87 18.94 MMSCFD


3.37 1.21 0.73 3.55 MMSCFD
13.47 4.85 2.90 14.21 MMSCFD