GENERAL INFORMATION

GENERAL SPECIFICATIONS
ENGINE MODEL L5774LT/L5794LT L5794GSI L7044GSI
Lubrication System
Sump capacity, including filter
190 gal (719 L) 190 gal (719 L) 190 gal (719 L)
and cooler*
Oil pan (Low level mark) 152 gal (575 L) 152 gal (575 L) 152 gal (575 L)
Oil pan (Full level mark) 173 gal (655 L) 173 gal (655 L) 173 gal (655 L)
Oil filter capacity 7 gal (26.5 L) 7 gal (26.5 L) 7 gal (26.5 L)
(7.25 in. x 52 in.) (7.25 in. x 52 in.) (7.25 in. x 52 in.)
Oil cooler capacity
5 gal (19 L) 5 gal (19 L) 5 gal (19 L)
25 micron at 98.6% efficiency 25 micron at 98.6% efficiency 25 micron at 98.6% efficiency
Paper filter
(absolute) (absolute) (absolute)
20 micron at 90% efficiency 20 micron at 90% efficiency 20 micron at 90% efficiency
Micro-fiberglass filter
(minimum) (minimum) (minimum)
Normal oil pressure 55 ± 5 psi (380 ± 35 kPa) 55 ± 5 psi (380 ± 35 kPa) 55 ± 5 psi (380 ± 35 kPa)
Low oil pressure alarm setpoint 35 psi (241 kPa) 35 psi (241 kPa) 35 psi (241 kPa)
Low oil pressure shutdown
30 psi (207 kPa) 30 psi (207 kPa) 30 psi (207 kPa)
setpoint
Prelube duration 5 minutes
Normal oil header temperature 180°F (82°C) 180°F (82°C) 180°F (82°C)
Oil header temperature alarm
195°F (91°C) 195°F (91°C) 195°F (91°C)
setpoint
Oil header temperature
205°F (96°C) 205°F (96°C) 205°F (96°C)
shutdown setpoint
Air/Gas Starter
Pneumatic prelube motor,
0.5 pint (0.2 liter) 0.5 pint (0.2 liter) 0.5 pint (0.2 liter)
inline lubricator
Cooling System (Jacket and Auxiliary Cooling Circuits)
Standard air cooler inlet
130°F (54°C)
temperature
Jacket coolant capacity,
107 gal (405 L) 107 gal (405 L) 107 gal (405 L)
engine only
Surge tank capacity (optional) 45.5 gal (172 L) 45.5 gal (172 L) 45.5 gal (172 L)
Intercooler coolant capacity 5.50 gal (21 L) 5.50 gal (21 L) 5.50 gal (21 L)
Oil cooler coolant capacity 6.5 gal (24.6 L) 6.5 gal (24.6 L) 6.5 gal (24.6 L)
Exhaust System
Maximum permissible
backpressure @ rated load See Table 1.15-9 Maximum Allowable Exhaust Backpressure on page 1.15-17.
and speed
Crankcase Breather System
Crankcase vacuum -2 [negative] – 0 inch-H2O. (-51 [negative] – 0 mm-H2O)
Jacket Water Outlet Temperature
Normal: 180°F (82°C) for continuous and intermittent rating
Standard cooling system Alarm: ESM-monitored
Shutdown: ESM-monitored

FORM 6319-2