You are on page 1of 3

E-mail: sales@boreasa.com, URL : www.boreasa.

com
Single stage high pressure radial blower:
C65P1
62.8 x 65.3x 65.1 mm (2.47 x 2.57 x 2.57 in)

∗ Housing and Impeller materials: Medical grade thermoplastics


∗ Lead Wire: 300mm (AWG20 & 24)
∗ Weight: 180 gr. (6.35 oz.)
∗ Operational Temperature: -20 to 60 ºC / -4 to 140ºF
∗ Three Phase Brushless Motor w/ Hall Sensor
∗ Connector # Molex Microfit 43025-1000
∗ Motor Internal Temperature Signal
∗ Note: This blower uses a brushless motor and needs a
driver to operate

Sample working point

NOTES: - Performances are dependent on the driver used and the test conditions. The data in this spec. sheet was obtained using Boreasa test chamber at 20°C (±2°
C) and sea level, and using a Boreasa D50/5/4Q-E2P driver. It may be different than data measured in other conditions or with other drivers.
- When used as a vacuum, the blower performance might be less then shown herein, depending on the operating point.
- Specifications are subject to change without notice.
- Boreasa blowers have been designed and are manufactured to meet the medical device industry requirements. However, it is not possible to test blowers in
all conceivable customer application configurations. Consequently, to be used in life support equipment, blowers must be life tested and validated by cus-
tomers, in their actual application conditions, in a statistically meaningful quantity.

Page 1/3 March 2020


E-mail: sales@boreasa.com, URL : www.boreasa.com

Technical Data
C65P1-12PS-01 C65P1-18PS-01 C65P1-24PS-01
VCC Nominal Voltage V 12 18 24
VCC Voltage Range V 9 ~ 14 10 ~ 21 10 ~ 28
IN freeblowing @Nom. Volt. mA 6,150 4’080 3’430
IN work. point @Nom. Volt. mA 4,270 2’880 2’410
IN static @Nom. Volt. mA 2,290 1’420 1’090
PN work. point @Nom. Volt. W 51.2 51.8 57.08
LInductance mH 0.006 0.013 0.02
RPhase-Phase Ohm 0.037 0.09 0.15
n freeblowing @Nom. Volt. rpm 44,200 45’200 47’200
n work. point @Nom. Volt. rpm 46,800 47’660 49’700
n static @Nom. Volt. rpm 49,500 50’600 52’300
V freeblowing @Nom. Volt. l/min 480 493 530
V work. point @Nom. Volt. l/min 230 238 249
P work. point @Nom. Volt. Pa 7’850 7’900 8’740
P static @Nom. Volt. Pa 9,250 9’010 9’750
2 2
I Inertia g*mm / oz*in 1450 / 0.0795
M Mass g / oz 180 / 6.35
Life10 (measured in Bi-level mode) hours >18’000*
TOperations °C / °F -20 ~ +60 / -4 ~ +140 (in ice free conditions)
TOperations °C / °F -30 ~ +80 / -22 ~ +176
Leads mm / inch 300 / 11.8 (AWG22)
Connector Molex Microfit 43025-1000 (10 wires)
Housing / Impeller Material Medical grade thermoplastic
Ball Bearing 
Tacho 
Motor Internal Temperature Sensor 
*At given working points and cycle.

For informa on, to receive a quotes or to place an order, e-mail us at sales@boreasa.com


Page 2/3 March 2020
E-mail: sales@boreasa.com, URL : www.boreasa.com

Electrical Connections Wire Description Connector Pin


Orange HA Hall sensor A PIN 1
Red HB Hall sensor B PIN 2
Green VHall Vhall 3.5 ... 27 VCC PIN 3
Blue W3 Motorwinding W PIN 4
White IT1 Internal Temperature 1 PIN 5
Brown HC Hall sensor C PIN 6
Yellow GND Ground PIN 7
Grey W1 Motorwinding U PIN 8
Violet W2 Motorwinding V PIN 9
Black IT2 Internal Temperature 2 PIN 10

Blower Limits and Warning ∗ No Hot-Swap allowed


∗ Max. allowed temperature on Heat Sink: 85º C
∗ Max. cont. speed: 60’000 rpm
∗ Max. cont. current allowed at 25º C: -12V: 12.8 A
-18V: 8.2 A
-24V: 6.4 A
∗ Blocking the impeller may result in damages or destruction of the blower, un-
less current is limited to value listed above.
∗ A minimum air flow is required at VCC higher than Nominal Voltage to avoid the
air in the blower to overheat by compressing and mixing.
Manufacturing System Blowers manufactured by ISO9001-2015 certified manufacturer
Motor Internal Temperature The temperature of the inside of the motor is indicated by the resistance of a NTC.
Signal (IT) The 10 KΩ NTC (EPCOS B57354V2103F060 or PANASONIC ERTJ1VG103FA),
is connected between the IT outputs (PIN5 & PIN10).

Page 3/3 March 2020