Professional Documents
Culture Documents
XCAP Platform
(Post-Processing)
2011. 2. 8
0
TABLE OF CONTENTS
Introduction
Installation
Getting Started
XCAP Operation
XCAP Analysis
1
•Introduction
•Training Objective
To get familiar with configuration and operation of
XCAP analysis tool
•Audiences
RF engineer, wireless network engineer and or
anyone who is involved in network optimization
and or analysis
•Materials
Computer, XCAP software, USB dongle,
supported data log files
2
•Installation
4
•Getting Started
XCAP
Event Analysis Statistics Report
Basic Analysis Features
Report
Map Data Call
5
•Getting Started
•Window Structure
Menu Bar
Tool Bar
Work Space
Work Bar
6
•Getting Started
8
•Getting Started
Default CDF
Panning Pie
Zoom Window Bar
Zoom In Print
Zoom Out Preview
Zoom All Print Page Setting
PDF Graph Setting
9
•Getting Started
Undo Find
Default Distance Circle
Map Panning Remove Lines
Data Panning Set Area
Site Panning Apply All
10
•XCAP Operation
Will be popped up
11
•XCAP Operation
Model Handling
Able to Merge
the existing
models
12
•XCAP Operation
Processing Time:
Log File Size (WCDMA) Processing Time (approx.)
1GB 10 mins
2GB 30 mins
3GB 58 mins
13
•XCAP Operation
14
•XCAP Operation
15
•XCAP Operation
16
•XCAP Operation
and favorite
17
•XCAP Operation
18
•XCAP Operation
Qualcomm DM *.DLF
Move Down
Delete
Legend On/Off 20
•XCAP Operation
• Parameter Tree
Organized Parameter Tree shows
classified parameters
21
•XCAP Operation
22
•XCAP Operation
23
•XCAP Operation
FTP
UDP
24
•XCAP Operation
Event Selection
25
•XCAP Operation
26
•XCAP Operation
27
•XCAP Operation
• Replay Function
Replay in Graph, Table, Map, and Message analysis window
Simultaneously.
28
•XCAP Operation
• Replay Function
Replay window basically shows time, longitude, latitude,
value, as well as further related items for each parameter
29
•XCAP Operation
• Replay Function
“Sync Other Map, Table, Graph” option enables to
move times slot along all active windows
30
•XCAP Operation
•Map Manager
How to import map files? (*tab, *gst, *mws)
Step 1: Select “Tools” from Menu Bar
Click “Options
32
•XCAP Operation
•Map Manager
Step 3: MapLayer Control Window
Will be popped up like this
33
•XCAP Operation
•Map Manager
How to import map files? (BMP, JPG)
Step 1: Right Click on the Map
Configure Image Map
Click “Insert”
34
•XCAP Operation
•Map Manager
How to import map files? (BMP, JPG)
Step 2: Click “Browse” and select BMP/JPG files
click “Open”
35
•XCAP Operation
•Map Export
Map is able to be exported as BMP, JPG, MIF, KML
and TAB formats
36
•XCAP Operation
•BTS Manager
Enable to add, delete, and modify BTS and Repeater
37
•XCAP Operation
•BTS Manager
How to import BTS information?
38
•XCAP Operation
•BTS Manager
Step 2: Select the desired technology
(UMTS, GSM,
UMTS-R, GSM-R
Etc.)
Click “Import”
39
•XCAP Operation
•BTS Manager
Step 3: Set Importing Option Window will be
40
•XCAP Operation
•BTS Manager
BTS / Repeater Display Options
Click “Options
41
•XCAP Operation
•BTS Manager
BTS and Repeater info is able to be exported as Excel format
42
•XCAP Operation
•Statistics
Voice Call Statistics: Call Attempts, Success, Fail, Drop…, KPI
value, Sets Info…
Statistics
PSC Statistics
Setup Event
43
•XCAP Operation
•Statistics
Data Call Statistics: Attempts, Success, Fail, Drop…, Network
Info, Connection Time, Throughput info, KPI, and RRC message
info
44
•XCAP Operation
•Statistics
Specific Technology Statistics:
WiMAX KPI: HO Latency Time, HO Type, HO Success Rate,
Network Entry Latency, Common Parameters: BSID, RSSI, CINR…
GSM KPI: Call Setup, Handover, Call Drop
45
•XCAP Operation
•Statistics
Message Duration Time is calculated between two user desired
events and layer 3 messages
46
•XCAP Operation
FTP LogIn ID Total count of user ID input trial HTTP DNS Query Total count of DNS Query
LogIn PASS Total count of user PW input trial DNS Answe Total count of DNS response
r
LogOn Total count of 230 Log in
3way HS Total count of 3 way handshaking
RETR Total count of RETR command trial
STOR Total count of STOR command trial 4way HS Total count of 4 way handshaking
226 Transfer O Total count of file receive OK RST Total count of RST command trial
K
Get Total count of Get command trial
EMail SMTP 3way H Total count of SMTP 3 way handsh
S aking Put Total count of Put command trial
POP 3way HS Total count of POP3 3 way handsh
aking Rsp Code 2 Total count of Response Code 200,
00, 204, 301 204, 301 and 302
IMAP 3way H Total count of IMAP 3 way handsha and
S king 302
47
•XCAP Operation
•Statistics
Specific Technology Statistics:
LTE HO Statistics: HO Attempt, Success, Failure, Duration
48
•XCAP Operation
49
•XCAP Operation
• Auto Report
Generating reports on an Excel Workbook
50
•XCAP Operation
•Create Report
XCAP allows you to create report in pdf, excel, doc, html, and
51
•Report
Common report
Attach PDP Summary
Accessibility
Area Summary
BM2P Best Signal
BM2P Ranking
Call Statistics
CDF & PDF Graph
CT Call Statistics / Summary
Conditional Cell Coverage
Data Call Throughput
NQI
Parameter Analysis
Packet Service KPI
Voice MOS Report
Test Setting Information 52
•Report
GSM/WCDMA only
GPRS Timeslot Distribution
GSM 2G
CDMA/EVDO only
EVDO Network Test
GSM/WCDMA + CDMA/EVDO
CDMA/GSM Summary
Drop Reason Analysis
Fail Reason Analysis
Handover Event
Handover Status
Server Basis Analysis
53
•Report
WiMAX only
WiBro HO Event
WiBro MCS Statistics
WiBro/WiMAX PS Call Statistics
LTE only
LTE KPI Table
54
•Report
55
•Report
56
•Report
57
•Quick Statistics (From Map)
58
•Quick Statistics (From Graph)
59
•Benchmarking
60
•Benchmarking
61
•Benchmarking
62
•Benchmarking
63
•Benchmarking
64
•Benchmarking
65
•Benchmarking
Ranking Report
66
•XCAP Operation
Parameters
• Filtering
After set everything, click “OK”
Right-click on a parameter in the parameter tree, and select
filter names to apply filter settings in parameter windows
68
•XCAP Operation
• Filtering
1. Unfiltered
Result
2. Apply Filter
3. Filtered Result
3. Filtered Result
69
•XCAP Operation
and intervals.
Define Coverage
Condition
Interest Parameter
Desired Threshold
range
70
•XCAP Operation
• Coverage Info
To apply the coverage info
Example:
Setting Rx Level Sub => 70 :Good
Setting Rx Level Sub < 70: Bad
71
•XCAP Operation
•In-building Analysis
How to import In-building file?
Step 1: Load the desired In-Building log file building
model in XCAP for analysis
Special Row
72
•XCAP Operation
•In-building Analysis
Step 3: Select the right project, right floor, and test points
Project Points
Floor
73
•XCAP Operation
•In-building Analysis
Step 4: Click on the parameters that you are interested in Map
with data/ Graph/ Table will be shown
74
•XCAP Operation
Click “OK”
75
•XCAP Operation
Click “OK”
76
•XCAP Operation
Click “OK”
77
•XCAP Analysis
• Create Favorite
Ability to save a customized parameter window into
78
•XCAP Analysis
• Create Favorite
Procedures to create a favorite:
you wish
79
•XCAP Analysis
•Create Template
Ability to save customized parameter windows as a
Template
80
•XCAP Analysis
•Create Template
Procedures to create a Template:
you wish
Click “OK”
81
•XCAP Analysis
•Create Template
Step 3: A new template is added into template
82
•XCAP Analysis
•Range to Synchronization
Select a slot of data points as “range to sync” aligning the
83
•XCAP Analysis
•Range to Synchronization
Procedures to apply “Range to Syn”
84
•XCAP Analysis
•Create Model
Save the selected range of data into a new model OR
Excluded the selected range of data and save it into a new model
map) by dragging on it
Parameters/KPIs
87
•XCAP Analysis
•Binning
Ability to divide sections into designated area—bin,
10M
Route Binning
88
•XCAP Analysis
•Binning
Binning (Area)
- Extract the representative values based on area
10M
Area Binning
89
•XCAP Analysis
•Binning
Binning (Timing)
User can select sampling rate of log data when it is opened
3 sec sampling
500 ms samp
ling
90
•XCAP Analysis
•Binning
Procedures for binning:
Step 1: Right click on Map analysis window like this:
choose “Binning”
and click “Create Area”
91
•XCAP Analysis
•Binning
Step 3: Area Setting Window will be popped up like this:
92
•XCAP Analysis
•Delta Map
Compare binning result in each area
Procedures for Delta Map:
Step 1: Open more than two (binned) parameter windows in work
space
Step 2: Right click on the opened map analysis window, and select
on Delta Map
Step 3: Delta Map Setting Window is popped up like this:
93
•XCAP Analysis
•Delta Map
Options for selection:
Differences: Calculate differences between the selected parameters.
Match location only and use nearest found location are
available
Normalizing: Calculate only when there are data in same time range
Step 4: The result of Delta Map can be found from Delta Data tree
94
•XCAP Analysis
•Benchmarking
ARG (Accumulative Rod Graph) with Concurrent Merge Option
enables to do Benchmarking Analysis
Concurrent merge option
generates virtual models a
model inside
CDF Concept
95
•XCAP Analysis
•Benchmarking
CDF PDF
96
•XCAP Analysis
•Benchmarking
NQI (Network Quality Indicator) Report
It can be compared maximum 5 parameters and make
rank using customer weight. According to weighting
method, there are NQI type A and B.
97
•XCAP Analysis
98
http://www.accuver.com
Thank You
Accuver : “Accurate + Verified” in Test and Measurement Equipment
99