Declaration of Conformity

Certification number: CTS12020074


Issue date: April 12, 2012
In accordance with the following Applicable Directives:
2006/95/EC Low Voltage Directive
The device, as described herewith, was tested pursuant to applicable test procedure and complies with
the requirements of:

EN 60065: 2002+A1: 2006+A11:2008+A2: 2010

The test results are traceable to the international or national standards.


Applicant: Strong International Ltd
Abdel Hamid Karami Street, A.Abdel Razzak Bldg., Beirut, Lebanon

Manufacturer: Sichuan Digital Telemedia Co., Ltd


No. 57, Mianxing East Road, Mianyang, Sichuan, 621000, China.

Equipment under test: Digital Terrestrial Receiver

Model number: SRT8505, SRT8500, SRT8520

Laboratory Name: Shenzhen Huatongwei International Inspection Co., Ltd


Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China
Tel: 86-755-26748019 Fax: 86-755-26748089
Http: //www.szhtw.com.cn E-mail: master@szhtw.com.cn
Note:
The certification is only valid for the equipment and configuration described ,in conjunction with
the test data detailed above.

The CE mark as shown beside can be used, under the responsibility of the manufacturer, after
completion of an EC Directive of Conformity and compliance with all relevant EC Directive.

Authorized by:
- Page 1 of 53 - Report No.: TRS12020074

TEST REPORT
EN 60065
Audio, Video and Similar Electronic Apparatus
Safety Requirements
Report Reference No......................: TRS12020074
Tested by Ada Guo
(printed name + signature) ...............: ……………………………………

Supervised by Spark Song


(printed name + signature) ...............: ……………………………………

Approved by Tiger Jiang


(printed name + signature) ...............: ……………………………………

Date of issue.....................................: April 12, 2012


Testing Laboratory Name ..............: Shenzhen HuaTongWei International Inspection Co., Ltd.
Address ............................................: Keji Nan No.12 Road, Hi-tech Park, Shenzhen, China
Testing location/ procedure ..............: Same as above
Testing location/ address .................: Same as above
Applicant’s name............................: Strong International Ltd
Address ............................................: Abdel Hamid Karami Street, A.Abdel Razzak Bldg., Beirut,
Lebanon
Test specification:
Standard ...........................................: EN 60065:2002 +A1:2006+A11:2008+A2:2010
Test procedure .................................: CE/LVD
Non-standard test method…………..: N
Test Report Form No......................: IEC60065K
Test Report Form(s) Originator ........: Intertek Semko AB
Master TRF.......................................: Dated 2010-10
Copyright © 2010 Worldwide System for Conformity Testing and Certification of Electrotechnical
Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as
copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from
the reader's interpretation of the reproduced material due to its placement and context.

If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB
Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and
appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description .................... : Digital Terrestrial Receiver
Trade Mark .......................................: STRONG
Manufacturer ....................................: Sichuan Digital Telemedia Co., Ltd
Model/Type reference ......................: SRT8505, SRT8500, SRT8520
Ratings .............................................: AC 100-240V , 50/60Hz, Max.10W
- Page 2 of 53 - Report No.: TRS12020074

List of Attachments (including a total number of pages in each attachment):


Attachment 1: Circuit Diagram, 1 page.
Attachment 2: PCB layout, 3 pages.
Attachment 3: Transformer spec, 2 pages.
Attachment 4: Photo 11 pages.
Summary of testing and conclusions:

Tests performed: Testing location:


The sample(s) tested comply with the requirements of Shenzhen HuaTongWei International
EN60065: 2002 +A1:2006+A11:2008+A2:2010. Inspection Co., Ltd.
locate in Keji Nan No. 12 Road, Hi-tech Park,
Compliance with European Special National Condtions,
Shenzhen, China
Annex ZB, and A – Deviations, Annex ZC, is recorded at
end of this report.
The EUTs passed all the tests.

Summary of compliance with National Differences:

N
- Page 3 of 53 - Report No.: TRS12020074

Copy of marking plate:

Model: SRT8505

Model: SRT8500

Model: SRT8520

Note: other models label same as above except the model name and trade mark.
- Page 4 of 53 - Report No.: TRS12020074

Note: other models label same as above except the model name and trade mark.
- Page 5 of 53 - Report No.: TRS12020074

Test item particulars ..................................................: Digital Terrestrial Receiver


Classification of installation and use ............................: Class II
Supply connection .......................................................: Fixed power cord
.......................................................................................:
Possible test case verdicts:
- test case does not apply to the test object ................ : N/A (N) (Not applicable)
- test object does meet the requirement ...................... : Pass (P)
- test object does not meet the requirement ................ : Fail (F)
Testing:
Date of receipt of test items.......................................... : January 31, 2012
Date(s) of performance of tests.................................... : February 01, 2012 to April 11, 2012
General remarks:
The test results presented in this report relate only to the object tested.
This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.
"(see Enclosure #)" refers to additional information appended to the report.
"(see appended table)" refers to a table appended to the report.

Throughout this report, a point (coma) is used as the decimal separator.


List of test equipment must be kept on file and available for review.

General product information:


1, The apparatus models SRT8505, SRT8500 and SRT8520 are Digital Terrestrial Receiver intended for
general consumer use.
2, Maximum ambient temperature: 40°C.
3, Instructions:
Instructions/users manual was checked in English version only. The information shall be given in a
language acceptable to the country where the apparatus is intended to be sold.
4, Model difference description:

Model Scart Port LED Digital display


SRT8505 Yes Yes
SRT8500 No No
SRT8520 No No

The model SRT8520 is same as SRT8500 except the silk-screen.

We selected a representative model SRT8505 to conduct the tests and investigation.


The unit complies with all applicable tests.

5. The test report TRS12020074 base on original report TRS12010079 to modify, description of changes
as below:
a) Change the name and address of applicant.
b) Change the name and address of manufacture.
c) Change the model name.

Product specification:
USB port load: 0.5A.
Weight: 0.54Kg.
Dimensions: 210(W)X120(D)X40(H)mm
- Page 6 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

3 General requirements P
Safety class of the apparatus .................................: Class II apparatus P

4 General test conditions P


4.1.4 Ventilation instructions require the use of the test box Yes P

5 Marking and instructions P


Comprehensible and easily discernible The rating label is easily P
discernible.
Permanent durability against water and petroleum Compliance was checked P
spirit by rubbing the marking by
hand for 15 s with cloth
soaked with water and cloth
soaked with petroleum
spirit, it was not possible to
remove marking plate after
the test.
5.1 a) Identification, maker .............................................: Details see page 1 P
b) Model number or type reference ..........................: SRT8505, SRT8500, P
SRT8520
c) Class II symbol if applicable ................................: P

d) Nature of supply....................................................: P
e) Rated supply voltage ...........................................: 100-240V P
f) Mains frequency if safety dependant ...................: 50/60Hz P
g) Rated current or power consumption for apparatus N
supplied by supply apparatus for general use ........:
Measured current or power consumption ...............: N
Deviation % (max 10%) ...........................................: N
h) Rated current or power consumption for apparat-us P
intended for connection to an a.c. mains supply......:
Measured current or power consumption ...............: 10W P
Measured current or power consumption for Not such appliance N
Television set ...........................................................:
Deviation % (max 10%) ...........................................: P
5.2 a) Earth terminal Class II apparatus N
b) Hazardous live terminals N
c) Markings on supply output terminals N
5.3 a) Use of triangle with exclamation mark Detail see page 2 P
b) marking on loudspeaker grille, IEC 60417-5036 N
- Page 7 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

5.4 Instructions for use Relevant instruction P


provided in operator manual
in English, other languages
will be provided when the
national approval applied.
5.4.1 a) Mains powered equipment not exposed to dripping Adequate instructions P
or splashing. Warning concerning objects filled with supplied.
liquid, etc.
b) Hazardous live terminals, instructions for wiring No live terminal N
c) Instructions for replacing lithium battery No lithium battery used in N
appliance
d) Class I earth connection warning Class II appliance N
e) Instructions for multimedia system connection P
f) Special stability warning for attachment of the Not such appliance N
apparatus to the floor/wall
g) Warning: battery exposure to heat Only dry batteries used in N
remote controller.
h) Warning: protective film on CRT face No CRT used in appliance N
5.4.2 a-b) Disconnect device: plug/coupler or all-pole mains Plug as disconnection P
switch location, accessibility and markings device. Adequate
information included in User
Instruction
c) Instructions for permanently connected equipment Not such appliance N
Marking, signal lamps or similar for completely P
disconnection from the mains

6 Hazardous radiation P
6.1 Ionizing radiation < 36 pA/kg (0,5 mR/h) No lonizing radiation N
Ionizing radiation under fault condition N
6.2 Laser radiation, emission limits to IEC 60825-1:2007 LEDs for indication P
................................................................................... considered inherently
Emission limits under fault conditions .....................: Class I P

7 Heating under normal operating conditions P


7.1 Temperature rises not exceeding specified values; (see appended table) P
fuse links and other protective devices defeated
7.1.1 Temperature rise of accessible parts (see appended table) P
7.1.2 Temperature rise of parts providing electrical (see appended table) P
insulation
7.1.3 Temperature rise of parts acting as a support or as a (see appended table) P
mechanical barrier
- Page 8 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

7.1.4 Temperature rise of windings (see appended table) P


7.1.5 Parts not subject to a limit under 7.1.1 to 7.1.4 (see appended table) P
7.2 Softening temperature of insulating material N
supporting parts conductively connected to the mains
carrying a current > 0,2 A at least 150 oC

8 Constructional requirements with regard to the protection against electric P


shock
8.1 Conductive parts covered by lacquer, paper, Considered P
untreated textile oxide films and beads etc.
considered to be bare
8.2 No shock hazard when changing voltage setting No such devices used in N
device, fuse-links or handling drawers etc. appliance
8.3 Insulation of hazardous live parts not provided by No hygroscopic materials N
hygroscopic material used.
8.4 No risk of electric shock following the removal of a No cover removable by N
cover which can be removed by hand hand.
8.5 Class I equipment Class II appliance N
Basic insulation between hazardous live parts and N
earthed accessible parts
Resistors bridging basic insulation complying with N
14.1 a)
Capacitors bridging basic insulation complying with N
14.2.1 a)
Protective earthing terminal N
8.6 Class II equipment and Class II constructions within Class II appliance P
Class I equipment
Double or reinforced insulation between hazardous Complied P
live parts and accessible parts
Components bridging reinforced or double insulation Double/Reinforced P
complying with 14.1 a) or 14.3 insulation complies with
requirements specified in
clause 10 and 13.
Basic and supplementary insulation each being N
bridged by a capacitor complying with 14.1 a)
Reinforced or double insulation being bridged with 2 N
capacitors in series complying with 14.2.1 a)
Reinforced or double insulation being bridged with a Y1 (CY902) capacitor used P
single capacitor complying with 14.2.1 b)
Basic insulation bridged by components complying N
with 14.3.4.3
8.7 This clause is void N
- Page 9 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

8.8 Basic or supplementary insulation > 0,4 mm (mm) : No such insulation used N
Reinforced insulation > 0,4 mm (mm) ....................: Thickness of transformer P
bobbin and insulation sheet
exceed 0.4mm
Thin sheet insulation (excluding non-separable thin P
sheet insulation. See 8.22)
Basic or supplementary insulation, at least two layers, N
each meeting 10.3
Basic or supplementary insulation, three layers any N
two of which meet 10.3
Reinforced insulation, two layers each of which meet N
10.3
Reinforced insulation, three layers any two which 3 layers of insulation tape P
meet 10.3 used in transformer
8.9 Adequate insulation between internal hazardous live P
conductors and accessible parts
Adequate insulation between internal hazardous live P
parts and conductors connected to accessible parts
8.10 Double insulation between conductors connected to Double or reinforced P
the mains and accessible parts. insulation provided between
conductors connected to
the mains and accessible
parts
Double insulation between internal hazardous live P
parts and conductors connected to accessible parts.
8.11 Detaching of wires No wire could become N
detachable
No undue reduction of creepages or clearance P
distances if wires become detached
Vibration test carried out .........................................: P
8.12 This clause is void N
8.13 Adequate fastening of windows, lenses, lamp covers Adequately fastened P
etc. (pull test 20 N for 10 s)
8.14 Adequate fastening of covers (pull test 50 N for 10 s) Covers adequately P
fastened with screws. Pull
test complied
8.15 No risk of damage to the insulation of internal wiring No risk of damage to P
due to hot parts or sharp edges insulation due to high
temperature, sharp edges
or pinches
8.16 Only special supply equipment can be used N
8.17 Insulated winding wire without additional interleaved No such insulated wire N
insulation used
- Page 10 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

8.18 Endurance test as required by 8.17 Test not required N


8.19 Disconnection from the mains P
8.19.1 Disconnect device The plug attached power P
cord will be considered as
disconnect device
All-pole switch or circuit breaker with >3mm contact N
separation
8.19.2 Mains switch ON indication No switch used N
8.20 Switch not fitted in the mains cord N
8.21 Bridging components comply with clause 14 See the clause 14.2.1 P
8.22 Non-separable thin sheet material No such part used N

9 Electric shock hazard under normal operating conditions P


9.1 Testing on the outside P
9.1.1 For voltages >1000 V ac or >1500 V dc complies No parts with voltages N
with clause 13.3.1 for basic insulation exceeding 1000V AC or
1500V DC.
9.1.1.1 a) Open circuit voltages Mains input voltage > P
35Vac. See below.
b) Touch current measured from terminal devices See attachment P
using the network in annex D .................................:
c) Discharge not exceeding 45 μC No part or contact of a N
terminal carrying exceeds
45μC for stored charges.
d) Energy of discharge not exceeding 350 mJ No part or contact of a N
terminal with stored
voltages exceeding 15kV.
9.1.1.2 Test with test finger and test probe Considered P
9.1.2 No hazardous live shafts of knobs, handles or levers No live shafts, handles or N
levers
9.1.3 Ventilation holes and other holes tested by means of No hazards P
4 mm x 100 mm test pin
9.1.4 Terminal devices tested with 1 mm x 20 mm test pin Does not reach hazardous P
(10 N); test probe D of IEC 61032 live parts
Terminal devices tested with 1 mm x 100 mm straight Straight wire did not P
wire (1 N); test probe D of IEC 61032 become live
9.1.5 Pre-set controls tested with 2.5 mm x 100 mm test pin No such control sued in N
(10 N); test probe C of IEC 61032 appliance
9.1.6 No shock hazard due to stored charge on withdrawal No such capacitors used N
of the mains plug; voltage (V) after 2 s ...................:
If C is not greater than 0,1 μF no test needed N
- Page 11 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

9.1.7 a) Enclosure sufficiently resistant to external force No damage to the P


enclosure
Test probe 11 of IEC 61032 for 10 s (50 N) Test with test finger results P
in no hazard
b) Test hook of fig. 4 for 10 s (20 N) Test with test hook results P
in no hazard
c) 30 mm diameter test tool for 5 s (100 or 250 N) : Test with 100N results in no P
damage
9.2 No hazard after removing a cover by hand No cover removable by P
hand

10 Insulation requirements P
10.1 Insulation resistance (MΩ) at least 2 MΩ min. after After surge test >100MΩ. P
surge test for basic and 4 MΩ min. for reinforced Complied.(after dielectric
insulation .................................................................: strength test)
10.2 Humidity treatment 48 h or 120 h ...........................: Performed for 48h at temp. P
30°C and a relative
humidity 95%
10.3 Insulation resistance and dielectric strength between (see appended table) P
mains teminals
Insulation Resistance and dielectric strength across N
BASIC or SUPPLEMENTARY insulation (Class l)
Insulation resistance and dielectric strength across P
REINFORCED insulation (Class II)

11 Fault conditions P
11.1 No shock hazard under fault condition No electric shock hazard P
under fault conditions
11.2 Heating under fault condition See below P
Flames extinguish within 10 seconds No flames P
No hazard from softening solder Neither danger of fire to P
surroundings nor abnormal
heat developed
Flames extinguish within 10 seconds No flames P
Soldered terminations not used as protective No soldered terminations P
mechanism used as protective
mechanism
11.2.1 Measurement of temperature rises (see appended table) P
11.2.2 Temperature rise of accessible parts (see appended table) P
11.2.3 Temperature rise of parts, other than windings, (see appended table) P
providing electrical insulation
- Page 12 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

11.2.4 Temperature rise of parts acting as a support or P


mechanical barrier
11.2.5 Temperature rise of windings (see appended table11.2) P
11.2.6 Temperature rise of parts not subject to the limits of No excessive temperature P
11.2.1 to 11.2.5 observed/measured on
other parts. (see appended
table 11.2)
Temperature rise of printed circuit boards (PCB) The temperature rise of N
exceeding the limits of table 3 by max. 100 K for max. PCB board does not
5 min exceed the limit of table 3
a) Temperature rise of printed circuit boards (PCB) to N
20.1.3, exceeding the limits of table 3 by not more
than 100 K for an area not greater than 2 cm²
b) Temperature rise of printed circuit boards (PCB) to N
20.1.3 up to 300 K for an area not greater than 2 cm²
for a maximum of 5 min
Meets all the special conditions if conductors on N
printed circuit boards are interrupted
Class I protective earthing maintained Class II appliance N
11.2.7 Temperature rise of parts not subject to the limits of (see appended table 11.2) P
11.2.1 to 11.2.6 shall not exceed the limits in table 3,
item e), "Fault conditions".

12 Mechanical strength P
12.1.1 Bump test where mass >7 kg 0.54kg N
12.1.2 Vibration test After the test, no damage, P
no part or connection was
loose.
12.1.3 Impact hammer test The apparatus withstand P
the dielectric strength test
and no damage after the
test
Steel ball test The apparatus withstand P
the dielectric strength test
and no damage after the
test
12.1.4 Drop test for portable apparatus where mass < 7 kg The apparatus withstand P
the dielectric strength after
drop test
12.1.5 Thermoplastic enclosures strain relief test No hazardous after test P
12.2 Fixing of knobs, push buttons, keys and levers P
12.3 Remote controls with hazardous live parts Remote-controls does not P
include hazardous live part
12.4 Drawers (pull test 50 N, 10 s) No drawers N
- Page 13 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

12.5 Antenna coaxial sockets providing isolation No damage P


12.6 Telescoping or rod antennas construction N
12.6.1 Telescoping or rod antennas securement N

13 Clearances and creepage distances P


13.1 Clearances in accordance with 13.3 (See appended table 13) P
Creepage distances in accordance with 13.4 (See appended table 13) P
13.2 Determination of working voltage The rms and peak voltage P
of the appliance is mains
voltage 240V max. The unit
was connected to a 240V
TN power system. The
highest operating voltages
are measured on
transformers.
(See appended table 13)
13.3 Clearances P
13.3.1 General P
13.3.2 Circuits conductively connected to the mains comply (see appended table 13) P
with table 8 and, where applicable, table 9
13.3.3 Circuits not conductively connected to the mains N
comply with table 10
13.3.4 Measurement of transient voltages N
13.4 Creepage distances P
Creepage distances greater than table 11 minimum (see appended table 13) P
13.5 Printed boards P
13.5.1 Clearances and creepage distances between No such PCB used N
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
13.5.2 Type B coated printed circuit boards complying with Not type B coated PCB N
IEC 60664-3 (basic insulation only)
13.6 Conductive parts along uncemented joints clearances No uncemented joints N
and creepage distances comply with 13.3 and 13.4
Conductive parts along reliably cemented joints N
comply with 8.8
Temperature cycle test and dielectric strength test N
13.7 Enclosed, enveloped or hermetically sealed parts: not No such component N
conductively connected to the mains: clearances and
creepage distances as in table 12
13.8 Parts filled with insulating compound, meeting the Opto-couplers refer to sub- P
requirements of 8.8 clause 14.11.
- Page 14 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

14 Components P
14.1 Resistors N
a) Resistors between hazardous live parts and No such resistors used N
accessible metal parts
b) Resistors, other than between hazardous live parts N
and accessible parts
Resistors separately approved ...............................: N
14.2 Capacitors and RC units P
Capacitors separately approved P
14.2.1 Y capacitors tested to IEC 60384-14:2005 ............: Y1(CY902) approved by P
VDE
14.2.2 X capacitors tested to IEC 60384-14:2005 ............: No X capacitor N
14.2.3 Capacitors operating at mains frequency but not N
connected to the mains: tests for X2 ......................:
14.2.5 Capacitors with volume exceeding 1750 mm³, where No capacitor has volume N
short-circuit current exceeds 0,2 A: compliance with exceeding 1750 mm³
IEC60384-1, 4.38 category B or better ...................:
Capacitors with volume exceeding 1750 mm³, N
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better .................................................:
Shielded by a barrier acc. To 20.1.4/ table 21 or metal N
..................................................................................:
14.3 Inductors and windings P
Comply with IEC 61558-1, IEC 61558-2 Test with appliance N
(as relevant) and clause 20.1.4
14.3.1 Transformers and inductors marked with See appended table 14. P
manufacturer’s name and type ...............................:
Transformers and inductors separately approved .: N
14.3.2 General Isolating transformers, ref. P
Transformers spec.
Insulation material complies with clause 20.1.4 Insulation material complies P
with table 21 on
flammability class
14.3.3 Constructional requirements P
14.3.3.1 Clearances and creepage distances comply with See attachment: Tables to P
clause 13 IEC 60065 7th edition
14.3.3.2 Transformers meet the constructional requirements See attachment: Tables to P
IEC 60065 7th edition
14.3.4 Separation between windings P
- Page 15 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

14.3.4.1 Class II transformers have adequate separation Double or reinforced P


between hazardous live parts and accessible parts insulation between primary
(double or reinforced insulation) and secondary windings
according to clause 8.8 See
table in clause 14.3.3-5
Coil formers and partition walls > 0,4 mm More than 0.4mm P
14.3.4.2 Class I transformers, with basic insulation and No such transformer used. N
protective screening only if all 7 conditions of 14.3.4.2 Windings are of Class II
are met construction
14.3.4.3 Separating transformers with at least basic insulation Windings of Class II N
construction used.
14.3.5 Insulation between HAZARDOUS LIVE parts and P
ACCESSIBLE parts
14.3.5.1 Class II transformers have adequate insulation Double or reinforced P
between hazardous live parts and accessible parts insulation between
(double or reinforced insulation) hazardous live windings
and accessible conductive
parts
Coil formers and partition walls > 0,4 mm More than 0.4mm P
14.3.5.2 Class I transformers have adequate insulation Windings of class II N
between hazardous live parts and accessible construction used
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
Winding wires connected to protective earth have N
adequate current-carrying capacity
14.4 High voltage components N
High-voltage components and assemblies: U > 4 kV No high voltage N
(peak) separately approved components.
Component meets category V-1 of IEC 60695-11-10 N
14.4.1 High voltage transformers and multipliers tested as N
part of the submission
14.4.2 High voltage assemblies and other parts tested as N
part of the submission
14.5 Protective devices P
Protective devices used within their ratings Current fuse used in P
appliance
External clearances and creepage distances meet The main fuse separately P
requirement of clause 13 for the voltage across the approved 2.6mm CL and
device when opened CR between fuse terminals.
14.5.1.1 a) Thermal cut-outs separately approved No thermal cut-outs N
b) Thermal cut-outs tested as part of the submission N
14.5.1.2 a) Thermal links separately approved No thermal links N
- Page 16 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

b) Thermal links tested as part of the submission N


14.5.1.3 Thermal devices re-settable by soldering N
14.5.2.1 Fuse-links in the mains circuit according to IEC 60127 See list of critical N
components
14.5.2.2 Correct marking of fuse-links adjacent to holder ....: Fuse marked on PCB P
adjacent to component as:
F902 T1A/ 250VAC
14.5.2.3 Not possible to connect fuses in parallel ................: Not possible to connect P
fuses in parallel.
14.5.2.4 Not possible to touch hazardous live parts when No replacement of fuse N
replacing fuse-links without the use of a tool ..........: possible by hand
14.5.3 PTC-S thermistors comply with IEC 60730-1 No PTC used N
PTC-S devices (15 W) category V-1 or better N
14.5.4 Circuit protectors have adequate breaking capacity Only standard fuse used N
and their position is correctly marked
14.6 Switches N
14.6.1 a) Separate testing to IEC 61058 including: N
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
14.6.1 b) Tested in the apparatus: N
Switch controlling > 0.2A with open contact voltage > N
35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 and
V-0 in annex G, G.1.1
Switch controlling > 0.2A with open contact voltage < N
35 V (peak)/24 V dc complying with 14.6.3 and V-0 in
annex G, G.1.1
Switch controlling < 0.2A with open contact voltage > N
35 V (peak)/24 V dc complying with 14.6.4 and V-0 in
annex G, G.1.1
14.6.2 Switch tested to 14.6.1 b) constructed to IEC 61058-1 N
subclause 13.1 and has making/breaking action
independent of speed of actuation
14.6.3 Switch tested to 14.6.1 b) compliant with IEC 61058-1 N
subclause 16.2.2 d) and m) not attaining excessive
temperatures in use
14.6.4 Switch tested to 14.6.1 b) has adequate dielectric N
strength
14.6.5 Mains switch controlling mains socket outlets N
additional tests to IEC 60058-1
- Page 17 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

Socket outlet current marking correct N


14.7 Safety interlocks No safety interlocks N
Safety interlocks to 2.8 of IEC 60950 N
14.8 Voltage setting devices and the like No such device N
Voltage setting device not likely to be changed N
accidentally
14.9 Motors No motor used N
14.9.1 Endurance test on motors N
Motor start test N
Dielectric strength test N
14.9.2 Not adversely affected by oil or grease etc. N
14.9.3 Protection against moving parts N
14.9.4 Motors with phase-shifting capacitors, three-phase N
motors and series motors meet clause. B.8, B.9 and
B.10 of IEC 60950, Annex B
14.10 Batteries No batteries provided. N
14.10.1 Batteries mounted with no risk of accumulation of N
flammable gases
14.10.2 No possibility of recharging non-rechargeable N
batteries
14.10.3 Recharging currents and times within manufacturers N
limits
Lithium batteries discharge and reverse currents N
within the manufacturers limits

14.10.4 Battery mould stress relief N


14.10.5 Battery drop test N
14.11 Optocouplers See list of critical P
components
a) Comply with 13.6 (jointed insulation) and N.2.1 P
b) Comply with IEC 60747-5-5:2007 P
Alternative to a) and b) optocoupler comply with 13.8 P
a) Comply with 13.6 (jointed insulation) and N.2.1 P
14.12 Surge suppression varistors No Surge suppression N
varistor used
Comply with IEC 61051-2 N
Not connected between mains and accessible parts N
except for earthed parts of permanently connected
apparatus
- Page 18 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

Complies with the current pulse, fire hazard and N


thermal stress requirements of 14.12

15 Terminals P
15.1.1 Mains plug, appliance inlet, interconnection couplers Mains plug, see list of P
and mains socket-outlet meet the appropriate critical components
standard
Overloading of plugs or appliance inlets prevented if N
the apparatus has mains socket outlets
Overloading of internal wiring prevented if the N
apparatus has mains socket outlets
15.1.2 Connectors for antenna, earth, audio, video or data: P
No risk of insertion in mains socket-outlets P
No risk of insertion into audio or video: outlets marked No outlet used N
with the symbol of 5.2
15.1.3 Output terminals of a.c. adaptors or similar devices No such devices used. N
not compatible with household mains socket-outlets
15.2 Provision for protective earthing N
Accessible conductive parts of Class I equipment Class II apparatus N
reliably connected to earth terminal, within equipment
Protective earth conductors correctly coloured N
Equipment with non-detachable mains cord provided N
with separate protective earth terminal near mains
input
Protective earth terminal resistant to corrosion N
Earth resistance test: < 0,1 Ω at 25 A ....................: N
15.3 Terminals for external flexible cords and for N
permanent connection to the mains supply
15.3.1 Adequate terminals for connection of permanent N
wiring
15.3.2 Reliable connection of non-detachable cords: N
Not soldered to conductors of a printed circuit board N
Adequate clearances and creepage distances N
between connections should a wire break away
Wire secured by additional means to the conductor N
15.3.3 Screws and nuts clamping conductors have adequate N
threads: ISO 261, ISO 262 or similar
15.3.4 Soldered conductors wrapped around terminal prior to N
soldering or held in place by additional means
Clamping of conductor and insulation if not soldered N
or held by screws
- Page 19 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

15.3.5 Terminals allow connection of appropriate cross- N


sectional area of conductors, for the rated current of
the equipment
15.3.6 Terminals to 15.3.3 have sizes required by table 16 N
15.3.7 Terminals clamp conductors between metal and have N
adequate pressure
Terminals designed to avoid conductor slipping out N
when tightened or loosened
Terminals adequately fixed to avoid loosening when N
the clamping is tightened or loosened and stress on
internal wiring is avoided
15.3.8 Terminals carrying a current more than 0,2 A: contact N
pressure not transmitted by insulating material except
ceramic
15.3.9 Termination of non-detachable cords: wires N
terminated near to each other
Terminals located and shielded: test with 8 mm strand N
15.4 Devices forming a part of the mains plug N
15.4.1 No undue strain on mains socket-outlets N
15.4.2 Device complies with standard for dimensions of N
mains plugs
15.4.3 Device has adequate mechanical strength (tests N
a,b,c)

16 External flexible cords P


16.1 Mains cords sheathed type, complying with Mains cords complying with P
IEC 60227 for PVC or IEC 60245 for synthetic rubber IEC60227
cords ........................................................................:
Non-detachable cords for Class I have green/yellow Class II apparatus N
core for protective earth
16.2 Mains cords conductors have adequate cross- Cross sectional area: P
sectional area for rated current consumption of the 0.5/0.75mm2
equipment
16.3 a) Flexible cords not complying with 16.1, used for N
interconnections between separate units of equipment
used in combination and carrying hazardous live
voltages, have adequate dielectric strength
b) Flexible cords not complying with 16.1, withstand N
bending and mechanical stress (3.2 of IEC 60227-2)
16.4 Flexible cords used for connection between N
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
- Page 20 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

16.5 Adequate strain relief on external flexible cords Strain relief: 40N, 100 P
times. Torque test:
0.25Nm. 1 minute
displacement/limit:
0.9mm/2mm
Not possible to push cord back into equipment P
Strain relief device unlikely to damage flexible cord P
For mains cords of Class I equipment, hazardous live N
conductors become taut before earth conductor
16.6 Apertures for external flexible cord: no risk of damage P
to the cord during assembly or movement in use
16.7 Transportable musical instruments and amplifiers N
fitted with detachable cord set with appliance inlet to
IEC 60320-1
Transportable musical instruments and amplifiers N
fitted with detachable cord sets or with means of
stowage to protect the cord

17 Electrical connections and mechanical fixings P


17.1 Torque test to table 20: P
- screws into metal: 5 times See attachment, Table to P
17.1
- screws into non-metallic material: 10 times N
17.2 Correct introduction into female threads in non- N
metallic material
17.3 Cover fixing screws: captive P
Non-captive fixing screws: no hazard when replaced Non-captive fixing screws P
by a screw whose length is 10 times its diameter used, it will not cause a
reduction of clearance and
creepage distance
17.4 No loosening of conductive parts carrying a current N
> 0,2 A
17.5 Contact pressure not transmitted through plastic other No contact pressure N
than ceramic for connections carrying a current transmitted through
> 0,2 A insulating material
17.6 Stranded conductors of flexible supply cords carrying N
a current > 0,2 A with screw terminals not
consolidated by solder
17.7 Cover fixing devices other than screws have adequate N
strength and their positioning is unambiguous
17.8 Fixing devices for detachable legs or stands provided No detachable legs or N
stands provided
17.9 Internal pluggable connections, affecting safety, Connections complies, P
unlikely to become disconnected checked by inspection
- Page 21 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

18 Mechanical strength of picture tubes and protection against the effects of N


implosion
(No such picture tubes used in appliance)
18.1 Picture tube separately approved to IEC 61965 ....: N
Picture tube separately approved to 18.2 ...............: N
18.2 Non-intrinsically protected tubes tested to 18.2 N

19 Stability and mechanical hazards P


Mass of the equipment exceeding 7 kg ..................: 0.54kg N
Apparatus intended to be fastened in place – suitable N
instructions
19.1 Test on a plane, inclined at 10o to the horizontal N
19.2 100 N force applied vertically downwards N
19.3 100 N force, or 13% of weight, applied horizontally to N
point of least stability.
19.4 Edges or corners not hazardous There is no hazardous P
edges or corners
19.5 Glass surfaces (exc.laminated) with an area No glass surface. N
exceeding 0,1 m² or maximum dimension > 450 mm,
pass the test of 19.5.1
19.6 Wall or ceiling mountings adequate Not for wall mounting N

20 Resistance to fire P
20.1 Electrical components and mechanical parts P
a) Exemption for components contained in an N
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
b) Exemption for small components as defined in 20.1 PCB is of flammability class P
V-0 for Power supply board,
V-1 min. for other board (UL
approval) and exception is
made for small
components.
20.1.1 Electrical components meet the requirements of Electrical components P
Clause 14 or 20.1.4 comply with flammability
requirements in clause 14
20.1.2 Insulation of internal wiring working at voltages > 4 Kv No wires working at N
or leaving an internal fire enclosure, or located within voltages > 4kV.
the areas mentioned in Table 21, not contributing to
the spread of fire
- Page 22 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

20.1.3 Material of printed circuit boards on which the All PCB meet V-1 or better P
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or better
to IEC60707, unless used in a fire enclosure
Material of printed circuit boards on which the N
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60695-11-10.
20.1.4 Components and parts not covered by 20.1.1, 20.1.2 N
and 20.1.3 (other than fire enclosures) mounted
nearer to a potential ignition source than the distances
in Table 21 comply with the relevant flammability
category in Table 21
Components and parts as above but shielded from a N
potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
Apparatus with voltages >4kV under normal operating N
conditions and distances to the enclosure exceed
those specified Table 21, flammability classification
HB40 or better is required for the enclosure.
20.2 Fire enclosure Metal enclosure N
20.2.1 Potential ignition sources with open circuit voltage No voltages exceeding 4kV N
> 4 kV (peak) a.c. or d.c. contained in a fire enclosure
to V-1
20.2.2 Internal fire enclosures with openings not exceeding No internal fire enclosure N
1 mm in width and with openings for wires completely
filled
20.2.3 Requirements of 20.2.1 and 20.2.2 met by an internal No internal fire enclosure N
fire enclosure
- Page 23 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

A Annex A, Additional requirements for apparatus with protection against N


splashing water
A.5 Marking and instructions N
A.5.1 j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not N
apply
A.10 Insulation requirements N
A.10.2 Splash and humidity treatment N
A.10.2.1 Enclosure provides protection against splashing N
water
A.10.2.2 Humidity treatment carried out for 7 days N

B Annex B, Apparatus to be connected to the TELECOMMUNICATION N


NETWORKS
Complies with IEC 62151 clause 1 N
Complies with IEC 62151 clause 2 N
Complies with IEC 62151 clause 3 but with 3.5.4 N
modified to 2.4.10 of this standard
Complies with IEC 62151 clause 4 but with 4.1.2, N
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
Complies with IEC 62151 cause 5 but with 5.3.1 N
modified in accordance with annex B of this
standard
Complies with IEC 62151 clause 6 N
Complies with IEC 62151 clause 7 N
Complies with IEC 62151 annex A, B and C N

L ANNEX L, Additional requirements for electronic flash apparatus for N


photographic purposes
L. 5 Marking and instructions N
L. 5.4 Instructions for battery chargers and Supply N
apparatus indicating type or model number of flash
apparatus with which it is to be used
Instructions for flash apparatus indicating type or N
model number of battery chargers or Supply
apparatus with which it is to be used
L. 7 Heating under normal operating conditions N
L7.1.5 & Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of
L11.2.7
IEC 60086-4
L. 9 Electric shock hazard under normal operating conditions N
- Page 24 of 53 - Report No.:TRS12020074
EN 60065
Clause Requirement - Test Result - Remark Verdict

L. 9.1.1 Terminals to connection to synchroniser not N


HAZARDOUS LIVE
L.10 Insulation requirements N
L. 10.3.2 High frequency puls ignition N
L. 12 Mechanical strength N
L. 12.1.3 Windows for flash tubes are excluded from steel N
ball impact test
L. 14 Components N
L14.6.6 Mains switch characteristics appropriate to its N
function under normal conditions
L. 20 Resistance to fire N
L. 20.1 c) Trigger coil for discharge purpose is not N
considered to be a POTENTIAL IGNITION
SOURCE
- Page 25 of 53 - Report No.: TRS12020074

7.1 TABLE: temperature rise measurements: P


Power consumption in the OFF/Stand-by mode of 0.5W in stand-by mode
the functional switch (W) ......................................... :
Cond. Un (V) Hz In (A) Pn (W) Uout (V) Pout (W) Operating Condition / Status
1 90V 50 0.177 9.30 -- -- Normal condition with USB load 0.5A
2 90V 60 0.179 9.26 -- -- Normal condition with USB load 0.5A
3 100V 50 0.162 9.20 -- -- Normal condition with USB load 0.5A
4 100V 60 0.164 9.05 -- -- Normal condition with USB load 0.5A
5 240V 50 0.087 8.71 -- -- Normal condition with USB load 0.5A
6 240V 60 0.087 8.72 -- -- Normal condition with USB load 0.5A
7 264V 50 0.081 8.73 -- -- Normal condition with USB load 0.5A
8 264V 60 0.081 8.72 -- -- Normal condition with USB load 0.5A

Loudspeaker impedance (Ω) .................................. : No speaker N


Several loudspeaker systems ................................. : -- --
Marking of loudspeaker terminals ........................... : -- --
Temperature Rise Dt of Part Dt (K) Limit max Dt (K)
Test Condition No. No _1_, No _2_, 264V/50Hz
90V/60Hz
AC wire 4.4 6.0 40
Internal wire 9.1 12.1 40
AC connector (CN901) 13.0 17.1 45
RT901 16.9 28.3 For reference
E-cap. (C910) 17.2 25.2 65
LF902 winding 20.1 28.1 80
LF902 core 19.0 26.4 80
E-cap. (C911) 27.1 34.7 65
PCB near U901 37.9 47.1 90
Opto coupler (U902) 16.2 19.8 60
Y1-cap. (CY902) 29.1 33.2 45
T901 core 29.0 32.0 70
T901 winding 34.8 38.2 70
PCB near D917 25.8 28.0 90
PCB near D912 16.1 24.4 90
U406 46.0 47.2 90
Metal enclosure outside 8.8 10.1 35
Front plastic enclosure 5.0 6.2 10
Button 3.0 3.8 55
o o
Ambient 23.2 C 23.7 C --
Winding temperature rise measurements
Ambient temperature t1 (oC) ....................... : -- -- —
o
Ambient temperature t2 ( C) ....................... : -- -- —
- Page 26 of 53 - Report No.: TRS12020074

Temperature rise dT of winding: R1 (Ω) R2 (Ω) dT (K) Limit max (K) Insulation class
dT = (R2 – R1) x (234.5 + t1) – (t2 – t1)
R1
-- -- -- -- -- --
-- -- -- -- -- --

7.2 TABLE: softening temperature of thermoplastics N

Temperature T of part T - normal condi- T - fault condi- Min. T softening


tions (oC) tions (oC) (oC)
-- -- -- --

supplementary information

9.1.1.1 Touch current expressed as voltages U1 and U2 in Annex D P

Location Measured U1 Measured Measured U2 Limits :


V (peak) U1 V (peak) U1 Max 35V (peak)
V (DC) U1 Max 1.0V (DC)
U2 Max 0.35V (peak)
Mains to metal enclosure 0.89 -- 0.24
Mains to output terminals 0.91 -- 0.25
Mains to front plastic enclosure 0.09 -- 0.06
supplementary information

10.3 TABLE: insulation resistance measurements P

Insulation resistance R between: R (MΩ) Required R (MΩ)


Between mains poles (primary fuse disconnected) >100 Min 2
Between parts separated by basic or supplementary insulation >100 Min 2
Between parts separated by double or reinforced insulation >100 Min 4

10.3 TABLE: electric strength measurements P

Test voltage applied between: Test voltage (V) Breakdown


Mains poles (primary fuse disconnected) 1500Vac No
Between parts separated by basic or supplementary insulation 3000Vac No
Between parts separated by double or reinforced insulation 3000Vac No

11.2 TABLE: summary of fault condition tests P


Voltage (V) 0,9 or 1,1 times rated voltage ..............: 264V —
Frequency (Hz) ........................................................: 60Hz
- Page 27 of 53 - Report No.: TRS12020074

Ambient temperature (oC) .......................................: 25.0 —


No. Component Fault dT (K) / Component Other results
(include description and test duration)
1 Ventilation blocked 28.3K/LF901 Input power no any change. The max.
winding. Temperature rise see front table. No damage,
47.8K/ PCB near no hazards.
U901.
Test duration: 1h23mins.
38.7K/T901 winding.
32.2K/T901 core.
27.6K/ PCB near
D917.
24.3K/ PCB near
D912.
10.2K/ Metal
enclosure outside.
5.7K/ Front plastic
enclosure.
23.1 oC/ Ambient.
2 USB port s-c -- USB port no output voltage, the input power
reduce to 7.43W/0.07A. Recoverable, no
damage no hazards.
Test duration: 10mins.
3 D910 s-c -- Fuse F902 opened immediately. No hazards.
Test duration: 1s.
4 C910 s-c -- Fuse F902 opened immediately. No hazards.
Test duration: 1s.
5 U901 Pin 3-4 s-c -- Fuse F902 open immediately. No hazards.
Test duration: 1s.
6 U901 Pin 1-4 s-c -- Fuse F902 open immediately and D918
damage. No hazards.
Test duration: 1s.
7 U902 Pin 3-4 s-c -- Unit shut down immediately. Recoverable. No
damage, no hazards.
Test duration: 10mins.
8 U902 Pin 1-2 s-c -- Unit shut down immediately. And the input
power bouncing between 0.11W and 6.24W,
when remove the fault the USB port no output
voltage. No hazards.
Test duration: 10mins.
9 T1 Pin 1-3 s-c -- Unit shut down immediately. Recoverable. No
damage, no hazards.
Test duration: 10mins.
10 T1 Pin 7-8,9 s-c -- Unit shut down immediately. Recoverable. No
damage, no hazards.
Test duration: 10mins.
11 D917 s-c -- Unit shut down immediately. Recoverable. No
damage, no hazards.
Test duration: 10mins.
- Page 28 of 53 - Report No.: TRS12020074

No. Component Fault dT (K) / Component Other results


(include description and test duration)
12 C916 s-c -- Unit shut down immediately. Recoverable. No
damage, no hazards.
Test duration: 10mins.
13 5V - GND s-c -- Unit shut down immediately. Recoverable. No
damage, no hazards.
Test duration: 10mins.
supplementary information:
s-c=short circuit, o-c=open circuit, o-l=overload
After each fault condition, dielectric strength test is conducted between mains poles and output terminals at
3000Vac, No breakdown after test.
Winding temperature rise measurements N
o
Ambient temperature t1 ( C) .................................. : -- —
o
Ambient temperature t2 ( C) .................................. : -- —

13 TABLES: clearances and creepage distances P


Rated supply voltage: 100-240V Pollution degree...: PD2 Material Group ....: IIIa, IIIb
2 N force on internal parts applied: CY902, CE172, CE310 P
30 N force on outside of conductive enclosure applied: Metal enclosure P
Location Working Voltage Clearance (mm) Creepage (mm)
V rms V peak Min Actual Min Actual
Across mains fuse F_902_ (B) 250 354 2.0 2.6 2.5 >2.6
Across primary directly connected to the 250 354 2.0 4.6 2.5 4.6
mains (B)
Opto coupler input to output (R) 250 354 4.0 7.0 5.0 7.0
Primary to Secondary under CY902 (R) 250 354 4.0 7.6 5.0 7.6
Primary to Secondary under transformer 259 484 4.2 7.6 5.4 7.6
T901 (R)
Primary (trace of D912) to secondary 250 354 4.0 7.7 5.0 7.7
Primary (trace of CY902) to secondary 250 354 4.0 7.1 5.0 7.1
Primary component (LF901) to secondary 250 354 4.0 7.9 5.0 7.9
Primary to accessible conductive parts (Top 250 354 4.0 >8 5.0 >8
enclosure) (R)
Primary to accessible conductive parts 250 354 4.0 --# 5.0 --#
(Bottom enclosure) (R)
Circuits conductively connected to the mains (use Tables 8, 9 and 11): see note below.
- Page 29 of 53 - Report No.: TRS12020074

Location Working Voltage Clearance (mm) Creepage (mm)


V rms V peak Min Actual Min Actual
Notes:
1. Secondary circuits of Class II apparatus which have connector terminals that could be earthed (e.g.
antenna signal input), are subjected to the requirements for circuits conductively connected to the mains in
Tables 8 and 9.
2. For insufficient clearances and creepage distances from secondary to secondary circuits see Cl. 4.3.1,
4.3.2 and 11.2.
3. If the minimum creepage distance in Table 11 is less than the minimum required clearance in Tables 8, 9
or 10 as required, then the value for clearance is used as the minimum creepage distance.
"Min" = minimum required.
"Actual = Actual dimensions measured.
4, # stands for insulation sheet on bottom enclosure used as reinforced insulation.

14 TABLE: list of critical components and materials P


Component Manufacturer/ Type/model Value / rating Standard Approval/
trademark Reference
Power plug Xinya Electronic XYP-201 250Vac, 2.5A EN 50075:1990 VDE 40007409
Co., Ltd.
(Alternative) Shenzhen Linoya XYP-01 250Vac, 2.5A EN 50075:1990 VDE 40014956
Electronic Co. Ltd.
(Alternative) Hunan Aomeng AM-008 250Vac, 2.5A EN 50075:1990 VDE 40015046
Electricity
Equipment Co.
Ltd.

(Alternative) Dong Guang X4206 250Vac, 2.5A EN 50075:1990 VDE 132431


Xiang De Li
Electronics Co.,
Ltd.

(Alternative) Sichuan Jiuzhou JZ2P-A 250Vac, 2.5A EN 50075:1990 VDE 40030013


wire and cable
Co., Ltd
(Alternative) Shenxhen XK-01 250Vac, 2.5A EN 50075:1990 VDE 40009009
Xiekang Electric
Co., Ltd.

(alternative) Various Various 250Vac, 2.5A, EN 50075:1990 VDE or TUV or


2Pins BSI

Power cord Hunan Aomeng H03VVH2-F 2X0.5mm2 IEC/EN 60227 VDE 134644
Electrical
Equipment Co. 2X0.75mm2
Ltd.

(Alternative) Xinya Electronic H03VVH2-F 2X0.5mm2 IEC/EN 60227 VDE 40000965


Co., Ltd.
2X0.75mm2
- Page 30 of 53 - Report No.: TRS12020074

(Alternative) Shenzhen Bao H03VVH2-F 2X0.5mm2 IEC/EN 60227 VDE 131689


Hing Electric Wire
& Cable 2X0.75mm2
Manufacture Co.
Ltd.

(Alternative) Sichuan Jiuzhou H03VVH2-F 2X0.75mm2 EN 60227 VDE 40028521


wire and cable
Co., Ltd

(Alternative) Shenzhen H03VVH2-F 2X0.5mm2 IEC/EN 60227 VDE 40029225


Xiekang Electric
Co., Ltd. 2X0.75mm2

SR Various Various Min.V-2 UL 94 UL


Panel material Fomosa AG15E1 HB, 60°C, UL 94 UL E162823
chemicals &fibre 1.6mm
corp. Plastics div
Alternative Fomosa GP5250 HB, 50°C, UL 94 UL E162823
chemicals &fibre 1.5mm
corp. Plastics div
Internal wire Various Various 80°C, 300V, UL 758 UL
VW-1, Min.
26AWG
Heat- Shenzhen Woer RSFR-H, RSFR 125°C, 600V, UL 224 UL E203950
shrinkable Heat-shrinkable VW-1
tube Material Co., Ltd.
(Alternative) Various Various 125°C, 600V, UL 224 UL
VW-1
AC connector ZHE JIANG DELI 3.96-3A 250Vac, 5A, UL 1977 UL E217379
(CN902) CONNECTORS 85°C
CO LTD
NTC Various Various NTC 10ohm -- --
(RT901)
Fuse (F902) Shzhen Lanson 3K T1A250V T1A, 250Vac IEC/EN60127-1 VDE 40010682
Electronics Co., IEC/EN60127-2
Ltd.
(Alternative) XC Electronics 3T-series T1A, 250Vac IEC/EN60127-1 VDE 40019614
(Shenzhen) Corp. IEC/EN60127-2
Ltd.
(Alternative) XC Electronics 5TE T1A, 250Vac IEC/EN60127-1 VDE 40029550
(Shenzhen) Corp. IEC/EN60127-2
Ltd.
Inductance DA WANG UU 9.8 Min. 38mH -- Test with
(LF902) ELECTRONICS appliance
INDUSTRY CO.,
LTD
Inductance CHANG CHUN T375J PHENOLICS UL 94 UL E59481
(LF902)- PLASTICS CO., 150°C
Bobbin LTD
- Page 31 of 53 - Report No.: TRS12020074

Inductance HOI LUEN UEW 130°C UL 1446 UL E164409


(LF902)- ELECTRICAL
winding MFR CO., LTD
Inductance HANG CHEUNG 8562(a) 155°C UL 1446 UL E200154
(LF902)- PETROCHEMICA
Varnish L LTD
Bridge Diode -- -- Min.1A, min. -- --
(D910,D911, 600V
D912, D913)
Electric -- -- Max. 10μF, min. -- --
capacitor 400V , 105°C
(C910)
Electric -- -- Max. 15μF, min. -- --
capacitor 400V , 105°C
(C911)
Opto coupler COSMO K1010 Dti=0.5mm, EN 60747-5-2 VDE 101347
(U902) ELECTRONICS Int. cr=5.3mm,
CORPORATION Ext. cr=8mm

(Alternative) Lite-On LTV-817 Dti=0.8mm, EN 60747-5-2 VDE 40015248


Technology Int. cr=5.2mm,
Corporation Ext. cr=7.8mm

(Alternative) Fairchild H11A817 Dti=0.7mm, EN 60747-5-2 VDE 40026857


Semiconductor Int. cr=5.2mm,
Ext. cr=7.8mm

(Alternative) Everlight EL817V Dti=0.5mm, EN 60747-5-2 VDE 132249


Electronics Co., Int. cr=6.0mm,
Ltd. Ext. cr=7.5mm

Y1-Capacitor Jyh Chung JD AC 250V IEC 60384-14: VDE 40016598


(CY902) Electronic Co.,
Ltd. 1000pF, 2005
subclass: Y1
125°C
(Alternative) Shantou High- CD-Series AC 400V IEC 60384-14: VDE 40025754
New Technology
Dev. Zone 1000 pF, 2005
Songtian subclass: Y1
Enterprise Co., 125°C
Ltd.

(Alternative) Tai Shan City JB-Series AC 400V IEC 60384-14: VDE 40014269
Juhong
Electronics Ltd. 1000pF, 2005
subclass: Y1
85°C
(Alternative) Guangdong South F AC 250V IEC 60384-14: VDE 118357
Hongming
Electronic Science 1000pF, 2005
and Technology subclass: Y1
Co., Ltd. 85°C
- Page 32 of 53 - Report No.: TRS12020074

Transformer Bo Luo Da Xin DTT1609. REV1 Class B -- Test with


(T901) appliance
Electronic Co.,
Ltd.
- Bobbin CHANG CHUN T375J PHENOLICS, UL 94 UL E59481
PLASTICS CO., 150°C
LTD
-Tripple E&B Tecgbology 130°C IEC/EN 60950-1 VDE 40023473
insulation wire Co Ltd. E&B-B-XXX

- Magnet HUIZHOU UEW 130°C UL 1446 UL E225143


GOLDEN OCEAN
Wire
MAGNET WIRE
FACTORY
(Alternative) HOI LUEN UEW 130°C UL 1446 UL E164409
ELECTRICAL
MFR CO LTD
- Insulation JINGJIANG CT 130°C UL 510 UL E165111
tape YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
- Margin tape JINGJIANG WF 130°C UL 510 UL E165111
YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
- Teflon tube Shenzhen Woer WF 600V, 200°C UL 224 UL E203950
Heat-shrinkable
Material Co., Ltd.
Transformer Huizhou Kaide DTT1609. REV1 Class B -- Test with
(T901) Technology Co., appliance
(Alternative) Ltd.
- Bobbin CHANG CHUN T375J PHENOLICS, UL 94 UL E59481
PLASTICS CO., 150°C
LTD
Alternative SUMITOMO PM-9820 PHENOLICS, UL 94 UL E41429
BAKELITE CO 150°C
LTD
-Tripple FURUKAWA TEX-E 130°C IEC/EN 60950-1 VDE 006735
insulation wire ELECTRIC CO
LTD
- Magnet TAI-I ELECTRIC UEW 130°C UL 1446 UL E85640
WIRE & CABLE
Wire
CO LTD
- Insulation JINGJIANG JY-133* 130°C UL 510 UL E309872
tape JINGYANG
INSULATING
PRODUCT CO
LTD
- Page 33 of 53 - Report No.: TRS12020074

- Margin tape JINGJIANG WF 130°C UL 510 UL E165111


YAHUA
PRESSURE
SENSITIVE
GLUE CO LTD
- Teflon CHANGYUAN CB-TT-S 600V, 200°C UL 224 UL E180908
tube ELECTRONICS
(SHENZHEN) CO
LTD
PCB Various Various 130°C, V-0 UL 94, UL 796 UL
Insulation MIANYANG PC-870, PC- Thickness: UL 94, UL 746 UL E254551
sheet in LONGHUA FILM 870-83(B) 0.4mm, V-0
bottom CO LTD
enclosure
(Alternative) CHENGDU KLX FRPC-870B Thickness: UL 94, UL 746 UL E315185
KANGLONGXIN 0.4mm, V-0
PLASTICS CO
LTD
1
) an asterisk indicates a mark which assures the agreed level of surveillance
Supplementary information

14.3.3 Transformer/motor, constructional requirements P

Loc. Tested insulation Working voltage Insulatio Required Required distance


n Res. electric
strength
peak / V rms / V M kV (60 s) clearan creepage distance
Ohms ce / mm distance / thr. insul.
mm
1 Reinforce: Primary - 484 259 4 3000 4.2 5.4 *
Secondary
2 Basic: Secondary - Core 484 259 4 3000 4.2 5.4 *
Loc. Tested insulation Measur Tested Measured distance
ed electric
Insulatio strength
n Res.
M kV (60 s) clearan creepage distance
Ohms ce / mm distance / thr. insul.
mm
1 Reinforce: Primary - Secondary 100 3000 5.8 5.8 3layers
2 Basic: Secondary - Core 100 3000 4.4 >5.4 3layers
supplementary information:
Note:
1, * 2 or 3 layers / 0.4mm / Annex H
2, See table 13.3&13.4 for details.
3, Secondary winding used triple insulation wire.
- Page 34 of 53 - Report No.: TRS12020074

14.11 TABLE: Opto Electronic Devices P


Distance
Bridging
Manufacturer Type External Internal Through
insulation
creepage creepage insulation
COSMO K1010
ELECTRONICS 8.0 5.3 0.5 Reinforced
CORPORATION
Lite-On Technology LTV-817
7.8 5.2 0.8 Reinforced
Corporation
Fairchild Semiconductor H11A817 7.8 5.2 0.7 Reinforced
Everlight Electronics El817V
7.5 6.0 0.5 Reinforced
Co., Ltd.
supplementary information

17.1 Torque test to Table 20: P

Screw Diameter With Without Material Torque test (Nm)


Location / function (mm) Head Head Screw Nut Fulfilled / Remarks
Metal Enclosure 2.5 Yes - Metal - Tested with 0.5Nm, 5 times
/Pass
supplementary information
- Page 35 of 53 - Report No.: TRS11120116
EN 60065
Clause Requirement - Test Result - Remark Verdict

ZB ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS N


2.6.1 DK: certain types of Class I apparatus, see 15.1.1, Class II apparatus N
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
13.3.1 NO: In Norway, due to IT power distribution system N
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
15.1.1 DK: mains cord for single-phase equipment having N
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
DK: Class I equipment with socket-outlets with N
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
DK: socket-outlets for providing power to Class II N
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 179
of EN 60 065:2002 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
DK: mains socket-outlets with earthing contact N
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
GB: equipment fitted with a flexible cable or cord N
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
IE: equipment fitted with a flexible cable or cord N
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the N
following amendments:
- dimensions 2,5 A, 250 V socket-outlets shall No socket-outlets. N
comply with Standard Sheet I page 180 of
EN 60 065:2002
- mechanical strength 2,5 A, 250 V socket-outlets N
tested as specified in EN 60 065, 12.1.3
- protecting rim also tested N
NO: method b) of 8.1 is not permitted. Double or No TNV circuits N
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
- Page 36 of 53 - Report No.: TRS11120116
EN 60065
Clause Requirement - Test Result - Remark Verdict

J.2 NO: In Norway, due to IT power distribution system N


used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.

ZC ANNEX ZC TO EN 60 065, A-DEVIATIONS N


5 DE: additional markings required in German language: N
- cathode ray tubes with an accelerating voltage No CRT used. N
between 20 kV and 30 kV (marking on the tube)
- TV receivers whose picture tube has an N
accelerating voltage between 20 kV and 30 kV
- TV receivers whose picture tube has an N
accelerating voltage greater than 30 kV
- TV receivers whose picture tube has an N
accelerating voltage less than 20 kV
5.1 IT: additional markings on the outside of the TV N
receiver in Italian language
IT: user instructions in Italian language including a N
conformity declaration
IT: certification number on the back cover N
14 SE: Switches containing mercury such as N
thermostats, relays and level controllers are not
allowed.
- Page 37 of 53 - Report No.: TRS12020074

Attachment 1
Circuit Diagram
- Page 38 of 53 - Report No.: TRS12020074

Attachment 2
PCB layout
- Page 39 of 53 - Report No.: TRS12020074
- Page 40 of 53 - Report No.: TRS12020074
- Page 41 of 53 - Report No.: TRS12020074

Attachment 3
Transformer Specification
- Page 42 of 53 - Report No.: TRS12020074
- Page 43 of 53 - Report No.: TRS12020074

Attachment 4
Photos of Product

Photo 1
View:
Model: SRT8505

[ √ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB

Photo 2
View:
Model: SRT8505

[ √ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB
- Page 44 of 53 - Report No.: TRS12020074

Photo 3
View:
Model: SRT8500

[ √ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB

Photo 4
View:
Model: SRT8500

[ √ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB
- Page 45 of 53 - Report No.: TRS12020074

Photo 5
View:
Model: SRT8520

[ √ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB

Photo 6
View:
Model: SRT8520

[ √ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB
- Page 46 of 53 - Report No.: TRS12020074

Photo 7
View:
Model: SRT8505

[ ] General

[ √ ] Front

[ ] Rear

[ √ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB

Photo 8
View:
Model: SRT8505

[ ] General

[ ] Front

[ √ ] Rear

[ √ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB
- Page 47 of 53 - Report No.: TRS12020074

Photo 9
View:
Model: SRT8500

[ ] General

[ √ ] Front

[ ] Rear

[ √ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB

Photo 10
View:
Model: SRT8500

[ ] General

[ ] Front

[ √ ] Rear

[ √ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB
- Page 48 of 53 - Report No.: TRS12020074

Photo 11
View:
Model: SRT8520

[ ] General

[ √ ] Front

[ ] Rear

[ √ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB

Photo 12
View:
Model: SRT8520

[ ] General

[ ] Front

[ √ ] Rear

[ √ ] Side

[ ] Internal

[ ] Transformer

[ ] PCB
- Page 49 of 53 - Report No.: TRS12020074

Photo 13
View:
Model: SRT8505,

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ √ ] Internal

[ ] Transformer

[ ] PCB

Photo 14
View:
Model: SRT8500,
SRT8520

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ √ ] Internal

[ ] Transformer

[ ] PCB
- Page 50 of 53 - Report No.: TRS12020074

Photo 15
View:
Model: SRT8505

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ √ ] PCB

Photo 16
View:
Model: SRT8505

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ √ ] PCB
- Page 51 of 53 - Report No.: TRS12020074

Photo 17
View:
Model: SRT8500,
SRT8520

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ √ ] PCB

Photo 18
View:
Model: SRT8500,
SRT8520

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ ] Transformer

[ √ ] PCB
- Page 52 of 53 - Report No.: TRS12020074

Photo 19
View:

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[√ ] Transformer

[ ] PCB

Photo 20
View:

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ √ ] Transformer

[ ] PCB
- Page 53 of 53 - Report No.: TRS12020074

Photo 21
View:

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ √ ] Transformer

[ ] PCB

Photo 22
View:

[ ] General

[ ] Front

[ ] Rear

[ ] Side

[ ] Internal

[ √ ] Transformer

[ ] PCB

------ End of Report ------