Bonding KS-DB GKA KPB GARG44C-RB BURNDY® Mechanical Grounding


The KS-DB SERVIT is a range The GKA is a range-taking termi- The KPB is a range-taking termi- The GAR644C-RB is a high
taking connector for joining a tap
to a run conductor. It is
approved for direct burial and
nal designed for joining smaller
conductors to a flat surface such
nal designed for joining smaller
conductors to a flat surface in a
perpendicular configuration.
copper alloy mechanical connec-
tor for grounding and bonding
copper conductor to ground rod,
Quick Reference Guide
includes a UL identification tag
as a pad or enclosure.
IPS pipe and concrete reinforce-
Application/Users
for inspection purposes. ment bar, in either parallel or If you would like to contact one of the users noted in this section, please call our
right angle position. Marketing Department at 1-800-346-4175 and we’ll put you in touch.

2
Telecommunications Mass Transit
The booming wireless industry is With the modernization and elec-
a perfect candidate for the trification of the nation’s railroads
4 Mechanical Grounding system. underway and the unstable cost of
With experts predicting that oil, Burndy Mechanical Grounding is
CL50-1 wireless base stations will dot proud to be playing a role in the
the landscape at the rate of one revitalization of this industry.
The copper Lay-in Lug is
every six miles, Mechanical
designed for grounding or bond-
Grounding offers the only
ing copper conductor to steel grounding system that installs
frame or other metal surfaces Utilities
quickly and easily, regardless of the
where a continuous run is Much success can be attributed to the
weather. “Traditional” phone
preferable. many utility companies that have
companies have been Mechanical
installed the system for a number
Grounding users for many years.
1 of applications. While grounding is
important in any industry, the utility
Architectural and Construction industry is especially susceptible
to fault currents and may have the
Engineers
most at risk in terms of the services it
Consultant engineering firms — provides to the public.
the specifiers — appreciate the
YGS benefits of having a sound, proven
The YGS is an in-line splice grounding system that’s easy to Pool/Spa Bonding
specifically designed for NEC install. “Tis the season, at least for swimming
and other code ground applica-
tions. This terminal features an pools, and FCI is the place to go for
inspection hole to ensure proper Army Corps of Engineers reliable, code-compliant pool/spa
cable insertion. bonding solutions. As you may be
While the Army Corps of Engineers
has not adopted one central standard aware, FCI offers a complete pool/spa
for grounding, Mechanical Grounding bonding system that is NEC compliant
7 FCI is the place to go for reliable, code-compliant swimming pool and spa bonding solutions. FCI has been included in several major and that has been tested under
Burndy Products offers a complete pool and spa package that is NEC (National Electric Code), projects of the Armed Forces. grounding and bonding standard
8 section 680-22 compliant and has been tested under Grounding and Bonding standard UL467. UL467.

9 National Electric Code Standards


National Electric Code Section 680-22 describes bonding and bonding requirements for swimming
YGA
pools. Section 680-22(b) requires that a bonding grid be created using the structural reinforcing steel
The YGA is a compression termi-
nal designed for NEC and other
of a concrete pool where the reinforcing rods are bonded together by the usual steel tie wires or the
code ground applications. This equivalent; or the walls of a bolted or welded metal pool, or a solid, copper conductor, insulated,
terminal features an inspection covered, or bare, not small than #8. Additional, a #8 solid or larger copper conductor must be used to
connect bonded parts to the grid. Section 250-113 states that connections to the common bonding 47 East Industrial Park Drive, Manchester, NH 03108
hole to ensure proper cable
insertion. grid must be made by exothermic, listed clamps, listed pressure connectors, or other means. In the U.S. call: 1-800-346-4175
Section 680-22(a) states that a reliable electrical connection must be made between all conductive International: 1-603-647-5000
surfaces within five (5) feet horizontally of the inside pool walls. Bonding, therefore, covers the drain,
Ontario, Atlantic & Western Canada:
rebar, water inlet pipe, skimmer, ladder, slides, diving structure, underwater lighting, junction boxes
6
(if within 5 feet) and/or water circulating/heating equipment. 1-800-361-6975
Quebec & Eastern Ontario:
1-800-361-6975
YGC
The YGC "C" Tap CRIMPIT is
manufactured from 99.9% pure
wrought copper and incorpo-
www.fciconnect.com BURNDY® Products
rates a "massive design copper
extrusion" for minimum connec-
tion resistance. BURNDY® Products www.fciconnect.com
BURNDY® Products BURNDY® Products Sample BURNDY®® Mechanical Grounding Connector Applications

Ground Cable Cable


Rods/ & Tray
GRC GRL
Rebar GAR The GRC High Strength Ground GP GK Braid GX GG KS-DB Braid GC-CT
The GAR is a Fence Post Rod Clamp and The GRL Ground The GP is a range-taking ground The GK connector is a ground The GX is for cross connecting The GG is for joining braid, bar, The KS-DB SERVIT is a range- Flexible copper braid is designed The GC-CT Cable Tray Ground
Grounding Connector. It is a Rod Clamp are range-taking connector for joining two parallel connector for joining three equal a wide range of copper cable. strap, or cable to a rod or tube. taking connector for joining a for applications requiring inten- Clamp is a tin-plated copper
range-taking ground connector ground connectors for joining a cables to a rod, pipe or column in cables to a rod or tube in a tap to a run conducor. It is tional movement, to take up linear connector that joins one or two
for joining cable to rod or tube in single copper cable to a copper, a perpendicular configuration. parallel configuration. Acceptable aproved for direct burial and expansion and contraction, com- copper or aluminum conduc-
parallel or right angle configura- copper clad steel, galvanized for direct burial in earth or includes a UL identification tag pensate for misalignment and tors to a cable tray.
tions. steel, or stainless steel ground concrete. for inspection purposes. absorb vibration of electrical
rod. equipment and devices.

Static Rail/ Transformer


Ground H-Beam
GIE-G GRF GP-G1 GA-H J & RGC EQC KC QGFL
The GIE-G is a temporary clamp for grounding gasoline trucks, tank The GRF is range-taking and is Our GP-G1 is range taking and is The GA-H is a range-taking con- The RGC connectors are tin plat- The EQC is an eye-in-basket, The KC SERVIT POST is used to The QGFL bar tap is an eye-in-
cars, aircraft and other vehicles where the danger of igniting designed for joining one or two designed for joining 1 or 2 conductors nector for foining a single cable ed mechanical clamp connec- range taking connector that fits ground one or two cables to steel basket connector for joining a
combustibles due to static electricity discharg exists. This connector conductors to a round or square to a round or square pedestal in all to an “H” beam or square tube tors. Unlike the RGC Series, the J all standard EEI and NEMA dis- structure, fence post, and trans- single cable to a bus bar or pad.
is designed to penetrate thin coats of paint and light corrosion to pedestal in all raised flooring raised flooring systems. This unique, in a parallel configuration. Series requires a terminal in it’s tribution transformers as a formers. They can also be used to B1 and B2 versions are available
make electrical contact. systems. patented connector is designed to installation. tank ground terminal. tap 1 or 2 cables from a drilled to differentiate stud size options.
penetrate painted pedestals to and tapped bus bar.
establish electrical contact.

Bus Bar/
Flat Bar

KC GB GBM GC GCM GL GZ QGFL GKA KPB CL50-1


The KC SERVIT POST is used to The GB is a range-taking con- The GBM type connector clamps The GC is a range-taking con- The GL is a range-taking connector The GZ is a range-taking connector The QGFL bar tap is an eye-in- The GKA is a range-taking The KPB is a range-taking termi- The Copper Lay-in Lug is
The GCM type connector clamps for joining 2 parallel cables to a 1/4” for joining a single cable to a 1/4” terminal designed for joining nal designed for joining smaller designed for grounding or bond-
The Mechanical Grounding line is a family of direct burial, UL listed connectors. Made of high copper
ground one or two cables to nector used for joining a single the cable directly onto the bus nector for joining two parallel the cables directly onto the bus basket connector for joining a
thick bus bar. This connector can also thick bus bar.The cable is griped by smaller conductors to a flat conductors to a flat surface in a ing copper conductor to steel content alloys, they use a nut and bolt design to provide the means for connecting copper cable to
steel structure, fence post, and conductor to 1/4” thick bus bar. bars surface. cables to a 1/4” thick bus bar. It’s bar surface. be used to tap a conductor off a con- single cable to a bus bar or pad.
transformers. They can also be It’s two piece design separates two piece design separates the curving it around the clamping bolt B1 and B2 versions are available surface such as a pad or enclo- perpendicular configuration. frame or other metal surfaces many applications. Only the finest high copper alloys are used to ensure performance under the most
tinuous run. The 2-piece design sep- in the connector groove when a sure. The GKA can be com- where a continuous run is
used to tap 1 or 2 cables from the cable from the bus bar. cable s from the bus bar. arates the cables from the bus bar. 2 to differentiate stud size options.
higher mechanical holding strength pletely installed with the use of preferable. extreme environmental conditions. Where the direct burial symbol appears, that connector is capable
a drilled and tapped bus bolts provide higher clamping force
on the conductors. is needed. a standard screwdriver. of direct burial applications in earth or embedment in concrete.
bar.

Over 75 years of technological innovations make FCI/BURNDY Mechanical Grounding Connectors


one of the most widely used, specified and highly respected lines in the industry. There are virtually no
Fence grounding or bonding application problems that our products cannot solve. All FCI/BURNDY
Mechanical Grounding Connectors are designed for easy installation and outstanding durability.
Post, GC-A GAR3902-BU GAR3902
Piping &
GP GK GD Low Cost Water Pipe Clamps GQ KC GAR GAR3902 Series GAR-TC GG
Tubing The GP is range-taking ground The GK connector is a ground con- The GD is a range-taking Low cost water pipe connectors are used for connecting grounding conduc-
tor to water pipe or copper tube. The cast bronze ground clamps come with
The GQ is a range-taking ground The KC SERVIT POST is used to The GAR is a Fence Post The GAR3902 Series is designed to connect one conductor to a rod, The GAR-TC features a pre- The GG is for joining braid, bar,
connector for joining two paral- nector for joining three equal connector for joining two cables connector for connecting a cable ground one or two cables to steel Grounding Connector. It is a pipe, tube or rebar in a perpendicular or parallel configuration. This drilled pad allowing a 2-hole strap, or cable to a rod or tube.
either silicon bronze hardware or brass hardware. Clamps with silicon structure, fence post, and trans- range-taking ground connector The Direct Burial Symbol indicates that the connector is suitable for burial in
lel cables to a rod, pipe or cables to a rod or tube in a paral- to a rod or pipe in a parallel to a large diameter pipe. series is supplied with plated steel hardware. The difference between compression terminal to be con- Earth or concrete.
column in a perpendicular lel configuration. Acceptable for configuration. bronze hardware are UL467 listed for direct burial in earth or concrete. formers. They can also be used to for joining cable to rod or tube in nected to water pipe as well as
this series and our standard GAR connector is the rotating element in
There is also a line of cast bronze clamps for use with conduit. These are tap 1 or 2 cables from a drilled parallel or right angle configura-
configuration. direct burial in earth or concrete. the 3902 series tat allows for perpendicular configurations. The columns and other cylindrical The Underwriters Laboratories symbol indicates that the connector meets the
used for grounding rigid conduit systems and come with zinc and tapped bus bar. tions. noted UL standard.
GAR3902 series with a BU suffix are supplied with DURIUM silicon shapes. The terminal may be
plated hardware.
bronze hardware, making them acceptable for direct burial in earth or paralled, 45° or 90° to the pipe.
GC-A The CSA symbol indicates that the connector meets the applicable standards
The GC-A dual rated ground clamps are used for copper and aluminum
concrete.
of the Canadian Standards Association.
cable. GC-A ground clamps are UL listed for attaching either copper or
aluminum conductors to copper water pipe, galvanized pipe or steel conduit.

You might also like