You are on page 1of 2

/STRUCTURES/STANDARDIZATION/STEELWORK NOTES

STEELWORK NOTES – INLAND.

1. DIMENSIONS ARE TO BE CHECKED ON SITE AND ANY DISCREPANCIES MUST BE BROUGHT


TO THE ATTENTION OF THE ENGINEER BEFORE WORK IS COMMENCED.

2. STEELWORK TO BE FABRICATED AND ERECTED IN ACCORDANCE WITH SPECIFICATIONS


SANS 2001-CS1 AND SANS 1921-3.

3. HOT-ROLLED STEEL SECTIONS EXCEPT ANGLES SMALLER THAN 90x90 TO BE GRADE 350W
TO SANS 1431. HOT-ROLLED PLATES AND ANGLES SMALLER THAN 90x90 TO BE
GRADE 300W TO SANS 1431.

4. CORROSION PROTECTION OF STEELWORK:


4.1 ALL BOLTS, NUTS AND WASHERS, INCLUDING HOLDING DOWN BOLTS, TO BE HOT DIP
GALVANIZED TO SANS 121 (ISO 1461), TABLE 3. NUTS WITH OVERSIZE THREADS ARE TO
BE USED TO COMPENSATE FOR THE GALVANIZING ON THE BOLT THREADS.
4.2 ALL THE STEELWORK TO BE HOT DIP GALVANIZED TO SANS 121 (ISO 1461).

5. FABRICATORS TO SUBMIT TWO COPIES OF ALL SHOP DRAWINGS TO THE STRUCTURAL


ENGINEER FOR APPROVAL PRIOR TO FABRICATION.

6. GROUT TO BE A CEMENTITIOUS, SELF-LEVELLING, NON- SHRINK GROUT.

STEELWORK NOTES – PORTS.

1. DIMENSIONS ARE TO BE CHECKED ON SITE AND ANY DISCREPANCIES MUST BE


BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE WORK IS COMMENCED.

2. STEELWORK TO BE FABRICATED AND ERECTED IN ACCORDANCE WITH SPECIFICATIONS


SANS 2001-CS1 AND SANS 1921-3.

3. HOT-ROLLED STEEL SECTIONS EXCEPT ANGLES SMALLER THAN 90x90 TO BE GRADE 350W
TO SANS 1431. HOT-ROLLED PLATES AND ANGLES SMALLER THAN 90x90 TO BE
GRADE 300W TO SANS 1431.

4. CORROSION PROTECTION OF STEELWORK:


4.1 ALL BOLTS, NUTS AND WASHERS, INCLUDING HOLDING DOWN BOLTS, TO BE HOT DIP
GALVANIZED TO SANS 121 (ISO 1461), TABLE 3. NUTS WITH OVERSIZE THREADS ARE TO
BE USED TO COMPENSATE FOR THE GALVANIZING ON THE BOLT THREADS.
4.2 ALL THE STEELWORK TO BE HEAVY DUTY HOT DIP GALVANIZED TO SANS 121
(ISO 1461). THE COATING THICKNESS TO BE 25% GREATER THAN THE STANDARD IN
TABLE 2, IN ACCORDANCE WITH SABS SPECIFIC PERMIT CONDITIONS 1336/2494.
4.3 ALL STEELWORK INCLUDING BOLTS, NUTS AND WASHERS, TO BE PAINTED TO
PORTNET'S SPECIFICATION HE9/2/8 (VERSION 16) AFTER GALVANIZING.

5. FABRICATORS TO SUBMIT TWO COPIES OF ALL SHOP DRAWINGS TO THE STRUCTURAL


ENGINEER FOR APPROVAL PRIOR TO FABRICATION.
6. GROUT TO BE A CEMENTITIOUS, SELF-LEVELLING, NON- SHRINK GROUT.

STEELWORK NOTES – COASTAL (NON PORT).

1. DIMENSIONS ARE TO BE CHECKED ON SITE AND ANY DISCREPANCIES MUST BE


BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE WORK IS COMMENCED.

2. STEELWORK TO BE FABRICATED AND ERECTED IN ACCORDANCE WITH SPECIFICATIONS


SANS 2001-CS1 AND SANS 1921-3.

3. HOT-ROLLED STEEL SECTIONS EXCEPT ANGLES SMALLER THAN 90x90 TO BE GRADE 350W
TO SANS 1431. HOT-ROLLED PLATES AND ANGLES SMALLER THAN 90x90 TO BE
GRADE 300W TO SANS 1431.

4. CORROSION PROTECTION OF STEELWORK:


4.1 ALL BOLTS, NUTS AND WASHERS, INCLUDING HOLDING DOWN BOLTS, TO BE HOT DIP
GALVANIZED TO SANS 121 (ISO 1461), TABLE 3. NUTS WITH OVERSIZE THREADS ARE TO
BE USED TO COMPENSATE FOR THE GALVANIZING ON THE BOLT THREADS.
4.2 ALL THE STEELWORK TO BE HEAVY DUTY HOT DIP GALVANIZED TO SANS 121
(ISO 1461). THE COATING THICKNESS TO BE 25% GREATER THAN THE STANDARD IN
TABLE 2, IN ACCORDANCE WITH SABS SPECIFIC PERMIT CONDITIONS 1336/2494.

5. FABRICATORS TO SUBMIT TWO COPIES OF ALL SHOP DRAWINGS TO THE STRUCTURAL


ENGINEER FOR APPROVAL PRIOR TO FABRICATION.

6. GROUT TO BE A CEMENTITIOUS, SELF-LEVELLING, NON- SHRINK GROUT.

You might also like