You are on page 1of 22

50Hz/60Hz INVERTER

LIGHT COMMERCIAL
AIR CONDITIONER

Guangdong Chigo Heating & Ventilation Equipment Co,.ltd.

Helangsha,Chigo industrial district,lishui,nanhai,foshan,


guangdong,china,P.C:528244

86-757-88781037

86-757-88789825

isc@chigo-cac.com

www.chigo-cac.com

Note
All the data in this catalogue maybe changed without notice for
further improvement on quality and performance.

V.RZQZ
About
Established in 2011,Guangdong Chigo Heating & Ventilation
Equipment Co,.Ltd. ( GCHV ) is a professional central air
conditioning equipment manufacture and supply enterprise
integrating R&D,testing,manufacturing, marketing,project
design,sales and after sales service.GCHV covers an area of
167,000 square meters,with more than 120,000 square meters
of plants and 14 modern first class production lines.

GCHV’s annual output of central air conditioners exceeds 2


million sets, which including VRF,modular chiller,light commercial
air conditioners,air source heat pumps and other products.
GCHV’s products are in great demand on 100 countries and
regions and has accomplished thousands of reference projects
worldwide,which enabled it become the top 3 central air
conditioner supplier in china.

Chigo commercial air Honored of“National high- Full DC inverter VRF Mechanical and Electrical GCHV starts operating
conditioning division established tech enterprises ” CMV-X series launched Installation Level 2 Qualification independently from Chigo Holding

2004 2012 2014 2017 2019

2002 2011 2013 2015 2018


Chigo enter central air Guangdong Chigo Heating & Ventilation New R&D office building and Honored of“Provincial engineering 2018 Russia World Cup HVAC Supplier
conditioning industry Equipment Co,.ltd. Established VRF plant put into operation research and development center ” Test center certificated by CNAS
Robotic
Assembly Arm

Production Capacity
Automatic
Packing Robot
GCHV has 14 advanced production lines and an
annual production capacity of over 1.5 million sets.

Introduce lean production management, improve


production efficiency. By the use of various robots ,
AGV system and other equipment, improving the
online, offline process, optimizing the logistics
AGV System
distribution technology, improving product quality
and production efficiency.Adopts MES(Manufacturing
Execution System) system, it helps a lot in tracking
production schedule, inventory status, work schedule
and other operations management to improve.
Product quality and productivity.

MES System

Quality Superiority Certification

ISO9001 quality management system, ISO14001 environmental management system,


Assembly OHSAS18001 occupational health and safety management system,QC080000 electronic
and electrical components and products harmful substances process management system
Key Components certification
Key Step Main product certificated by CCC, energy-saving certification, ETL, AHRI,DOE, CE, CB, SASO,
Control GCHV has established a strict and scientific
Assembly quality management system with supplier ESMA, MEW and others.
100% quality assurance,incoming quality control,
Pre-check process quality control and final quality
On-line control to ensure the highest quality of the
Testing products.

Quality The industry-leading testing center has been GB/T 19001

Management certified by CNAS in 2018, With a full range of


1% professional incoming inspection labs,enthalpy
Inspection difference labs , EMC labs, 27 national GB/T 24001
accreditedlabs for testing and verification.
1%
Quality Assurance Inspection
GB/T 19001 24001 ISO9001 ISO14001 OHSAS18001 QC080000

Finished Products
Enthalpy Difference Lab 01 How To Read The Model

R&D Directory
Strength 03
DC Inverter Mono LCAC
Universal Outdoor Unit
Laboratory Control Room

60Hz DC Inverter Mono


17 LCAC Universal Unit

200kg Transport Simulation Platform Professional Engineers EMC Lab

31 DC Inverter Multi Split Unit

36 Controllers
Noise Test Lab 200HP Long-term Running Lab Modular Chiller Test Lab

The R&D center of GCHV has more than 200 technical


engineers.And carry out technology collaboration and
joint research with postdoctoral research workstations
and Guangdong enterprise workstations,at the same
time, introducing senior technical experts from Japan Electromagnetic Vibration Lab
to join GCHV and served as senior technical consultants,
GCHV pay great attention in R&D and invest 4.5% of
annual income every year to develop new technology,
by continuous innovation,GCHV has established a solid
development foundation and strength in performance,
structure, electronic control, industrial design and other
professional aspects.

The test center covers an area of more than 6,000 square


meters. It has a series of industry-leading professional
laboratories. In 2010, it passed the consistency check
of the National Energy Efficiency Label Management
Center and obtained certificate,in 2018,the test center
obtained CNAS national certification .
DC Inverter Mono LCAC
12,
000 55,000 60,000

; R4:R32

D:Full DC Inv Compact


4 way cassette

(R32 Only) (R410a Only)

; R4:R32

(R32) (R410a) (R32/R410a)


Mono LCAC

COU-12HDR1 COU-18HDR1 COU-24HDR1 COU-36HDR1-A COU-36HZDR1 COU-48HZVR1 COU-60HZVR1


Outdoor power supply(V/N/HZ) 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 380~415/3/50 380~415/3/50 380~415/3/50
Performance
Btu/h 12000 18000 24000 36000 36000 48000 60000
Cooling Capacity
KW 1.4-3.5-3.8 2.0-5.3-5.6 3.5-7.0-8.0 6.6-10.5-12.8 6.6-10.5-12.8 7.15-14.0-15.6 7.8-16.0-17.5

Btu/h 11200 20000 26000 40000 40000 52000 60000


Heating Capacity
KW 1.6-3.3-4.1 3.0-5.9-6.0 4.5-7.7-8.5 7.35-11.5-13.2 7.35-11.5-13.2 8.0-15.2-17.2 8.5-17.6-19.5
Physical data
Compressor DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary DC/Twin-ratary DC/Twin-rotary AC/Twin-rotary AC/Twin-rotary
fan motor DC DC DC DC DC DC DC

Outdoor power level 62 63 67 68 68 70 70


dB(A)
12K 48K/55/60K Btu/h noise level pressure level 51 52 57 55 55 58 58
Dimension(W*H*D) mm 900x610x352 925×700×366 958×843×392 1050×995×347 1050×995×347 950×1335×388 950×1335×388
Outdoor unit Packing(W*H*D) mm 990×670×410 990×770×410 1025×960×430 1145×1120×475 1145×1120×475 964x1445x402 964x1445x402
Net/Gross weight kg 33.5/36.5 45/48 59/69 84/95.5 86.7/97.7 98.5/106.5 98.5/106.5
Refrigerant type/quantity g R410A/1200 R410A/1400 R410A/2200 R410A/3800 R410A/3800 R410A/4100 R410A/4100
Piping data
Energy saving and excellent efficiency,reaching
Liquid side/Gas side mm Φ6.35/Φ12.7 Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88
European A++ and A+ class energy label,meets the Refrigerant
EU’s new energy efficency requirement.Comply with piping Max. pipe length m 15(30) 15(30) 20(50) 50(65) 50(65) 50(65) 50(65)
ErP directive. Max. high drop m 8(20) 8(20) 10(25) 20(30) 20(30) 20(30) 20(30)
cooling °C -15~50 -15~50 -15~50 -15~50 -15~50 -15~50 -15~50
Ambient temp
heating °C -15~30 -15~30 -15~30 -15~30 -15~30 -15~30 -15~30

Wide outdoor operation range, the cooling operation


temperature is down to -15 degree.
R32 Heat Pump R32

COU-18HDR4 COU-24HDR4 COU-36HDR4 COU-36HZDR4 COU-48HDR4 COU-48HZDR4 COU-55HZDR4


Outdoor power supply(V/N/HZ) 220~240/1/50 220~240/1/50 220~240/1/50 380~415/3/50 220~240/1/50 380~415/3/50 380~415/3/50
Performance
Btu/h 18000 24000 36000 36000 48000 48000 55000
Cooling Capacity
-15
KW 2.0-5.3-5.6 3.5-7.0-8.0 6.6-10.5-12.8 6.6-10.5-12.8 7.0-14.0-15.5 7.0-14.0-15.5 7.5-16.0-17.0

Btu/h 2000 26000 40000 40000 52000 52000 60000


Heating Capacity
KW 3.0-5.9-6.0 4.5-7.7-8.5 7.35-11.5-13.2 7.35-11.5-13.2 8.0-15.2-16.0 8.0-15.2-16.0 8.5-16.8-17.5
New integrated PCB has big contribution to AC fast Physical data
reply and simple service. Fin type heat sink gives PCB a Compressor DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary
cool working condition(Single phase ODU). fan motor DC DC DC DC DC DC DC

Outdoor power level 63 67 68 68 70 70 70


dB(A)
noise level pressure level 52 54 55 55 58 58 58
Dimension(W*H*D) mm 925×700×366 958×843×392 1030×788×432 1030×788×432 1014×1430×450 1014×1430×450 1014×1430×450
Outdoor unit Packing(W*H*D) mm 990×770×410 1025×960×430 1120×900×485 1120×900×485 1095×1545×485 1095×1545×485 1095×1545×485
Net/Gross weight kg 42/45 52/62 68/74 75/81 109/123.6 109/123.6 112/126.6
Refrigerant type/quantity g R32/1300 R32/1700 R32/2150 R32/2150 R32/3800 R32/3800 R32/3800
New electric control box material change from metal to Piping data
plastic, not only reduce the weight, but also avoid the short Liquid side/Gas side mm Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88
Refrigerant
circuit cause by the PCB touch the metal box(Single phase Max. pipe length m 15(30) 20(50) 50(65) 50(65) 50(65) 50(65) 50(65)
piping
ODU).
Max. high drop m 8(20) 10(25) 20(30) 20(30) 20(30) 20(30) 20(30)
cooling °C -15~50 -15~50 -15~50 -15~50 -15~50 -15~50 -15~50
Ambient temp
heating °C -15~30 -15~30 -15~30 -15~30 -15~30 -15~30 -15~30
Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
R410a Heat Pump 4-way Cassette R410a

B CCA-60HVR1

V/N/Hz

60,000

6.1 6.1

18K~60K Btu/h

29.5 29.5

35 35

R32 Heat Pump Round flow Cassette R32

CCR-18HVR4 CCR-24HVR4 CCR-36HVR4 CCR-36HVR4S CCR-48HVR4 CCR-48HVR4S CCR-55HVR4S


Outdoor power supply(V/N/HZ) 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50
Performance
Cooling Capacity kW 2.0-5.3-5.6 3.5-7.0-8.0 6.6-10.5-12.8 6.6-10.5-12.8 7.0-14.0-15.5 7.15-14.0-15.6 7.5-16.0-17.0
EER W/W 3.35 3.27 3.33 3.33 2.83 2.83 2.71
SEER W/W 6.1 6.1 6.1 6.1 6.1 6.1 6.1
Heating Capacity kW 2.5-5.9-6.0 4.5-7.7-8.5 7.35-11.5-13.2 7.35-11.5-13.2 8.0-15.2-16.0 8.0-15.2-16.0 8.5-16.8-17.5
COP W/W 4.01 4.01 3.41 3.41 3.09 3.09 3.08
SCOP W/W 4.0 4.0 4.0 4.0 4.0 4.0 4.0
Cooling energy rate A++ A++ A++ A++ A++ A++ A++
Heating energy rate A+ A+ A+ A+ A+ A+ A+
Indoor airflow(Hi/Lo/Med) m3/h 900/800/650 1100/1000/850 1800/1700/1550 1800/1700/1550 2000/1800/1600 2000/1800/1600 2000/1900/1700
Physical data
Power noise level dB(A) 46~58 56~63 53~61 53~61 54~62 54~62 54~62
Pressure noise level dB(A) 36/41/45 43/46/49 43/45/48 43/45/48 45~52 45~52 45~52
Body mm 840×230×840 840×230×840 840×285×840 840×285×840 840×285×840 840×285×840 840×285×840
Net dimension(W*H*D)
Panel mm 950×50×950 950×50×950 950×50×950 950×50×950 950×50×950 950×50×950 950×50×950
Body mm 920×265×920 920×265×920 920×310×920 920×310×920 920×310×920 920×310×920 920×310×920
Packing(W*H*D)
Panel mm 1030×105×1030 1030×105×1030 1030×105×1030 1030×105×1030 1030×105×1030 1030×105×1030 1030×105×1030
Body mm 25/30 25/30 30.5/36 30.5/36 32/37.5 32/37.5 32/37.5
Panel Net/Gross weight
Panel kg 6.5/9.5 6.5/9.5 6.5/9.5 6.5/9.5 6.5/9.5 6.5/9.5 6.5/9.5
Piping data
Diameter Liquid side/Gas side mm Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88
Drain pipe mm DN25 DN25 DN25 DN25 DN25 DN25 DN25
Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
R410a&R32 Heat Pump R32

CCB-12HVR1 CCB-18HVR1 CCB-18HVR4

V/N/Hz 220~240/1/50 220~240/1/50 220~240/1/50

Btu/h 12000 18000 18000


Capacity
kW 1.4-3.5-3.8 2.0-5.3-5.6 2.0-5.3-5.6
Cooling EER 3.3 3.33 3.41
SEER 6.1 6.1 6.1
Energy class A++ A++ A++
Btu/h 11200 20000 20000
Capacity 1.6-3.3-4.1 3.0-5.6-6.0 2.5-5.9-6.0
kW
Heating COP 3.5 4.12 4.08
SCOP 4 4.0 4.0
Energy class A+ A+ A+
Physical data
Air flow(high speed) m³/h 560 650 650
power level 44-52 46-55 46-55
Noise level dB(A)
pressure level 32/36/40 36/39/43 36/39/43
Body(mm) 565x267x565 565x267x565 565x267x565
Net(W*H*D)
Panel(mm) 650x29.8x650 650x29.8x650 650x29.8x650
Indoor unit Body(mm) 745x375x675 745x375x675 745x375x675
Packing(W*H*D)
Panel(mm) 750x95x750 750x95x750 750x95x750
Body(kg) 16.5/21.5 16.5/21.5 16.5/21.5
Net/Gross weight
Panel(kg) 2.7/4.0 2.7/4.0 2.7/4.0
Piping data
Liquid side mm Φ6.35 Φ6.35 Φ6.35
Pipes Gas side mm Φ12.7 Φ12.7 Φ12.7
Drain pipe mm DN25 DN25 DN25
Refrigerant R410a R410a R32
Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
CUA-60HVR1

V/N/Hz

60,000

1.59(0.42-2.1)
6.1 6.1 5.1
3.33

5.6(2.5-6.0)
1.36(0.5-1.94)
18K~60K Btu/h
4.12 3.72

R32 Heat Pump R32

CUA-18HVR4 CUA-24HVR4 CUA-36HVR4 CUA-36HVR4S CUA-48HVR4 CUA-48HVR4S CUA-55HVR4S


Outdoor power supply(V/N/HZ) 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50
Performance
Cooling Capacity kW 2.0-5.3-5.6 3.5-7.0-8.0 6.6-10.5-12.8 6.6-10.5-12.8 7.0-14.0-15.5 7.0-14.0-15.5 7.5-16.0-17.0
EER W/W 3.23 3.18 3.31 3.31 2.8 2.8 2.69
DC motor is standard(Except for R410 48K/55K units), SEER W/W 6.1 6.1 6.1 6.1 6.1 6.1 6.1
operating stably and precisely control for temperature. Heating Capacity kW 2.5-5.9-6.0 4.5-7.7-8.5 7.35-11.5-13.2 7.35-11.5-13.2 8.0-15.2-16.0 8.0-15.2-16.0 8.5-16.8-17.5
COP W/W 3.86 3.89 3.39 3.39 3.06 3.06 2.90
SCOP W/W 4.0 4.0 4.0 4.0 4.0 4.0 4.0
Cooling energy rate A++ A++ A++ A++ A++ A++ A++
Heating energy rate A+ A+ A+ A+ A+ A+ A+
Indoor airflow(Hi/Lo/Med) m3/h 900/800/650 1150/1000/850 1800/1650/1500 1800/1650/1500 2000/1700/1600 2000/1700/1600 2000/1700/1600
Physical data
Power noise level dB(A) 46~58 53~60 56~65 56~65 58~66 58~66 58~66
Pressure noise level dB(A) 36~47 43~49 45~51 45~51 45~52 45~52 46~52
Net dimension(W*H*D) 1245×680×240 1245×680×240 1245×680×240 1245×680×240 1670×680×245 1670×680×245 1670×680×245

Packing(W*H*D) 1325×770×325 1325×770×325 1325×770×325 1325×770×325 1750×780×335 1750×780×335 1750×780×335

Panel Net/Gross weight 34/40 35/41 35/41 35/41 49/56 49/56 49/56
Piping data
Diameter Liquid side/Gas side mm Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88
Drain pipe mm DN25 DN25 DN25 DN25 DN25 DN25 DN25

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
R410a&R32 Heat Pump R32

CTA-12HVR1 CTA-18HVR1 CTA-18HVR4 CTA-24HVR1 CTA-24HVR4


V/N/Hz 220~240V/1/50 220~240V/1/50 220~240V/1/50 220~240V/1/50 220~240V/1/50

12000
3.5(1.4-3.8)
6.1 6.1 6.1 6.1 6.1
3.33 3.26 3.26
A++ A++ A++ A++ A++
11200
3.3(1.6-4.1) 5.9(2.5-6.0) 7.7(4.5-8.5)
4.0 4.0 4.0 4.0 4.0
3.5 4.12 4.0 3.72 3.3
A+ A+ A+ A+ A+

600 920 1030


0-30 30(0-60) 0-30 30(0-100)
42-52
31-40
814x210x467 1214X210X467 1214X210X467 1214X210X467 1214X210X467
16
Short body,1214mm length,easy to install,low noise
910x240x510 1310X240X510 1310X240X510 1310X240X510 1310X240X510
and light weight,suitable for hotel room.
19

Φ6.35
Φ12.7
DN25
Refrigerant R410a R410a R32 R410a R32
Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
121 2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
4m 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
m 4.The above data may be changed without notice for future improvement on quality and performance.
*: We suggest that for 18K&24K units, external static pressure is lower than 30Pa. If higher static pressure is needed, please contact with supplier.
CTB-60HVR1

V/N/Hz

60,000

3.10(1.2-4.25)
4.0
36K~60K Btu/h
A+

50Pa ESP design for medium static pressure duct ,


duct connected installation meet for different room
structure (can be customized to 70Pa ESP).For R32
51 51
medium duct type, the static pressurecan be high to
120Pa.

R32 Heat Pump R32

CTB-36HVR4 CTB-36HVR4S CTB-48HVR4 CTB-48HVR4S CTB-55HVR4S


Outdoor power supply(V/N/HZ) 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50
World famous brand DC motor is standard(Optional Performance
for R410 48K/55K units),save energy and control the Cooling Capacity kW 6.6-10.5-12.8 6.6-10.5-12.8 7.0-14.0-15.5 7.0-14.0-15.5 7.5-16.0-17.0
room temperature more prercisely. EER W/W 3.21 3.21 2.8 2.8 2.7
SEER W/W 6.1 6.1 6.1 6.1 6.1
Heating Capacity kW 7.35-11.5-13.2 7.35-11.5-13.2 8.0-15.2-16.0 8.0-15.2-16.0 8.5-16.8-17.5
COP W/W 3.3 3.3 3.0 3.0 3.0
SCOP W/W 4.0 4.0 4.0 4.0 4.0
Cooling energy rate A++ A++ A++ A++ A++
Heating energy rate A+ A+ A+ A+ A+
Indoor airflow(Hi/Lo/Med) m3/h 1900/1690/1130 1800/1500/1200 2500/2350/1980 2500/2350/1980 2500/2350/1980
Physical data
Rated power noise level dB(A) 55~63 55~63 56~64 56~64 56~64
Static pressure range Pa 0-120 0-120 0-160 0-160 0-160
Net dimension(W*H*D) 1425×260×643 1425×260×643 1279×307×830 1279×307×830 1279×307×830

Packing(W*H*D) 1490×325×720 1490×325×720 1395×380×920 1395×380×920 1395×380×920

Panel Net/Gross weight 46/50 46/50 49/56 49/56 49/56


Piping data
Diameter Liquid side/Gas side mm Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88
Drain pipe mm DN25 DN25 DN25 DN25 DN25

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
*: We suggest that for 36K units, external static pressure is lower than 80Pa and for 48K&55K units, external static pressure is lower than 120Pa. If higher static pressure is needed,
please contact with supplier.
CTH-60HVR1
V/N/Hz

60,000

48K~60K Btu/h

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

(Can be customized to 150Pa ESP)


Mono LCAC

60Hz R410a Heat Pump


Outdoor unit COU-12HNVR1-C COU-18HNVR1-C COU-24HNVR1-C COU-36HNVR1-C COU-48HNVR1-C COU-60HNVR1-C COU-60HXVR1-C

Power supply V/N/Hz 208~230/1/60 208~230/1/60 208~230/1/60 208~230/1/60 208~230/1/60 208~230/1/60 208~230/3/60

Btu/h 12000 18000 24000 36000 48000 60000 60000


Cooling capacity kW 3.5 5.3 7.0 10.5 14.0 16.0 16.0
Btu/h 12000 18000 24000 36000 48000 60000 60000
Heating capacity
kW 3.5 5.3 7.0 10.5 14.0 16.0 16.0

Compressor DC/Rotary DC/Rotary DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary DC/Twin-rotary


Outdoor noise level dB(A) ≤51 ≤53 ≤54 ≤58 ≤58 ≤58 ≤58
Net(W×H×D) mm 843×304×540 843×304×540 890×352×609 970×370×770 970×370×770 911×400×1330 911×400×1330
Outdoor unit Packing(W×H×D) mm 920×335×585 920×335×585 990×410×660 1100×470×880 1100×470×880 964×402×1445 964×402×1445
Net/Gross weight kg 25.9/28.2 29.5/31.8 36.1/39.4 69.0/74.0 69.0/74.0 98.5/106.5 98.5/106.5
12K 48K/60K Btu/h Refrigerant type/quantity g R410a/920 R410a/1150 R410a/1600 R410a/2500 R410a/3000 R410a/3600 R410a/3600
Liquid/Gas side mm Φ6.35/Φ12.7 Φ6.35/Φ12.7 Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88
Refrigerant
Max.pipe length m 25 25 25 30 50 50 50
piping
Max.high drop m 10 15 15 20 25 25 25
Cooling ℃ -15~50 -15~50 -15~50 -15~50 -15~50 -15~50 -15~50
Ambient temp.
Heating ℃ -15~30 -15~30 -15~30 -15~30 -15~30 -15~30 -15~30

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
60Hz R410a Heat Pump
Indoor unit CCA-18HNVR1-C CCA-24HNVR1-C CCA-36HNVR1-C CCA-48HNVR1-C CCA-60HNVR1-C CCA-60HNVR1S-C

Power supply V/N/Hz 208~230/1/60 220~240/1/60 208~230/1/60 208~230/1/60 208~230/1/60 208~230/1/60


Capacity kW 5.3 7 10.5 14 16 16
Cooling EER W/W 2.4 2.3 2.6 2.5 2.3 2.3
Capacity kW 5.3 7 10.5 14 16 16
Heating
COP W/W 2.6 2.6 3.4 2.8 2.7 2.7

Indoor air flow m3/h 1250 1250 1600 1900 1900 1900
Indoor noise level dB(A) ≤58 ≤63 ≤63 ≤65 ≤65 ≤65
Body(mm) 840×230×840 840×230×840 840×285×840 840×285×840 840×285×840 840×285×840
Net(W×H×D)
Panel(mm) 950×50×950 950×50×950 950×50×950 950×50×950 950×50×950 950×50×950
18K~60K Btu/h Packing(W×H×D)
Body(mm) 920×265×920 920×265×920 920×310×920 920×310×920 920×310×920 920×310×920
Indoor unit
Panel(mm) 1030×105×1030 1030×105×1030 1030×105×1030 1030×105×1030 1030×105×1030 1030×105×1030
Body(kg) 25/30 25/30 27/32 29.5/35 29.5/35 29.5/35
Net/Gross weight
Panel(kg) 5.4/8.0 5.4/8.0 5.4/8.0 5.4/8.0 5.4/8.0 5.4/8.0
Refrigerant liquid/gas piping mm Φ6.35/Φ12.7 Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88
Drainage pipe mm DN25 DN25 DN25 DN25 DN25 DN25

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
60Hz R410a Heat Pump
CCB-12HNVR1-C CCB-18HNVR1-C

V/N/Hz 208~230/1/60 208~230/1/60

Capacity kW 3.5 5.3


Input kW 1.15 1.8
Rated current A 5 8
Cooling
EER W/W 2.40 2.40
Capacity kW 3.5 5.3
Heating Input kW 0.88 1.65
Rated current A 4 7.5
COP W/W 3.20 2.60
Physical data
Indoor air flow(high speed) m3/h 560 650
Indoor noise level dB(A) ≤52 ≤55
Body(mm) 580×260×580 580×260×580
Net(W*H*D)
Panel(mm) 650×30×650 650×30×650
Body(mm) 745×375×675 745×375×675
Indoor unit Packing(W*H*D)
Panel(mm) 750×95×750 750×95×750
Body(kg) 16.5/21.5 16.5/21.5
Net/Gross weight
Panel(kg) 2.7/4.0 2.7/4.0
Piping data
Refrigerant Liquid/Gas side piping mm Φ6.35/Φ12.7 Φ6.35/Φ12.7
Drainage pipe mm DN25 DN25

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

21/22
60Hz R410a Heat Pump
CUA-18HNVR1-C CUA-24HNVR1-C CUA-36HNVR1-C CUA-48HNVR1-C CUA-60HNVR1-C CUA-60HNVR1S-C

V/N/Hz 208~230/1/60 208~230/1/60 208~230/1/60 208~230/1/60 208~230/1/60 208~230/1/60

Capacity kW 5.3 7.0 10.5 14.0 16.0 16.0

EER W/W 2.4 2.3 2.6 2.5 2.3 2.3

Capacity kW 5.3 7.0 10.5 14.0 16.0 16.0


Heating
COP W/W 2.6 2.6 3.4 2.8 2.7 2.7

Indoor air flow(high speed) m3/h 700 900 1300 2000 2000 2000

Indoor noise level dB(A) ≤58 ≤60 ≤60 ≤65 ≤65 ≤65

Dimension(W×H×D) mm 1245×680×247 1245×680×247 1245×680×247 1670×680×247 1670×680×247 1670×680×247


18K~60K Btu/h
Packing(W×H×D) mm 1325×770×325 1325×770×325 1325×770×325 1750×770×325 1750×770×325 1750×770×325

Net/Gross weight kg 34/40 34/40 36/42 49/55.5 49/55.5 49/55.5

Refrigerant liquid/gas side mm Φ6.35/Φ12.7 Φ6.35/Φ12.7 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88 Φ9.52/Φ15.88

Drainage pipe mm DN25 DN25 DN25 DN25 DN25 DN25

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

V/N/Hz

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

23/24
60Hz R410a Heat Pump
CTA-12HNVR1-C CTA-18HNVR1-C CTA-24HNVR1-C
V/N/Hz 208~230V/1/60 208~230V/1/60 208~230V/1/60

Capacity kW 3.5 5.3 7.0

Input kW 1.15 1.8 2.45


Cooling
Rated current A 5.2 8.2 11.1

EER W/W 2.80 2.74 2.70

Capacity kW 3.5 5.3 7.0

Input kW 0.88 1.65 2.05


Heating
Rated current A 4 7.5 8.5

COP W/W 3.20 2.60 2.60

Physical data

Indoor air flow(high speed) m3/h 620 750 800

Indoor noise level dB(A) ≤37 ≤58 ≤63


Net(W×H×D) mm 814×210×467 1010×210×467 1214×210×467
Short body,1214mm length,easy to install,low noise Indoor unit Packing(W×H×D) mm 910×240×510 1310×240×510 1310×240×510
and light weight,suitable for hotel room.
Net/Gross weight kg 14/17 21/24 25/28

Piping data

Refrigerant liquid/gas side pipe mm Ф6.35/Ф12.7 Ф6.35/Ф12.7 Ф6.35/Ф12.7

Drainage pipe mm DN25 DN25 DN25

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
121 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4m 4.The above data may be changed without notice for future improvement on quality and performance.
m

25/26
Medium ESP Ducted Unit
60Hz R410a Heat Pump
CTB-36HVR1-C CTB-48HVR1-C CTB-60HVR1-C
V/N/Hz 208~230V/1/60 208~230V/1/60 208~230V/1/60

Capacity kW 10.5 14.0 16.0

Input kW 3.4 4.5 6.5


Cooling
Rated current A 15.5 20.5 12.5

EER W/W 2.73 2.70 2.30

Capacity kW 10.5 14.0 16.0

Input kW 2.8 4.0 5.5


Heating
Rated current A 12.5 17.5 12.0

COP W/W 3.40 2.80 2.70

Physical data

Indoor air flow(high speed) m3/h 1150 2000 2000

Indoor noise level dB(A) ≤63 ≤65 ≤65


Net(W×H×D) mm 1170×260×643 1425×260×643 1425×260×643
50Pa ESP design for medium static pressure duct , Indoor unit Packing(W×H×D) mm 1255×325×720 1490×325×720 1490×325×720
duct connected installation meet for different room
structure (can be customized to 70Pa ESP).For R32 Net/Gross weight kg 33/37 45/51 45/51
medium duct type, the static pressurecan be high to Piping data
120Pa.
Refrigerant liquid/gas side pipe mm Ф9.52/Ф15.88 Ф9.52/Ф15.88 Ф9.52/Ф15.88

Drainage pipe mm DN25 DN25 DN25

World famous brand DC motor is standard(Optional V/N/Hz


for R410 48K/55K units),save energy and control the
room temperature more prercisely.

Notes:
1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.

27/28
48K~60K Btu/h 36/48/60k Btu/h

(Can be customized to 150Pa ESP)

Model CAH-36CNVR1 CAH-48CNVR1 CAH-60CNVR1


CTH-60HVR1S-C
V/N/Hz 208~230/1/60 208~230/1/60 208~230/1/60
V/N/Hz 208~230V/1/60
Capacity Btu/h 36000 48000 60000
Capacity W 10500 14068 16000
Capacity kW 16.0 253 470 470
Cooling Indoor Input W
EER W/W 2.3 Indoor Rated current A 1.16 2.14 2.14

Capacity kW 16.0
Heating Indoor air flow 1700 2500 2200
COP W/W 2.70
ESP Pa 37 50 50
Physical data Indoor noise level dB(A) 51~56 51~57 51~57
Unit (WxHxD) mm 460×774×520 500×970×550 500×970×550
Indoor air flow(high speed) m3/h 2300 Indoor dimension
Packing (WxHxD) mm 520×834×565 560×1030×595
Indoor noise level dB(A) ≤66
Net kg 37 45 45
Indoor weight
Net(W×H×D) mm 1175×370×625 Gross kg 39 48 48
Operation temperature range ℃ 16-32 16-32 16-32
Indoor unit Packing(W×H×D) mm 1245×445×655
Operation Control Wired controller
Net/Gross weight kg 47/51
Notes:
Piping data 1.The cooling condition: T1 condition: indoor side 27℃ (80.6℉) DB, 19℃ (60℉) WB, outdoor side 35℃ (95℉) DB;
2.The heating condition: indoor side 20℃ (68℉) DB, 15℃ (44.6℉) WB, outdoor side 7℃ (42.8℉) DB
Refrigerant liquid/gas side pipe mm Ф9.52/Ф15.88 3.Sound level: measured at a point 1m in front of the unit at a height of 1.3m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
4.The above data may be changed without notice for future improvement on quality and performance.
Drainage pipe mm DN25

29/30
V/N/Hz ~ ~ 220~240/1/50

77.7/89.1 82.6/94 84.5/95.9

R32 Multi Split Outdoor Unit R32

C2OU-14HDR4-A C2OU-18HDR4-A C3OU-21HDR4-A C3OU-27HDR4-A C4OU-28HDR4-A C4OU-36HDR4-A C5OU-42HDR4-A


7+7+7+7 9+9+9+9 9+9+9+9+9
7+7+7 9+9+9 12+12+9 12+12+12+9
7+7 9+9 12+12+12
7+9+9 12+9+9 18+12 18+12+12
7+9 9+12 18+18
18+7 18+9 24+7 24+18
R410a Units 24+12
V/N/Hz 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

7000-14000 7000-18000 7000-21000 7000-27000 7000-28000 7000-36000 7000-42000


R32 Units
52°C 1280 1650 1930 2472 2520 3400 3900
34°C 5.56 7.3 8.4 10.9 11.2 15.2 18.0
3.2 3.2 3.2 3.2 3.2 3.2 3.2
6.6 6.3 6.5 6.3 6.8 6.8 6.5
8000-16000 8000-20000 8000-24000 8000-30000 8000-30000 8000-38000 8000-44000
1350 1730 2150 2600 2450 3080 3650
6.4 7.97 10.8 10.8 11.2 15.2 18.0
3.5 3.4 3.4 3.4 3.63 3.6 3.55
4.0 4.0 4.0 4.0 4.0 4.0 4.0

54 54 55 55 59 61 62
944×608×345 944×608×345 989×843×392 989×843×392 1090×997×399 1090×997×399 1090×997×399
995×680×415 995×680×415 1025×960×430 1025×960×430 1145×1120×475 1145×1120×475 1145×1120×475
41/44 41/44 53.7/64.1 56.1/66.6 77.7/89.1 82.6/94 84.5/95.9

2×(6.35/9.52) 2×(6.35/9.52) 3×(6.35/9.52) 3×(6.35/9.52) 4×(6.35/9.52) 4×(6.35/9.52) 5×(6.35/9.52)


30 30 45 45 60 60 75
10 10 10 10 10 10 10
Ambient temperature(Cooling) -15~52 -15~52 -15~52 -15~52 -15~52 -15~52 -15~52
Ambient temperature(Cooling) -15~34 -15~34 -15~34 -15~34 -15~34 -15~34 -15~34
2×(10~15) 2×(12~18) 3×(12~18) 3×(12~18) 4×(10~15) 4×(12~18) 5×(12~18)

31/32
V/N/Hz V/N/Hz

R32 R32
R32 R32

CSC-07HVR4-A CSC-09HVR4-A CSC-12HVR4-A CSC-18HVR4-A


CSG-07HVR4-A CSG-09HVR4-A CSG-12HVR4-A CSG-18HVR4-A CSG-24HVR4-A
V/N/Hz 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50
V/N/Hz 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

7000 9000 12000 18000


7000 9000 12000 18000 24000
25 25 26 34
40 40 40 60 66
0.12 0.12 0.12 0.16
0.2 0.2 0.2 0.27 0.3
8000 10000 13000 19000
8000 10000 13000 19000 25000
25 25 26 34
40 40 40 60 66
0.12 0.12 0.12 0.16
0.2 0.2 0.2 0.27 0.3

540/490/410 540/490/410 690/610/520 790/710/610


400/350/320 500/400/320 550/400/330 750/580/500 1000/900/700
39/36/33 39/36/33 40/37/34 44/41/38
30/27/24 33/28/24 36/30/25 44/40/36 45/42/38
50 50 54 55
47 47 50 58 60
565×267×565 565×267×565 565×267×565 565×267×565
878×290×227 878×290×227 878×290×227 953×347×270 1180×362×288
745×375×675 745×375×675 745×375×675 745×375×675
950×365×300 950×365×300 950×365×300 1075×380×310 1235×390×330
16.5/21.5 16.5/21.5 16.5/21.5 16.5/21.5
8.5/11 8.5/11 8.5/11 10.5/13.5 13.5/16.5

6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7


6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7 9.52/15.88
DN25 DN25 DN25 DN25
DN20 DN20 DN20 DN20 DN20
10~15 12~18 16~23 23~34 34~51 10~15 12~18 16~23 23~34

33/34
V/N/Hz

R32 R32

CST-07HVR4-A CST-09HVR4-A CST-12HVR4-A CST-18HVR4-A


V/N/Hz 220~240/1/50 220~240/1/50 220~240/1/50 220~240/1/50

7000 9000 12000 18000


20 20 30 45
0.1 0.1 0.15 0.2
8000 10000 13000 19000
20 20 30 45
0.1 0.1 0.15 0.2

550/410/340 550/410/340 680/580/450 800/700/600


30/26/23 30/26/23 36/31/27 32/30/26
47 47 52 48
814×210×467 814×210×467 814×210×467 1010×210×467
910×240×510 910×240×510 910×240×510 1110×240×510
17/19.5 17/19.5 17/19.5 20.5/24

6.35/9.52 6.35/9.52 6.35/9.52 6.35/12.7


DN25 DN25 DN25 DN25
10~15 12~18 16~23 23~34