Overload switch manual (screen board function)

edition:U2.3.4

Load pin input connection(left one connector):

1. Exc +;

2. Exc -;

3. Sig +;

4. Sig -。

Screen board output connection(middle one connector)


Pin 1 and pin 4 are screen board 20mA digital current signal output, do not

distinguish positive and negative poles, it can automatic recognition and switch

Power and control cable:(right one connector)

[1] + [2] for the power input;

[5] + [6] for the output of relay 1;

[3] + [4] for the output of relay 2。

Weighing mode:
keep pressing the "check" key for 5 seconds, four digital display will

be zero, there is no range limitation on zero。

Calibration mode:

1) press "up" button and hold for 5 seconds, the digital display will

show: "SPAN", after 1 second it will show: "ZERO";

2) please make sure load cell on no load at that time, keep stable,

then press "check" button, confirm zero point. The display

show ”LOAD”, after 1 second, the display will show full capacity,

first digit flashing. Please load a weight on load pin, enter the

correct data at the same time, and keep it in stable.

3) A) Press the "UP" key, flashing digit increase 1 (to 9 back to 0)

B) Press the "DOWN" key, flashing digit decrease 1 (to 0 back to 9 )

C) Press the "check" key, flashing digit will move to left for one digit, till to

leftmost digit

D) Press the "set" key, flashing digit will move to right for one digit, till the

rightmost digit. If you forget to load the weight, or the weight is too small, the display

will show”ERR0”, if correct, it will show ”FULL”, please enter the rated capacity, if no

operate, after one second, default setting current weight as rated capacity. If not, please

enter your target rated capacity.

4) A) Press the "UP" key, flashing digit increase 1 (to 9 back to 0)


B) Press the "DOWN" key, flashing digit decrease 1 (to 0 back to 9 )

C) Press the "check" key, flashing digit will move to left for one digit, till to

leftmost digit

D)Press the "set" key, flashing digit will move to right for one digit, till the

rightmost digit. If rated capacity smaller than load weight, digital will show "ERR4", if

correct, it will show ”End”, then automatically switch to the normal weighing mode.

Division value: 1

If it is first calibration, or revise the rated capacity, 3 kinds of

parameter including Pre-alarm point weight, Delay alarm point weight

and Immediate alarm point weight should be re-set after calibration

complete. The default value as follow

Pre-alarm point weight = 90%×F.S.

Immediate alarm point weight = 110%×F.S.

Parameter setting mode 1:

1) press "Set" button and hold for 5 seconds, the digital display will

show: "SET", after 1 second it will show: "SET1";

2) 【per-alarm point setting】 After show "SET1" 1 second, digital

display show percentage of rated capacity as pre-alarm point, first

digit flashing:

A) Press the "UP" key, flashing digit increase 1 (to 9 back to 0)


B)Press the "DOWN" key, flashing digit decrease 1 (to 0 back to 9 )

C)Press the "check" key, flashing digit will move to left for one digit, till to leftmost digit

D)Press the "set" key, flashing digit will move to right for one digit, till the rightmost

digit. The display will show” SET2”, if the capacity of pre-alarm ≥ rated capacity, the

entered data will be invalid, press ”set” key, the display will show”ERR1”, please

enter the correct data again.

3) 【Immediate alarm point setting】After show "SET2" for 1 second,

digital display show percentage of rated capacity as immediate alarm

point, first digit flashing:

A)Press the "UP" key, flashing digit increase 1 (to 9 back to 0)

B)Press the "DOWN" key, flashing digit decrease 1 (to 0 back to 9 )

C)Press the "check" key, flashing digit will move to left for one digit, till to leftmost digit

D)Press the "set" key, flashing digit will move to right for one digit, till the rightmost

digit. The display will show “ dp-X”,

4) 【Decimal place digit setting,the default one is 2】This is the

number of decimal place digit setting, X can be the digit from 0 to 3

A) Press the "UP" key, flashing digit increase 1 (to 3 back to 0)

B) Press the "DOWN" key, flashing digit decrease 1 (from 3 to 0 )

C) Press the "set" key, flashing digit will move to right for one digit, till the

rightmost digit. The display will show” SET 3”


5)【rated capacity Coefficient setting,the default is 100】After show

"SET3" for 1 second, digital display show coefficient of rated capacity,

first digit flashing:

A) Press the "UP" key, flashing digit increase 1 (to 9 back to 0)

B) Press the "DOWN" key, flashing digit decrease 1 (to 9 back to 0 )

C) Press the "check" key, flashing digit will move to left for one digit, till to leftmost

digit

D) Press the "set" key, flashing digit will move to right for one digit, till the rightmost

digit. The display will show” SET4”,

Note 1: If the coefficient ( it mean the percentage of rated capacity)

bigger than 500 or less than 50, the data will be invalid. Press the "set"

key, the display will show”ERR2”, please re-enter the correct data.

6)
【MINI working point setting】After show "SET4" for 1 second, digital

display show percentage of rated capacity as mini working point, first

digit flashing:

A) Press the "UP" key, flashing digit increase 1 (to 9 back to 0)

B) Press the "DOWN" key, flashing digit decrease 1 (to 9 back to 0 )

C) Press the "check" key, flashing digit will move to left for one digit, till to leftmost

digit

D) Press the "set" key, flashing digit will move to right for one digit, till the rightmost

digit. The display will show” SET5”

6)
【Filter coefficient parameter setting】After show "SET5" for 1 second,
digital display filter coefficient parameter”F-XX”, XX range between

1-63,, first digit flashing:

A) Press the "UP" key, XX value increase 1 ( till to 63)

B) Press the "DOWN" key, XX value decrease 1 (till to 1 )

C) Press the "set" key, the display will show” PASS”, the setting is complete, then

automatically switch to the normal weighing test mode..

Parameter setting mode 2:

1) press "DOWN" button and hold for 5 seconds, the digital display will

show: "DL-X", start setting time delay parameter;

2) Press the "UP" key, flashing digit increase 1 (to 9 back to 1)

3) Press the "DOWN" key, flashing digit decrease 1 (to 9 back to 1 )

4) Press the "check" key, quit and not save parameter setting, back to weighing mode

5) Press the "set" key, save the parameter setting and the display will show” PASS”,

back to weighing mode

6) The default delay parameter is 5, the range are 1~9.

Screen board output:

Screen board output are 20mA digital current loop, 600bps speed rate, data

refresh and synchronization are same with display (up to 10 times /sec),

reliable transmission distance bigger than 300 meters.


Use and alarm:

1) When display on power, the buzzer will tweet one sound, and LED

lighting. After 1 second, show the edition of software U2.33, after

1.5 seconds, the display automatically switch to the normal

weighing mode.

2) When the load less Mini working point, contact of relay 2 are

disconnected, when the load bigger than Mini working point,

contact of relay 2 connect, and contact of the relay 1 always

connect before reach to alarm point

3) When the load reach to pre-alarm point, the buzzer will tweet 8

times in a row, then keep silence, then repeat the tweet and

silence again and again , the time of tweet and silence are same.

At the same time, the yellow alarm LED will lighting.

4) If keep increasing the load to beyond rated capacity (still not

reach to immediate alarm point), the buzzer will tweet 4 times in a

row, then keep silence, then repeat the tweet and silence again

and again , the time of tweet and silence are still same. the yellow

alarm LED will keep lighting

5) In weighing mode, the buzzer will tweet in a row and the red
alarm LED will lighting immediately once the load reach to

immediate alarm point. And at the same time, the relay 1 will

disconnect immediately.

Relay status

Relay 1: connect ( normal close), beyond the alarm point, it will disconnect

Relay 2: connect ( normal close), if less the mini working point, it will disconnect,

and once the load beyond the alarm point, it will connect too.

6) Logical relationship between alarm point

Pre-alarm point<rated capacity≤immediate alarm point

If violate this logical relationship, it will not be able to enter the next

step, and the setting will not be saved

ERR CODE:

Err0 :There is no weight on load or weight too small during actual weight

calibration during calibration model

Err1:Pre-alarm point≥rated capacity during alarm point setting


Err2:rated capacity Coefficient setting bigger than 500 or less

than 50

Err4:rated capacity less than actual weight during calibration;

Err5:load cell cable broken, please check.

Note:

1. The polarity of load cell cable has been modified, and with a view to

simplified operation, we add a function on display. Keep pressing any three

button at the same time after power on (before digital display flashing

stop), releasing buttons after show software version (U2.33), the display

will show:

It is mean inverse processing of ADC polarity have been done on the basis

setting. In future operation, you do not need change the load cell cable

anymore.

2. Filter coefficient parameter are used for adjust reaction speed of display,

setting range from 1 to 63, the bigger parameter, the reaction speed of

display is faster. But filter coefficient parameter too big, display can’t deal

with all disturbing factors, accuracy of result will be affected. Please choose

suitable parameter according to your need.