Overview insulation monitoring devices ISOMETER®

1
ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER®
iso685-… iso685-…-B iso685-…-P isoNAV685-D isoNAV685-D-B

Catalogue page 32 36 40 46 51
Quick response to combined De-energised loads/
Special applications resistance and offset voltage frequency converters
measurement
Control circuits
Circuits

Auxiliary circuits
Main circuits
3(N)AC
Voltage system

AC
AC/DC
DC

AC, 3(N)AC 0…690 V, AC, 3(N)AC 0…690 V, AC, 3(N)AC 0…690 V, AC, 3(N)AC 0…690 V
Nominal system voltage Un offline
DC 0…1000 V DC 0…1000 V DC 0…1000 V (60 Hz)

Tolerance of Un + 15 % + 15 % + 15 % + 15 %

System leakage capacitance Ce µF ≤ 1000 ≤ 1000 ≤ 1000 ≤ 1000 ≤ 1000

Response value Ran kΩ 1…10000 1…10000 1…10000 1…10000 10…1000

Coupled systems
Locating current injector
for insulation fault location
DIN rail
Installation

Screw mounting
Panel mounting/
wall fastening
Web server
Modbus TCP/RTU TCP/RTU TCP/RTU TCP TCP
Interfaces

BCOM
BS
BMS
isoData

Product details
(Products on
www.bender.de/en)

Type C. p. Suitable system components


FP200 65
AGH150W-4 324
Coupling devices

AGH204S-4 326
AGH520S 327

AGH675S-7 328
AGH676S-4 330

4 Insulation monitoring devices | Device overview 01/2020


1
ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER®
isoHR685W-…-B isoRW685W-D IRDH275 IRDH275BM-7 IRDH375 IRDH575

56 61 67 70 74 77

AC, DC or AC/DC Equipment for


Oil & Gas Railway medium voltage systems insulation fault location

AC 0…1000 V, AC, 3(N)AC 0…690 V, AC, 3(N)AC 0…690 V AC, 3(N)AC, DC AC, 3(N)AC 0…690 V
3AC 0…690 V, dependent on type
DC 0…1000 V DC 0…565 V 0…15,5 kV (absolute) DC 0…565 V
DC 0…1300 V

+ 15 % + 15 % + 15 % + 15 % + 15 % + 15 %

≤ 1000 ≤ 1000 ≤ 500 ≤5 ≤ 500 ≤ 500 (150)

1…3000000 1…10000 1…10000 100…10000 1…10000 1…10000

TCP TCP/RTU

Suitable system components

01/2020 Insulation monitoring devices | Device overview 5


Overview insulation monitoring devices ISOMETER®

1
ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER®
IR420-D4 IR425 iso1685P iso1685DP isoHV1685D

Catalogue page 16 19 22 25 25

Special applications

Control circuits
Circuits

Auxiliary circuits
Main circuits
3(N)AC
Voltage system

AC
AC/DC
DC

AC 0…1000 V, AC 0…1000 V, AC 0…2000 V,


Nominal system voltage Un AC 0…250 V AC/DC 0… 300 V DC 0…1500 V DC 0…1500 V DC 0…3000 V

+10 %, +10 %, +10 %,


Tolerance of Un + 20 % + 20 % +6 % +5% +5%
System leakage capacitance Ce µF ≤ 20 ≤ 20 ≤ 500 ≤ 2000 ≤ 2000

Response value Ran kΩ 1…200 1…200 200…1000 200…1000 200…1000

Coupled systems
Locating current injector
for insulation fault location
DIN rail
Installation

Screw mounting
Panel mounting/
wall fastening
Web server
Modbus RTU RTU
Interfaces

BCOM
BS
BMS
isoData

Product details
(Products on
www.bender.de/en)

Type C. p. Suitable system components


FP200 65
AGH150W-4 324
Coupling devices

AGH204S-4 326
AGH520S 327

AGH675S-7 328
AGH676S-4 330

6 Insulation monitoring devices | Device overview 01/2020


1
ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER®
isoLR1685DP isoHR1685DW IR1575 IR427 isoMED427P isoLR275

25 29 81 84 88 102
Installations with
insulated elevating Medical locations Medical locations a low level of
work platforms insulation

via AGH-LR
AC 0…690 V, AC 0…1000 V, AC, 3(N) AC 0…400 V AC 70…330 V AC 70…230 V 3(N)AC 0…690 V
DC 0…690 V DC 0…1500 V DC 0…400 V DC 0…1000 V
+10 % +10 %, + 15 %
+ 20 % + 15 % + 15 %
+5% +5% + 10 %
≤ 2000 ≤1 ≤ 60 ≤5 ≤5 ≤ 500

20…100 100…1000 2…1000 50…500 50…500 kΩ 0.2…100

RTU RTU

Suitable system components

01/2020 Insulation monitoring devices | Device overview 7


Overview insulation monitoring devices ISOMETER®

1
ISOMETER®
ISOMETER® ISOMETER® ISOMETER® ISOMETER®
isoPV1685RTU
isoPV isoPV425 IR420-D6 IR423
isoPV1685P

Catalogue page 91 95 99 105 108

Special applications Photovoltaic Photovoltaic Photovoltaic Disconnected loads Mobile generators

Control circuits
Circuits

Auxiliary circuits
Main circuits
3(N)AC
Voltage system

AC
AC/DC
DC
via AGH-PV DC 0…1000 V,
Nominal system voltage Un 3(N)AC 0…793 V DC 0…1500 V offline AC 0…250 V
AC 0…690 V , 15…460 Hz
DC 0…1000 V

Tolerance of Un + 10 % + 15 % +6% + 20 %

System leakage capacitance Ce µF ≤ 2000 ≤ 500 ≤ 2000 ≤ 10 ≤5

Response value Ran kΩ 0.2…100 1…990 0.2…990 100…10000 1…200

Coupled systems
Locating current injector
for insulation fault location
DIN rail
Installation

Screw mounting
Panel mounting/
wall fastening
Web server
Modbus RTU
Interfaces

BCOM
BS
BMS
isoData

Product details
(Products on
www.bender.de/en)

Type C. p. Suitable system components


FP200 65
AGH150W-4 324
Coupling devices

AGH204S-4 326
AGH520S 327

AGH675S-7 328
AGH676S-4 330

8 Insulation monitoring devices | Device overview 01/2020


1
ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER®
IR123 IR155 isoEV425 isoCHA425 iso165C isoRW425

111 114 118 122 125 128

Mobile generators Electric mobility Electric mobility Electric mobility Electric mobility Railway

DC 0…1000 V
AC 100…250 V DC 0…1000 V AC 0…690 V, DC 0…400 V DC 0…600 V AC/DC 0…400 V
15…460 Hz
+ 10 %
+ 20 % +0% + 15 % + 25 %
+ 15 %
≤1 ≤1 ≤5 ≤2 ≤1 ≤ 300
23 kΩ 30 kΩ…1 MΩ;
46/23 100…10000 10…990 1…990
46 kΩ 40 kΩ…2 MΩ

RTU RTU RTU

Suitable system components

01/2020 Insulation monitoring devices | Device overview 9


Overview insulation monitoring devices ISOMETER®

1
ISOMETER® ISOMETER® ISOMETER® ISOMETER® ISOMETER®
isoUG425 isoES425 isoGEN423 isoGEN523 isoHV425

Catalogue page 131 134 137 140 143

Energy storage Generators acc. to standard Generators acc. to standard


Special applications Unearthed DC systems VDE-AR-E 2510-2 DIN VDE 0100-551 DIN VDE 0100-551

Control circuits
Circuits

Auxiliary circuits
Main circuits
3(N)AC
Voltage system

AC
AC/DC
DC
with AGH422
3 (N)AC, AC 0…400 V, 3(N)AC, AC 0…400 V, 3(N)AC, AC 0…400 V,
Nominal system voltage Un DC 12…120 V AC 0…1000 V,
DC 0…400 V DC 0…400 V DC 0…400 V DC 0…1000 V

Tolerance of Un +20 % +25 % +25 % +25 % +10 %

System leakage capacitance Ce µF ≤ 50 ≤ 100 ≤5 ≤5 ≤ 150

Response value Ran kΩ 2…100 2…990 Ran2…200 Ran2…200 11…500

Coupled systems
Locating current injector
for insulation fault location
DIN rail
Installation

Screw mounting
Panel mounting/
wall fastening
Web server
Modbus RTU RTU RTU RTU
Interfaces

BCOM
BS
BMS
isoData

Product details
(Products on
www.bender.de/en)

Type C. p. Suitable system components


FP200 65
AGH150W-4 324
Coupling devices

AGH204S-4 326
AGH520S 327

AGH675S-7 328
AGH676S-4 330

10 Insulation monitoring devices | Device overview 01/2020


1
ISOMETER®
isoHV525

147

AC 0…1000 V,
DC 0…1000 V

+10 %

≤ 150

11…500

RTU

01/2020 Insulation monitoring devices | Device overview 11


Device overview Equipment for insulation fault location ISOSCAN®

ISOSCAN® ISOSCAN® ISOSCAN® ISOSCAN® ISOSCAN®


EDS440 EDS441 EDS441-LAB EDS460/490 EDS461/491

Catalogue page 154 154 154 161 161


High-resistance insulation
faults in case of high system
2 Special applications leakage capacitances and low
test current value
Application stationary stationary stationary stationary stationary
Control circuits
Circuits

Main circuits
3(N)AC
Voltage system

AC
AC/DC
DC

see Locating current injector AC 230 V, AC 230 V, see Locating current injector AC 230 V,
Nominal voltage Un max (e. g. ISOMETER® iso685-D-P) DC 220 V DC 220 V (e. g. ISOMETER® iso685-D-P) DC 220 V

System leakage capacitance Ce µF acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve
Response value Ran kΩ acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve
DIN rail
Installa-
tion

Screw mounting
BB EDS440-S EDS441-S
Interfaces

BS EDS440-L EDS441-L
BMS

Product details
(Products on
www.bender.de/en)

Type C. p. Suitable system components


iso685-D-P 40
Suitable ISOMETER®s
with integrated PGH

IRDH575 77
isoMED427P 88
isoPV1685P 99
iso1685DP 25
CTAC… 334
Measuring current

WR…S(P) 341
transformers

WS… 343
WS…-8000 343
W…AB –
AN410 365
Power supply
unit

AN450 367
AN450-133 367

12 Equipment for insulation fault location | Device overview 01/2020


ISOSCAN® ISOSCAN® ISOSCAN®
EDS150 EDS151 EDS30…

165 165 168

EDS3096PG
Medical locations for de-energised systems 2
stationary stationary portable

see Locating current injector AC 20…276 V, dependent on type


(e. g. ISOMETER® iso685-D-P) DC 20…308 V

acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve


acc. to characteristic curve acc. to characteristic curve acc. to characteristic curve

Suitable system components

01/2020 Equipment for insulation fault location | Device overview 13


Device overview residual current monitors LINETRAXX®

LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX®


RCM420 RCMA420 RCMA423 RCMS460/RCMS490 RCMS150

Catalogue page 180 183 186 189 196


Monitoring of final circuits,
Special applications DGUV Regulation 3 (German
Social Accident Insurance)
Residual distribution

TN/TT
Type of
currents system

IT

Rated frequency range 42…2000 Hz 0…2000 Hz 0…2000 Hz 0…2000 Hz 0…1000 Hz


3 Number of measuring 12 (per device) 6
1 1 1
channels 1080 (per system) virtual 12

lΔn1 50…100 % x lΔn2 50…100 % x lΔn2 50…100 % x lΔn2 10…100 % x lΔn2 min. 5 mA 50…100 % x IΔn2
Response
value

10 mA…10 A (Type AB) 3…300 mA (Type B)


lΔn2 10 mA…10 A 10…500 mA 30 mA…3 A 6 mA…20 A (Type A) 3…300 mA (DC)
Response delay ton 0…10 s 0…10 s 0…10 s 0…99 s 0…600 s
Start-up delay t 0…10 s 0…10 s 0…10 s 0…99 s 0.5…600 s
Delay on release toff 0…300 s 0…99 s 0…99 s 0…999 s 0…600 s
Operating principle, N/C operation or N/O operation N/C operation or N/O operation N/C operation or N/O operation N/C operation or N/O operation –
alarm relays
Interfaces Installation

DIN rail

Screw mounting

BMS

Modbus

Product details
(Products on
www.bender.de/en)

Type C. p. Suitable system components


CTAC… 334
Measuring current

CTUB100 337
transformers

WR…S(P) 341

WS… 343

WF… 347
RS-485 Dl-1DL 370
repeater
Power supply STEP-PS 362
units

14 Residual current monitoring systems | Device overview 01/2020


LINETRAXX® LINETRAXX® LINETRAXX®
RCMB131-01 RCMB131-02 RCMB132-01
RCMB42… MRCDB300 series RCMB300 series

199 202 206 210 213 216


Fault current monitoring
of electric vehicle AC MRCD application
charging stations

0…2000 Hz DC…100000 Hz DC…100000 Hz DC…2000 Hz DC…2000 Hz DC…2000 Hz

1 (RCMB422EC) or
3
2 (RCMB420EC)

DC 6 mA 3,5…100 mA (DC) 3,5…100 mA (DC) 3,5…100 mA (DC)


10 mA…10 A 30 mA…3 A
RMS 30 mA 3,5…100 mA (r.m.s.) 3,5…100 mA (r.m.s.)

0 s…60 min 50 ms…60 min


0 s…60 min 0 s…60 min
2s 0 s…60 min 0 s…60 min
(after reset)
N/C operation N/C operation or N/O operation N/C operation or N/O operation

RTU RTU RTU RTU

Suitable system components

01/2020 Residual current monitoring systems | Device overview 15


Device overview neutral grounding resistance monitoring (NGR) LINETRAXX®

LINETRAXX® LINETRAXX®
NGRM500 NGRM700

Catalogue page 222 227


Neutral grounding resistance monitoring Neutral grounding resistance monitoring
Special applications (NGR monitoring) (NGR monitoring)
Fault currents System
type

HRG n n

n n

n n

Phase monitoring L1, L2, L3 n

System voltage L-L* 600 V…25000 V 600 V…25000 V

RMS
n n
Harmonic

0…32
analysis

Analysis range n n

Relay operating mode Configurable fail-safe or non-fail-safe Configurable fail-safe or non-fail-safe

4 Communication Webserver, BCOM, Modbus RTU, Modbus TCP Webserver, BCOM, Modbus RTU, Modbus TCP

Maximum altitude 2000 m 5000 m

Detachable HMI for


front panel mounting n
Mounting

DIN rail n

Screw mounting n

Product details
(Products on
www.bender.de/en)

* Freely configurable in the device, taking suitable coupling devices into account.

16 Neutral grounding resistance monitoring (NGR) | Device overview 01/2020


Device overview coupling devices for NGR monitoring

CD1000 CD1000-2 CD5000 CD14400 CD25000

Catalogue page 233 235 237 239 241


Coupling device for Coupling device for Coupling device for Coupling device for Coupling device for
Special applications HRG applications HRG applications HRG applications HRG applications HRG applications

Up to ULL = 690 V Up to ULL =1000 V Up to ULL = 4300 V Up to ULL =14400 V Up to ULL =25 kV
System voltage L-L (UNGR voltage) (UNGR = 400 V) (UNGR = 600 V) (UNGR = 2500 V) (UNGR = 8400 V) (UNGR = 14.5 kV)
Moun-
ting

Screw mounting n n n n n

Product details
(Products on
www.bender.de/en)

Recommended minimum value RNGR (tripping level 50 %)


CD1000 CD1000-2 CD5000 CD14400 CD25000
Usys 400 V 600 V 690 V 400 V 600 V 690 V 1000 V 2400 V 4200 V 6 kV 6.6 V 7.2 kV 11 kV 14.4 kV 25 kV

1A 231 Ω 346 Ω 398 Ω 231 Ω 346 Ω 398 Ω 577 Ω 1386 Ω – – – – – – –

5A 46 Ω 69 Ω 80 Ω 46 Ω 69 Ω 80 Ω 115 Ω 277 Ω 485 Ω 693 Ω 762 Ω 831 Ω 1270 Ω 1663 Ω – 4


10 A (23 Ω) 35 Ω 40 Ω (23 Ω) 35 Ω 40 Ω 58 Ω 139 Ω 242 Ω 346 Ω 381 Ω 416 Ω 635 Ω 831 Ω 1443 Ω

15 A (15 Ω) (23 Ω) (27 Ω) (15 Ω) (23 Ω) (27 Ω) 38 Ω 92 Ω 162 Ω 231 Ω 254 Ω 277 Ω 423 Ω 554 Ω 962 Ω

20 A – (17 Ω) (20 Ω) – (17 Ω) (20 Ω) 29 Ω 69 Ω 121 Ω (173 Ω) 191 Ω 208 Ω 318 Ω 416 Ω 722 Ω
INGR

25 A – – (16 Ω) – – (16 Ω) (23 Ω) 55 Ω 97 Ω (139 Ω) (152 Ω) (166 Ω) 254 Ω 333 Ω 577 Ω

30 A – – – – – – (19 Ω) (46 Ω) 81 Ω (115 Ω) (127 Ω) (139 Ω) 212 Ω 277 Ω 481 Ω

40 A – – – – – – – (35 Ω) 61 Ω (87 Ω) (95 Ω) (104 Ω) (159 Ω) 208 Ω 361 Ω

50 A – – – – – – – (28 Ω) (48 Ω) – (76 Ω) (83 Ω) (127 Ω) (166 Ω) 289 Ω

100 A – – – – – – – – (24 Ω) – – – – (83 Ω) (144 Ω)

Temperature range -40…+70 °C, field calibration at 25 °C


(Limited temperature range 0…+40 °C, field calibration at 25 °C)

01/2020 Neutral grounding resistance monitoring (NGR) | Device overview 17


Device overview Universal Devices for Power Quality and Energy Measurement PEM

LINETRAXX® LINETRAXX® LINETRAXX®


PEM353 PEM575 PEM735

Catalogue page 246 251 255


Accuracy class according to IEC 62053-22 0.5 s 0.2 s 0.2 s
requirements
Normative

DIN EN 50160 (report) – – n


DIN EN 61000-4-7 (harmonic) Class II Class I Class I
DIN EN 61000-4-15 (flicker) – – n
DIN EN 61000-4-30 (PQ measurement method)
Phase voltages/
Line voltages n n n
Phase currents n n n
Neutral current I4 n (PEM353-N only) n n
Neutral current I4 (calculated) n n n
Frequency/phase angle n n n
Reactive and active power import/
Reactive and active power export n n n
Voltage unbalance/current unbalance n n n
Parameters

Power per phase and total S in kVA, P in kW, Q in kvar


Displacement factor cos (φ)/
power factor λ n n n
Total harmonic distortion (THDU/THDI) up to the 31rd up to the 63rd up to the 63rd
Harmonic components voltage up to the 31rd up to the 63rd up to the 63rd
Harmonic components current up to the 31rd up to the 63rd up to the 63rd
Transient detection – longer than 80 µs longer than 40 µs
Overvoltage (swell) – n n
Undervoltage (sag) – n n
Flicker severity PST – – n
5.1 Data recorder / HighSpeed data recorder 5/0 16/4 16/4
Waveform recorder – 32 128
Features

Digital inputs 4 6 8
Digital outputs 2 (PEM353-P only) – 2
Relay outputs (RO) 2 (PEM353, PEM353-N only) 3 4
Voltage supply AC/DC 95…250 V (47…440 Hz)
Technical aspects

Sampling rate 3,2 kHz 12,8 kHz 25,6 kHz


Temperature -25…+55 °C
Communication Modbus RTU Modbus RTU & TCP Modbus RTU & TCP

Product details
(Products on
www.bender.de/en)

18 Power Quality | Device overview 01/2020


Energy meter and Measuring current transformer for universal measuring devices

ALD1 ALE3 AWD3 PCD07 CTB41/CTB51 KBR18/KBR32

Catalogue page 266 266 266 266 263 263


Measuring current Measuring current
Type Energy meter Energy meter Energy meter SO pulse counter transformer transformer

1PH./32A MID 3PH./65A MID 3PH./6A MID (four-fold) with


Description MODBUS/RTU MODBUS/RTU MODBUS/RTU MODBUS/RTU

Product details
(Products on
www.bender.de/en)

5.1

01/2020 Power Quality | Device overview 19


Device overview measuring and monitoring relays LINETRAXX®

LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX®


VME420 VME421H VMD258 ES258 VMD420 VMD421H

Catalogue page 272 275 278 281 282 275

Energy backup for


Special applications Power plant device series VMD258
Application

Voltage monitoring

Current monitoring

AC U<, U> U<, U>


Voltage monitoring

3AC U<, U> U<, U> U<, U>

3(N)AC U<, U> U<, U>

DC U<, U> U<, U>

VME421H-D-1
AC/DC systems 3AC
Measuring range/ AC/DC systems (L-N) 0…288 V (L-N) 0…288 V
9,6…150 V 690/500/480/440/
nominal system voltage Un 0…300 V 400/230/110/100 V (L-L) 0…500 V (L-L) 0…500 V
VMD421H-D-2
70…300 V

Frequency f<, f> f<, f> f<, f> f<, f>

Phase sequence

Phase failure

Asymmetry
5.2
Supply voltage Us external system system external system
monitoring

1 AC with Us
Current

3 AC with Us

Special function
Installation

DIN rail

Screw mounting

Product details
(Products on
www.bender.de/en)

20 Measuring and monitoring relays | Device overview 01/2020


LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX® LINETRAXX®
VMD423/VMD423H VMD460-NA VMD461 CME420 CMD420/CMD421 CMS460 GM420

288 291 296 302 305 308 311


Interface Protection Interface Protection Interface Protection
System/Decoupling System/Decoupling System/Decoupling Loop monitoring
protection relay protection relay protection relay

U<, U<<, U<, U<<, U<<<,


U>, U>>, U10min> U>, U>>, U>>>
U<, U<<, U<, U<<, U<<<,
U>, U>>, U10min> U>, U>>, U>>>
U<, U<<, U<, U<<, U<<<,
U<, U>, U10min> U>, U>>, U10min> U>, U>>, U>>>

VMD461
(L-N) AC 50…260 V
(L-L) AC 87…450 V
(L-N) 0…288 V (L-N) 0…300 V (DC+ / DC–) DC 50…450 V
(L-L) 0…500 V (L-L) 0…520 V VMD461 +CD440
(L-N) AC 250…690 V
(L-L) AC 440…1200 V
(DC+/DC-) DC 250…1200 V
f<, f<<, f<<<,
f<, f> f<, f<<, f>, f>> f>, f>>, f>>>

5.2
external (VMD423)
external external
system (VMD423H)
l<, l> l<, l>

l<, l> l<, l>

RS-485 interface, RS-485 interface,


Islanding detection: Islanding detection: RS-485 interface
-ROCOF (df/dt) -ROCOF (df/dt)
-Vector shift -Vector shift

01/2020 Measuring and monitoring relays | Device overview 21


Device overview coupling devices

AGH150W-4 AGH204S-4 AGH520S AGH675S-7/ AGH675S-7MV AGH676S-4

Catalogue page 324 326 327 328 330


Extension of the nominal voltage Extension of the nominal voltage Extension of the nominal voltage Extension of the nominal voltage Extension of the nominal voltage
Application range for ISOMETER®s range for ISOMETER®s range for ISOMETER®s range for ISOMETER®s range for ISOMETER®s
AC 0…1150 V, AC 0…1300 V / AC, 3(N)AC, DC 0…7.2 kV
Nominal system voltage Un DC 0…1760 V AC 0…1650 V AC/3(N)AC 0…7200 V AC, 3(N)AC, DC 0…15.5 kV AC/3(N)AC 0…12 kV

IRDH275/375
IRDH275BM
Device family

IR420-D64
iso685-D
iso685-S

Product details
(Products on
www.bender.de/en)

Device overview measuring current transformers

W0-S20…W5-S210, W10/600 CTAC… CTUB100-CTBC…

Catalogue page 332 334 337


Characteristics
CTUB101-CTBC120(P)

CTUB101-CTBC210(P)

CTUB102-CTBC120(P)

CTUB102-CTBC210(P)
CTUB101-CTBC20(P)

CTUB101-CTBC35(P)

CTUB101-CTBC60(P)

CTUB102-CTBC20(P)

CTUB102-CTBC35(P)

CTUB102-CTBC60(P)

CT type
CTAC120(P)

CTAC210(P)
CTAC35 (P)

CTAC60 (P)
CTAC20(P)
W10/600

W3-S105

W4-S140

W5-S210
W0-S20

W1-S35

W2-S70

Inside diameter 10 20 35 70 105 140 210 20 35 60 120 210 20 35 60 120 210 20 35 60 120 210
Dimensions

6
(mm)

Width x height
Strip length
EDS440
EDS441
EDS441-LAB
EDS460/490
Device family

EDS461/491
RCM420
RCMA420
RCMA423
RCMS460/490

Product details
(Products on
www.bender.de/en)

22 System components | Device overview 01/2020


WR…S(P) WS…/WS…-8000 WS…S WF…

341 343 345 347


split-core split-core flexible
WR115x305S(P)

WR150x350S(P)

WR200x500S(P)

WS20x30-8000

WS50x80-8000
WR70x175S(P)

WS80x120S

WS80x160S
WS80x120

WS50x80S

WS80x80S
WS20x30

WS50x80

WF1200

WF1800
WF170

WF250

WF500

WF800

70 x 175 115 x 305 150 x 350 200 x 500 20 x 30 50 x 80 80 x 120 20 x 30 50 x 80 50 x 80 80 x 80 80 x 120 80 x 160 6
170 250 500 800 1200 1800

01/2020 System components | Device overview 23


Device overview isolating transformers, transformers for operating theatre lights

ES710 DS0107 ESL0107

Catalogue page 350 355 358


Supply of three-phase loads
Application Design of medical IT systems Supply of operating theatre luminaires
in group 0, 1 or 2 medical locations
Type of distribution system single-phase three-phase single-phase
Input AC 230 V 3AC 400 V AC 230 V (±5 %, ±10 %)
Voltages

Output AC 230 V 3NAC 230 V AC 23…28 V


Frequency range 50…60 Hz 50…60 Hz 50…60 Hz
2000 VA
3150 VA 120 VA
3150 VA
4000 VA 160 VA
4000 VA
5000 VA 280 VA
Power 5000 VA
6300 VA 400 VA
6300 VA
8000 VA 630 VA
8000 VA
10000 VA 1000 VA
10000 VA
vertical
Design type

horizontal
encapsulated
(protection class B)

Product details
(Products on
www.bender.de/en)

Device overview measuring transducer

6
RK170

Catalogue page 360


Application Conversion of DC currents
Input

Current DC 0…400 µA

Current 0/4…20 mA
Output

Voltage DC 0…10 V

Product details
(Products on
www.bender.de/en)

24 System components | Device overview 01/2020


Device overview power supply units

STEP-PS AN410 AN450

Catalogue page 362 365 367


Application for measuring current transformers for DC 24 V power supply for voltage supply

Rated voltage DC 24 V DC 24 V AC 20 V, 50…60 Hz

AC 85…264 V, 45…65 Hz AC 90…264 V AC 230 V, 50…60 Hz


Rated input voltage UIN DC 95…250 V DC 120…370 V AC 127 V, 50…60 Hz

Product details
(Products on
www.bender.de/en)

Device overview measuring instruments

6
7204 7220 9604 9620

Catalogue page 369 369 369 369


Input current 0…400 μA 0…20 mA 0…400 μA 0…20 mA

Dimensions (mm) 72 x 72 72 x 72 96 x 96 96 x 96

IRDH275/375
Device family

IRDH275B/375B

IRDH575

iso685…

Product details
(Products on
www.bender.de/en)

01/2020 System components | Device overview 25


Device overview interface converters and repeaters

DI-1DL DI-2USB

Catalogue page 370 372


Interface repeater Interface converter
Application BMS bus BMS/USB
Input RS-485 RS-485
Input

Connection screw-type terminal screw-type terminal

Cable length ≤ 1200 m ≤ 1200 m

Output RS-485 USB

Connection screw-type terminal USB Type B


Output

Cable length ≤ 1200 m ≤5m


Expansion of bus ≤ 30
devices
Supply voltage US AC 85…260 V, 50…60 Hz via USB

Particular features Driver CD

Product details
(Products on
www.bender.de/en)

Device overview Relay module Device overview Charge Controller

6 IOM441 CC612

Catalogue page 373 Catalogue page 375


for extension
Application Application Charge Controller
of EDS44x applications

Relay number 12 N/O contacts DC 6 mA sensor

Supply voltage US via BB bus Supply voltage US DC 12 V

Interface BB bus Modbus


Interface

Connection push-wire terminal / BBbus PCB eHz meter

Relay operation configurable Modem 3G modem (optional)

Product details Product details


(Products on (Products on
www.bender.de/en) www.bender.de/en)

26 System components | Device overview 01/2020


Device overview gateways

COMTRAXX® COMTRAXX® COMTRAXX® COMTRAXX® COMTRAXX®


COM462RTU COM465IP COM465DP COM465ID CP700

Catalogue page 379 382 386 390 394


Condition Monitor/
Application BMS-Modbus RTU-Gateway Condition Monitor/Gateway Condition Monitor/Gateway Condition Monitor/Gateway
PROFIBUS-Gateway
Protocol input BMS BMS/Modbus RTU/TCP BMS/Modbus RTU/TCP isoData/Modbus TCP BMS/Modbus RTU/TCP
Ethernet/Modbus TCP,
Protocol output Modbus RTU Ethernet/Modbus TCP Ethernet/Modbus TCP/OPC-UA Ethernet/Modbus TCP
PROFIBUS DP
Display LCD/LED LED LED LED 7”-colour LCD

Alarm messages 1, 2)
1, 2)
1, 2)
1, 2, 3)

Measured values 1, 2)
1, 2)
1, 2)
1, 2, 3)

Device parameter 1)
1)
1)
1)
setting
Alarm list 1)
1)
1)
1, 3)
Functions

History memory 1)
1)
1)
1)

Diagrams 1)
1)
1)
1, 3)

Visualisation 1)
1)
1)
1)

E-mail notification 1, 4)
1, 4)
1, 4)
1, 4)

Device tests 1, 2)
1, 2)
1, 2)
1, 2)

PEM… and energy 1)


1)
1)
1)
meter support
SNMP 1)
1)
1)
1)

Data logger 1)
1)
1)
1)

BMS screw-type terminal screw-type terminal screw-type terminal screw-type terminal


Connection

Modbus RTU screw-type terminal screw-type terminal screw-type terminal screw-type terminal

isoData screw-type terminal

Output screw-type terminal RJ 45 RJ 45, Sub-D 9-pole RJ 45 RJ 45


AC/DC 24…240 V, AC/DC 24…240 V,
Supply voltage US AC/DC 76…276 V AC/DC 24…240 V DC 24 V
requirements

DC 24V DC 24V
System

Browser Internet Explorer, Chrome, Internet Explorer, Chrome, Internet Explorer, Chrome, Internet Explorer, Chrome, 6
Firefox etc. Firefox etc. Firefox etc. Firefox etc.

Product details
(Products on
www.bender.de/en)

1)
Functions available on the web server – accessible via a personal computer with browser
2)
Available via the protocol
3)
On the device’s own LC display
4)
TLS/SSL Support

01/2020 System components | Device overview 27


Device overview alarm indicator and test combinations

COMTRAXX® COMTRAXX® COMTRAXX®


Visualisation
CP9xx MK800 (DI400) MK2430

Catalogue page 397 400 404 407


MEDICS® systems
Messages/
displays

RCMS Residual current monitoring system

EDS insulation fault locator

Flush-mounting
Installation type

Cavity wall mounting

Cable-duct mounting

Panel mounting

Surface mounting

Digital inputs (potential free) 12 0/16 0/12

N/O or N/C operation selectable selectable selectable


Inputs/outputs

Relay outputs 1 1 1

N/O or N/C operation programmable programmable programmable

Common alarm programmable programmable programmable

System fault alarm programmable programmable programmable

Languages selectable 25 21 20 programmable

Standard display Graphic LCD (7“, 15.6“, 24“) 4 x 20 characters 4 x 20 characters


Parameter setting/text message

Additional text display 3 x 20 characters 3 x 20 characters

Standard texts

Freely configurable text messages 1000 200


History memory, maximum number 1000 1000 250
of data records
Real-time clock

Parameterisation software integrated TMK-Set V 4.xx (USB, BMS) TMK-Set V 4.xx (USB, BMS)

Messages/alarms, medical gases acc. to EN475, EN737-3 acc. to EN475, EN737-3 acc. to EN475, EN737-8
6 RS-485 (BMS protocol) 2

BMS address range 1…150 internal: 1 (…150), external: 1…99 1…150


Interfaces

Master redundancy, BMS internal

Master redundancy, BMS external

USB

Ethernet (TCP/IP)

Supply voltage US DC 24 V/AC 250 V AC/DC 24 V AC/DC 24 V

Stored energy time in the event of power failure ≥ 15 s ≤2s ≤ 15 s

Product details
(Products on
www.bender.de/en)

28 System components | Device overview 01/2020


Device overview POWERSCOUT®

POWERSCOUT®

Catalogue page 408


Multi-tenant Unlimited

User management Unlimited

Logger Unlimited (all measured values)

Real-time capable (alerting) –

Parameterisation of sensors/devices –

Web front end

Cloud

On-premise installation
Functions

Max. number of devices/data points Unlimited

Creation of dashboards

Event aggregation on the main page

Configuration of an individual main page

Reporting

Export data csv export

Import data csv import

Virtual measuring point calculation

Login overview

Graph

Event statistics

Measurement statistics

Text editor

Table view
Widgets

Alarm state
6
Event protocol

Gauge

Heat map

Sankey diagram

Bar graph

Product details
(Products on
www.bender.de/en)

01/2020 System components | Device overview 29


Device overview ATICS® switchover and monitoring devices

ATICS®-…-ISO ATICS®-…-DIO

Catalogue page 414 418

Application Unearthed safety power supplies Safety power supplies

2-pole: 250 V
Rated insulation voltage 2-pole: 250 V 4-pole: 400 V
Nominal system 2-pole: AC 230 V
AC 230 V (AC 160…276 V)
Voltages

voltage Un 4-pole: 3N AC 400/230 V

Frequency range 48…62 Hz 48…62 Hz

Insulation monitoring 10 kΩ…1 MΩ


Measuring range
Insulation monitoring 50…500 kΩ
Response value Ran1

Digital inputs/relays 1/1 4/4

Interface/protocol RS-485/BMS RS-485/BMS

Pluggable screw
Connection

terminals (up to 125 A)

Screw terminals (160 A)


Installation

DIN rail

Screw mounting 4 x M5 6 x M5

Product details
(Products on
www.bender.de/en)

7.1

30 Switching equipment and test systems | Device overview switchover and monitoring devices 01/2020
Device overview UNIMET® test systems

UNIMET® 300ST UNIMET® 400ST UNIMET® 610ST UNIMET® 810ST

Catalogue page 424 427 431 434

Electrical equipment

Electric hospital and


Application

care beds
Medical electrical 1)
equipment

Electrical machines

AC 100…120 V,
Supply voltage US AC 230 V AC 230 V AC 230 V AC 220…240 V
Voltages

Voltage measurement AC 90…264 V AC 90…264 V AC 90…264 V AC 90…264 V


Measuring range
Load current 0.01…16 A 0.01…16 A 0.01…16 A 0.01…16 A
measurement

manual
Test sequence

semi-automatic

automatic

Data exchange UNIData300 UNIData300/400 UNIMET® 610ST Control Center UNIMET® 810ST Control Center

Product details
(Products on
www.bender.de/en)

Medical electrical equipment without patient connections


1)

7.2

01/2020 Switching equipment and test systems | Device overview test systems 31
Device-overview_HK_en / 01/2020 / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the version that was valid at the time of printing.

Bender GmbH & Co KG


P.O. Box 1161 • 35301 Grünberg • Germany
Londorfer Straße 65 • 35305 Grünberg • Germany
Tel.: +49 6401 807-0 • Fax: +49 6401 807-259
E-Mail: info@bender.de • www.bender.de BENDER Group
Photos: Fraport AG/Fotolia: Oleg Fedorenko, Eyematrix, Edler von Rabenstein/iStock: beerkoff, grybaz grybaz/Adobe Stock: Sergey Nivens and Bender Archiv.

You might also like