Nama: Taufan Raafi’ud S.

P
NRP: 04211840000035
Mesin Fluida A
Laporan Perhitungan Pemilihan Pompa
A. Ship’s Main Dimension

Name Blue Arrow


L 103 m
B 17,4 m
D 10 m
T 7,4 m
Cb 0,78

B. Ballast’s System Design

C. Calculation of Ballast Volume

Volume displacement
(m3)
L= 103 m
B= 17,4 m
T= 7,4 m
Cb= 0,78
∇= L x B x T x Cb
= 108 x 19 x 10 x 0,78
= 10344,58 m3
Mass Displacement
(ton)
∇= 10344,58 m3
ρ= 1,025 ton/m3
Δ= ∇xρ
= 16005,6 x 1025
= 10603,19 ton
Ballast Mass
Wballast = 17% x Δ
= 1803 ton
Ballast Volume
Wballast = 1803 ton
ρ= 1,025 ton/m3
Vballast = Wballast / ρ
= 2789 / 1,025
= 1759 m3
D. Pump Capacity

Pump Capacity
Q= V/t m3/h
V= 1759 m3
t= 8 jam
Q= V/t
= 1759/8
= 219,82 m3/h
= 0,061 m3/s
E. Calculation of Ballast Pump’s Head
a. Head Static
Head Static
(Hs)
Hs = T + 0.75
Hs = T + 0.75
= 7,4 + 0.75
= 8,15m

b. Head Loss in Suction Line

Mayor Losses
Reynold Number
Re = ( V x d ) / υ
d: 180,0 mm
V: 3 m/s
u: 0,00000089 m2/s
Re = (V x d) / u
= (3x 0,18) / 0,000000822
= 605584,84 = Turbulen

Relative Pipe Roughness= e/d


e for mild steel (forged) = 0,025
d = 180mm

Relative Pipe Roughness=


e/d

=
0,000138889
Friction Factor=
0,0145

L=
Length of Suction Side

=
88
m

v=
3
m/s

d=
180,0
mm

=
0,18
m
Major Losses suction =
f x L x v^2 / (D x 2g)
=
0,0145 x 88 x 3^2 / (0.18 x 2 x 9.8)

=
3,255
m

Minor Losses
No. Accesoris n k nxk
1 Gate Valve 12 0,15 1,8
2 NRV 8 1,23 9,84
3 T-Joint 12 0,28 3,36
4 Flanged Long Radius 90' elbow 15 0,2 3
6 Bell-Mounted Pipe End 8 0,05 0,4
7 Strainer 4 2,5 10
Σ= 28,4

Minor Losses suction = (Σ n.k) x v² /2g


(28,4 x 32) / 2 x
= 9.8
= 13,041m

HLs = Major Losses + Minor Losses


= 3,255 + 13,041
= 16,296m
c. Head Loss in Discharge Line

Mayor Losses
Reynold Number
Re = ( V x d ) / υ
d: 180,0 mm
V: 3 m/s
u: 0,00000089 m2/s

Re = (V x d) / u
= (3x 0,18) / 0,000000822
= 605584,84 = Turbulen

Relative Pipe Roughness= e/d


e for mild steel (forged) = 0,025
d = 180mm

Relative Pipe
e/d
Roughness=
0,00013888
=
9
Friction Factor= 0,0145

Length of
L= Suction Side
= 3,5 m
v= 3 m/s
d= 180,0 mm
= 0,18 m

Major Losses Discharge = f x L x v^2 / (D x 2g)


= 0,0145 x 3,5 x 3^2 / (0.18 x 2 x 9.8)
= 0,129m

Minor Losses
No. Accesoris n k nxk
1 SDNRV 6 1,35 8,1
2 Gate Valve 3 0,15 0,45
3 Flanged Long Radius 90' elbow 4 0,2 0,8
4 T-Joint 6 0,28 1,68
Σ= 11,03

Minor Losses
suction = (Σ n.k) x v² /2g
= (11,03 x 32) / 2 x 9,8
= 5,065m

HLd = Major Losses + Minor Losses


= 0,129+5,065
= 5,194
d. Head Total

Htot = Hs + Hp + Hv + HLs + HLd


= 8,15 + 0 + 0 + 16,296+ 5,194
= 29,64
F. Ballast’s Pump Selection

Ballast Pump Selection


Required Capacity = 219,82 m^3/h
Required Head = 29,64 m

Manufacturer SILI
Type VSN 250-55
Cap. [m^3/h] 250
Head [m] 50
Power [kW] 55
RPM 1800
Quantityof Pole 4 Pole
Frequency 60Hz

Lampiran