UNO 7.6 and 8.6 is a feature-rich ABB is the only manufacturer who Highlights
transformerless inverter that is can offer a fully-loaded, large- −− Dual independent MPPT channel
powerful and flexible enough to residential system using one inverter. compatible with a 40A residential
operate like two inverters. This ABB‘s high speed and precise Multiple panel sized breaker (7.6kW model)
means fewer inverters are needed Power Point Tracker (MPPT) algorithm −− Outdoor Type 4X rated enclosure
to accommodate residential enables real-time power tracking and for unrestricted use under any
installations. improved energy harvesting. environmental conditions
The dual MPPT input enables more −− Wide input range for increased
Reducing cost of installation. orientations of PV strings to be stringing flexibility
Available in 7.6kW or 8.6kW, the ABB connected at the same time and −− Minimizes installation space with
UNO 7.6 and 8.6 inverters are well unbalanced strings on each MPPT side-by-side installation
suited for North American residential channel; thereby, maximizing the −− 97 percent CEC efficiency
rooftop installations and provide the energy harvesting and flexibility.
system flexibility, levels of performance These inverters are extremely
and reliability that designers need. lightweight and simple to wall mount,
The wide input voltage range makes the while still featuring an integrated DC
inverter suitable for installations utilizing disconnect with combiner, lowering
a reduced string size. overall installation cost.
Additional highlights −− Compliant with NEC 690.12 when
−− Single-phase and split-phase output used with ABB‘s Rapid Shutdown
−− Offers an extra quiet, transformer-less device
inverter architecture −− Comes standard with DC Arc Fault
−− Fully integrated DC disconnect and Circuit Interruptor (AFCI) to comply
wiring box saves installation time and with NEC 690.11
cost
−− Flexible data monitoring options to
view inverter performance where and
how you need it
−− RS-485 communication interface (for
connection to laptop of data logger)
−− Available with the optional VSN300
Wifi Logger Card for wireless
monitoring
RESIDUAL CURRENT
DC DETECTION
AFDI
IN2.1(+)
+ +
IN2.2(+) MPPT 2
IN2.1(+) (DC/DC)
+
IN2 IN2
PE
IN2.1(-)
IN2.1(-) IN2
RS485
- -
+ T/R
IN2.2(-)
- - T/R
RTN
REMOTE CONTROL*
+R
-R
DC/DC DC/AC
DSP DSP ALARM
CONTR. CONTR. N.C
N.O
GROUND C
FAULT
DETECTION µP ALARM
N.C
N.O
CONTROL CIRCUIT C