Fieldbus Technology Part Number Keys In-Cabinet Block I/O
On-Machine Modular I/O FEN20 Part Number Key
BL67 Gateways Part Number Key F EN 20 - 4 DIP - 4 DXP - E
Fixed I/O Station Connectors and Mounting
BL 67 - GW - EN -
(Blank) = Part Number Specific - Refer to Documentation for details
Network E = Eurofast M12x1 connector on back of device - male only
Modular IO System Special Connector Options AS = AS-Interface ER = Eurofast M12x1 connector on back of device- male only
Environment 4F = 4 pin power (Multiprotocol gateway only) DP = PROFIBUS-DP also with removable terminal blocks
Network DN = DeviceNet E-A = Eurofast M12x1 connector on back of device - male only
67 =On-Machine IP67 System EN = Ethernet (EtherNet/IP, I/O powered by Aux Power.
EN = Multiprotocol EtherNet, PROFINET®, EtherNet/IP™
Gateway Type DPV1 = PROFIBUS DPV1 Modbus/TCP, Profinet) R-A = Removable terminal blocks. I/O powered by Aux Power
GW =Standard Gateway ER - A = Eurofast M12x1 connector on back of device - male only
DN = DeviceNet Environment also with removable terminal blocks. I/O powered by
PG =Programmable Gateway CO = CANopen
20 - In-Cabinet IP20 System Aux Power
EN-V3 = Programmable Gateway (CodeSys 3) for Ethernet
Number of IO Points Type of IO
BL67 Slices Part Number Key 4 = 4 points of IO DIP = PNP Digital Input
16 =16 points of IO DOP = PNP Digital Output
32 =32 points of IO DXP = Configurable PNP Input or Output
DIN = NPN Digital Input
BL 67 - 8 DO - 0.5A - P Type of IO DXN = Configurable NPN Input or Output
DIP = PNP Digital Input S = PNP Inputs (Legacy)
Modular IO System DOP = PNP Digital Output SN = NPN/PNP Inputs (Legacy)
Discrete IO Secondary Descriptor DXP = Configurable PNP Input or Output XSG = Configurable PNP Input or Output (Legacy)
Environment
P = PNP, positive switching DIN = NPN Digital Input Number of Input Points
67 = On-Machine IP67 System DXN = Configurable NPN Input or Output
N = NPN, negative switching 4 = 4 points of I/O
Number of IO PD = PNP, positive switching with per port Diagnostics S = PNP Inputs (Legacy)
16 =16 points of I/O
NO = Normally Open Relays SN = NPN/PNP Inputs (Legacy)
1 = 1 Channel
XSG = Configurable PNP Input or Output (Legacy)
2 = 2 Channels
4 = 4 Channels IO Descriptors
8 = 8 Channels
16 = 16 Channels Output Descriptors Analog Descriptors
Type of IO 0.1A
0.5A
= 100mA outputs
= 500mA outputs
I
V
= Current
= Voltage
On-Machine Block I/O
DI = Digital Inputs CNT/ENC = High Speed Counter
2A = 2A outputs PT = RTD
DO = Digital Outputs SSI = SSI Encoder Interface
R = Relay Outputs TC = Thermocouple BL Compact Part Number Key
XSG = Configurable Digital Inputs or Outputs RS232 = RS232 Serial
AI = Analog Inputs RS485/422 = RS485 or RS422 Serial
AO = Analog Outputs PF = Power Feed BLC EN - 8 M12 L T - 4AI-VI - 8DI-P
RFID = Radio Frequency Identification IOL = IO-Link master
I/O Type Position #2
Flexible Block I/O Station
2RFID-A (PROFIBUS
BL67 Bases Part Number Key 4DI-P
DP only)
Network 4DI-PD
8DI-P 4AI-VI
DN = DeviceNet 8DI-N 4AI4AO-VI
BL 67 - B - 1 M16 - 14 - 0.5M - DP = PROFIBUS DP 8DI-PD 2AI2AO-VI
CO = CANopen 8XSG-PD 2AI-I
EN = Multiprotocol (EtherNet/IP™, Modbus® 4DO-0.5A-P 2AI-V
Modular IO System Unique Identifier TCP, PROFINET®) 2AO-I
4DO-2A-P
Environment P = Paired Base, (eg: in 4M12 standard pinout has EC = EtherCat 4DO-2A-N 2AO-V
0 and 4 on first connector, P base has 0 and 1 8DO-0.5A-P 2AI-PT
67 = On-Machine IP67 System Number of IO Ports
on first connector) 8DO-0.5A-N 2AI-TC
Base VO = Power Feed base that only refreshes Output 1 = 1 port 2RFID-S 4AI-TC
B = Base voltage and carries input voltage from previous 2 = 2 ports 4IOL
segment 3 = 3 ports
Number of Connectors VI = Available power pins are directly connected to 4 = 4 ports I/O Type Position #1
1 = 1 Connector backplane power, not fused by slice. 5 = 5 ports 4DI-P 2RFID-A (PROFIBUS DP only)
2 = 2 Connectors 6 = 6 ports 4DI-PD 4AI-VI
4 = 4 Connectors Length of built-in Cordset 8 = 8 ports 8DI-P 4AI4AO-VI
8 = 8 Connectors 16 = 16 ports (only with M8 connectors) 8DI-N 4AO-V
Number of Pins Type of I/O Connectors 8DI-PD 2AI2AO-VI
Type of Connectors
(blank) = Standard Number for connector 8XSG-PD 2AI-I
M8 = picofast ® - M8x1 M8 = picofast® (M8x1)
4 = 4 Pins 4DO-0.5A-P 2AI-V
M12 = eurofast ® - M12x1 M12 = eurofast® (M12x1)
8 = 8 Pins 4DO-2A-P 2AO-I
M16 = versafast ® - M16x0.75 4DO-2A-N 2AO-V
M23 = multifast ® - M23x1
14 = 14 Pins Connector Modifier
19 = 19 Pins 8DO-0.5A-P 2AI-PT
RSM = Male minifast ® Power connector - 7/8-16UN (Blank) = Standard Nickel Plated Brass 8DO-0.5A-N 2AI-TC
W = Reverse Keyed, Nickel Plated Brass 2RFID-S 4AI-TC
V = Stainless Steel 4IOL
Housing Style
In-Cabinet Modular I/O S = Small Housing - One I/O slice, no Aux. Power
Auxilliary Power Connector
(blank) = No Aux Power Connector
M = Medium Housing - One I/O slice
L = Large Housing - Two I/O slices T = Aux Power Present - Built in Tee
BL20 Gateway Part Number Key H = High Power
Turck Block Part Number Key
BL 20 - - GW - EN -
Ethernet Type (used w/network “EN”) TB EN - L4 - 8 DIP - 8 DIP
Modular IO System
(blank) = Multiprotocol (Economy Gateway), Type of IO
Environment or ModBus (Standard Gateway)
Turck Block
IP = EtherNet Network DIP = PNP Digital Input
20 = In-Cabinet IP20 System DOP = PNP Digital Output
PN = Profinet EN = Ethernet (EtherNet/IP, Modbus/TCP, Profinet) DXP = Configurable PNP Input or Output
Economy DP = Profibus
Network DIN = NPN Digital Input
(blank) = Standard Gateway PN = ProfiSafe, Profinet (Safety Module) DON = NPN Digital Output
(Screw or Tension Clamp, up to 72 slices) EN = Ethernet IP = CIP Saftey, Ethernet/IP (Safety Module) DXN = Configurable NPN Input or Output
E = Economy Gateway DP or DPV1 = PROFIBUS DPV1 IL = IO-Link Slave AI = Analog Input
(Tension Clamp Only, up to 32 slices) DN or DNET = DeviceNet™ AO = Analog Output
CO or CANOPEN = CANopen Power and I/O Connector Type
Gateway Type EC = EtherCAT L4 = 7/8” (4 pin) power with M12 (5 pin) I/O Number of Input Points
GW = Standard Gateway EN-V3 = Programmable gateway (CodeSys 3) for Ethernet L5 = 7/8” (5 pin) power with M12 (5 pin) I/O 2 = 2 points of IO
GWBR = Standard Gateway (DeviceNet and CANOPEN only) S1 = M8 (4 pin) power with M8 (3 pin) I/O 4 = 4 points of IO
PG = Programmable Gateway S2 = M8 (4 pin) power with M12 (5 pin) I/O 8 = 8 points of IO
S3 = M8 (4 pin) power with M12 (8 pin) I/O 16 = 16 points of IO
M1 = M12 (5 pin) I/O (Reserved for IO-Link Slave)
BL20 Slices Part Number Key L1 = 7/8” (5 pin) power (ProfiSafe Module Only)
Type of IO
DIP = PNP Digital Input AI = Analog Input
Number of IO Points DOP = PNP Digital Output AO = Analog Output
BL 20 - E - 16 DO - 24VDC - 0.5A - P (Blank) = Reserved for EN1, FDIO1 & PLC DXP = Configurable PNP RFID = Radio Frequency Identification
2 = 2 points of IO Input or Output COM = Serial Ports (RS485 or RS232)
Modular IO System Discrete I/O Secondary Descriptor 4 = 4 points of IO DIN = NPN Digital Input EN1 = Ethernet Spanner
P = PNP, positive switching 8 = 8 points of IO DON = NPN Digital Output FDIO1 = Functional Safety Digital
Environment
N = NPN, negative switching 16 = 16 points of IO DXN = Configurable NPN Inputs/Output
20 = In-Cabinet IP20 System NO = Normally Open Relays Input or Output PLC = Turck PLC
Economy Modules NC = Normally Closed Relays IOL = IO-Link Master
CO = 1 Normally Open, 1 Normally Closed
(blank) = Standard
NAMUR = NAMUR Digital Inputs
E = Economy Module Ethernet, PROFIBUS® DP AIM Part Number Key
I/O Descriptor
Number of I/O
1 = 1 Channel Output Descriptors
F EN - IOM 8 8 - 0001 - - DN
2 = 2 Channel 0.5A = 500mA outputs
4 = 4 Channel 2A = 2A outputs
8 = 8 Channel R = Relay Outputs Fixed I/O Station Subnet Type
16 = 16 Channel Diagnostic Type DN =DeviceNet Master
32 = 32 Channel
Analog Descriptors
I(0/4…20MA) = Current L = Standard Diagnostics; Group Diagnostics Ethernet Type Indicator (X Diag. type)
Type of I/O X = Deluxe Diagnostics; Per Port Input Diagnostics,
U(-10/0…+10VDC) = Voltage MB = Modbus TCP/IP™
DI = Digital Inputs SSI = SSI Encoder Interface U/I = Voltage or Current Per Point Output Diagnostics PG =Programmable, EtherNet/IP™
DO = Digital Outputs RS232 = RS232 Serial PT/NI-2/3 = 2 or 3 wire RTD G = Deluxe Diagnostics; Per Port Input Diagnostics, EN =EtherNet/IP™
AI = Analog Inputs RS485-422 = RS485 or RS422 Serial THERMO-PI = Thermocouple Per Point Output Diagnostics, 2 Amp outputs, PN =Profinet
AIH = Hart Analog Inputs PF = Power Feed U/I-4PT/NI = Voltage, Current or RTD Multiprotocol Modbus, PROFINET®, EtherNet/IP™
AO = Analog Outputs BR = Bus Refreshing TC = Thermocouple Generic Identifier
AOH = Hart Analog Outputs IOL = IO-Link master
Network
Operating Voltage Rating Refer to documentation for specifics
RFID-A = Radio Frequency Identification EN =Ethernet
RFID-S = Radio Frequency Identification (blank) = 24 Volts - Direct Current DP =Profibus ® DP Number of Output Points
SWIRE = SWIRE Master for Motor Starters 24VDC = 24 Volts - Direct Current 4 =4 Output Points 12 =12 Output Points
2CNT-2PWM = High Speed Counter and PWM outputs 120/230VAC = 120 or 230 Volts - Alternating Current IO Type 8 =8 Output Points 16 =16 Output Points
XSG =Configurable Input or Output Points
IOM =Static Input and Output Points Number of Input Points
BL20 Bases Part Number Key IM =Input Only 8 =8 Input Points 20 =20 Input Points
OM =Output Only 12 =12 Input Points 24 =24 Input Points
16 =16 Input Points 32 =32 Input Points
BL 20 - S 6 T - S.. -
Unique Identifier DeviceNet™, AS-I® AIM Station Part Number Key
Modular IO System
B = Power Base that only feeds power to the right
Environment CJ = Cold Junction - For use with Thermocouple slice F DN P - L 04 04 G - - T T - V
20 = In-Cabinet IP20 System
Type of Terminal (see note for available combinations) Connector Material/Modifier
Modular IO System
Type of Module S = Signal Terminal (blank) = Nickel Plated Brass
S = Single Module B = Power/Signal Terminal Network V =Stainless Steel
B = Block Module C = C-Rail Terminal DN =DeviceNet ® Stations A =Auxiliary Power (ASi stations only)
P = Power Module AS =AS-I Stations Aux Power Connector
Connection Technology
Number of Terminal Rows Housing Style T =minifast® Pass Through, both male and female
T = Tension Clamp
3 = 3 Rows S = Screw Terminal P =8 I/O Ports/Aux power/220 mm long M =minifast® drop, single male
4 = 4 Rows L =8 I/O Ports/197 mm long W =minifast® drop, single male, rotated keyway
6 = 6 Rows Q =4 I/O Ports/148 mm long C =eurofast® Pass Through, both male and female
4 =4 I/O Ports/125 mm long E =eurofast® Drop, single male
Note: Available combinations: 8 =8 I/O Ports/156 mm long DeviceNet Connector Configuration
SBB = Signal, Power, Power SBC = Signal, Power, C-Rail Term. Type of IO T =minifast®, Pass Through, both male and female
SBBC = Signal, Power, Power, C-Rail Term. SBCS = Signal, Power, C-Rail Term., Signal (blank) = non-discrete S =minifast®, Pass Through, both male and female,
SBBS = Signal, Power, Power, Signal SBCSBC = Signal, Power, C-Rail Term., Signal, Power, C-Rail Term. L =NPN/PNP, Individual Open and screw terminal through back of module
SBBSBB = Signal, Power, Power, Signal, Power, Power Short-circuitDetection M =minifast®, Drop, single male
P =PNP, Individual Open and Short-circuit Detection W =minifast®, Drop, single male, rotated keyway
S =PNP, Group Short-circuit Detection, Earth Ground C =eurofast®, Pass Through, both male and female
Pin 5 E =eurofast®, Drop, single male
CPG =Combined - PNP Input and Output on same connector Analog Description
CSG =Combined - PNP Input and Output on V/I = Current or Voltage input for analog module
separate connectors
IO Description
XSG =Universal - PNP Input or PNP Output
N =NPN, Group Short-circuit Detection, Earth Ground G =0.5 Amp Outputs
H =1.4 or 2.0 Amp Outputs
Pin 5
AI =Analog Input
E =E-Connect Safety Station
G =0.5A Outputs Number of Inputs
Number of Inputs 00 =0 Outputs 04 =4 Outputs
00 =0 Inputs 08 =8 Inputs 01 =1 Outputs 08 =8 Outputs
01 =1 Inputs 12 =12 Inputs 02 =2 Outputs 16 =16 Outputs
02 =2 Inputs 16 =16 Inputs 03 =3 Outputs
04 =4 Inputs
Turck Inc. | 3000 Campus Drive, Minneapolis, MN 55441 | T +1 763 553-7300 | F +1 763 509-7709 | www.turck.com B0004