SLAB
Ø The reinforcement detailing in slabs shall be provided as shown in the figure below.
Ø Cranks in slabs are not permitted due to poor performance in seismic shaking.
Ø Minimum slab thickness shall be 100mm.
Ø Generally, slab thickness shall be calculated as shorter spam/28 or 100 mm, whichever is higher.
Ø The minimum cover to reinforcement shall be not less than 15 mm, nor less than the diameter of bar.
Bottom
SECTION A-A
0.3 L1 Edge
Beam RC Slab No negative
reinforcement
Intermediate
Beam
0.3 L3 L3 Edge
Intermediate Bottom Beam
Beam Distribution
Bottom Bar
Main Bars
L4 Longer Direction (L2) L4 L2
Top negative
(L2 >2L1) reinforcement
over support
PLAN SECTION B-B
REINFORCEMENT DETAILING
Two - Way Slab
(When ratio of longer span to shorter span of slab is less than 2)
Bottom 0.1 L1
Distribution
Bars
L3
Intermediate Bottom Beam
Beam Bottom Distribution Bar
Main Bars
L4 L2
SECTION D-D
L4 Longer Direction (L2) Rebar Top
(L2 < 2L1 ) Chair Reinforcement
PLAN
Distribution
Reinforcement
Top Reinforcement
Approx RC Slab t t-70mm
60 times Minimum
the bar L/7 75 mm 100mm
diameter
L/3 RC Cantilever
RC Beam Slab 10 mm f bar Bottom
L Reinforcement
Symmetrical Walls
Ø Provide more-or-less symmetrical walls in both
the directions of the plan.
Vertical Continuity
Ø Walls should be continuous in elevation upto
Foundation
Plan Dimensions
Ø Length to width ratio of the plan should be less
than 4.
Masonry Bond
Ø Flemish bond is preferred as compared to english
or any other bond.