LeadingLEDApplications

N Series User Manual


N3/N4/N4W/N5

Slim & High Grayscale Front & Rear Intelligent Monitor


Easy Maintenance Fast Installation
Light Weight Servicing
Leading LED Applications

Table of Contents

Safety Information 02-03

Product Introduction 04

About N Series 04

Product Dimensions 05

Product Specifications 06

Product Value Features 07

Product Components 08

Cabinet Introduction 08

Product Structure / Electronic Components Details 08-10

Product Installation 11

Front Installation / Rear Installation 11

Floor Installation 12

Use Sub-frame for Fast Installation 12

Wall-mounting Solution 13

Front Installation Instructions (Wall-mounting) 13-14

Product Wiring 15

Power Supply Wiring 15

Power Cable Wiring 16

Network Cable Wiring 16

Maintenance 17

Preparation Tools 17

Module Front & Rear Maintenance 18

Check for Power Supply Short Circuit 18

- 01 - N Series User Manual


Leading LED Applications

Safety Information

WARNING!
Please read the Safety Measures listed in this section carefully before
installing, switching on, operating and maintenance of this product.

The following marks on the product and in this manual indicate important safety measures.

WARNING! WARNING! WARNING! WARNING! WARNING! WARNING!


Safety Risk! Please read the Dangerous Voltage! Hot Surface! Flammable! Possible damage
Might cause manual before Might cause Do not touch. to eyes.
equipment damage operating. equipment damage
Or safety risk. or electric shock.

WARNING: Be sure to understand and follow all safety guidelines, safety instructions, warnings and
precautions listed in this manual.
This product is for professionals use only!
This product may result in serious injury or death due to fire hazard, electric shock or on dropping.

Please read this manual carefully before installing, powering up, operating and maintenance of this
product.
Follow safety instructions in this manual and on the product. If you have any questions, please seek
help from Absen.

Beware of Electric Shock!


• To prevent electric shock the device must be properly grounded during installation. Do not ignore
using the grounding plug, or else there is a risk of electric shock.
• During a lightning storm, please disconnect the device’s power supply, or provide other suitable
lightning protection. If the equipment is not in use for a long time, please unplug the power cord.
• When performing any installation or maintenance work (e.g. removing the fuses, etc.,) make sure to
turn off the master switch.
• Disconnect AC power when the product is not in use, or before disassembling, or installing the
product.
• The AC power used in this product must comply with local building and electrical codes, and should
be equipped with overload and ground fault protection.
• The main power switch should be installed at a location near the product and should be clearly
visible and easily reached. This way in case of any failure the power can be promptly disconnected.
• Before using this product check all electrical distribution equipment, cables and all connected
devices, and make sure all meet current requirements.
• Use appropriate power cords. Please select the appropriate power cord according to the required
power and current capacity, and ensure the power cord is not damaged, aged or wet. If any
overheating occurs, replace power cord immediately.
• For any other questions, please consult a professional.

N Series User Manual - 02 -


Leading LED Applications

Beware of Fire!
• Use a circuit breaker or fuse protection to avoid fire caused by power supply cables overloading.
• To avoid fire caused by power supply cables overloading, do not connect to the same power supply
point for more than 8 cabinets(N4W 6 cabinets) at a voltage of 100-120V, or 16 cabinets(N4W 12
cabinets) at a voltage of 200-240V.
• Maintain good ventilation around the display screen, controller, power supply and other devices, and
keep a minimum 0.1 meter gap with other objects.
• Do not stick or hang anything on the screen.
• Do not modify the product, do not add or remove parts.
• Do not use the product in case ambient temperature is over 40℃.

Beware of Injury!
• Warning: Wear a helmet to avoid injury.
• Ensure any structures used to support, fix and connect the equipment can withstand at least 10
times the weight of all the equipment.
• When stacking products, please hold products firmly to prevent tipping or falling.
• Ensure all components and steel frames are securely installed.
• When installing, repairing, or moving the product, ensure the working area is free of obstacles, and
ensure the working platform is securely and stably fixed.
• In the absence of proper eye protection, please do not look directly at the lit screen from within a 1
meter distance.
• Do not use any optical devices that have converging functions to look at the screen to avoid burning
the eyes.

WARNING: Beware of suspended loads.

LED lamps used in the module are sensitive and can be damaged by ESD (electrostatic discharge).
To prevent damage to LED lamps, do not touch when the device is running or switched off.

WARNING: The manufacturer shall not bear any responsibility for any incorrect, inappropriate,
irresponsible or unsafe system installation.

Product Disposal
• Any component that has a recycling bin label can be recycled.
• For more information on collecting, reusing and recycling, please contact the local or regional waste
management unit.
• Please contact us directly for detailed environmental performance information.

- 03 - N Series User Manual


Leading LED Applications

Product Introduction

About N Series
N3/N4/N4W/N5 are indoor fixed mounted high-definition display with unique competitive advantages. Designed in a long
rectangle shape with full aluminum structure, it looks like a tablet. Its cabinets are light and thin, only 8.8kg/cabinet(N4W
9.2kg), and only 54mm thickness. The thin cabinets are made of aluminum, use magnetic modules, support complete
front and rear installation and complete front and rear maintenance, and don’t require a maintenance channel.
The product is equipped with smart monitoring system, and uses a fan-less design for cabinet and power supply,
ensuring it is super-quiet, with exceptional heat dissipation. It features highly flat and smooth display plane, precision
cabinet and module assembly, and very strong structure. Standard Cabinet Dimension is: 1152X288X54mm.
The product is primarily used at hotel ballrooms, TV stations, commercial chain stores, branded snack stores, transpor-
tation hubs, supermarkets, banks, churches, airports, railway stations, theaters, company lobbies, high-end clubhouses,
museums, large conference rooms, and for various other applications.
Nowadays, with the LED display industry becoming severely standardized, N Series stands out among all similar
products with its delicate appearance, thin and light structure, excellent display effect, full-featured functions, easy
maintenance, smart monitoring and other unique advantages, providing good business opportunities for capable and
influential contractors, service providers and advertisers.

Front

Rear

N Series User Manual - 04 -


Leading LED Applications

Product Dimensions

1152mm 54mm

288mm
LED

Cabinet Dimension

288mm
288mm

Module Dimension

- 05 - N Series User Manual


Leading LED Applications

Product Specifications

Technical Specifications N3 N4 N4W N5

Pixel Configuration SMD 2121 SMD 2121 SMD 1921 SMD 2121

Pixel Pitch (mm) 3.2 4 4 5.14

Pixel Matrix per Cabinet 360×90 288×72 288×72 224×56

Physical Module Size (L×W) / (mm) 288×288 288×288 288×288 288×288


Parameters Cabinet Weight (kg) 8.8 8.8 9.2 8.8

Cabinet Material Aluminum

Cabinet Dimension (L×W×H) / (mm) 1152×288×54

Color Grayscale (Bit) 16

Grey Scale per Color (Level) 65536

Electronic Refresh Rate (Hz) 1920


Parameters Frame Frequency (Hz) 50/60

Signal Transmission Distance UTP cable: <100 m; Single-mode fiber: <10 km

Drive Mode 1/15 1/12 1/12 1/7

Brightness (cd/m2) 1000 1000 4000 1000

Color Temperature (K) 7500 7500 7500 7500


Optical
Contrast Rate 2000:1 3000:1 3800:1 3000:1
Parameters
Horizontal Viewing Angle (°) 160

Vertical Viewing Angle (°) 140

AC Input Voltage (V) 100~240

Electrical AC Input Frequency (Hz) 50/60


Parameters
Maximum AC Input Power (W/m2) 450 450 540 450
2
Average AC Input Power (W/m ) 150 150 180 150

Storage Temperature (℃) -40~+60℃

Working Temperature (℃) -10~+40℃


Environmental Storage Humidity (RH) 10%~90% non-condensing
Parameters
Working Humidity (RH) 10%~90% non-condensing

IP Rating (Front/Rear) IP50/IP51

Typical Life (hrs) 100,000


Product
Cabinet Installation Method Fixed Installation
Installation

N Series User Manual - 06 -


Leading LED Applications

Product Value Features

• Stylish and sophisticated appearance. Looks like a tablet, and the rectangular appearance makes it easy to change
dimensions.

• Light and thin product. Cabinet dimension 1152x288mm, weighs only 8.8kg/cabinet(N4W 9.2kg), with only 54mm
thickness, with more than 25% reduction in weight and over 35% reduction in thickness compared to similar products in
the market.

• Brand new smart monitoring. Monitoring card not required to monitor signal receiving cards, modules, cables, tempera-
ture, LED, etc. A breakthrough from traditional architecture, reducing wiring and failure points.

• Supports PCs, tablets, mobile phones and other smart terminals to connect to the display for monitoring screen
operation.

• Smart Modules: Module can store ID number, production date, order information, usage duration, color coordinates,
current and other information. More convenient and practical.

• Complete front or rear maintenance. Perfect for environments where only rear maintenance is available like window
display, but also perfect for environments where only front maintenance is allowed, such as wall mounted installation at
malls.

• Complete front installation and maintenance can be adopted for wall-mounted installation, with magnetic modules,
power supply, signal receiving card, HUB, cable wirings, etc., accessible from the front, ensuring easy and fast
servicing, and zero maintenance channel requirement.

• Magnetic modules enable fast and convenient module installation and disassembly without screws.

• Cabinets can be installed both horizontally and vertically. The module can be rotated along with cabinets by 90 degrees
for assembly (rotating the module and cabinet together does not affect the viewing angle), ensuring the screen can be
installed vertically, to meet customers’ different installation requirements.

• Sub-frame enables faster installation.

• Fan-less design for cabinets and power supply, eliminating noise and reducing power consumption. More energy
savings.

• Uses crystal head sockets and reliable power plug sockets for signal and power cable connections between cabinets
and signal source, and power plug and socket, for faster and safer connections.

• Easy cabinet testing and operating status monitoring with external test button and indicators.

• High definition ensures excellent and super clear display effect. No ghost shadows or caterpillar problems, with high
grayscale, high refresh rate, and high grayscale at low brightness, highlighting exceptional display affect.

• Super large viewing angle, high contrast ratio: 160/140 no dark spots phenomenon. Uses TOP type SMD LED,
combined with light trap mask design, ensuring excellent optical effects.

• Supports Absen’s 3rd Generation Pixel-by-Pixel Correction (A3C) technology, ensuring even images. Different batches
produced within one year can be mixed and used together. Module is designed with built-in data correction memory, so
that users can directly replace modules without cumbersome setup, and can easily import and calibrate data.

- 07 - N Series User Manual


Leading LED Applications

Product Components

Cabinet Introduction

Positioning Column

Power output Mounting holes


Test button
Signal Input/Output
Indicator

Power input

Product Structure / Electronic Components Details


Product structure consists of two parts: Cabinet and module.

Cabinet structure: Full aluminum cabinet is extremely thin and light. Cabinet can be installed either horizon-
tally or vertically.

Horizontal Installation

Vertical Installation

N Series User Manual - 08 -


Leading LED Applications

Modular structure: Magnetic modules. Relative to the cabinet structure, modules can be rotated by 90
degrees for installation, so that the cabinet can be installed vertically or horizontally. When installed
vertically, the module needs to be rotated by 90 degrees, so as not to affect left and right viewing angle.

30.6mm 287.7mm
16.1mm

287.7mm
87
°

Up and down signal cable, 0.3m length:

Left and right signal cable, 1.5m length:

Up and down power cable, 0.3m length:

N
L
E
L N

Screen long power cable, 10m length:

L
L E
N
N

- 09 - N Series User Manual


Leading LED Applications

Packaging

1218.0mm
324.0mm

4-in-1 Carton Packing Wooden Case Packing

Installation-use connecting plates and mounting bolts

100mm
100mm
70mm

74mm
4mm

Connecting Plates M8x60 Bolts

N Series User Manual - 10 -


Leading LED Applications

Product Installation
Various installation methods are available for this product: front installation, rear installation, floor installa-
tion, using sub-frame for fast installation, as well as wall-mounted installation.

Front Installation

Remove modules M6X60 bolt fixed


from both sides module Front Installation Hole on steel structure

Module Module

Remove the modules from left and right sides of the cabinet, use M6x60 bolt at the front mounting holes to
fix it to the steel structure. After it is fixed properly, connect power cord and signal lines, and then restore
the removed modules.

Rear Installation

Connecting Plates M8X60 Bolt

Steel construction
40X40 square hollow bars

Use M8x60 bolts and connecting plates to fix onto the 40X40 square hollow bars.

- 11 - N Series User Manual


Leading LED Applications

Floor Installation

A floor support stand is required for floor installation, so that cabinets can be mounted onto the support
stand.

Use Sub-frame for fast installation

Front installation hole

Sub-frame Rear installation hole

When installing, first fix 4 (2 to 4) cabinets onto the sub-frame, and then mount the sub-frame onto the steel
structure or wall, to achieve fast installation.
Note: Front or rear installation can also be used for sub-frame installation.

N Series User Manual - 12 -


Leading LED Applications

Wall-mounting Solution

Wall Wall mounting device

Install cabinets onto the sub-frame or fixed structure, and then directly mount the sub-frame onto the wall,
to achieve wall-mounting installation.

Front Installation Instructions (Wall-mounting)

Step 1:
Install cabinets onto the sub-frame and splice 2 to 4 cabinets. Number of cabinets is based on actual
requirements at installation site.

Sub-frame

Sub-frame

Front installation hole

- 13 - N Series User Manual


Leading LED Applications

Step 2: Step 3:
Take a properly spliced cabinet, remove modules According to the installation positions marked on
from four corners, mark installation positions on the the wall, install M10 expansion screws.
wall according to the mounting holes on the
sub-frame.

Sub-frame Wall

M10 Expansion
screws

Module

Installation
hole

Mark

Step 4: Step 5:
Install the cabinet: Mount cabinets onto the wall After wiring is completed, insert modules back at
corresponding to the M10 expansion screw positions, the four empty corners. Repeat the same proce-
and then lock M10 nut (flat cushion + spring washers) dures to install the next spliced cabinet.

M10 nut (flat cushion


+ spring washers)

Cabinet installation is completed with sub-frame

N Series User Manual - 14 -


Leading LED Applications

Product Wiring

Power Supply Wiring

• Preparation before wiring


Before connecting to power supply and switching on control signal to the entire screen, please carefully
check the power supply and signal cable connections. Please carefully check the "L" line, "N" line and "PE" of
each cabinet’s AC inlet, and ensure there is no short circuit between the three lines (Use multimeter to
measure).

• Power Supply Cabling Instructions


Please calculate and select the power distribution box or socket type based on 450 w/m2 (N4W 540w/m 2 )
maximum power consumption. Please consult your power distribution box manufacturer to specifically match.
Cabinet’s input voltage is 100-240V/AC, and 3X1.5m m2 power cable is used to connect from distribution box
to cabinet. When input voltage is 220V, each power supply can be used to supply power for maximum 16
cabinets. When the input voltage is 110V, each power supply can be used to supply power for maximum 8
cabinets.

• Cabinet terminal connection diagram

Signal interfaces,
no difference for input and output

Indicators: Green is signal indicator,


Red is power indicator Cabinet self-test button

Power female plug, Power male plug,


power output power input

Take 2x4 cabinets for example; following are the instructions for power and signal cable connection method:

- 15 - N Series User Manual


Leading LED Applications

Power Cable Wiring

Total power for 8 cabinets with size 1152x288mm each is: 8x1.152x0.288x450w=1.2kw, arranged in 2x4
with 2 cabinet columns, and 4 cabinets for each column connected to power supply in series. In this case
use a 3X1.5m m2 power cable to connect from the distribution box or socket to the bottom of the cabinet.

Network Cable Wiring

The network cable is connected from up to down in "S" shape. Please calculate the resolution as per
288x72 pixels for each cabinet, and connect signal cables in accordance with the Signal Sending Card’s
load range. Please note that the load pixel range for each network interface is not more than 650,000
pixels.

Power Cable

Signal Cable

Signal Sending Box Laptop

DVI or HDMI plug

USB plug

N Series User Manual - 16 -


Leading LED Applications

Maintenance

Preparation Tools

• Tools: front maintenance tools, multimeter, screwdriver etc.

Front Maintenance Tools Multimeter

Screwdriver

- 17 - N Series User Manual


Leading LED Applications

Module Front & Rear Maintenance

• Module Front Maintenance

• Module Rear Maintenance

Back cover screws

Check for Power Supply Short Circuit

After completing the cabinet wiring, please use a multimeter to check if there is any short circuit at the AC
input power supply (L / N / PE) and DC output terminal (VCC / GND). If there is a short circuit, please
carefully investigate the wirings. Make sure all wirings are normal, and only then connect power to operate
the unit.

N Series User Manual - 18 -


V2.0 Nov. 2015
All rights reserved by Shenzhen Absen Optoelectronic Co., Ltd.
Shenzhen Absen Optoelectronic Co., Ltd. reserves the rights to modify contents without any further notice.

Shenzhen Absen Optoelectronic Co., Ltd. Absen American Inc. Absen GmbH
Absen Building, Huawei Industrial Park, Bantian, 7703, Kingspointe Parkway, Suite 600, Orlando, Eisenstrasse 5, 65428 Russelsheim (Frankfurt),
Longgang District, Shenzhen 518129, P.R.China FL 32819 Germany
T: +86-755-89747399 E: absen@absen.com T: +1-407-203-8870 E: stella.hsia@absen.com T: +49 (0) 6142 920 87 56 E: europe@absen.com
F: +86-755-89747599 W: www.absen.com F: +1-407-203-8873 W: www.absen.com F: +49 (0) 6142 920 87 57 W: www.absen.com

You might also like