This document provides tables listing diagnostic warning messages, error messages, and command messages for an HMV drive system. Table 10-1 lists initialization and operating states. Tables 10-2 and 10-3 list diagnostic warning and error messages respectively, identified by display, number, and description. The document directs the reader to firmware documentation for detailed descriptions of causes and remedies for the diagnostic message numbers.
This document provides tables listing diagnostic warning messages, error messages, and command messages for an HMV drive system. Table 10-1 lists initialization and operating states. Tables 10-2 and 10-3 list diagnostic warning and error messages respectively, identified by display, number, and description. The document directs the reader to firmware documentation for detailed descriptions of causes and remedies for the diagnostic message numbers.
This document provides tables listing diagnostic warning messages, error messages, and command messages for an HMV drive system. Table 10-1 lists initialization and operating states. Tables 10-2 and 10-3 list diagnostic warning and error messages respectively, identified by display, number, and description. The document directs the reader to firmware documentation for detailed descriptions of causes and remedies for the diagnostic message numbers.
332/417 IndraDrive Supply Units, Power Sections HMV, HMS, HMD,
HCS02, HCS03 Commissioning, operation and diagnostics
Display Number Diagnostics
VM bb A0013 Ready for power on VM A0500 Supply module in voltage control VM A0502 Supply module in operation VM A0503 DC bus charging active VM A0520 DC bus quick discharge active VM A0800 Unknown operating mode
Tab. 10-1: Initialization and operating states of HMV
HMV - Diagnostic warning messages
For the detailed descriptions of the causes and remedies relating
to the listed "diagnostic message numbers", see the description of diagnostic messages of the firmware documentation.
Display Number Diagnostics
VM E2026 E2026 Undervoltage in power section
VM E2050 E2050 Device overtemp. Prewarning VM E2061 E2061 Device overload prewarning VM E2810 E2810 Drive system not ready for operation VM E2818 E2818 Phase failure VM E2819 E2819 Mains failure VM E2820 E2820 Braking resistor overload prewarning VM E8025 E8025 Overvoltage in power section VM E8026 E8026 Undervoltage in power section VM E8057 E8057 Device overload, current limit active VM E8802 E8802 PLL is not synchronized VM E8814 E8814 Undervoltage in mains VM E8815 E8815 Overvoltage in mains VM E8818 E8818 Phase failure VM E8819 E8819 Mains failure
Tab. 10-2: Diagnostic warning messages of HMV
HMV - Diagnostic error messages
For the detailed descriptions of the causes and remedies relating
to the listed "diagnostic message numbers", see the description of diagnostic messages of the firmware documentation.
Display Number Diagnostics
VM PL F2009 PL Load parameter default values
VM F2018 F2018 Device overtemperature shutdown
Bosch Rexroth AG R911318790_Edition 05
IndraDrive Supply Units, Power Sections HMV, HMS, HMD, 333/417 HCS02, HCS03 Commissioning, operation and diagnostics
Display Number Diagnostics
VM F2022 F2022 Device temperature monitor defective VM F2026 F2026 Undervoltage in power section VM F2077 F2077 Current measurement trim wrong VM F2087 F2087 Module group communication error VM F2110 F2110 Error in non-cyclical data communic. of power section VM F2802 F2802 PLL is not synchronized VM F2814 F2814 Undervoltage in mains VM F2815 F2815 Overvoltage in mains VM F2816 F2816 Softstart fault power supply unit VM F2817 F2817 Overvoltage in power section VM F2818 F2818 Phase failure VM F2819 F2819 Mains failure VM F2820 F2820 Braking resistor overload VM F2821 F2821 Error in control of braking resistor VM F2833 F2833 Ground fault in motor line VM F2834 F2834 Contactor control error VM F2835 F2835 Mains contactor wiring error VM F2836 F2836 DC bus balancing monitor error VM F2837 F2837 Contactor monitoring error VM F2840 F2840 Error supply shutdown VM F2860 F2860 Overcurrent in mains-side power section VM F2890 F2890 Invalid device code VM F2891 F2891 Incorrect interrupt timing VM F2892 F2892 Hardware variant not supported VM F8057 F8057 Device overload shutdown VM F8069 F8069 +/-15Volt DC error VM F8070 F8070 +24Volt DC error VM F8813 F8813 Connection error mains choke VM F9001 F9001 Error internal function call VM F9003 F9003 Watchdog VM F9004 F9004 Hardware trap
Tab. 10-3: Diagnostic error messages of HMV
HMV - Diagnostic command messages
For the detailed descriptions of the listed diagnostic displays see
the description of diagnostic messages of the firmware documentation.
Troubleshooting Servo Alarm 414" is 38 characters long and indicates the key topic of troubleshooting for the specific servo alarm 414 discussed in the document. It starts with "TITLE