You are on page 1of 2

332/417 IndraDrive Supply Units, Power Sections HMV, HMS, HMD,

HCS02, HCS03
Commissioning, operation and diagnostics

Display Number Diagnostics


VM bb A0013 Ready for power on
VM A0500 Supply module in voltage control
VM A0502 Supply module in operation
VM A0503 DC bus charging active
VM A0520 DC bus quick discharge active
VM A0800 Unknown operating mode

Tab. 10-1: Initialization and operating states of HMV


HMV - Diagnostic warning messages

For the detailed descriptions of the causes and remedies relating


to the listed "diagnostic message numbers", see the description of
diagnostic messages of the firmware documentation.

Display Number Diagnostics

VM E2026 E2026 Undervoltage in power section


VM E2050 E2050 Device overtemp. Prewarning
VM E2061 E2061 Device overload prewarning
VM E2810 E2810 Drive system not ready for operation
VM E2818 E2818 Phase failure
VM E2819 E2819 Mains failure
VM E2820 E2820 Braking resistor overload prewarning
VM E8025 E8025 Overvoltage in power section
VM E8026 E8026 Undervoltage in power section
VM E8057 E8057 Device overload, current limit active
VM E8802 E8802 PLL is not synchronized
VM E8814 E8814 Undervoltage in mains
VM E8815 E8815 Overvoltage in mains
VM E8818 E8818 Phase failure
VM E8819 E8819 Mains failure

Tab. 10-2: Diagnostic warning messages of HMV


HMV - Diagnostic error messages

For the detailed descriptions of the causes and remedies relating


to the listed "diagnostic message numbers", see the description of
diagnostic messages of the firmware documentation.

Display Number Diagnostics

VM PL F2009 PL Load parameter default values


VM F2018 F2018 Device overtemperature shutdown

Bosch Rexroth AG R911318790_Edition 05


IndraDrive Supply Units, Power Sections HMV, HMS, HMD, 333/417
HCS02, HCS03
Commissioning, operation and diagnostics

Display Number Diagnostics


VM F2022 F2022 Device temperature monitor defective
VM F2026 F2026 Undervoltage in power section
VM F2077 F2077 Current measurement trim wrong
VM F2087 F2087 Module group communication error
VM F2110 F2110 Error in non-cyclical data communic. of power section
VM F2802 F2802 PLL is not synchronized
VM F2814 F2814 Undervoltage in mains
VM F2815 F2815 Overvoltage in mains
VM F2816 F2816 Softstart fault power supply unit
VM F2817 F2817 Overvoltage in power section
VM F2818 F2818 Phase failure
VM F2819 F2819 Mains failure
VM F2820 F2820 Braking resistor overload
VM F2821 F2821 Error in control of braking resistor
VM F2833 F2833 Ground fault in motor line
VM F2834 F2834 Contactor control error
VM F2835 F2835 Mains contactor wiring error
VM F2836 F2836 DC bus balancing monitor error
VM F2837 F2837 Contactor monitoring error
VM F2840 F2840 Error supply shutdown
VM F2860 F2860 Overcurrent in mains-side power section
VM F2890 F2890 Invalid device code
VM F2891 F2891 Incorrect interrupt timing
VM F2892 F2892 Hardware variant not supported
VM F8057 F8057 Device overload shutdown
VM F8069 F8069 +/-15Volt DC error
VM F8070 F8070 +24Volt DC error
VM F8813 F8813 Connection error mains choke
VM F9001 F9001 Error internal function call
VM F9003 F9003 Watchdog
VM F9004 F9004 Hardware trap

Tab. 10-3: Diagnostic error messages of HMV


HMV - Diagnostic command messages

For the detailed descriptions of the listed diagnostic displays see


the description of diagnostic messages of the firmware
documentation.

R911318790_Edition 05 Bosch Rexroth AG