You are on page 1of 15

100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader

https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

1z0-070 Dumps

Oracle Exadata X5 Administration

https://www.certleader.com/1z0-070-dumps.html

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

NEW QUESTION 1
Which two statements are true regarding the use of Auto Service Request (ASR) with an X6 Database Machine?

A. The database server ILOMs must use SMTP over the management network for notifications to ASR Manager.
B. The database server ILOMs must have SNMP traps configured to use the management network for notifications to ASR Manager.
C. The storage server ILOMs must have SNMP traps configured to use the management network for notifications to ASR Manager.
D. The database server MS process must have SNMP traps configured to use the management network for notifications to ASR Manager.

Answer: BC

Explanation: B: Database Server ILOM plug-in


Monitoring databases and their instances, ASM environments, the Grid Infrastructure, and the host software environment are done by Enterprise Manager in the
usual way as these are standard targets. But monitoring the hardware for the database servers requires the ILOM plug-in, as there is no Management Server (MS)
on the database servers to receive SNMP traps from the ILOM. The plug-in will receive sensor state and availability data from the ILOM including alerts based on
pre-set ILOM thresholds.
C: Exadata Storage Server plug-inextends the monitoring of exadata cells in addition to providing a GUI interface. The plug-in uses an SSH connection to the
cellmonitor user on the cells and uses list commands only. This is for interactive monitoring. One may also set thresholds using the plug-in which are distinct from
any thresholds set using cellcli utility as the celladmin user. For alerts to be sent to the plug-in, SNMP traps are used as follows:
Cell ILOM alerts are sent to the cell Management Server (MS) via an SNMP trap. The MS then send SNMP notifications onward to the plug-in.
Cell alerts flagged by MS itself, such as cell thresholds being exceeded, or ADR software alerts, are sent to the plug-in using SNMP.
References: https://dbatrain.wordpress.com/2011/06/
http://docs.oracle.com/cd/E21659_01/html/E21660/z40015671004046509.html

NEW QUESTION 2
Which two completely prevent a Smart Scan from occurring?

A. querying a table containing many chained rows


B. querying a table containing many migrated rows
C. performing a minimum or maximum function on an indexed column
D. performing a Fast Full Index scan on a reverse key index
E. referencing more than 255 columns form an OLTP compressed table in a query
F. querying a table containing a JSON column

Answer: BE

Explanation: B: Migrated Rows is a special case of chained rows. Migrated rows still affect performance, as they do in conventional storage situations, but with
the additional overhead of reducing the beneficial effects of “Smart Scan” in addition to increasing the number of I/Os
E: Smart Scans - broadly speaking and ignoring edge cases - can only transport a maximum of 254 columns from a single (non-HCC) segment. Requesting more
columns will simply disable Smart Scans for that segment.
An interesting limitation to Exadata Smart Scans - if more than 254 columns from a table (not HCC compressed, more on that in moment) need to be projected,
Smart Scans for that particular segment will be disabled and Exadata will fall back to conventional I/O. This means that the number of columns in the projection
clause can make a significant difference to performance, since only Smart Scans allow taking advantage of offloading and particularly avoiding I/O via Storage
Indexes.

NEW QUESTION 3
Which three statements are true concerning InfiniBand port and subnet monitoring on an X5 Database Machine?

A. The Infiniband subnet master location can be determined by using the getmaster command run on any database server.
B. The Infiniband subnet master location can be determined by using the getmaster command run on an IB switch.
C. The InfiniBand port status may be displayed on the storage servers by using the LIST IBPORT command in the CELLCLI utility.
D. The InfiniBand port status may be displayed on the Infiniband switches by using the LIST IBPORT command in the DBMCLI utility.
E. The InfiniBand port status may be displayed on the database servers by using the LIST IBPORT command in the DBMCLI utility.
F. The InfiniBand port monitoring is automatic on the database servers and is managed by Enterprise Manager.

Answer: BCE

Explanation: B: From any InfiniBand switch in the network (leaf switch or spine switch), log in as root and run the getmaster command to obtain the location of the
master SM as follows:
# getmaster
This command displays the host name or IP address and the IP address of the switch where the master SM is running.
C: CellCLI> list ibport - Will display InfiniBand configuration details
E: The DBMCLI utility is the command-line administration tool for configuring database servers, and managing objects in the server environment.
The LIST IBPORT command displays attributes for InfiniBand ports determined by the specified attributes and filters.
References: http://docs.oracle.com/cd/E80920_01/DBMMN/exadata-dbmcli.htm
https://docs.oracle.com/cd/E18476_01/doc.220/e18478/GUID-9FF8B5B0-3481-4B73-89D3-108CBD7EB989.htm

NEW QUESTION 4
Which two activities are supported on the storage servers in an Exadata X6 Database Machine?

A. Upgrading the Storage Server software package using RPM


B. Configuring secure shell user equivalency for the cellmonitor user
C. Installing an alternative package manager
D. Changing the root password
E. Upgrading a device driver for hard disks when inserting a replacement disk after a hard disk failure

Answer: AC

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

NEW QUESTION 5
Which type or types of network traffic are transported over the internal InfiniBand interconnect in Exadata Database Machine X5?

A. IDB protocol traffic, clustered ASM traffic, and clustered database instance traffic
B. IDB protocol traffic and clustered database instance traffic only
C. IDB protocol traffic and clustered ASM instance traffic only
D. Both clustered ASM and clustered database instance traffic only
E. IDB protocol traffic only

Answer: E

Explanation: Oracle Exadata uses the Intelligent Database protocol (iDB) to transfer data between Database Node and Storage Cell Node.
iDB is used to ship SQL operations down to the Exadata cells for execution and to return query result sets to the database kernel.

NEW QUESTION 6
Examine this IORM plan:

Which two are true concerning this plan?

A. The Finance database can use at least 45%, but never more than 60%, of the total Flash Cache capacity.
B. I/Os from the finance database are guaranteed to get a minimum of 45% of the I/O bandwidth if the demand exists, and a maximum of 60% of the I/O bandwidth
even if noother databases are doing I/O to the cell, and the demand from the finance database exceeds 60% of the maximum I/O rate of the cell.
C. If I/Os come from the HR database only, then they may get up to 100% of the I/O bandwidth on the cell.
D. I/Os from the finance database are guaranteed to get 45% of the I/O bandwidth if the demand is at least 60% of the maximum I/O rate of the cell, but may get
100% of the I/O bandwidth if no other databases are performing I/O to the cell.
E. If I/Os come from the HR database only, then they may get up to 10% of the I/O bandwidth on the cell.

Answer: BE

Explanation: The IORM plan can be configured using the ALTER IORMPLAN command on command- line interface (CellCLI) utility on each Exadata storage cell.
It consists of two parameters - dbplan and catplan. While the "dbplan" is used to create the I/O resource directives for the databases, the "catplan" is used to
allocate resources by workload category consolidated on the target system.
allocation/share - Specify the resource allocation to a specific database in terms of percentage or shares.
limit - Specify maximum limit of disk utilization for a database.

NEW QUESTION 7
Which two statements are true about Exadata X5 cell metrics and alerts?

A. Cell alerts on each storage server are accumulated in memory by the CELLSRV process and stored on a filesystem-based repository.
B. Cell metrics are written to disk every hour by default.
C. Cell metrics on each storage server are accumulated in memory by the CELLSRV process and written to a filesystem-based repository.
D. Cell alerts on each server are accumulated in memory by the MS process and stored on a filesystem-based repository.
E. Cell alerts are written to disk every hour by default.

Answer: BD

Explanation: Metrics are a series of measurements that are computed and retained in memory for an interval of time, and stored on a disk for a more permanent
history.
On the storage servers, the CELLSRV process provides the majority of Oracle Exadata storage services and is the primary storage software component. One of its
functions is to process, collect, and store metrics. The Management Server (MS) process receives the metrics data from CELLSRV, keeps a subset of metrics in
memory, and writes to an internal disk-based repository hourly.
References:http://www.oracle.com/technetwork/articles/servers-storage-admin/monitor-exadata-em12-2291964.html

NEW QUESTION 8

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

A file contains a script with several EXACLI commands that must be executed on each cell in an X5 full rack.
The script must run on each cell simultaneously. How would you achieve this?

A. Copy the script to all cells using the DCLI command and manually execute it on each cell using the DCLI command.
B. Copy the script to the cells using the EXACLI command and execute the script on all cells using the EXACLI command.
C. Execute it on all cells using the EXADCLI command specifying the file name containing the EXACLI script.
D. Copy the script to all cells using the CELLCLI command and execute it on all cells in parallel using the CELLCLI command.
E. Execute it on all cells using the DBMCLI command specifying the file name containing the EXACLI script.

Answer: C

Explanation: The exadcli utility runs commands on multiple remote nodes in parallel threads.
You can issue an ExaCLI command to be run on multiple remote nodes. Remote nodes are referenced by their host name or IP address. Unlike dcli, exadcli can
only execute ExaCLI commands. Other commands, for example, shell commands, cannot be executed using exadcli.
References:http://docs.oracle.com/cd/E80920_01/DBMMN/exadcli.htm#DBMMN-GUID-4AE469A6-F291-4737-B975-F1B4B91D0BA0

NEW QUESTION 9
Identify three valid reasons for creating multiple griddisks on a single harddisk-based celldisk.

A. to implement storage realms so that storage that can be reserved for specific resource consumer groups in the same database
B. to enable the creation of normal or high redundancy ASM diskgroups
C. to segregate storage into multiple pools with different performance characteristics
D. to enable disk mirroring for the system area
E. to implement storage realms so that storage can be reserved for specific databases
F. to implement storage realms so that storage that can be reserved for specific Grid Infrastructure

Answer: BCF

Explanation: Creating multiple grid disks per cell disk allows you to create multiple pools of storage on the same Exadata Storage Server. The multiple grid disks
can be assigned to separate ASM diskgroups, which can be provisioned to different databases.
Note: Griddisk is a logical disk that can be created on a celldisk. In a standard Exadata deployment we create griddisks on hard disk based celldisks only. While it
is possible to create griddisks on flashdisks, this is not a standard practice.
F: After you complete the cell configuration, you can perform the following optional steps on the storage cell:
References:https://docs.oracle.com/cd/E80920_01/SAGUG/SAGUG.pdf

NEW QUESTION 10
Which two statements are true about the X5 Exadata storage server rescue procedure?

A. The rescue procedure can be executed from the CELLBOOT USB flash drive.
B. An Exadata storage server automatically enters the rescue environment when it cannot boot from the system area.
C. The rescue procedure can be used to repair corruption in an ASM diskgroup.
D. The rescue procedure can be used to restore a corrupt system area.
E. The rescue procedure must be used to recover from a failed Exadata storage server software upgrade.

Answer: AD

Explanation: The rescue procedure is necessary when system disks fail, the operating system has a corrupt file system, or there was damage to the boot area. If
only one system disk fails, then use CellCLI commands to recover. In the rare event that both system disks fail simultaneously, you must use the Exadata Storage
Server rescue functionality provided on the Oracle Exadata Storage Server Software CELLBOOT USB flash drive.
References:http://docs.oracle.com/cd/E80920_01/DBMMN/maintaining-exadata-storage- servers.htm#GUID-710814E7-4691-49EE-95AD-726D2D6C5BFE

NEW QUESTION 10
You plan to migrate an existing production database supporting online transaction processing (OLTP) workloads to an X6 Exadata Database Machine.
The database currently supports an application requiring fast response times to satisfy stringent business requirements, and most of the application queries use
indexed access to tables.
For which two cases would you consider dropping indexes that are not used for constraints after the migration to assure that Smart Scans occur?

A. if Smart Scan performs better that any type of index scan on the corresponding table.
B. if Smart only occur instead of index skip scans on the corresponding table.
C. if Smart only occur instead of index range scans on the corresponding table.
D. if Smart Scans performs equally well to any type of index scan on the corresponding table.

Answer: AC

NEW QUESTION 15
Which two statements are true about the use of Intelligent Platform Management Interface (IPMI) on an X5 or X6 Database Machine?

A. IPMI can be used for server configuration and management on each database server.
B. The Baseboard Management Controller (BMC), which supports IPMI, runs as amultithreaded process on the storage server O/S.
C. The Baseboard Management Controller (BMC), which supports IPMI, runs as a single- threaded process on the storage server O/S.
D. IPMI can be used for server configuration and management on each storage server.

Answer: AC

Explanation: A: IPMI – short for Intelligent Platform Management Interface – is an interface standard that allows remote management of a server from another
using standardized interface. The servers in the Exadata Database Machine follow that. It’s not an Exadata command but rather a general Linux one.

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

To power on a cell or database server, issue this from another server:


# ipmitool -H prolcel01-ilom -U root chassis power on
To stop a server, use the shutdown command. To stop immediately and keep it down, i.e. not reboot, execute:# shutdown -h -y now
C: Like the KCS interface, the SSIF Interface is only specified as a ‘Single Threaded Interface’ for standard IPMI commands. That is, the BMC implementation is
not expected to process more than one IPMI request at a time. While an implementation is allowed to have a degree of ‘command queuing’, for standard IPMI
messages the SSIF lacks a ‘Seq’ field that software can use to match up particular instances of requests with responses.
References:https://www.intel.com/content/dam/www/public/us/en/documents/specification-updates/ipmi-intelligent-platform-mgt-interface-spec-2nd-gen-v2-0-spec-
update.pdf

NEW QUESTION 19
You plan to consolidate your company’s INVENTORY and SALES databases onto your new Exadata X6 Database Machine.
You are considering consolidation of all schemas into one RAC database. Which three factors would you need to consider before choosing this approach?

A. the number of database users


B. Security Policies
C. the number of database roles
D. the number of simultaneous sessions
E. the maintenance schedule

Answer: ABD

NEW QUESTION 21
Which four statements are true concerning the configuration or use of Enterprise Manager Cloud Control to monitor and manage Exadata Database Machine
components?

A. Computer nodes forward their SNMP traps to the Management Server process on the same computer node.
B. Storage nodes forward their SNMP traps to the Management Server process on the same storage node.
C. Cloud control can monitor and manage a Database Machine compute node expansion rack.
D. Oracle management agents must only be installed on one storage node in a Database Machine to enable monitoring and management of all storage nodes.
E. Cloud Control cannot monitor partitioned Exadata Database Machine systems.
F. Cloud Control can monitor and manage a Database Machine storage Expansion rack.
G. Oracle management agents must only be installed on one compute node in a Database Machine to enable monitoring and management of all compute nodes
and storage nodes.

Answer: BCFG

Explanation: B (not A): Oracle Exadata components—including database and storage servers, switches, and power distribution units (PDUs)—use SNMP to raise
alerts and report monitoring
information.
Oracle’s CellCLI interface is a Java-based framework delivered by the storage cell’s management server process (MS) that provides administrative capabilities to
your storage server entities.
C: Cloud control can monitor the Exadata Database Machine.
Figure: Oracle Enterprise Manager Cloud Control 12c monitoring architecture. Note the Management Server process (MS) on the Storage servers.

G (not D): Before using Oracle Enterprise Manager Cloud Control 12c with Oracle Exadata, an Oracle Management Agent and Oracle Exadata plug-in must be
installed on every Oracle Exadata database server (compute node). This agent monitors software targets, such as the database instances and Oracle Clusterware
resources, on the database servers. The plug-in enables monitoring of other hardware components in Oracle Exadata, including the storage servers, switches, and
power distribution units.
References:http://www.oracle.com/technetwork/articles/servers-storage-admin/monitor- exadata-em12-2291964.html

NEW QUESTION 23
Which components of an Exadata storage server image, if updated, may require that a patch also be applied to the database servers in an Exadata X6 Database
Machine?

A. Linux operating system on the storage server


B. InfiniBand HCA firmware on the storage server
C. Storage server hard disk device drivers
D. Storage server flash device drivers

Answer: D

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

Explanation: Exadata patches are intended for and include fixes for both the storage servers and Compute servers, and optionally InfiniBand switches.
Patching order
You should patch the Exadata Database Machines in the following sequence
References: https://www.toadworld.com/platforms/oracle/w/wiki/11640.oracle-exadata- patching

NEW QUESTION 24
Which two statements are true about data paths used during RMAN backup and restore operations when media management servers use InfiniBand to connect to
an X5 Database Machine?

A. During backups, data blocks are always read from Smart Flash Cache by cellsrv.
B. During restores, data blocks read from the media are sent to a database server that sends the blocks to cellsrv to be written.
C. During backups, data blocks are read by cellsrv and sent to a database server, which sends the blocks to the media manager to be written to media.
D. During backups, data blocks are read by cellsrv and sent directly to the media manager to be written to media.
E. During restores, data blocks read from the media are sent directly to cellsrv to be written.

Answer: DE

Explanation: The fastest database backup is achieved via InfiniBand.


RMAN does not back up directly to tape. However, it will integrate with media management software such as Oracle Secure Backup and utilize their capabilities to
manage tape libraries.
Exadata Database Machine: The Database Machine contains the databases that need to
be backed up. Oracle RMAN is the only mechanism to back up the databases that utilize Exadata Storage Servers as the storage. RMAN processes run on the
database servers and interact with the Oracle Secure Backup (OSB) agent, which further interacts with the media management software and enables RMAN to
communicate with the tape library.
References:http://apprize.info/data/oracle_4/6.html

NEW QUESTION 29
Which four statements are true about the configuration of Auto Service Request (ASR) for use with an X5 Database Machine?

A. ASR Manager software may be installed on one of the database servers in the Database Machine.
B. ASR can connect to the Internet using Simple Network Management Protocol (SNMP), using a proxy server.
C. ASR Manager can connect to the Internet directly with HTTPS.
D. ASR Manager can connect to the Internet with HTTPS using a proxy server.
E. ASR can connect to the Internet directly using Simple Network Management Protocol (SNMP).
F. ASR Manager software may be installed on a server that is not part of the Database Machine.

Answer: ACDF

Explanation: C: If you need to use HTTPS for security purposes, you can set up HTTPS/SSL for the ASR Manager HTTP receiver.
D: As part of the registration process for ASR Manager, you can optionally set the ASR Manager to access the internet through a proxy server.
References:https://docs.oracle.com/cd/E37710_01/install.41/e18475/ch2_asr_manager.ht m#ASRUD137

NEW QUESTION 32
Which three must be true for a Smart Scan to occur for a table?

A. cell_offload_processing must be true in sessions issuing SQL statements that access the table.
B. The query must be executed serially.
C. The query must be executed in parallel.
D. Direct path reads must be used at run time.
E. The ASM diskgroup containing the table’s tablespace must have a 4 Mbyte AU size.
F. The ASM diskgroup containing the table’s tablespace must have cell.smart_scan_capable set to true.

Answer: ADF

Explanation: A: pt_param( ‘cell_offload_processing’ ’TRUE’) hint is used to enable the exadata smart scan feature in sql execution process.
D: Direct reads bypass the buffer cache and go directly into the process PGA. Cell offload operations occur for direct reads only.
F: The cell.smart_scan_capable attribute must be set to TRUE.

NEW QUESTION 37
Which three statements are true about the CELLCLI command?

A. It can execute commands on multiple storage servers in parallel.


B. It has command-line history.
C. It requires root privileges to create CELLDISKS and GRIDDISKS.
D. It can be executed on storage servers.
E. It can be executed using the DCLI utility.

Answer: BDE

Explanation: The CellCLI utility supports command-line history.


Each Exadata Storage cell can be monitored, configured, and maintained using the cellcli command line interface.
The dcli utility facilitates centralized management across an Oracle Exadata Storage Server Software realm by automating the execution of CellCLI commands on
a set of cells and returning the output to the centralized management location where the dcli utility was run.
References:http://docs.oracle.com/cd/E80920_01/SAGUG/exadata-storage-server- cellcli.htm

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

NEW QUESTION 39
Which three are true concerning Exadata Smart Flash Cache on X6 Database Machines with High Capacity Storage Servers?

A. The “keep” cache is limited to a maximum of 80% of the total Smart Flash Cache capacity.
B. Smart Scan will always use the Smart Flash Cache for all I/Os fast full index capacity.
C. Smart Scan will always use the Smart Flash Cache for all I/Os for full table scans.
D. Single block reads can benefit from Smart Flash Cache.
E. Multiblock reads can benefit from Smart Flash Cache.

Answer: BDE

Explanation: D: By default Exadata stores only small I/Os in the Exadata Smart Flash Cache. Small I/Os in most cases are single-block reads. During a full table
scan Oracle requests blocks in multiblock lumps (by default 16 blocks), and these are

NEW QUESTION 41
The InfiniBand switches on your X5 Database Machine contain the software version as confirmed using the version command:
[root@exampsw –ib2 bin] # version SUN DCS 36p version: 1.3.3-2 Build time: Apr 4 2015 11:15:19
SP board info:
Manufacturing Date: 2014.05.05 Serial Number: “NCD3X0178” Hardware Revision: 0x0006 Firmware Revision: 0x0102 BIOS version: NOW1R112 BIOS date:
04/24/2014
Which two tools are useful for monitoring the InfiniBand switches for fan problems and by which users should they be run?

A. Run the env_test command on the switches after logging in as the ilom-admin user.
B. Run the getfanspeed command on the switches after logging in as root.
C. Run the env_test command on the switches after logging in as root.
D. Run the showtemps command on the switches after logging in as the ilom-admin user.

Answer: CD

Explanation: C: Login as root on IB switch and run,


# env_test
Example output include:
Starting FAN test: Fan 0 not present
WARNING Fan 1 running slow rpm 5450 limit 6440
WARNING Fan 2 running slow rpm 5341 limit 6440
WARNING Fan 3 running slow rpm 5341 limit 6440
D: The showtemps command displays internal temperatures for the switch.
The following example shows how to display switch temperatures with the showtemps command.
# showtemps
Back temperature 29
Front temperature 30
SP temperature 36
Switch temperature 52, maxtemperature 56 All temperatures OK
#
References:http://myoraclediary.blogspot.se/2014/04/all-about-infiniband-switches-on- exadata.html

NEW QUESTION 45
Which three statements are true about Recovery Manager (RMAN) daily differential incremental backup strategies on an X5 Database Machine for a database
having 25% or more of its blocks modified each day and which has an 8 k block size?

A. Fast incremental backups when 50% or more of the blocks have changed since the last backup, will run as slowly as normal incremental backup.
B. Enabling Block Change Tracking (BCT) on the database can result in reduced consumption of storage network bandwidth.
C. Enabling Block Change Tracking (BCT) on the database can result in a reduction ofphysical I/O on the cells during incremental backups.
D. For level-1 backups, Block Change Tracking (BCT) is most beneficial when more than 25 percent of the blocks have changed since the last backup.
E. For level-0 backups, Block Change Tracking (BCT) is most beneficial when more than 25 percent of the blocks have changed since the last backup.
F. cellsrv returns only blocks that have changed since the last backup.

Answer: ACF

Explanation: A: Fast Incremental backups is possible with Block change tracking, which is initially introduced from version 10.2 onwards, by this tool it's very
useful to reduce the RMAN incremental backup duration.
If the changes are something around 20% then in this situation BCT helps a lot.
C: Exadata Storage Server offload capability combined with RMAN block change tracking will efficiently perform large I/Os at the storage-tier level, returning only
individual changed blocks for incremental backups and increasing the backup performance of the system.
Note: Level 1 backup: A level 1 backup includes only those blocks that have been changed since the "parent" backup was taken. Remember a parent backup may
be either a level 0 or a level 1 backup.
Block change tracking allows indeed the highest benefit for databases where the changes are not so high,
Level 0 backup: A level 0 incremental backup is physically identical to a full backup and it includes every data block in the file except empty blocks. The only
difference is that the level 0 backup is recorded as an incremental backup in the RMAN repository, so it can be used as the parent for a level 1 backup.
References:http://www.dba-oracle.com/t_rman_backup_types.htm http://www.oracle.com/technetwork/database/availability/maa-tech-wp-sundbm-backup-
11202-183503.pdf
https://www.toadworld.com/platforms/oracle/w/wiki/11124.fast-incremental-backups-active- data-guard

NEW QUESTION 50
Which four are true about Exadata features?

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

A. Storage Indexes persist across Exadata storage server reboots.


B. Data Warehouse workloads will benefit from Smart Flash Cache configured in Write- Through mode.
C. Hybrid Columnar Compressed tables can be compressed and decompressed on Exadata storage servers.
D. Hybrid Columnar Compressed tables can be compressed and decompressed on the database servers.
E. OLTP workloads will benefit from Smart Flash Cache configured in Write-Back mode.
F. Storage Indexes persist across database server reboots.

Answer: CDEF

Explanation: CD: That data remains compressed not only on disk, but also remains compressed in the Exadata Smart Flash Cache, on Infiniband, in the
database server buffer cache, as well as when doing back-ups or logshipping to Data Guard.
E (not B): Use the Write-Back Flash Cache feature to leverage the Exadata Flash hardware and make Exadata Database Machine a faster system for Oracle
Database Deployments. Write-through cache mode is slower than write-back cache mode. However, write-back
cache mode has a risk of data loss if the Exadata Storage Server loses power or fails.
F: Storage indexes are not stored on disk; they are resident in the memory of the storage cell servers.

NEW QUESTION 51
Which three statements are true about the EXADCLI utility?

A. It may be run interactively.


B. It can be used to execute EXACLI scripts on multiple storage servers in parallel.
C. It can be used to execute O/S commands on multiple storage servers in parallel.
D. It can be used to execute EXACLI commands on multiple storage servers in parallel.
E. It uses the same security mechanism as the EXACLI command.
F. It may be used to execute DBMCLI commands on multiple database nodes in parallel.

Answer: DEF

Explanation: The exadcli utility runs commands on multiple remote nodes in parallel threads.
You can issue an ExaCLI command to be run on multiple remote nodes. Remote nodes are referenced by their host name or IP address. Unlike dcli, exadcli can
only execute ExaCLI commands. Other commands, for example, shell commands, cannot be executed using exadcli.

NEW QUESTION 55
You plan to consolidate multiple mission-critical databases onto a single rack Exadata X6
database Machine.
You do not plan to use virtualization on the database servers.
You have identified two database categories, based on differing availability and maintenance objectives.
Which two choices will be the best solution?

A. Create a single database cluster that accesses a single storage grid.


B. Create a single database cluster that accesses multiple storage grids.
C. Partition the Exadata storage servers into two separate storage grids.
D. Create a single storage grid and share space on the celldisks using Exadata storage realms.
E. Partition the database servers into two separate clusters.

Answer: BE

NEW QUESTION 57
Which three are true concerning Exadata snapshot databases?

A. They are supported on non-container databases.


B. They are based on a read-write copy of an existing database.
C. They are integrated with the Multitenant architecture.
D. They can be created only on sparse ASM disk groups.
E. They don’t support all Exadata features.
F. They can be created on any type of ASM disk group.

Answer: ACD

Explanation: A: An Exadata snapshot database can be either a non-container database (non-CDB) or a container database (CDB). Creating an Exadata snapshot
database of a CDB enables access to all of the pluggable databases in that container.
C: You can create two types of Exadata snapshots, depending on the current setup of your environment:
D: SPARSE disk group based database snapshots is functionality included in Exadata Storage Software. It requires Exadata Storage Software version 12.1.2.1.0
and Oracle Database 12c version 12.1.0.2 with bundle patch 5 or later. This feature is designed to work on native Exadata ASM storage disk groups. It uses ASM
SPARSE grid disk based thin provisioning where snapshot databases created on a SPARSE disk group need only the space for changes plus some metadata,
thereby enabling storage efficient snapshot databases.
References:
http://docs.oracle.com/cd/E80920_01/SAGUG/exadata-storage-server- snapshots.htm#SAGUG-GUID-E1D6EF45-36EF-40E3-A57E-F80B749E6122
http://www.oracle.com/technetwork/database/exadata/learnmore/exadata-database-copy-twp-2543083.pdf

NEW QUESTION 58
An Exadata storage server physical disk on an X5 high-capacity full rack entered the predictive failure state.
Identify the two steps that you must perform to replace this failed physical disk.

A. Add the griddisks back into the ASM diskground they used to be a member of.
B. Create a new celldisk and new griddisks on the replaced physical disk.

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

C. Verify that the griddisks located on the physical disk have been successfully dropped from the associated ASM diskgroups.
D. Identify the griddisks located on the failed physical disk and drop them from the associated ASM diskgroups.
E. Replace the failed physical disk.

Answer: CE

Explanation: You may need to replace a physical disk because the disk is in warning - predictive failure status. The predictive failure status indicates that the
physical disk will soon fail, and should be replaced at the earliest opportunity. The Oracle ASM disks associated with the grid disks on the physical drive are
automatically dropped, and an Oracle ASM rebalance relocates the data from the predictively failed disk to other disks.
Note: After the physical disk is replaced, the grid disks and cell disks that existed on the previous disk in that slot are re-created on the new physical disk. If those
grid disks were part of an Oracle ASM group, then they are added back to the disk group, and the data is rebalanced on them, based on the disk group
redundancy and ASM_POWER_LIMIT parameter.
References:http://docs.oracle.com/cd/E80920_01/DBMMN/maintaining-exadata-storage-servers.htm#DBMMN21047

NEW QUESTION 60
Which three factors should you consider when choosing a method for migrating a database to the X5 Database Machine?

A. The down time allowed for the migration


B. Endian format of the source database
C. Number of tablespaces in the source database
D. The type of database workloads
E. Size of the source database

Answer: BDE

Explanation: B: Endian format: Non-Exadata format


D: Use Real Production Workload
– Real Application Testing (RAT) References:

NEW QUESTION 61
You are planning the monitoring configuration for your X5 Database Machine.
Which two components are monitored directly through the use of Exadata –specific Enterprise Manager Plug-Ins?

A. the database server Clusterware


B. the storage server ILOM
C. ASM instances
D. the database server O/S
E. the Infiniband switches

Answer: BE

Explanation: The Oracle Enterprise Manager Grid Control Exadata Monitoring plug-in bundle allows you to monitor the following key components of Exadata
machine:
References:http://www.oracle.com/technetwork/oem/grid-control/exadata-plug-in-bundle- 188771.html

NEW QUESTION 66
Which two statements are true about the Enterprise Manager plug-in configuration for the X5 Database Machine?

A. There is one plug-in for Cloud Control.


B. There are several separate plug-ins for Cloud Control.
C. Some components of the Database Machine require SNMP trap forwarders.
D. All components of the Database Machine require SNMP trap forwarders.

Answer: AC

NEW QUESTION 67
Which three are true concerning Hybrid Columnar Compression (HCC) deployed on Exadata storage?

A. HCC can be used only when the Exadata Smart Flash Cache is configured in Write- Through mode.
B. HCC data is never cached in the Exadata Smart Flash Cache.
C. By default, decompression is performed by Exadata Storage Servers.
D. Rows residing in HCC compressed segments, are always self- contained in a single database block.
E. Rows residing in HCC compressed segments, are always self- contained in a single compression unit.
F. Row-level locks are supported on HCC compressed data.

Answer: CEF

Explanation: C: The decompression process typically takes place on the Oracle Exadata Storage Server in order to maximize performance and offload processing
from the database server.
E: A logical construct called the compression unit is used to store a set of hybrid columnar compressed rows. When data is loaded, column values for a set of rows
are grouped together and compressed. After the column data for a set of rows has been compressed, it is stored in a compression unit.
F: What happens when I update a row on compressed tables? What about locks?
Note: Oracle’s Hybrid Columnar Compression technology is a new method for organizing data within a database block. As the name implies, this technology
utilizes a combination of both row and columnar methods for storing data. This hybrid approach achieves the compression benefits of columnar storage, while
avoiding the performance shortfalls of a pure columnar format.

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

NEW QUESTION 70
You are evaluating the performance of a SQL statement that accesses a very large table. You run this query:

Identify two reasons why the “cell physical IO interconnect bytes” statistic is greater than the “cell physical IO interconnect bytes returned by smart scan” statistic.

A. There is a transaction, which committed after the query began, that has modified some of the table blocks, causing some “cell single block physical reads” to be
requested by the database instance, resulting in additional I/O.
B. There are chained rows in the table, causing some “single block physical reads” to be requested by the database instance, resulting in additional I/O.
C. The table is a hash clustered table, causing “cell multiblock physical reads” to be requested by the database instance, resulting in additional I/O.
D. The table is list partitioned, causing “cell list of blocks physical reads” to be requested by the database instance, resulting in additional I/O.
E. There is a local index on a list partitioned table on the column used in the WHERE clause, causing “cell list of blocks physical reads” to be requested by the
database instance, resulting in additional I/O.

Answer: CD

Explanation: C: Scan on a clustered table can prevent a Smart Scan from occur.
D: Scan on an index-organized table can prevent a Smart Scan from occur.
Note: The Cell physical IO interconnect bytes returned by smart scan metric shows how many bytes of I/O were returned by a smart scan to the database server.
References:https://uhesse.com/2011/01/19/exadata-part-i-smart-scan/

NEW QUESTION 72
Which three statements are true about bulk data loading capabilities in an X5 Database Machine environment?

A. DBFS must use the DBFS_DG diskgroup for any DBFS store.
B. DBFS may be used if Exadata-based shared storage is required to stage data before bulk loading into a database.
C. DBFS must be used to have a POSIX-compliant shared storage solution that is accessible from the database servers on a Database Machine.
D. DBFS must be used to bulk load data into a production database on the Database Machine.
E. ACFS may be used if Exadata-based shared storage is required to stage data before bulk loading into a database.
F. ACFS must be used to have a POSIX –compliant shared storage solution that is accessible from the database servers on a Database Machine.
G. ACFS may use the DBFS_DG diskgroup to contain the ADVM volume file.

Answer: BCD

Explanation: External tables on DBFS file-systems provide the probably the most high-performance way to bulk load data into your database.
Bulk Data Loading
Describe the various options for staging data to be bulk loading into Database Machine Configure the Database File System (DBFS) feature for staging input data
files
Use external tables based on input data files stored in DBFS to perform high-performance data loads

NEW QUESTION 75
Which three are sources for alerts from storage servers in an X5 Database Machine?

A. Software errors reported by the MS process on the storage servers


B. Hardware sensor alerts reported by the CELLSRV process on the storage servers
C. Software errors reported by the RS process on the storage servers
D. Hardware sensor alerts detected by the ILOM on the storage servers
E. Metrics that have administrator-defined thresholds on the storage servers

Answer: ABE

Explanation: AB: The Management Server (MS) process receives the metrics data from CELLSRV, keeps a subset of metrics in memory, and writes to an internal
disk-based repository hourly. In addition, the MS process can generate alerts for important storage cell hardware or software events.

NEW QUESTION 80
Which three are true about Exadata Smart Flash Log?

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

A. Databases on the Database Machine use Exadata Smart Flash Log by default.
B. I/O Resource Manager database plans can be used to enable or disable Exadata Smart Flash Log for individual databases.
C. LGWR will not wait for writes to Exadata Smart Flash Log if the write to a disk-based logfile completes first.
D. I/O Resource Manager category plans can be used to enable or disable Exadata Smart Flash Log for different I/O categories.
E. The use of Exadata Smart Flash Logs is mandatory for support of production databases.

Answer: ABC

Explanation: A: Exadata I/O Resource Manager (IORM) has been enhanced to enable or disable Smart Flash Logging for the different databases running on the
Database Machine, reserving flash for the most performance critical databases.
B: The Exadata I/O Resource Manager (IORM) has been enhanced to enable or disable Smart Flash Logging for the different databases running on the Database
Machine.
C: Smart Flash Logging works as follows. When receiving a redo log write request, Exadata will do parallel writes to the on-disk redo logs as well as a small
amount of space reserved in the flash hardware. When either of these writes has successfully completed the database will be immediately notified of completion. If
the disk drives hosting the logs experience slow response times, then the Exadata Smart Flash Cache will provide a faster log write response time.
Conversely, if the Exadata Smart Flash Cache is temporarily experiencing slow response times (e.g., due to wear leveling algorithms), then the disk drive will
provide a faster response time.
This algorithm will significantly smooth out redo write response times and provide overall better database performance.

NEW QUESTION 83
You plan to migrate an Oracle database supporting an online transaction processing (OLTP) workload to an X5 Exadata Database Machine.
The database machine is running database version 12.1.0.2. The source database has these attributes:
Database version: 12.1.0 Byte order: Big Endian Database size: 24 TB
You have decided to perform physical migration using the Transportable Tablespace method.
Examine this list of possible steps to accomplish this task.
1. Create a new 12.1.0.2 Exadata –based database.
2. Export the source system metadata using transportable Tablespace (TTS).
3. Transfer the files to the Database Machine and use the RMAN CONVERT command to change them to the little endian format.
4. Import the metadata into the target database.
5. Use the RMAN CONVERT to change the database files to the little endian format on the source system.
Identify the required steps in the correct order.

A. 1, 2, 4, 5
B. 1, 2, 5, 3, 4
C. 1, 2, 3, 4, 5
D. 1, 2, 3, 4
E. 1, 2, 5, 4, 3
F. 1, 2, 5, 4

Answer: D

Explanation: Step 1: 1. Create a new 12.1.0.2 Exadata –based database.


Step 2: 2. Export the source system metadata using transportable Tablespace (TTS). Step 3: 3. Transfer the files to the Database Machine and use the RMAN
CONVERT command to change them to the little endian format.
Step 4: 4. Import the metadata into the target database.
This method is often chosen when migrating between platforms with different endian formats, or in cases where physical re-organization is not necessary.
The transportable tablespace method is generally mu References:https://docs.oracle.com/en/cloud/paas/exadata-cloud/csexa/mig-transportable-tablespace.html

NEW QUESTION 87
Examine this list of software components:
1. Oracle Virtual Machine (OVM)
2. Oracle Enterprise Manager Agent (OMA)
3. ASM instance
4. RDBMS instance
5. Automatic Diagnostic Repository Command Interpreter (ADRCI)
6. CELLCLI
7. Cell Server (CELLSRV)
8. diskmon
Identify the location where these software components can run in the standard Exadata Database Machine deployment.

A. 1, 2, 3 and 4 run on the database servers; 5, 6, 7, and 8 run on the Exadata storage servers.
B. 1, 2, 3, 4, 5, and 8 run on the database servers; 5, 6, and 7 run on the Exadata storage servers.
C. 1, 2, 3, 4 and 8 run on the database servers; 5, 6, and 7 run on the Exadata storage servers.
D. 3, 4 and 8 run on the database servers; 1, 2, 5, 6 and 7 run on the Exadata storage servers.
E. 2, 3, 4 and 8 run on the database servers; 1, 5, 6 and 7 run on the Exadata storage servers.

Answer: B

Explanation: Automatic Diagnostic Repository Command Interpreter (ADRCI) can be used on an Exadata storage server.

NEW QUESTION 89
Which three are recommended options on an X5 Exadata Database machine, for staging files that will be loaded as external tables?

A. on an ACFS file system stored in a staging database on the Database Machine


B. a ZFS over NFS file system mounted on a database server where the external table will be accessed
C. an Exadata-based ACFS file system on the Database Machine
D. a DBFS file system stored in a staging database on the Database Machine

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

E. on local storage on one or more storage servers that are accessible to the database server where the load will be performed

Answer: ABE

NEW QUESTION 94
Which two statements are true about backup performance when using Recovery Manager (RMAN) on an X5 Database Machine?

A. Backups are fast because the Infiniband network is faster than fiber channel storage, so RMAN read I/O operations are faster than in traditional storage
networks.
B. Backups are fast, because physical I/Os operations are reduced by the use of the Storage Index by cellsrv.
C. Backups are fast, because data blocks are read from the Database Flash Cache.
D. Backups are fast, because all data blocks are read from the Exadata Smart Flash Cache.
E. For incremental backups using Block Change Tracking, cellsrv filters blocks and returns only those that have changed since the last backup.

Answer: DE

Explanation: D: The storage server software manages the flash cache and can recognize different types of I/O requests so that non-repeatable data access like
RMAN backup I/O does not flush database blocks from the cache. It also prioritizes frequently accessed block types such as redo logs, control files, and index root
blocks.
E: RMAN block change tracking allows incremental backups to run very quickly and efficiently. With block change tracking, only the areas of the database that
have been modified since the last incremental backup or full backup are read from disk.

NEW QUESTION 96
Which three are true concerning Smart Scans?

A. The decision to perform a Smart Scan is made by the Optimizer.


B. Smart Scans are only possible during full table scans or fast full index scans.
C. Smart Scans are possible on Index Organized Tables (IOTs).
D. Smart Scans always outperform scans that are not offloaded.
E. Smart Scans are possible on heap organized tables.
F. Smart Scans are possible on uncompressed B*Tree indexes.

Answer: ABF

Explanation: B: In order for queries to take advantage of Exadata’s Offloading capabilities, the optimizer must decide to execute a statement with a Full Table
Scan or a Fast Full Index Scan.
F: Smart Scans can be used for full scanning through B*Tree index segments. References: Expert Oracle Exadata - K. Osborne, et al., (Apress, 2011) BBS, page
346

NEW QUESTION 98
Which statement is true about operating systems in an X5 Database Machine multirack configuration consisting of two full racks and one Exadata storage
expansion rack?

A. All Exadata storage servers used by the same virtual cluster nodes must run the same O/S but Exadata Storage Servers in different clusters may run different
operating systems.
B. All Exadata storage servers must run the Oracle Solaris O/S and all database servers within the same cluster must run Oracle Linux.
C. All Exadata storage servers may run Oracle Virtual Machine (OVM).
D. All Exadata storage servers must run Oracle Linux.
E. All Exadata storage servers must run the Oracle Linux O/S and all database servers within the same cluster must run the same version of Oracle Virtual
Machine (OVM).

Answer: D

Explanation: On both physical and virtual deployments, Exadata systems use minimal Linux distributions to ensure that just the RPMs needed to run Oracle
database, are installed and enabled.
References:http://www.oracle.com/technetwork/database/exadata/exadata-x5-2-ds- 2406241.pdf

NEW QUESTION 101


You installed ASR Manager on a stand-alone server and configured Auto Service Request (ASR) for your X5 Database Machine and its assets.
Which three statements are true about this configuration?

A. Simple Network Management Protocol (SNMP) traps are used to send notifications fromdatabase servers to the ASR Manager.
B. Simple Network Management Protocol (SNMP) traps are used to send notifications from storage servers to the ASR Manager.
C. When a component fault occurs, fault telemetry is securely transmitted to Oracle via Simple Network Management Protocol (SNMP).
D. When a component fault occurs, fault telemetry is securely transmitted to Oracle via HTTPS.
E. Simple Network Management Protocol (SNMP) traps are used to send notifications from the Enterprise Manager to the ASR Manager.
F. Simple Network Management Protocol (SNMP) traps received by ASR Manager are forwarded to the Enterprise Manager.

Answer: BCF

Explanation: B: Oracle ASR Manager only processes SNMP traps that are sent from IP addresses that Oracle ASR Manager recognizes.
Example of Exadata Storage Server SNMP Trap
This example shows the SNMP trap for an Exadata Storage Server disk failure. The corresponding hardware alert code has been highlighted.
2011-09-07 10:59:54 server1.example.com [UDP: [192.85.884.156]:61945]:
RFC1213-MIB::sysUpTime.0 = Timeticks: (52455631) 6 days, 1:42:36.31 SNMPv2-SMI::snmpModules.1.1.4.1.0 = OID: SUN-HW-TRAP-
MIB::sunHwTrapHardDriveFault

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

SUN-HW-TRAP-MIB::sunHwTrapSystemIdentifier = STRING: Sun Oracle Database Machine


Etc.
C (not D): The ASR Manager uses the SNMP GET protocol to query ASR assets for additional fault information.
To configure fault telemetry, choose one of the following three options:
Add SNMP Trap Destinations Using OneCommand (recommended for new installations) Add SNMP Trap Destinations for Multiple Servers Using the dcli Utility
Add SNMP Trap Destinations for a Single Server
References: http://docs.oracle.com/cd/E80920_01/ASXQI/toc.htm
https://docs.oracle.com/cd/E37710_01/install.41/e18475/ch5_troubleshooting.htm#ASRUD 331

NEW QUESTION 104


You are designing the monitoring architecture and procedures for an X5 Database Machine fabric consisting of two full racks, to provide for the monitoring for all
components on the critical path of the admin network.
Which two components need to be monitored?

A. the Infiniband leaf switches


B. the power distribution units
C. the Cisco 48 port Catalyst Ethernet Switch
D. the InfiniBand spine switches

Answer: CD

Explanation: The Cisco Catalyst 4948 Ethernet switch is supplied with the Oracle Exadata Rack. D: Figure: Running the Subnet Manager in Different Rack
Configurations

References:
https://docs.oracle.com/cd/E18476_01/doc.220/e18478/GUID-9FF8B5B0-3481-4B73-89D3-108CBD7EB989.htm#ELMOG76346
http://docs.oracle.com/cd/E80920_01/DBMIN/configuring-exadata.htm#DBMIN21274

NEW QUESTION 109


You are in the process of upgrading your X5 Database Machine half rack to a full rack. The new storage servers are called DM01CEL08 through DM01CEL14.
After creating 96 new griddisks, you issued this SQL statement:

How many failgroups if any, will be added to the DATA diskgroup by executing this SQL statement?

A. 0, because the new griddisks will be added to the existing failgroups


B. 12, consisting of seven griddisks each
C. 96, consisting of seven griddisk each
D. 7, consisting of 12 griddisks each
E. 1, consisting of all 96 griddisks

Answer: D

Explanation: The number of failure groups equals the number of Exadata Cells. Each failure group is composed of a subset of grid disks in the Oracle ASM disk
group that belong to a single storage cell.
References:http://docs.oracle.com/cd/E80920_01/SAGUG/exadata-administering-asm.htm

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

NEW QUESTION 112


You plan to migrate a database supporting an OLTP workload to your new X5 Database Machine.
The current database instance supports a large number of short duration sessions and a very high volume of short transactions.
Which three X5 Database Machine features can improve performance for this type of workload?

A. An improved highly efficient undo and redo architecture


B. Faster optimization due to an Exadata-specific optimizer
C. Reduced I/O latency for writes due to writeback flashcache on all Exadata X5 and later models
D. Ultra high I/O performance for reads and writes when using Exadata Extreme Flash in X5 and later models
E. Reduced I/O latency for reads due to read flashcache on all Exadata X5 and later models

Answer: ACD

Explanation: A: To further accelerate OLTP workloads, the Exadata Smart Flash Cache also implements a special algorithm to reduce the latency of log write I/Os
called Exadata Smart Flash Logging.
C: Use the Write-Back Flash Cache feature to leverage the Exadata Flash hardware and make Exadata Database Machine a faster system for Oracle Database
Deployments.
D: Exadata X5-2 introduces Extreme Flash Storage Servers. Each Extreme Flash storage server contains eight 1.6 TB state-of-the-art PCI Flash drives. PCI flash
delivers ultra-high performance by placing flash memory directly on the high speed PCI bus rather than behind slow disk controllers and directors.
References:http://www.oracle.com/technetwork/database/exadata/exadata-x5-2-ds- 2406241.pdf
http://www.oracle.com/technetwork/articles/database/exadata-write-back-flash- 2179184.html

NEW QUESTION 115


......

The Leader of IT Certification visit - https://www.certleader.com


100% Valid and Newest Version 1z0-070 Questions & Answers shared by Certleader
https://www.certleader.com/1z0-070-dumps.html (90 Q&As)

Thank You for Trying Our Product

* 100% Pass or Money Back


All our products come with a 90-day Money Back Guarantee.
* One year free update
You can enjoy free update one year. 24x7 online support.
* Trusted by Millions
We currently serve more than 30,000,000 customers.
* Shop Securely
All transactions are protected by VeriSign!

100% Pass Your 1z0-070 Exam with Our Prep Materials Via below:

https://www.certleader.com/1z0-070-dumps.html

The Leader of IT Certification visit - https://www.certleader.com


Powered by TCPDF (www.tcpdf.org)

You might also like