You are on page 1of 1

NOTES:

ARAMCO.
FINISHES
1. ALL DIMENSIONS ARE IN MILLIMETERS (MM) UNLESS
1600 1600
OTHERWISE NOTED. COORDINATES AND ELEVATIONS
CEILING
1500 1500 ARE IN METERS (M).

SAUDI
1100 985 515 1000 1100 1100 1000 CLG-1 600 MM X 600 MM SUSPENDED CEILING
985 515 2. ALL COORDINATES ARE BASED ON THE AIN AL ABD
1000 900 900 SYSTEM MINERAL FIBER INFILL
1000 1000 1970 ON THE INTERNATIONAL HAYFORD 1924
SPHEROID. GRID COORDINATES ARE LISTED ON THE

OF
METAL CLG-2 600 MM X 600 MM SUSPENDED CEILING
BULLET PROOF GLASS
METAL DOOR
HOLLOW METAL
UTM PROJECTION ZONE 39 N AND CENTRAL
METAL DOOR LEAF DOOR LEAF METAL DOOR LEAF METAL SYSTEM FIBER REINFORCED GYPSUM INFILL
LEAF MERIDIAN 51 E.
WITH BALLISTIC DOOR LEAF DOOR LEAF

CONSENT
METAL DOOR JAMB METAL DOOR (WATER AND MOISTURE RESISTANT)
RESISTANCE NIJ LEVEL-III

2550
2500
JAMB

2350
2300
METAL DOOR JAMB LEVER HANDLE 3. ALL LEVELS ARE RELATIVE TO CHART DATUM
2150

2150

2150

2150

2150
LEVER HANDLE LEVER HANDLE LEVER HANDLE LEVER HANDLE
2100

2100

2100

2100

2100
LEVER HANDLE
ES-1 EXPOSED STRUCTURE PAINTED
LEVER HANDLE DETERMINED AT THE TIDAL GAUGE RAK-1 IN THE
1050 EXISTING PORT. ± 0.000 CD(M)=LOWEST

1050

1050

1050

1050

1050

1050
METAL DOOR JAMB METAL DOOR JAMB METAL DOOR JAMB
KICK PLATE WALL
ALUMINUM ALUMINUM ASTRONOMICAL TIDE (LAT).

WRITTEN
METAL DOOR JAMB
KICK PLATE KICK PLATE
PW-1 19MM PLYWOOD FINISHED WITH TWO COATS
4. ALL DIMENSIONS SHALL BE CHECKED AND VERIFIED
D86 D89 D90 D91 D92 D47 OF FIRE RETARDANT PAINT
D42 ON SITE BY THE SUB-CONTRACTOR/CONSTRUCTION
(20MM THICK CEMENT SAND RENDER ON
CONTRACTOR AND ANY DISCREPANCIES SHALL BE
BLOCKWORK WITH TWO COATS OF FIRE
REPORTED TO SITE-IN-CHARGE.

THE
RETARDANT PAINT ABOVE FALSE CEILING)

5. DRAWING SHALL NOT BE SCALED.


PT-1 EMULSION PAINT TO GYPSUM PLASTER

WITHOUT
6. THESE DRAWINGS SHALL BE READ IN CONJUNCTION
PT-2 WATERBORNE PAINT TO GYPSUM PLASTER
WITH ALL OTHER PROJECT ARCHITECTURAL AND
ENGINEERING DOCUMENTS.
CL-1 CERAMIC TILE 200X200 MM

DRAWING
1500 7. FOR EXTERNAL FINISHES GRADIENTS REFER TO
FLOOR
INFRASTRUCTURE GRADING PLAN AND MASTER PLAN.

DOUBLE GLAZED BULLET TL-1 CERAMIC TILE 200X200 MM (ANTI-SKID)


8. FOR STRUCTURAL SLAB PENETRATIONS, SITE
PROOF GLASS WITH BALISTIC
SERVICES AND SUBSTRUCTURE INTERFACES. REFER
PROTECTION NIJ LEVEL III TL-2 TERRAZZO TILE 300X300 MM

THIS
TO RELEVANT STRUCTURAL DRAWINGS.
1500

TL-3 RAISED ACCESWS FLOOR 600X600MM,


METAL LEAF FRAME 9. FOR INFORMATION ON MEP EQUIPMENT AND
2550

FROM
ANI-STATIC FINISH
METAL FRAME FIXTURES. REFER TO RELEVANT MEP DRAWINGS.

CP-2 CARPET TILE 500X500MM, PILE


10. SITE WIND DIRECTIONS ARE PREDOMINANTLY FROM
1050

OBTAINED
NORTH WEST AND ALSO OCCASIONALLY FROM
SOUTH-EAST.
SKIRTING

11. THIS DRAWING IS EXTRACTED FROM MODEL


W5 SK-1 CERAMIC SKIRTING
MYDP-6OB-C303-M3-A-000021.RVT

BE
SK-2 TERRAZZO SKIRTING
DOOR SCHEDULE3 12. DOOR / WINDOW SHOP DRAWINGS /SAMPLE
FINISHING/ CATALOGUE FOR HARDWARE DETAILS /

SHALL
WALL OPENING DOOR FRAME DOOR LEAF FRAME FIRE VISION VISION SK-3 MDF MOULDING SKIRTING
LOCATION SHALL BE SUBMITTED TO COMPANY'S
RATING PANEL PANEL
APPROVAL PRIOR TO INSTALLATION.
DOOR TYPE COUNT WIDTH HEIGHT WIDTH HEIGHT WIDTH HEIGHT THICKNESS MATERIAL FINISH DEPTH THICKNESS FRAME FINISH HARDWARE SET (MINS) H W REMARKS
D42 2 1110 2155 1100 2150 1000 2100 12 Glass Glass 150 50 Steel Powder Coated Matt AS/MANUFACTURER NA NA BALLISTIC RESISTANT TO NIJ LEVEL II AS/HCIS SEC-09 (EXTERNAL DOOR)

PART,
D47 2 1010 2155 1000 2150 900 2100 40 Steel Powder Coated Matt 150 50 Steel Powder Coated Matt AS/MANUFACTURER NA NA BALLISTIC RESISTANT TO NIJ LEVEL II AS/HCIS SEC-09 (INTERNAL DOOR)
D86 1 1610 2555 1600 2550 1500 2500 40 Steel Powder Coated Matt 200 50 Steel Powder Coated Matt AS/MANUFACTURER 60 NA NA BALLISTIC RESISTANT TO NIJ LEVEL II AS/HCIS SEC-09 (INTERNAL DOOR)
D89 4 1010 2155 1000 2150 900 2100 40 Steel Powder Coated Matt 150 50 Steel Powder Coated Matt AS/MANUFACTURER 20 NA NA BALLISTIC RESISTANT TO NIJ LEVEL II AS/HCIS SEC-09 (INTERNAL DOOR)

IN
D90 1 1610 2355 1600 2350 1500 2300 40 Steel Powder Coated Matt 200 50 Steel Powder Coated Matt AS/MANUFACTURER 60 NA NA BALLISTIC RESISTANT TO NIJ LEVEL II AS/HCIS SEC-09 (INTERNAL DOOR)

OR
D91 1 1110 2155 1100 2150 1000 2100 40 Steel Powder Coated Matt 150 50 Steel Powder Coated Matt AS/MANUFACTURER 60 NA NA BALLISTIC RESISTANT TO NIJ LEVEL II AS/HCIS SEC-09 (INTERNAL DOOR)
D92 2 1110 2155 1100 2150 1000 2100 40 Steel Powder Coated Matt 150 50 Steel Powder Coated Matt AS/MANUFACTURER 20 NA NA BALLISTIC RESISTANT TO NIJ LEVEL II AS/HCIS SEC-09

FULL,
IN
Window Schedule
REFERENCE DRAWINGS

REPRODUCTION
WALL OPENING WINDOW LIST OF DRAWINGS RA-610971-050
WINODW Sill LIFE SAFETY PLAN RA-610975-001
TYPE Count Width Height Height FINISH MATERIAL GLAZZING THICKNESS HARDWARE SET REMARK BOD ARCHITECTURE RE-609100-001

W5 9 1500 1500 1050 POWDER COATED MATT STEEL BLAST PROOF GLAZZING AS/MANUFACTURER BALLISTIC RESISTANT TO NIJ LEVEL II AS/HCIS SEC-09 MISCELLANEOUS DETAILS RA-610993-001
MISCELLANEOUS DETAILS RA-610993-002

SPECIFICATION - DOORS AND WINDOWS TYPE


B,C & D BUILDINGS RE-609081

NO
SPECIFICATION - ARCHITECTURAL INTERIOR

ARAMCO.
ELEMENTS RE-609085

FINISHING SCHEDULE
KEYPLAN

SAUDI
THIS DRAWING

AREA FLOOR SKIRTING WALL CEILING


ROOM NO.

NORTH EAST SOUTH WEST

OF
CLG-2

CLG-3
CLG-4
CLG-5
CLG-6
EPX-1

CLG-1
TL-2
TL-3
TL-4

CP-2

SK-2
SK-3
SK-4

PT-2

PT-2

PT-2

PT-2

PT-6
AM-1

CM-1

PW-1

CM-1

PW-1

CM-1

PW-1

CM-1

PW-1
TL-1

CP-1

RS-1

SK-1

PT-1

CL-1

PT-1

CL-1

PT-1

CL-1

PT-1

CL-1

ES-1

ROOM NAME REMARK

PROPERTY
101 SECURITY CHECK ● ● ● ● ● ● ●
102 TOILET ● ● ● ● ● ● ●
103 TOILET ● ● ● ● ● ● ●
104 ABLUTION ● ● ● ● ● ● ●
105 SHOE CHANGE FEMALE ● ● ● ● ● ● ●

SOLE
106 PRAYER FEMALE ● ● ● ● ● ● ●
107 OFFICE ● ● ● ● ● ● ●

THE
108 PRIMARY ELV ROOM ● ● ● ● ● ● ●

N
109 PRAYER HALL MALE ● ● ● ● ● ● ●
110 SEARCH ROOM ● ● ● ● ● ● ●

ARE
111 CLEANING ROOM ● ● ● ● ● ● ●
112 ABLUTION ● ● ● ● ● ● ● 0 1.0 2.0 3.0 4.0 5.0

HEREIN
113 SHOE CHANGE MALE ● ● ● ● ● ● ● ● ● ●
METERS
114 ELECTRICAL ROOM ● ● ● ● ● ● ●
115 CORRIDOR ● ● ● ● ● ● ●
SCALE: 1:50

CONTAINED
3MM GAP BETWEEN DOOR LEAF REVISION VALIDATION
AND DOOR FRAME
THIS REVISION NO. 00 IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
5MM CONSTRUCTION TOLERANCE 5MM CONSTRUCTION TOLERANCE
REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:

OUT 25-00053-0007-107

INFORMATION
FRAME DEPTH

DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER


DOOR FRAME WIDTH (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE
NGH/DJR UFA
DOOR LEAF WIDTH 08/26/2020 08/26/2020

REV.NO. DATE REVISION DESCRIPTION


WALL THICKNESS

00 08/26/2020 ISSUED FOR CONSTRUCTION

JOB ORDER/EWO NO.

THE
THIS REVISION IS NOT TO BE USED FOR
SHUTTER 25-00053-0007 CONSTRUCTION UNTIL CERTIFIED AND DATED
NOTE:
IN
SAUDI ARABIAN OIL COMPANY

AND
FRAME
1. ALL GLAZED WINDOW SHALL HAVE 28 MM DOUBLE GLAZED UNITS COMPRISING DRAWING TYPE

ANCHOR 6MM PILKINGTON ACTIVE SUNSHADE NEUTRAL, 16MM ARGON FILLED CAVITY DOOR WINDOW & FINIAHES SCHEDULE SCH
WALL OPENING
AND 6MM OPTITHERM S1 PLUS INNER PANE UNLESS OTHERWISE SPECIFIED

DRAWING
SUPPORT BUILDING (U211-3)
BLOCK WALL
2. GLASS COMPOSITION FOR ALL BALLISTIC GLAZING / SECURITY RATED GLAZING RIGS, PLATFORM AND UTILITIES
SHALL COMPLY WITH HCIS 2017 BALLISTIC REQUIREMENTS. ADDITIONAL
LAMINATED GLAZING LAYERS SHALL BE CONSIDERED TO ABOVE COMPOSITION
RAS AL KHAIR SAUDI ARABIA
UNIT NO. PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.
TO ACHIEVE THE PERFORMANCE REQUIREMENTS.

THIS
TYP ARRANGMENT OF DOOR FRAME AND LEAF
U211 964 R RA-610978 001 00
Saudi Aramco 2615 ENG. (05/05)

CAD CADD-05

You might also like