Professional Documents
Culture Documents
between two fractions with the help of permeable membranes. In general, mechanical
.separation processes for separating gaseous or liquid streams use membrane technology
Contents [hide
Membrane separation processes operate without heating and therefore use less energy
than conventional thermal separation processes such as distillation, sublimation or
crystallization. The separation process is purely physical and both fractions (permeate and
retentate) can be used. Cold separation using membrane technology is widely used in the
food technology, biotechnology and pharmaceutical industries. Furthermore, using
membranes enables separations to take place that would be impossible using thermal
separation methods. For example, it is impossible to separate the constituents of azeotropic
liquids or solutes which form isomorphic crystals by distillation or recrystallization but such
separations can be achieved using membrane technology. Depending on the type of
membrane, the selective separation of certain individual substances or substance mixtures is
possible. Important technical applications include the production of drinking water by
reverse osmosis (worldwide approximately 7 million cubic metres annually), filtrations in the
food industry, the recovery of organic vapours such as petro-chemical vapour recovery and
.the electrolysis for chlorine production
، بشكل عام.وتغطي تقنية الغشاء جميع المقاربات الهندسية لنقل المواد بين جزئين بمساعدة األغشية القابلة لالختراق
.عمليات الفصل الميكانيكية لفصل تيارات الغازية أو السائلة تستخدم تكنولوجيا الغشاء
محتويات [إخفاء
وتعمل عمليات الفصل الغشائي دون تسخين وبالتالي تستخدم طاقة أقل من عمليات الفصل الحراري التقليدية مثل التقطير
يستخدم الفصل.) عملية الفصل هي المادية البحتة ويمكن استخدام كال الكسور (تتخلل و ريتنتات.أو التسامي أو التبلور
. والتكنولوجيا الحيوية والصناعات الدوائية، على نطاق واسع في تكنولوجيا األغذية0البارد باستخدام تكنولوجيا الغشاء
باستخدام األغشية تمكن االنفصال أن يحدث مكان سيكون من المستحيل باستخدام أساليب الفصل،وعالوة على ذلك
فإنه من المستحيل فصل مكونات السوائل أزيوتروبيك أو سولوتيز التي تشكل بلورات، على سبيل المثال.الحراري
اعتمادا على.إيسومورفيك عن طريق التقطير أو إعادة بلورة ولكن يمكن تحقيق هذه الفواصل باستخدام تكنولوجيا الغشاء
وتشمل التطبيقات التقنية الهامة. والفصل االنتقائي من بعض المواد الفردية أو خليط المواد هو ممكن،نوع من الغشاء
وفلترة في صناعة،) ماليين متر مكعب في جميع أنحاء العالم سنويا7 إنتاج مياه الشرب بالتناضح العكسي (حوالي
والتحليل الكهربائي إلنتاج الكلور، واستعادة األبخرة العضوية مثل انتعاش بخار البتروكيماويات،األغذية
About half of the market is in medical applications such as use in artificial kidneys to remove
toxic substances by hemodialysis and as artificial lung for bubble-free supply of oxygen in the
.blood
Mass transfer[edit]
:Two basic models can be distinguished for mass transfer through the membrane
In real membranes, these two transport mechanisms certainly occur side by side, especially
.during ultra-filtration
Solution-diffusion model[edit]
In the solution-diffusion model, transport occurs only by diffusion. The component that
needs to be transported must first be dissolved in the membrane. The general approach of
the solution-diffusion model is to assume that the chemical potential of the feed and
permeate fluids are in equilibrium with the adjacent membrane surfaces such that
appropriate expressions for the chemical potential in the fluid and membrane phases can be
equated at the solution-membrane interface. This principle is more important for dense
membranes without natural pores such as those used for reverse osmosis and in fuel cells.
During the filtration process a boundary layer forms on the membrane. This concentration
gradient is created by molecules which cannot pass through the membrane. The effect is
referred as concentration polarization and, occurring during the filtration, leads to a reduced
trans-membrane flow (flux). Concentration polarization is, in principle, reversible by cleaning
the membrane which results in the initial flux being almost totally restored. Using a
tangential flow to the membrane (cross-flow filtration) can also minimize concentration
.polarization
في معالجة المياه المستعملة 0،تكنولوجيا الغشاء 0أصبحت ذات أهمية متزايدة .مع مساعدة من الترا /ميكروفيلتراشيون فمن
الممكن إلزالة الجسيمات 0،الغرويات والجزيئات الكبيرة ،بحيث يمكن تطهير المياه العادمة بهذه الطريقة .وھذا ضروري
إذا تم تصریف المیاه العادمة 0في میاه حساسة 0وخاصة تلك المخصصة لالتصال بالرياضات المائیة واالستجمام.
حوالي نصف السوق في التطبيقات الطبية مثل استخدام في الكلى االصطناعية إلزالة المواد السامة عن طريق غسيل
الكلى ورئة اصطناعية لتوفير فقاعة خالية من األكسجين في الدم.
أهمية تكنولوجيا األغشية ينمو في مجال حماية البيئة (قاعدة بيانات نانوميمبرو إيب) .حتى في تقنيات استعادة الطاقة
الحديثة يتم استخدام األغشية على نحو متزايد ،على سبيل المثال في خاليا الوقود وفي محطات 0الطاقة التناضحي.
نموذج الهيدروديناميكية.
في األغشية الحقيقية ،هاتين اآلليتين النقل تحدث بالتأكيد جنبا إلى جنب ،وخصوصا خالل الترشيح الفائق.
وفي نموذج نشر الحلول ،ال يحدث النقل إال بالنشر .يجب أن يتم حل المكون الذي يجب نقله أوال في الغشاء .والنهج العام
لنموذج نشر الحل هو افتراض أن اإلمكانات الكيميائية للسوائل العلفية والمخللة تكون في حالة توازن مع األسطح الغشائية
المجاورة بحيث يمكن مساواة التعبيرات المناسبة لإلمكانات الكيميائية في مرحلتي السوائل والغشاء عند الحل واجهة
غشاء .هذا المبدأ هو أكثر أهمية لألغشية كثيفة دون المسام الطبيعية مثل تلك المستخدمة 0اللتناضح العكسي وفي خاليا
الوقود .خالل عملية الترشيح أشكال طبقة الحدود على الغشاء .يتم إنشاء 0هذا التدرج التركيز من قبل الجزيئات التي ال
يمكن أن تمر من خالل الغشاء .ويشار إلى تأثير االستقطاب التركيز ،والتي تحدث أثناء الترشيح ،يؤدي إلى انخفاض
تدفق عبر غشاء (تدفق) .االستقطاب التركيز هو ،من حيث المبدأ ،عكسها 0عن طريق تنظيف الغشاء مما يؤدي إلى تدفق
األولي يجري استعادة تماما تقريبا .باستخدام تدفق عرضي إلى الغشاء( 0عبر تدفق الترشيح) يمكن أيضا تقليل تركيز
االستقطاب
]Hydrodynamic model[edit
Transport through pores – in the simplest case – is done convectively. This requires the size
of the pores to be smaller than the diameter of the two separate components. Membranes
which function according to this principle are used mainly in micro- 1111111e
`111111ules form a pulpy mass (filter cake) on the membrane, and this blockage of the
membrane hampers the filtration. This blockage can be reduced by the use of the cross-flow
method (cross-flow filtration). Here, the liquid to be filtered flows along the front of the
membrane and is separated by the pressure difference between the front and back of the
membrane into retentate (the flowing concentrate) on the front and permeate (filtrate) on
the back. The tangential flow on the front creates a shear stress that cracks the filter cake
\د\ححand reduces the fouling
Membrane operations[edit]
microfiltration
ultrafiltration
nanofiltration
reverse osmosis
pervaporation
forward osmosis
artificial lung
gas separation
electrodialysis
electrodeionization
electrofiltration
fuel cell
Operations in a temperature gradient
membrane distillation
Cross-flow geometry
النقل من خالل المسام -في أبسط حالة -يتم القيام به بحمل .وهذا يتطلب حجم المسام لتكون أصغر من قطر المكونين
منفصلين .األغشية التي تعمل وفقا لهذا المبدأ تستخدم أساسا في الدقيقة والترشيح الفائق .وهي تستخدم لفصل الجزيئات
من الحلول ،الغرويات من تشتت أو إزالة البكتيريا .خالل هذه العملية الجسيمات 0االحتفاظ أو الجزيئات تشكل كتلة اللب
(كعكة مرشح) على الغشاء 0،وهذا انسداد الغشاء يعيق الترشيح .ويمكن تخفيض هذا االنسداد عن طريق استخدام طريقة
عبر تدفق (الترشيح عبر تدفق) .هنا ،السائل لتصفية التدفقات 0على طول الجزء األمامي من الغشاء 0ويتم فصلها عن طريق
فرق الضغط بين األمامي والخلفي من الغشاء 0في ريتنتات (تتدفق التركيز) على الجبهة وتخلل (الترشيح) على ظهره.
التدفق المائل على الجبهة يخلق إجهاد القص الذي يشقق كعكة المرشح ويقلل من قاذورات.
الدقيق
الترشيح الفائق
الترشيح الدقيق
التناضح العكسي
غسيل الكلى
pervaporation
الرئة االصطناعية
فصل الغاز
الكهربي
الكهربائية لل
electrofiltration
خلية الوقود
غشاء التقطير
Dead-end geometry
There are two main flow configurations of membrane processes: cross-flow (or) tangential
flow and dead-end filtrations. In cross-flow filtration the feed flow is tangential to the
surface of membrane, retentate is removed from the same side further downstream,
whereas the permeate flow is tracked on the other side. In dead-end filtration the direction
of the fluid flow is normal to the membrane surface. Both flow geometries offer some
advantages and disadvantages. Generally, dead-end filtration is used for feasibility studies
on a laboratory scale. The dead-end membranes are relatively easy to fabricate which
reduces the cost of the separation process. The dead-end membrane separation process is
easy to implement and the process is usually cheaper than cross-flow membrane filtration.
The dead-end filtration process is usually a batch-type process, where the filtering solution is
loaded (or 34r4zzazzweslowly fed) into the membrane device, which then allows passage of
some particles subject to the driving force. The main disadvantage of a dead end filtration is
the extensive membrane fouling and concentration polarization. The fouling is usually
induced faster at higher driving forces. Membrane fouling and particle retention in a feed
solution also builds up a concentration gradients and particle back flow (concentration
polarization). The tangential flow devices are more cost and labor-intensive, but they are
less susceptible to fouling due to the sweeping effects and high shear rates of the passing
flow. The most commonly used synthetic membrane devices (modules) are flat
.sheets/plates, spiral wounds, and hollow fibers
Flat plates are usually constructed as circular thin flat membrane surfaces to be used in
dead-end geometry modules. Spiral wounds are constructed from similar flat membranes
but in the form of a “pocket” containing two membrane sheets separated by a highly porous
support plate.[1] Several such pockets are then wound around a tube to create a tangential
flow geometry and to reduce membrane fouling. hollow fiber modules consist of an
assembly of self-supporting fibers with dense skin separation layers, and a more open matrix
helping to withstand pressure gradients and maintain structural integrity.[1] The hollow
fiber modules can contain up to 10,000 fibers ranging from 200 to 2500 μm in diameter; The
main advantage of hollow fiber modules is very large surface area within an enclosed
.volume, increasing the efficiency of the separation process
هناك نوعان من التكوينات تدفق الرئيسي من عمليات الغشاء :عبر تدفق (أو) تدفق عرضي والفلترة في نهاية المطاف
فيلتيراتيونس .في الترشيح عبر تدفق تدفق األعالف هو عرضي على سطح الغشاء 0،تتم إزالة ريتنتات من نفس الجانب
مزيد من المصب ،في حين يتم تتبع تدفق متخلل على الجانب اآلخر .في الترشيح نهاية نهاية االتجاه من تدفق السائل أمر
طبيعي إلى سطح الغشاء .كال الهندسة تدفق تقدم بعض المزايا وعيوب .وبصفة عامة ،يستخدم الترشيح الميت في دراسات
الجدوى على نطاق المختبر .واألغشية الميتة سهلة نسبيا لصنعها مما يقلل من تكلفة عملية الفصل .عملية فصل األغشية
الميتة سهلة التنفيذ ،وعادة ما تكون العملية أرخص من الترشيح الغشائي عبر التدفق .عملية الترشيح الميتة عادة ما تكون
عملية من نوع دفعة ،حيث يتم تحميل محلول التصفية (أو تغذى ببطء) في جهاز الغشاء 0،والذي يسمح بعد ذلك بمرور
بعض الجسيمات الخاضعة للقوة الدافعة .العيب الرئيسي لترشيح طريق مسدود هو قاذورات غشاء واسعة واستقطاب
تركيز .وعادة ما يسبب القاذورات أسرع في القوى الدافعة العليا .غشاء قاذورات واحتباس الجسيمات في حل تغذية أيضا
يبني التدرجات تركيز والجسيمات تدفق الظهر (تركيز االستقطاب) .أما أجهزة التدفق العرضية فهي أكثر تكلفة وكثيفة
العمالة ،ولكنها أقل قابلية للتلوث بسبب اآلثار الكاسحة 0ومعدالت القص العالية لتدفق المرور .األكثر شيوعا غشاء
االصطناعية األجهزة (وحدات) هي ورقة مسطحة /لوحات ،والجروح دوامة ،واأللياف جوفاء.
وعادة ما يتم إنشاء لوحات مسطحة كسطح دائري غشاء مسطح رقيقة الستخدامها في وحدات هندسية ميتة .الجروح
الحلزونية شيدت من أغشية مسطحة مماثلة ولكن في شكل "جيب" يحتوي على صفحتين غشائيتين تفصل بينهما لوحة
دعم مسامية 0للغاية ] 1[ .ثم يتم جرح العديد من هذه الجيوب حول أنبوب لخلق هندسة تدفق عرضية والحد من قاذورات
الغشاء .تتكون وحدات األلياف المجوفة من مجموعة من األلياف ذاتية الدعم مع طبقات فصل الجلد الكثيفة ،ومصفوفة
أكثر انفتاحا تساعد على تحمل تدرجات الضغط والحفاظ على سالمة الهيكلية ]1[ .وحدات األلياف المجوفة يمكن أن
تحتوي على ما يصل إلى 10،000األلياف تتراوح بين 200إلى 2500ميكرون في القطر .والميزة الرئيسية للوحدات
األلياف المجوفة هي مساحة 0كبيرة جدا داخل حجم المغلقة ،وزيادة كفاءة عملية االنفصال
Disc tube module is using a cross-flow geometry, and consists of a pressure tube and
hydraulic discs, which are held by a central tension rod, and membrane cushions that lie
]between two discs.[2
The selection of synthetic membranes for a targeted separation process is usually based on
few requirements. Membranes have to provide enough mass transfer area to process large
)amounts of feed stream. The selected membrane has to have high selectivity (rejection
properties for certain particles; it has to resist fouling and to have high mechanical stability.
It also needs to be reproducible and to have low manufacturing costs. The main modeling
equation for the dead-end filtration at constant pressure drop is represented by Darcy’s law:
[1]
where Vp and Q are the volume of the permeate and its volumetric flow rate respectively
(proportional to same characteristics of the feed flow), μ is dynamic viscosity of permeating
fluid, A is membrane area, Rm and R are the respective resistances of membrane and
growing deposit of the foulants. Rm can be interpreted as a membrane resistance to the
solvent (water) permeation. This resistance is a membrane intrinsic property and is expected
to be fairly constant and independent of the driving force, Δp. R is related to the type of
membrane foulant, its concentration in the filtering solution, and the nature of foulant-
membrane interactions. Darcy’s law allows for calculation of the membrane area for a
targeted separation at given conditions. The solute sieving coefficient is defined by the
equation:[1]
التي تعقدها، ويتألف من أنبوب الضغط واألقراص الهيدروليكية،وحدة أنبوب القرص يستخدم هندسة التدفق المتقاطع
]2[ . وسائد الغشاء التي تقع بين قرصين،قضيب التوتر المركزي
األغشية يجب أن.وعادة ما يعتمد اختيار األغشية االصطناعية لعملية الفصل المستهدفة على عدد قليل من المتطلبات
المحدد خصائص0 يجب أن يكون للغشاء.توفر ما يكفي من منطقة نقل الجماعي لمعالجة كميات كبيرة من تيار التغذية
كما. فإنه ال بد من مقاومة قاذورات والحصول على االستقرار الميكانيكية عالية.انتقائية عالية (رفض) لبعض الجسيمات
إن معادلة النمذجة الرئيسية للترشيح الميتة.أنها تحتاج إلى أن تكون قابلة إلعادة اإلنتاج ولها تكاليف التصنيع منخفضة
]1[ :عند انخفاض الضغط المستمر يمثلها قانون دارسي
R_ {m} +{ }1{ \ ليفت ({\ فراكA \ }}} {\ موp = {\ فراك {\ دلتاQ = }}} {دتdV_ {p}{ {\ ديسباليستيل {\ فراك
R_ {m } +{ }1{ \ ليفت ({\ فراكA \ }}} {\ موp = {\ فراك {\ دلتاQ = }}} {دتdV_ {p}{ }} \ \ راك}} {\ فراكR
)}} \ اليمينR
هوμ ،) هي حجم التخلل ومعدل التدفق الحجمي على التوالي (يتناسب مع نفس خصائص تدفق األعالفQ حيث ف و
و وازدياد الودائع من0 هي مقاومة كل من الغشاءR آرإم و0، هو منطقة الغشاءA ،اللزوجة الديناميكية من السائل المتخلل
هذه المقاومة هي غشاء خاصية. آرإم يمكن تفسيرها على أنها مقاومة غشاء إلى المذيبات (المياه) نفاذية.المخالفات
تركيزه، يرتبط بنوع من الغشاء فوالنتΔp. R ،جوهرية ومن المتوقع أن تكون ثابتة إلى حد ما ومستقلة عن القوة الدافعة
في0 منطقة الغشاء لفصل المستهدفة0 قانون دارسي يسمح لحساب. وطبيعة التفاعالت غشاء فوالنت،في حل التصفية
يتم تعريف معامل النخل المذاب من قبل.ظروف معينة
where Cf and Cp are the solute concentrations in feed and permeate respectively. Hydraulic
permeability is defined as the inverse of resistance and is represented by the equation:[1]
where J is the permeate flux which is the volumetric flow rate per unit of membrane area.
The solute sieving coefficient and hydraulic permeability allow the quick assessment of the
.synthetic membrane performance
Membrane separation processes have a very important role in the separation industry.
Nevertheless, they were not considered technically important until the mid-1970s.
Membrane separation processes differ based on separation mechanisms and size of the
separated particles. The widely used membrane processes include microfiltration,
ultrafiltration, nanofiltration, reverse osmosis, electrolysis, dialysis, electrodialysis, gas
separation, vapor permeation, pervaporation, membrane distillation, and membrane
contactors.[3] All processes except for pervaporation involve no phase change. All processes
except (electro)dialysis are pressure driven. Microfltration and ultrafiltration is widely used
in food and beverage processing (beer microfiltration, apple juice ultrafiltration),
biotechnological applications and pharmaceutical industry (antibiotic production, protein
purification), water purification and wastewater treatment, the microelectronics industry,
and others. Nanofiltration and reverse osmosis membranes are mainly used for water
purification purposes. Dense membranes are utilized for gas separations (removal of CO2
from natural gas, separating N2 from air, organic vapor removal from air or a nitrogen
stream) and sometimes in membrane distillation. The later process helps in the separation
.of azeotropic compositions reducing the costs of distillation processes
The pore distribution of a fictitious ultrafiltration membrane with the nominal pore size and
the D90
The pore sizes of technical membranes are specified differently depending on the
manufacturer. One common distinction is by nominal pore size. It describes the maximum
pore size distribution[4] and gives only vague information about the retention capacity of a
membrane. The exclusion limit or "cut-off" of the membrane is usually specified in the form
of NMWC (nominal molecular weight cut-off, or MWCO, molecular weight cut off, with units
in Dalton). It is defined as the minimum molecular weight of a globular molecule that is
retained to 90% by the membrane. The cut-off, depending on the method, can by converted
to so-called D90, which is then expressed in a metric unit. In practice the MWCO of the
membrane should be at least 20% lower than the molecular weight of the molecule that is
.to be separated
حيث سف و كب هي تركيزات المذاب في األعالف و تتخلل على التوالي .وتعرف النفاذية الهيدروليكية بأنها عكس
المقاومة وتمثلها المعادلة]1[ :
حيث Jهو تدفق المتخلل الذي هو معدل التدفق الحجمي لكل وحدة من منطقة الغشاء .معامل النخل المذاب والنفاذية
الهيدروليكية تسمح بتقييم سريع لألداء غشاء االصطناعية.
عمليات الفصل الغشائي لها دور مهم جدا في صناعة الفصل .ومع ذلك ،فإنها لم تعتبر مهمة من الناحية الفنية حتى
منتصف . 1970sتختلف عمليات فصل الغشاء على أساس آليات الفصل وحجم الجسيمات المنفصلة .وتشمل عمليات
الغشاء 0المستخدمة على نطاق واسع الترشيح الدقيق ،والترشيح الفائق ،والترشيح النانوي ،والتناضح العكسي ،والتحليل
الكهربائي ،وغسيل الكلى ،والكهربائية ،وفصل الغاز ،وتخلل البخار ،والتخثر ،وتقطير الغشاء ،ومقاومات الغشاء]3[ .
جميع العمليات باستثناء بيرفابوراتيون ال تنطوي على أي تغيير المرحلة .جميع العمليات باستثناء (الكهربائية) غسيل
الكلى هي الضغط مدفوعة .ويستخدم على نطاق واسع الترشيح الدقيق والترشيح الفائق في معالجة األغذية والمشروبات
(الترشيح الدقيق للبيرة ،الترشيح الفائق عصير التفاح) ،تطبيقات التكنولوجيا الحيوية وصناعة األدوية (إنتاج المضادات
الحيوية ،وتنقية البروتين) ،وتنقية المياه ومعالجة مياه الصرف الصحي ،وصناعة اإللكترونيات الدقيقة ،وغيرها .يتم
استخدام الترشيح النانوي وأغشية التناضح العكسي أساسا ألغراض تنقية المياه .وتستخدم األغشية الكثيفة لفصل الغاز
(إزالة ثاني أآسيد الكربون من الغاز الطبيعي ،وفصل N2عن الهواء ،وإزالة البخار العضوي من الهواء أو تيار
النيتروجين) وأحيانا في التقطير الغشائي .تساعد العملية الالحقة في فصل التركيبات األيزوتروبية التي تقلل من تكاليف
عمليات التقطير.
توزيع المسام من غشاء الترشيح الفائق وهمية مع حجم المسام االسمي و D90
يتم تحديد أحجام المسام من األغشية التقنية بشكل مختلف اعتمادا على الشركة المصنعة .ويتمثل أحد التفرقة الشائعة في
حجم المسام االسمي .وهو يصف التوزيع األقصى لحجم المسام [ ]4ويعطي معلومات غامضة فقط عن القدرة على
االحتفاظ بغشاء .وعادة ما يتم تحديد حد االستبعاد أو "قطع" الغشاء في شكل نموك (قطع الوزن الجزيئي االسمي ،أو
موكو ،قطع الوزن الجزيئي ،مع وحدات في دالتون) .وهو يعرف بأنه الحد األدنى من الوزن الجزيئي للجزيء الكروي
الذي يتم االحتفاظ به إلى ٪ 90بواسطة الغشاء .ويمكن للقطع ،حسب الطريقة ،أن يحول إلى ما يسمى ،D90الذي يعبر
عنه بعد ذلك بوحدة متري .في الممارسة 0العملية يجب أن تكون موكو الغشاء 0أقل بنسبة ٪20على األقل من الوزن
الجزيئي للجزيء الذي يجب فصله
:Filter membranes are divided into four classes according to pore size
larger bacteria, yeast, particles < 2 bar microfiltration > 5000 kDa > µm 0.1
salts, small organic molecules 10-80 bar reverse osmosis < < 100 Da nm 1
The form and shape of the membrane pores are highly dependent on the manufacturing
process and are often difficult to specify. Therefore, for characterization, test filtrations are
carried out and the pore diameter refers to the diameter of the smallest particles which
.could not pass through the membrane
The rejection can be determined in various ways and provides an indirect measurement of
the pore size. One possibility is the filtration of macromolecules (often dextran, polyethylene
glycol or albumin), another is measurement of the cut-off by gel permeation
chromatography. These methods are used mainly to measure membranes for ultrafiltration
applications. Another testing method is the filtration of particles with defined size and their
measurement with a particle sizer or by laser induced breakdown spectroscopy (LIBS). A
vivid characterization is to measure the rejection of dextran blue or other colored molecules.
The retention of bacteriophage and bacteria, the so-called "bacteriachallenge test", can also
.provide information about the pore size
> 0.1ميكرون> 5000كيلو دالتون ميكروفيلتراشيون < 2بار أكبر البكتيريا والخميرة والجسيمات
100-2نانومتر 5000-5كيلو دالتون الترشيح الفائق 10-1بار البكتيريا والجزيئات الصغيرة والبروتينات
والفيروسات الكبيرة
2-1نانومتر 5-0.1كيلو دالتون الترشيح النانوي 20-3بار الفيروسات -2 ،أيونات فالنت []5
< 1نانومتر < 100دا التناضح العكسي 80-10بار األمالح والجزيئات العضوية الصغيرة
شكل وشكل المسام الغشاء تعتمد اعتمادا كبيرا على عملية التصنيع وغالبا ما يصعب تحديدها .لذلك ،لتوصيف ،يتم إجراء
فيلتيراتيونس اختبار والقطر المسام يشير إلى قطر أصغر الجسيمات التي ال يمكن أن تمر عبر الغشاء.
ويمكن تحديد الرفض بطرق مختلفة ويوفر قياس غير مباشر لحجم المسام .أحد االحتماالت هو ترشيح الجزيئات (في
كثير من األحيان ديكستران ،البولي ايثيلين جاليكول أو ألبومين) ،وآخر هو قياس قطع بواسطة هالم نفاذية اللوني.
وتستخدم هذه األساليب أساسا لقياس األغشية لتطبيقات الترشيح الفائق .طريقة االختبار األخرى هي ترشيح الجسيمات مع
حجم محدد وقياسها مع حجم الجسيمات 0أو عن طريق الليزر الطيفي تحريض الطيف (ليبس) .وهناك توصيف حيوي
لقياس رفض ديكستران األزرق أو غيرها من الجزيئات الملونة .اإلبقاء على البكتيريا والبكتيريا ،ما يسمى ب "البكتيريا
اختبار" ،ويمكن أيضا توفير معلومات حول حجم المسام.
لتحديد قطر المسام 0،تستخدم أيضا األساليب الفيزيائية مثل قياس المسامية (الزئبق ،المسامية السائلة والسائلة واختبار نقطة
الفقاعة) ،ولكن يفترض وجود شكل معين من المسام (مثل الثقوب الكروية األسطوانية أو المتسلسلة) .وتستخدم هذه
األساليب لألغشية التي ال تتطابق هندستها المسامية 0مع المثالية ،ونحن نحصل على "االسمية" قطر المسام ،الذي يميز
الغشاء 0،ولكن ال يعكس بالضرورة سلوك الترشيح الفعلي واالنتقائية.
االنتقائية تعتمد اعتمادا كبيرا على عملية الفصل ،وتكوين الغشاء 0وخصائصه الكهروكيميائية باإلضافة إلى حجم المسام.
مع االنتقائية العالية ،يمكن إثراء النظائر (تخصيب اليورانيوم) في الهندسة النووية أو الغازات الصناعية مثل النيتروجين
يمكن استردادها (فصل الغاز) .من الناحية المثالية ،حتى يمكن أن تكون إثراء الجرعات مع غشاء مناسب.
عند اختيار األغشية االنتقائية لها األولوية على نفاذية عالية ،والتدفقات المنخفضة يمكن بسهولة أن يعوض عن طريق
زيادة سطح التصفية مع هيكل وحدات .في طور الترشيح الغاز آليات مختلفة ترسب هي منطوق ،بحيث الجسيمات وجود
أحجام تحت حجم المسام من الغشاء يمكن االحتفاظ بها كذلك.
غشاء اصطناعي
ترسب الجسيمات0
To determine the pore diameter, physical methods such as porosimetry (mercury, liquid-
liquid porosimetry and Bubble Point Test) are also used, but a certain form of the pores
(such as cylindrical or concatenated spherical holes) is assumed. Such methods are used for
membranes whose pore geometry does not match the ideal, and we get "nominal" pore
diameter, which characterizes the membrane, but does not necessarily reflect its actual
.filtration behavior and selectivity
The selectivity is highly dependent on the separation process, the composition of the
membrane and its electrochemical properties in addition to the pore size. With high
selectivity, isotopes can be enriched (uranium enrichment) in nuclear engineering or
industrial gases like nitrogen can be recovered (gas separation). Ideally, even racemics can
.be enriched with a suitable membrane
When choosing membranes selectivity has priority over a high permeability, as low flows can
easily be offset by increasing the filter surface with a modular structure. In gas phase
filtration different deposition mechanisms are operative, so that particles having sizes below
.the pore size of the membrane can be retained as well
See also[edit]
Artificial membrane
Particle deposition