Flexible Sprinkler

Hose with Fittings


■ Easy and fast installation
■ Flexible & durable
■ Corrosion resistant
■ Cost - effective
■ cULus listed
MASTECO Flexible Sprinkler Hose with Fittings EASY AND FAST INSTALL. COST-EFFECTIVE.
Equivalent
Length of
Rated Max Nom Inlet Assembly Max Min Bend 1 in.
MASTECO Flexible Sprinkler Hose with Fittings are essential components Model Pressure, Ambient by Outlet Length, No. of Radius, mm Schedule Flexibility
Type
kPa Temp, °C Size, in. mm 90° Bends 40
for water-based fire sprinkler system. It is available in set consisting of stainless steel flexible hose, nipple, Steel Pipe
reducer, center and side brackets, and square bar. The flexible hose, hand-operated (C = 120), m
locking screw and easy-to-slide brackets enable the unit to be installed and position the MFJ-S700 1206 65 1 by 1/2 700 1 125 7 Limited
sprinkler at the suitable location quickly and with great ease. MFJ-S1000 1206 65 1 by 1/2 1000 2 125 14.9 Limited
MFJ-S1200 1206 65 1 by 1/2 1200 3 125 19.2 Limited
The Flexible Sprinkler Hose with Fittings set eliminates the need MFJ-S1500 1206 65 1 by 1/2 1500 3 125 21.9 Limited
for pipe recutting and/or threading as in the conventional MFJ-S1800 1206 65 1 by 1/2 1800 3 125 27.7 Limited
method; reducing installation time and promoting labor Reprinted from the Online Certifications Directory with permission from UL. © 2014 UL
force productivity. As such, the product’s
cost‐effectiveness extends to maintenance and
retrofitting.

Suitable for residential, commercial


and industrial fire sprinkler systems
with hard or suspended ceiling.

■FLEXIBLE HOSE
▶Factory-fitted with slip nuts for easy installation
▶Equipped with excellent rubber O-rings and insulation
washer to ensure water-tight joints
▶2.3 ft (0.7m) - 5.9 ft (1.8m) assembly lengths
▶Pressure rating of 175 psig (1,206 kPa) MASTECO Flexible Sprinkler Hose with Fittings Set
Available in 2.3 ft (0.7 m), 3.3 ft (1.0 m), 3.9 ft (1.2 m),
4.9ft(1.5 m), and 5.9ft(1.8 m) length.
▶ MASTECO flexible sprinkler with fittings are
intended to be installed with the accompanying
■REDUCER center and side brackets in accordance with the
▶Provides for quick system installation installation instructions.
▶Designed for easy vertical adjustment and
to enable tight bracket grip for convenient ▶ Use of set components is recommended to ensure
positioning of sprinkler product operational performance.
▶Size: 1/2 x 4.5 in
▶ Visit www.masteco.co.kr for more details.

■CENTER BRACKET ■SIDE BRACKETS ■SQUARE BAR ■NIPPLE


▶The octagonal-shaped holes enable the ▶Provide firm hold of the square bar to ▶Designed for strength that is suitable for ▶Connects the flexible hose to the water
reducer to easily slip through up and the ceiling rails supporting the flexible hose fitting assembly pipe line
down for precise sprinkler height ▶Can be easily slide sideways in place ▶The shoulder fits well into the sprinkler hose
adjustment (horizontally) at right angles with square ▶Enables the center bracket to slide sideways slip nut and presses the rubber O-ring when
▶Can be easily slide sideways(horizontally) bar; altogether the reducer, center and along its length for easy and accurate 􀆟 tightened creating a water-tight joint.
along the square bar for easy sprinkler side brackets and the flexible hose placement of sprinkler
placement provide the sprinkler 3D positioning
▶ T h e l o c k i n g s c rew c a n b e q u i c k l y flexibility
operated by hand with minimal effort ▶Designed to fit with various standard
cross tees often used in suspended
ceiling framework

PROTECTION OF LIVES AND VALUABLE ASSETS MATTERS. Reliable partner in fire protection.
www.masteco.co.kr

Global Leader
Towards
in Fire Fighting Equipment
Masteco Industry Co., Ltd. formerly known as Korea Halon was founded in 1984. Since then, the company has been
providing fire protection solutions to a wide array of customers through its innovative and state-of-the-art water and
gaseous-based fire extinguishing product lines. With extensive experience in the development and manufacturing
of such products, Masteco Industry Co., Ltd. has established itself in the Korean market as the leading and trusted
partner in fire protection. As the company extends its market globally, Masteco Industry Co., Ltd. continues to
endeavor for high-quality products that comply with if not exceed the applicable strictest international standards.

■Head Office ■USA Office ■Main Factory


Room 1009, Byeoksan Valley 5 60-73 4310 Regency Dr. 715-12 Gojan-dong, Namdong_gu
Kasan-dong, Guemcheon-gu Seoul, 153-801, Korea Gleenview, IL 60025 Incheon, 405-821, Korea
Tel.: 82-2-785-1301, Fax: 82-2-785-1313 Tel.: 847-759-8872, Fax: 877-520-5357 Tel.: 82-32-811-1301, Fax: 82-32-811-1305
CERTIFICATE OF COMPLIANCE
Certificate Number 20140331-EX15483
Report Reference EX15483-20140330
Issue Date 2014-MARCH-31

Issued to: MASTECO INDUSTRY CO LTD


715-12 146 Bl 13Lt Gojan-Dong
Namdong-Gu
Incheon 405-821 KOREA

This is to certify that FLEXIBLE SPRINKLER HOSE WITH FITTINGS


representative samples of SEE ADDENDUM PAGE

Have been investigated by UL in accordance with the


Standard(s) indicated on this Certificate.

Standard(s) for Safety: UL 2443 STANDARD FOR FLEXIBLE SPRINKLER HOSE


WITH FITTINGS FOR FIRE PROTECTION SERVICE
ULC ULC/ORD-C1474-03 ADJUSTABLE DROP NIPPLES
FOR SPRINKLER SYSTEMS
Additional Information: See the UL Online Certifications Directory at
www.ul.com/database for additional information

Only those products bearing the UL Listing Mark for the US and Canada should be considered as
being covered by UL's Listing and Follow-Up Service meeting the appropriate requirements for US
and Canada.
The UL Listing Mark for the US and Canada generally includes: the UL in a circle symbol with “C” and
“US” identifiers: the word “LISTED”; a control number (may be alphanumeric) assigned by UL;
and the product category name (product identifier) as indicated in the appropriate UL Directory.

Look for the UL Listing Mark on the product.

William R. Carney, Director, North American Certification Programs

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at www.ul.com/contactus

Page 1 of 2
CERTIFICATE OF COMPLIANCE
Certificate Number 20140331-EX15483
Report Reference EX15483-20140330
Issue Date 2014-MARCH-31

This is to certify that representative samples of the product as specified on this certificate were tested
according to the current UL requirements.

USL, CNL-

Models
MFJ-S700, Unbraided
MFJ-S1000, Unbraided
MFJ-S1200, Unbraided
MFJ-S1500, Unbraided
MFJ-S1800, Unbraided

William R. Carney, Director, North American Certification Programs

UL LLC

Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at www.ul.com/contactus

Page 2 of 2