You are on page 1of 7

Test run result D202

Current Part : DZ2606800L


Test run Part : DF2S6.8CT.L3F

Different body printing of the part


Part No DZ2606800L DF2S6.8CT.L3F
Image 2D

Polarity ROI for Part DZ2606800L


Clear not clear
Image 3D

Camera can Camera can not My assume of ROI position for b


part number base on image be
recognize recognize

Different polarity judge by machine


Part No DZ2606800L

the polarity value is much different, so the value gets better

Judgment machine unstable when using part DF2S6.8CT.L3F and fals NG pass rate become low
PROBLEM

ROI for Part DZ2606800L Polarity ROI for Part DF2S6.8CT.L3F

sume of ROI position for both


number base on image below

DF2S6.8CT.L3F

the polarity value has little difference, so the value will be worse and the machine
judgment is unstable
SUGGESTION

Move the polarity ROI (main) to the grey area (make sure
the ROI area in the grey area),
also can try difference type to get big differences value
(Box/bar), also find the clear image plane

From image plane below, i can suggest


to use RGB_Top light

** Big differences value of image plane is depend what type of ROI and whate mode th
rea (make sure

ences value

type of ROI and whate mode that uses