Contents
Page
Committees responsible Inside front cover
Foreword ii
Introduction 1
1 Scope 1
2 Normative references 1
3 Definitions 1
4 Planning 2
5 Components 2
6 Design 2
7 Installation 4
8 Commissioning and documentation 4
9 Servicing and maintenance 4
Annex A (informative) Application factors 5
Annex B (normative) Measurement of the luminous performance of the
photoluminescent system 5
Bibliography 6
Figure 1 Ð Inter-relationships of specific forms of emergency lighting 3
Table 1 Ð Minimum installed luminance characteristics during light decay 4
BSI 10-1999 i
BS 5266-6:1999
Foreword
This part of BS 5266 has been prepared by Technical Committee CPL/34/9, Emergency
Lighting.
This standard is supplementary to, and is intended to be used as an addition to,
BS 5266-1.
The aim of this standard is to promote wider understanding of non-electrical low
mounted way guidance systems, to encourage uniformity of application and to give
advice on their most effective use within buildings.
Owing to the developing nature of the technology, a review of this part of BS 5266 will
commence three years after the date of publication, as opposed to the usual five early
review period.
Annex A is informative. Annex B is normative.
As a code of practice, this British Standard takes the form of guidance and
recommendations. It should not be quoted as if it were a specification and particular
care should be taken to ensure that claims of compliance are not misleading.
A British Standard does not purport to include all the necessary provisions of a
contract. Users of British Standards are responsible for their correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.
Summary of pages
This document comprises a front cover, an inside front cover, pages i and ii, pages 1
to 6, an inside back cover and a back cover.
The BSI copyright notice displayed in this document indicates when the document was
last issued.
ii BSI 10-1999
BS 5266-6:1999
Introduction 3.2
Photoluminescent way guidance systems use lines of photoluminescent system
light emitting visual markers to assist in indicating non-electrical low mounted way guidance system
the location of escape routes and exits. incorporating photoluminescent pigments that, if
Photoluminescent materials and products need excited by UV or visible radiation, store energy
sufficient pre-excitation by normal lighting. On which is emitted as light over a period of time with
failure of the normal lighting supply, the diminishing luminance
photoluminescent system emits the stored energy
over a period of time with diminishing luminance. 3.3
The photoluminescent components remain visible photoluminescent escape route marker
during the period of light decay when the lighting marker forming part of the way guidance system,
fails. readily visible in low ambient light
NOTE Lines of these markers are provided to clearly delineate an
escape route or define an escape path through an open area.
1 Scope
This part of BS 5266 gives recommendations for the 3.4 exit indicator
planning, design, installation and servicing of illuminated indicator forming part of the way
photoluminescent low mounted way guidance guidance system, provided to clearly identify an exit
systems, for use within emergency lighting systems. NOTE It may be used with or without a supplementary sign
mounted adjacent to the exit at low level for use when any
overhead safety sign may be less effective or obscured.
2 Normative references
3.5
The following normative documents contain
provisions which, through reference in this text, exit marking
constitute provisions of this part of this British that part of the way guidance system provided to
Standard. For dated references, subsequent clearly identify an exit by using the luminous
amendments to, or revisions of, any of these marking to outline part or all of the exit surround
publications do not apply. For undated references, 3.6
the latest edition of the publication referred to
applies. intermediate information and exit direction
indicators
BS 5266-1:1988, Emergency lighting Ð Code of
practice for the emergency lighting of premises that part of the way guidance system provided to
other than cinemas and certain other specified identify exit routes and to clearly indicate direction
premises used for entertainment. towards an exit
BS EN 60529:1992, Specification for degrees of 3.7
protection provided by enclosures (IP code). excitation
BS EN 60598-1:1997, Luminaires Ð Part 1: General process by which UV or visible radiation provokes
requirements and tests. the phosphorescent ability of a product
IEC 60598-2-22:1997, Luminaires Ð Particular
3.8
requirements Ð Luminaires for emergency lighting.
excitation lighting
IEC 60092-101, Electrical installations in ships Ð
Part 101: Definitions and general requirements. lighting sufficient to produce the necessary
excitation for a particular application
3 Definitions 3.9
For the purposes of this standard the definitions light decay
given in BS 5266-1 apply, together with the following. time dependent decrease of luminance after the end
of excitation
3.1
non-electrical low mounted way guidance 3.10
system period of light decay
low mounted luminous tracks positioned on escape period after the end of excitation in which the
routes in combination with exit indicators, exit luminance decreases to 0.3 mcd/m2
marking and intermediate direction indicators along
the route, provided for use when the supply to the
normal lighting fails, which do not rely on an
electrical supply for their luminous output
BSI 10-1999 1
BS 5266-6:1999
2 BSI 10-1999
BS 5266-6:1999
BSI 10-1999 3
BS 5266-6:1999
4 BSI 10-1999
BS 5266-6:1999
BSI 10-1999 5
BS 5266-6:1999
Bibliography
[1] GREAT BRITAIN. Health and Safety (Safety Signs and Signals) Regulations 1996, London, The Stationary
Office.
6 BSI 10-1999
blank
BS 5266-6:1999 |
|
|
|
|
|
|
|
|
BSI Ð British Standards Institution
|
|
|
|
|
|
| BSI is the independent national body responsible for preparing British Standards. It
|
| presents the UK view on standards in Europe and at the international level. It is
| incorporated by Royal Charter.
|
|
| Revisions
|
|
| British Standards are updated by amendment or revision. Users of British Standards
|
| should make sure that they possess the latest amendments or editions.
|
|
| It is the constant aim of BSI to improve the quality of our products and services. We
|
| would be grateful if anyone finding an inaccuracy or ambiguity while using this
| British Standard would inform the Secretary of the technical committee responsible,
|
| the identity of which can be found on the inside front cover. Tel: 020 8996 9000.
|
| Fax: 020 8996 7400.
|
|
| BSI offers members an individual updating service called PLUS which ensures that
|
| subscribers automatically receive the latest editions of standards.
|
|
| Buying standards
|
| Orders for all BSI, international and foreign standards publications should be
|
| addressed to Customer Services. Tel: 020 8996 9001. Fax: 020 8996 7001.
|
|
| In response to orders for international standards, it is BSI policy to supply the BSI
|
| implementation of those that have been published as British Standards, unless
|
| otherwise requested.
|
|
| Information on standards
|
| BSI provides a wide range of information on national, European and international
|
| standards through its Library and its Technical Help to Exporters Service. Various
|
| BSI electronic information services are also available which give details on all its
|
| products and services. Contact the Information Centre. Tel: 020 8996 7111.
|
| Fax: 020 8996 7048.
|
|
| Subscribing members of BSI are kept up to date with standards developments and
| receive substantial discounts on the purchase price of standards. For details of
|
| these and other benefits contact Membership Administration. Tel: 020 8996 7002.
|
| Fax: 020 8996 7001.
|
|
| Copyright
|
|
| Copyright subsists in all BSI publications. BSI also holds the copyright, in the UK, of
|
| the publications of the international standardization bodies. Except as permitted
| under the Copyright, Designs and Patents Act 1988 no extract may be reproduced,
|
| stored in a retrieval system or transmitted in any form or by any means ± electronic,
|
| photocopying, recording or otherwise ± without prior written permission from BSI.
|
|
| This does not preclude the free use, in the course of implementing the standard, of
|
| necessary details such as symbols, and size, type or grade designations. If these
|
| details are to be used for any other purpose than implementation then the prior
| written permission of BSI must be obtained.
|
|
| If permission is granted, the terms may include royalty payments or a licensing
|
| agreement. Details and advice can be obtained from the Copyright Manager.
|
| Tel: 020 8996 7070.
|
|
|
|
|
|
|
|
|
BSI |
|
389 Chiswick High Road |
|
London |
|
W4 4AL |
|
|
|
|
|
|