The flue gas condenser supplied by Van Dijk heating:

a success for more than 35 years now!

Flue gas
The Van Dijk heating flue gas condenser was introduced back in 1976,
making it one of our oldest products. A flue gas condenser makes it pos-
sible to cool down flue gases from gas-fired equipment to a temperature
below the dew point and, by doing this, utilise the condensation heat
generated by the flue gases. This results in better efficiency from your
burner and significant savings on your energy bill.
condenser
The strong construction and high quality of the materials used in the Van
More than 35 years proven quality.
Dijk heating flue gas condenser guarantee a long working life and a high
level of efficiency. The energy savings achieved will depend on the business

0.01 EN
situation and may be as much as 15%.
Flue gas condenser
More than 35 years proven quality.

The flue gas condenser at a glance Long working life


>
 Proven quality and a long working life. The heat exchanger in the flue gas
condenser produced by Van Dijk
>

> Sustainable construction.
heating has been made from extruded
>

>
> Modular construction, so a solution is always possible. aluminium ribbed tubes. The inner tube is
made from corten steel and is covered by an aluminium outer tube.
>

>
> Possible to use in all brands of boiler and, of course,
Schoorsteen

Schoorsteen
>

Schoorsteen
Omloopkanaal

in the Van Dijk heating HRWB-2 boiler. Grafiek van het werkingsprincipe van de Rookgascondensor
> An extrusion process is used to press together the tubes and form the
en met 2 schoorstenen

>
>
Zonder omloopkanaal

>
> Good energy savings. aluminium ribbing on the outer tube. The result is a strong construction
Met omloopkanaal
en 1 schoorsteen

Ketel Wisselklep Ketel


>
>
>
15
with optimal heat transfer.
>
>
>  The condenser is easy to integrate into the
Corten steel is a weather-proof
RENDEMENT steel that protects
ALS FUNCTIE itself by forming a
VAN KOELWATERTEMPERATUUR
>
>
> Van Dijk heating CO2 dosing unit.
>
>
> thin oxide layer. As a result, many of the condensers supplied by Van
Kleppen bij groot V.O. condensor
>
> Dijk heating last 25 years and more than 10,000 have been installed
10
>

Capaciteit rookgascondensor
>
>

in % van de ketelcapaciteit
> worldwide so far!
>
>
>
>
>
Modular construction
>
Schornstein

Schornstein

bij klein V.O. condensor


>
Schornstein

5
>
>
>
>
>
Umlauf
Schaltklappe

Sustainable materials
und 2 Schornsteinen

fase 2 fase 1
>
>
The
> Van Dijk heating
> flue gas condenser is available in different t models: with
Ohne Umlaufkanal
und 1 Schornstein

>
Mit Umlaufkanal

or>without a flue-gas side bypass channel and with a single or double


Kessel Kessel

ouble (combi)
>
>
>
0
>
water circuit. Because of the modular construction, Van Dijk heating is able
by a condenser will
20 40 60 100
80 120 140 160 180
>
>
workvaningCV-retourwater ved
life achie(°C)
to> produce a condenser for any type of heating system. When ducing
producing a new The
Temperatuur
fro m
>
> ials used. Right
>
largely on the mater
Klappen
>
> the boiler producer welds the counterflange for the fuel-gas
boiler, -gas side connec- pendRauchgaskondensator
de
Prinzip cided to use
>
>
tion of the condenser to the boiler. This simplifies assembly in the boiler house. e ve ry be gin nin g, Van Dijk heating de
> th in
steel and aluminium
>
>
>
> 15 only
high-quality corten an 35 ye ar s,
>
> ser. After more th
>
>
> its flue gas conden ed th eir
ovKÜHLWASSERTEMPERATUR
IN or e than prDER
Chimney

Chimney

ve m
these materials ha
Chimney

WIRKUNGSGRAD ABHÄNGIGKEIT
>
> ials are
Bypass

> th e m at er
>
> . Adde d to th is,
stainabilityGroßes
Without bypass and

su mentally
ing them as environ
Heizungsoberfläche
Kapazität Rauchgaskondensator

>
> Boiler Distribution

fully recyclable, mak


Boiler
With bypass and

valve 10
in % von den Kesselleistung

>
>
two chimneys
one chimney

> friendly as possible.


>
> Valves
5 Kleines Heizungsoberfläche
>
>
fase 2 fase 1
>
Fuel-gas side
0
de dérivation

Cheminée

Cheminée
La conduite

Cheminée

20 40 60 80 100 120 140 160 180


The condenserSoupape
de with a built-in bypass channel is suitable for use with the flue
répétition
Temperatur Heizungswasser Rücklauf (°C)
gases produced by gaseous fuels, such as natural gas and propane. In emer-
Operating principle
dérivation intégré

Chaudière Chaudière
gencies, during which a boiler is briefly fueled with oil, the flue gases can be Operating principle
Avec canal à

discharged via the bypass channel, through the flue. In the event of sustained
à dérivation
Sans canal

oil firing and boiler systems that are able to switch between gas and oil fuels, 15
Vannes
a condenser without a flue-gas side bypass channel will be necessary. A valve
EFFICIENCY AS A FUNCTION OF THE COOLING WATER TEMPERATURE
then makes it possible to shut off the supply of flue gases to the condenser.
In this system, both the boiler and the condenser are fitted with a flue (with a Big heating surface
10
valve) for the discharge of flue gases.
in % of the boiler capacity
Capacity of the condenser

Water side Small heating surface


5
The condenser is available as a single condenser with one water circuit or as a
fase 2 fase 1
combi condenser with two water circuits. It is also possible to opt to have the
water side connections on the left or right-hand side.
0
Your process data can be used to produce a heating calculation plus a related 20 40 60 80 100 120 140 160 180

recommendation for the type of condenser and a savings calculation. Temperature of the return (°C)

Principe de fonctionnement

15
he capacité de chaudière

van Dijk heating B.V. - Regulierenring 7, 3981 LA Bunnik - Postbus 29, 3980 CA Bunnik
LE PLUS GRAND RENDEMENT EST OBTENU DE LA MANIÈRE SUIVANTE

Tel: +31(0)30 656 38 44 - Fax: +31(0)30 656 35 64 - Email: info@vandijkheating.nl - Web: www.vandijkheating.nl Grande surface de chauffe
érateur of the

10

Version 1.0 - 2012 | Graphic design © RV Productions 2012. Press errors and omissions excepted.

You might also like