0% found this document useful (0 votes)
278 views4 pages

Lumasense Mikron M67S

The document describes an infrared thermometer that measures temperature from 0 to 2200°C without contact. It has various optics and temperature ranges, outputs a 4-20 mA signal, and is rugged for industrial applications like cement, chemicals, glass, and metals.

Uploaded by

Bruno Santos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
0% found this document useful (0 votes)
278 views4 pages

Lumasense Mikron M67S

The document describes an infrared thermometer that measures temperature from 0 to 2200°C without contact. It has various optics and temperature ranges, outputs a 4-20 mA signal, and is rugged for industrial applications like cement, chemicals, glass, and metals.

Uploaded by

Bruno Santos
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.

IMPAC Infrared Thermometers

Compact Two-wire Infrared Thermometer for Non-Contact Temperature Measurement in


many different applications. Temperature ranges between 0 and 2200°C.

LumaSense MIKRON M67S


• Two-wire Pyrometers with analog output 4 … 20 mA
for connection to standard analyzing instruments

• Through-lens sighting and high quality variable focus


optical system

• Different optics for optimal


match to the application

• Versions with different


spectral ranges

• High accuracy of 0.5%

• Rugged stainless steel design

Universal Application withstand the most punishing condi- Typical applications:


Completely self-contained, the tions found in industry. The Infra-
• Cement
M67S Infraducer can be used as true ducers have universal application in
two-wire temperature virtually any type of industry. • Ceramics
transducer/transmitters which • Chemicals
produce a standard 4-20 mA linear Field Interchangeability
output. Powered by its current Superior design not only ensures • Food
loop, each Infraducer is completely accuracy and long term reliability, • Glass
compatible with any existing instru- it also ensures interchangeability
between Infraducers of the same • Heat treating
mentation for recording or process
control. model with ±0.50% accuracy. • Metals

For especially demanding applica- • Paper


A rugged, stainless steel housing,
miniature size and light weight tions, the Infraducers have a digital • Plastics
make the Infraducer suitable for emissivity control which can be • Power
many applications. To ensure set with a resolution of 0.01. This
ensures that, should one of the • Printing
minimum maintenance and utmost
reliability, the Infraducers have Infraducers need to be replaced, the • Petrochemicals
absolutely no moving parts. replacement unit can be preset in
• Robotics
every aspect before installation.
When contained within its • Rubber
companion cooling jacket and air • Semiconductors
purge assembly, each Infraducer can
• Textiles
• Vacuum systems, etc.
Specifications

The M67S is available with a variety of temperature ranges, spectral responses, and optical characteristics to meet
specific applications. The following chart will give you an overview over the available instrument versions.

Typical Application Temperature Spectral response in Field of Output response time


range in °C µm (spectral code) View Ratio (field adjustable)

0 … 100 8 … 14 (B) 15 : 1
General purpose applications incl. 100 ms
Textile, Printing, Paper, Food, 300 ms
Laminating, Rubber, thick Plastics, 0 … 300 1 sec
Paints, etc. Rejects energy from high 0 … 500 8 … 14 (B) 30 : 1 3 sec
intensity radiant heating sources 100 …1000 10 sec

0 … 300 7.9 (F) 15:1 100 ms


300 ms
Thin plastic films such as Polyester,
1 sec
Flourocarbons, etc. and very thin Glass 100 … 400 7.9 (F) 30 : 1
150 … 600 3 sec
10 sec
100 … 600 4.8 … 5.2 (E) 15 : 1
100 ms
Glass surface measurement
300 ms
applications incl. Bending, Forming,
1 sec
Tempering, Annealing, Sealing & 300 …1300 4.8 … 5.2 (E) 30 : 1 3 sec
Laminating, etc.
10 sec

100 ms
Sees through clean flames & hot
300 …1000 300 ms
combustion gases. Applications incl. Narrow Band
450 … 450 30 : 1 1 sec
Reformer Tubes, Chemical Reactors, centered at 3.86 (D)
600 …1750 3 sec
Kilns, etc.
10 sec

100 ms
Temperature of flame for Combustion 320 …1200
300 ms
and Pollution Industries, Incinerators, 400 …1400 CO² Absortion
30 : 1 1 sec
Utility Boilers, Kilns, Chemical 450 …1900 Band (L)
3 sec
Reactors, etc. 800 …2200
10 sec

525 … 800
Most common for high temperature 600 ... 900 0.78 … 1.06 (H) 90 : 1 50 ms
applications such as Metals, Foundries, 650 ... 1000 300 ms
Hardening, Forging, Annealing, 800 ... 1300 1 sec
Glass Melting Tanks, Glass Gobs and 900 …1600 3 sec
Semiconductor Processes. 0.78 … 1.06 (H) 180 : 1 10 sec
1100 …2000
1500 …3000
220 … 400 50 ms
Medium to high temperature 1.0 … 1.6 (Q) 30 : 1
300 … 600 300 ms
applications for ferrous and non
1 sec
ferrous Metals; sees through Glass; 400 … 800
1.0 … 1.6 (Q) 90 : 1 3 sec
fast response 500 …1100 10 sec

For instruments Reference Numbers please contact your local sales partner!
Technical Data
Measurement Specifications Interface
Resolution: +-0.1% of full scale span (FSS) Connection: Four terminal screws: two for
signal, one for GND, and one
Emissivity ε: Digital setting 0.10 to 0.99 with spare
0.01 step
Parameters (setting): Emissivity from rear panel with
Measurement +- 0.50% of full scale or 1°C digital push button switch
Uncertainty: whichever is greater
Communication
Repeatability: +- 0.2% of full scale span
Analog Output: 4 to 20 mA linear standard
Optical Specifications
Response Time t95: 50 ms for spectral response
Sighting: Eyepiece: Diopter type
0.78-1.06 µm and 1.0-1.6 µm,
Optics: Non-parralax refractive optics for all others: 120 ms
focusable from rear panel
Maximum/Minimum none
Environmental Specifications Value Storage:
Electrical
Protection Class: Nema 4 with Protective/Cooling
Jacket Power Supply: 24 V DC (18 to 40 V DC) nominal
Operating Position: any
Power Consumption: ~0.4w at 20mA
Ambient Temperature: 0 to 60 °C without cooling
Load Resistance Max: 400 ohms for 24 V DC input
Storage Temperature -30 to 80 °C voltage, 1200 ohms for 40 V DC
input voltage
Relative Humidity: 90%, Non-condensing conditions
Hysteresis none
Weight: 0.90 kg
Switch Contact: none
Housing: Stainless steel
Isolation: none
Dimensions: 50 mm diameter x 203 mm long

CE Label: According to EU directives about


electromagnetical immunity

Dimensions
Focus Knob

Terminal Block

Hi-Temp Filter

Specification Label
Eye Piece

Upright Visual Digital


Sighting 4° Emissivity Control M67S Rear Panel

Reticle Defines Exact


Area of Temperature
Measurement for Eye Piece Focusing Knob
Precision Targeting Output (Adjustable from
Termal Strip Rear Panel)
Optics
Optical Resolution – Variable Focus M67S

Three different lenses are available for the M67S. The one you should choose depends on the desired working distance
of the unit. The first version is designed to measure temperature at distances of 350 mm to infinity. The second version
has a working distance of 150 mm to 350 mm. The third version is fixed to measure temperatures at about 25 mm
distance. Proper focusing is achieved by mounting the unit at the desired distance and adjusting the focusing knob on
the rear panel of the instrument until the target comes into clear view in the reticle. When the target is in focus to the
eye, it is also in focus to the detector. Should you wish to move the instrument, remember to stay within the prescribed
working distance, and simply refocus upon the target after mounting the instrument in its new location.

Formula to determine Minimum Target Size: (MTS) = FocussedField


Distance (D) (M67S to target)
of View Ratio

Example: M67S, version 1 with 30:1 FOV focussed at 380 mm

 MTS = D/FOV = 380 mm / 30 = 12,7 mm

Minimum target sizes are shown in the table below:

Field of View Optics Version 1 Optics Version 2* Optics Version 3


FOV Focus 350 mm … infinity Focus 150 mm … 350 mm Focus at 50 mm

15 : 1 Min. target of 23.6 mm at 350 mm Min. target of 10.2 mm at 150 mm Min. target of 3.3 mm at 25 mm
distance distance distance
30 :1 Min. target of 11.9 mm at 350 mm Min. target of 1.8 mm at 150 mm Min. target of 1.5 mm at 25 mm
distance distance distance
90 : 1 Min. target of 4.1 mm at 350 mm Min. target of 1.8 mm at 150 mm Not Available
distance distance
180 : 1 Min. target of 1.8 mm at 350 mm Not Available Not Available
distance
*Only for versions with spectral code L, H, or Q.

Accessories
6 870 010 Protective Jacket J (With Cooling) 6 870 040 6” Aiming Flange P (requires Jacket J or I)

6 870 020 Protective Jacket I (Without Cooling) 3 890 640 DA 4000-N, Digital display, with integrated
2-wire power supply
6 870 030 Air Purge Assembly (requires jacket J or I) 3 890 650 DA 4000, Digital display, with 2-wire-power-supply,
dual limit switch

Accessory Overview

Protective Jacket (J or I) Protective Jacket

Air Purge Assembly


6’’ Aiming Flange

Air Purge Assembly


Digital Display

LumaSense Technologies Awakening Your 6th Sense


Americas and Australia Europe, Middle East, Africa India China
Sales & Service Sales & Service Sales & Support Center Sales & Support Center
Santa Clara, CA Frankfurt, Germany Mumbai, India Shanghai, China
Ph: +1 800 631 0176 Ph: +49 69 97373 0 Ph: +91 22 67419203 Ph: +86 133 1182 7766
Fax: +1 408 727 1677 Fax: +49 69 97373 167 Fax: +91 22 67419201 Fax: +86 21 5039 8096
info@lumasenseinc.com www.lumasenseinc.com
LumaSense Technologies, Inc., reserves the right to change ©2014 LumaSense Technologies. All rights reserved.
the information in this publication at any time. M67S-datasheet_EN - Rev. 02/14/14

You might also like