You are on page 1of 12
Hilti HIT-HY 150 Prana R STS) Hilti HIT-HY 150 with HIT-V / HAS Injection mortar system Benefits a Miia os = Hit HIT-HY 150 330 ml foil pack {also available ‘as 500 ml and 1400 mi foil pack) Static mixer HAS rods HAS-R rods HAS-HCR rods HAS-E rods HAS-E-R rods fa HT. V rods “ sel Ut Rs HITVHOR rods ~ suitable for non-cracked concrete © 20/28 to C 50/60 + suitable for dry and water saturated concrete + high loading capacity ~ rapid curing ~ small edge distance and anchor spacing possible - large diameter applications + high corrosion resistant ~ in service temperature range up to 120°C shor term/72°C long term + manual cleaning for anchor size M8 to M16 and embedment depth hes 104 = embedment depth range M8: 60to 160mm M30; 120 to 600 mm Piha [8] Smalledge Variable Em Ce Fish European gg Fre Coresan Conerte distance embedment Fatigue C2TEBOM— orosion Techical CE, and spacing depth resistance star resistance Approval ormiy Z| Hi anchor esign sofware Approvals / certificates Description ‘Authority / Laboratory No, [date of issue European technical approval * DIB, Berlin. ETA-05/0051 / 2008-10-22 Fire test report MFPA Braunschweig {UB 3027 [0274-6 | 1994-06-30 Assessment report (fire) warringtonfire WF 166402 / 2007-10-26 a) All data given in this section according ETA-05/0051 issue 2008-10-22. 366 72008 ee Lease) PLEAD AS) Basic loading data (for a single anchor) All data in this section applies to For details sce Simplified design method = Correct setting (See setting instruction) = No edge aistance and spacing influence = Steel failure - Base material thickness, as specified in the table = One typical embedment depth, as specified in the table = One anchor material, as specified in the tables = Conerete C 20/25, 25 Nimm? = Temperate range | (min. base material temperature -40°C, max. long term/short term base material temperature: +24°C/40°C) = Installation temperature range -8°C to *40°C Embedment depth *) and base material thickness for the basic loading data. Mean ultimate resistance, characteristic resistance, design resistance, recommended loads. [Anchor size wa [ Mio [ iz | Mie | M20 | M2 | M27 | M30 Typical embedment depth ha Imm] | 80_| 90 | 140 | 125 | 170 | 210 | 240 | 270 Base material thickness h_[mm| | 110 | 120 | 140 | 165 | 220 | 270 | 300 | 340 4) The allowed range of embedment depth is shawn in the setting detalls. The corresponding load values can be calculated according to the simplified design method, Mean ultimate resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8 [Anchor size we [ Mio | iz | M16 | M20 | M2 | M27 | M30 TensiloNan HITVS8 (KN) | 139 | gos | 44a | 75.4 | 1211 | 1689 | 2036 | 237.5 ShearVaun HITVS8 kN | 95 | fee | 227 | ano | ban | 024 | ioe | waz Characteristic resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8 [Anchor size we [Mio [wiz [| Mis | M20 | M2é | M27 | M30 TensileNw HIT-V5.8 [kN] | 180 | 290 | 420 | 565 | 908 | 1267 | 1527 | 178.1 ShearVe HITVS8 kN | 90 | #50 | 240 | 390 | 6x0 | a0 | m150 | n400 Design resistance: non-cracked concrete C 20/25 , anchor HIT-V 5.8 [Anchor size wa | Mio | iz | M16 | M20 | M24 | M27 | M30 Tensile Nas HITVS8 kN) | 120 | 17.3 | 253 | 268 | 432 | 603 | 727 | 948 ShearVes _HITWS8 KN | 72 | 120 | 168 | 312 | 488 | 704 | 20 | 1120 Recommended loads *): non-cracked concrete C 20/25, anchor HIT-V 5.8 [Anchor size we | Mio_[ wiz | Mis | M20 | M2a | M27 | M30 TensileNwe HIT-V58 kN] | 86 | 123 | 181 | 192 | 309 | 431 [ 519 | 606 ShearVne HITVS8 KN | 61 | 86 | 120 | 223 | s49 | 503 | 657 | 80.0 a) With overall partial safety factor for action y = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national regulations. According ETAG 001, annex C, the partial safety factor is ‘te = 1,35 for permanent actions and ya = 1,5 for variable actions. 112008 367 ena Laan} Prana BS AS) Service temperature range Hilt HIT-HY 150 injection mortar may be applied in the temperature ranges given below. An elevated base material temperature may lead to a reduction of the design bond resistance. Base material | Maximum long term 1 Maximum short term Temperature range apart base material ‘base material ‘temperature ‘temperature Temperature range | 40°C to +40°C 424°C +40 °C Temperature range 40°C to +80°C +50°C +80°C Temperature range I 40°C to 120°C 472°C H120°C ‘Max short term base material temperature ‘Short-term elevated base material temperatures are those that occur over brief intervals, e.9. as a result of diurnal cycling, ‘Max long term base material temperature Long-term elevated base material temperatures are roughly constant over significant periods of time. Materials Mechanical properties of HIT-V/ HAS [Anchor size me | Mio[ mi2_| Mie | M20 | M24 | M27 | M30 HTMHASS8 (Nmm| 500 | 500 | 500 | 500 | 500 | 500 | 500 | 500 Nominal “HiTviaS 88 (Nimm*l| 800 | @00_| @00 | 800 | 800 [ 800 | 00 | 600 Sirongth fy HIEMHAS-R_—(Nimm*l| 700 700_[~700_|_700_|700_[ 700 | ~00_| 500. HITMHAS-HOR_[Nimm’]] 800 | @00_| 800 800 | @00_| 700_| 700 | 700 HITMHASS.8 (Nimme]| 400 | 400_[ 400 | 400 | 400_[ 400 400 | 400 Yield “HITHASB.B_[Nimm*]| 640 | 640 | 640 | 640 | 640 | 640 | 640 | 640 strength fy HITVHAS-R__(Nimm®l| 450 | 450 | 450] 450 | 450 | 450 [| 210 | 210 HITMHAS-HGR (Nimm'j| 600 | 600 | 600 | 600 | 600 | 400 | 400 | 400 Stressed HAS immy | 328 | 623 | 762 | 144 | 225 | 24 | 427 | 519 Moment of HAS imm) | 312 | 623 | 109 | 277 | 541 | 935 | 1387 | t874 feestrce amy aww [a0 [sax | oa@ [2a [ara | aoa | sare | 706 368: 172000 ee Lease) PLEAD AS) Material quality Part Material Threaded rod HIT-V(F), HAS 5.8 ‘Strength class 6.8, ENISO 898-1, A, > 8% ductile steel galvanized > 5 um, EN ISO 4042 (F) hot dipped galvanized = 45 ym, EN ISO 10684 Threaded rod HIT-V(F), HAS 8.8 ‘Strength class 8.8, EN ISO 898-1, As > 8% ductile steel galvanized 2'5 ym, EN ISO 4042 (F) hot dipped galvanized 2.45 ym, EN ISO 10884 Threaded rod HIT-V-R, HAS-R ‘Stainless steel grade A4, A, > 8% ductile strength class 70 for s M24 and class 50 for M27 to M30, EN ISO 3506-1, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362, ‘Threaded rod HIT-V-HCR, HAS-HCR High corrosion resistant steel, EN ISO 3606-1, EN 10088: 1.4529; 1.4565, strength S M20: R= 800 Nimm?, Rp = 640 Nimm?, As > 8% ductile M24 to M30: R,, = 700 Nimm?, Ryo = 400 Nimm®, As > 8% ductile ‘Steel galvanized, EN ISO 4042; hot dipped galvanized, EN ISO 10684 Washer ‘Stainless steel, EN 10088: 1.4401, 1.4404; 1.4578; 1.4571, 1.4439; 10 7089 1.4362 High corrosion resistant steel, EN 10088; 1.4529, 1.4565 ‘Strength class 8, ISO 898.2 steel galvanized > 5 yim, EN ISO 4042 ut hot dipped galvanized 2 45 um, EN ISO 10684 ENiso 4032 ‘Strength class 70, EN ISO 3506-2, stainless steel grade Ad, EN 10088: 1.4401; 1.4404; 1.4578; 1.4571; 1.4439; 1.4362, ‘Strength class 70, EN ISO 3506-2, high corrosion resistant steel, EN 10088: 1.4529; 1.4565 Anchor dimensions HIT-V, HIT-V-R, HIT-V-HCR anehor ea [a Anchor tod ~/¢]/2]}8/}@]} e/g] s§ HAS, HAS-R, HAS-HCR g/g | & s & g 8 | 3 HAS-E, HAS-E-R 2/s/s]}]s]/e]/8 ] 8] 8 Embedment depth her [mm] 80 90 110 125 170 210 240 270 Farchor roa ‘Anchor rods HIT-V (-R/-HCR) are available in variable length Setting installation equipment [Anchor size we [Mio [wiz | Mie [M20 | Mzs | M27 [M30 Rotary hammer TE2—TE 16 TE 40-TE70 Other fools ‘compressed air gun or blow out pump, set of cleaning brushes, dispenser 369 Ca Lea A} Pane o Setting instruction Dry and water-saturated concrete, hammer d Marval leaning ae a) 5 IT Compressed ardeanng Fn a) Note: Manual cleaning for element sizes d < 16mm and embedment depth hy < 10 d only! b) Note: Extension and piston plug needed for overhead installation and/or embedment depth > 250mm! For detailed information on installation see instruction for use given with the package of the product. 370 172000 ee Lease) PLEAD AS) Working time, Curing time Temperature Working time curing time of the base material Tow toot tours”! S°CsTow< OC 90min oh OCs Tw< SC 46min a5h SCs Tae 10°C 29min Zh 70°C Toy = 20°C min 20-min 20°C < Tou 30°C 4 min 50-min 30°C Ta = 40°C 2 min 40-min 4) The curing time data are valid for dry anchorage base only. For water saturated anchorage bases the curing times must be doubled. Setting details Marking of the embedment depth Fixture Bore hole depth hy= anchorage depth her, | «e Thickness to, Thickness of concrete member h 112008 371 ena Laan} Prana BS AS) Setting details [Anchor sige weno [eee [ww Nominataiameterot 4, rm] 10 | 12 | a | ae | 2 | 2 | a | a Efedveenbeinertgnd hymn Imi] 60 | 60 | 70 | 80 | 90 | 100 | 110 | 120 dil hole depth range ®” for HIT-V_ Netmax [mm]} 160 200 240 320 400 480 540 600 aie aniorage and sre dean ba tm] 20 | 20 | 110 | 125 | 170 | 210 | 240 | 270 for HAs Winrar base he a0 material thickness nin [mm] 2100 mm he+ 2 do Diameter of clearance paints dtm} 9 | 12 | 14 | te | 22 | 2 | 30 | 33 Torque moment Tmax!” [Nm] } 10 20 40 80 150 200 270 300 Minimum spacing Smn [mm] | 40. 50, 80. 80, 100 120 135. 150 Minimum edse wm] 20 | 50] 60 | ao | 100 | 120 | 105 | 150 Creal spacing {for spliting failure Sse Imm) 2 case 1,0-her for h/ he 2 2,0 . Critical edge distance for2.0>hiha> = {or spliting failure? ae (mmm]] 46 hat 48h for20>h/ha> 1.3 49 1 2,26 her for h/ her S 1,3: areeeocons * se Cilicl spacing fo Concrete cone failure Sex [mmm] 2 ean Crtal edge distance for concrete cone Cem [mm] 1,5 Mey failure? For spacing (or edge distance) smaller than critical spacing (or critical edge distance) the design loads have to be reduced, a) Embedment depth range: Netmin $ Rat S Raima b) Maximum recommended torque moment to avoid spliting failure during installation with minimum spacing andlor edge distance, ©) hr base material thickness (h 2 hyin), Hee embedment depth 4) The critical edge distance for concrete cone failure depends on the embedment depth hand the design bond resistance. The simplified formula given in this table is on the safe side. 372 172000 ee Lease) PLEAD AS) Simplified design method Simplified version of the design method according ETAG 001, TR 029. Design resistance according data given in ETA-05/0051, issue 2008-10-22 + Influence of concrete strength * Influence of edge distance = Influence of spacing "Valid for a group of two anchors. (The method may also be applied for anchor groups with more than two anchors or more than one edge distance. The influencing factors must then be considered for each edge distance and spacing. The calculated design loads are then on the safe side: They will be lower than the exact values according ETAG 001, TR 029. To avoid this, it is recommended to use the anchor design software PROFIS anchor) The design method is based on the following simplification: + No different loads are acting on individual anchors (no eccentricity) The values are valid for one anchor. For more complex fastening applications please use the anchor design software PROFIS Anchor. Tension loading The design tensile resistance is the lower value of ~ Stee! resistance: Naas = Combined pullout and concrete cone resistance: Nrep =N°aap fap fin- fam fan frp fran = Concrete cone resistance: Nrae = N’nae fa faa fan faq fn fe Concrete splitting resistance (only non-cracked concrete): Neaee = Nine fa fran fase Fann tha fran Basic design tensile resistance Design steel resistance Naas [Anchor size wa [Mio | Mi2 | M6 | M20 | M2 | M27 | M30 HAS 5.8 Ten | 113 | 17.3 | 25.3 | 48,0 | 747 | 1067 | 1447 | 175.3 HITV 56 TN] | 12,0 | 19,3 | 280 | 527 | 620 | 1180 | 153.3 | 187.3 HAS 8.8 [en] | 18,0 | 280 | 40,7 | 767 | 1193 | 1707 | 231.3 | 2813 Nea HiV8S TKN] 30,7 | 44,7 | 84.0 | 130,7 | 188.0 | 2447 | 209.3 ts HAS CE) kN] 198 | 283 | 540 | 240 | 1198 | 75,9 | 920 HIV iN | 13.9 | 219 | 316 | 588 | 920 | 1321 | 804 | 983 HAS (E}HCR fen) | 18,0 [28,0 | 40,7 [767 [1200 | 1067 [144.8 [1757 HIT-V-HOR EN | 19.3 | 307 | 447 | 840 | 1307 | 117.6 | 152.9 | 187.1 112008 373 ena Laan} Prana BS AS) Design combined pull-out and concrete cone resistance Nrap = N°rap -fo.p- fun - fan fa - frp maNaroee Mon vscarembednentderth | go | ao | 110 | 12s | vo | 10 | 2 | 270 Nizsp Temperature range! [kN] | 147 | 17.3 | 253 | 269 | 432 | 603 | 727 | 648 Nizsp Temperature range ll (kN) | 101 | 118 | 17.3 | 180 | 280 | 377 | 485 | 606 Nissp Temperature range lll KN] | 87 | 102 | 15.0 | 15,0 | 254 | 339 | 388 | 485 Design concrete cone resistance Nrac = N°rae «fe fi.u «fan: fan fn > fron Design splitting resistance Nrasp = N°rac * fa fisp fasp fap ° fin fron [Anchor size Me_[ Mio [wi2_[ Mie [M20 | waa | Ma7 | NGO Nase tay | 172 | 205 | 277 | 336 | 533 | 732 | 094 | 1067 Influencing factors Influence of concrete strength on combined pull-out and concrete cone resistance Concrete strength designation fev 208) ¢ 20725 | c 25/30 | c 30/37 | c 35/45 | c 40/50 | c 45/55 | c 50/60 fag = _(aene/25Nimm) 100 | 103 | 106 | 108 | 111 | 119 [ 1.14 8) Taaae = Concrete compressive Sirengih, measured on Gubes with 150 mm side length cone resistance Influence of embedment depth on combined pull-out and concret fp = heilhetiye Influence of concrete strength on concrete cone resistance Concrete strength designation ence ¢ 2025 | ¢ 25/30 | c 30137 | c 35/45 | c 40150 | c 48/58 | c 50/60 fs = (eval 25NImme) 1 1 122 | 134 | tat | 148 | 155 anerele compressive strength, measured on cubes with 150 mm side length 8) Chane Influence of edge distance * elecin elesrse fin = 0,7 +0,3:0lmy <1 fap = 0,7 + 0,8 Cleary <1 of | 02) 03 | 04 | 05 | 06) o7 ) 08) 09) 1 073 | 0,76 | 0.79 | 0,82 | 0.85 | 0,88 | 0,91 | 094 | 097 | 1 fan = O.5(1 + loan) <1 faap = O.5(1 + eloars) <1 a) The edge distance shall not 6 smaller than the minimum edge distance 6, These Influencing faotors must be considered for every edge distance smaller than the critical edge distance, 085 | 0,60 | 0,65 | 0,70 | 0.75 | 0.80 | 0.85 | 090 | 095 | 1 Influence of anchor spacing * sisenw iSer00 fay = 0,5(1 + slsern) <1 fap = O5(1 # SlSeran) 1 8) The anchor spacing shall not be smaller than the minimum anchor spacing Sq, This influencing factor must be considered for every anchor spacing 374 172000 o1 | 02 | 03 | 04 | 05 | 06) 07 ) 08) 09) 4 0.55 | 0.0 | 0.65 | 0,70 | 0.75 | 0,80 | 0,85 | 0,90 | 095 | 1 ee Lease) PLEAD AS) Influence of embedment depth on concrete cone resistance fan = (hehetays) Influence of reinforcement Raley En} 50 60 70 0 30 | = 100 fren = 0,5 + h/200mm 5 1 a7 [o7s” | oa” | oes” [ oo” [oss | 4 8) This factor applies only for dense reinforcement. If in the area of anchorage there 1s reinforcement with a spacing 2 150 mm (any diameter) or with a diameter < 10 mm and a spacing 2 100mm, then a factor fey = 1 may be applied Shear loading The design shear resistance is the lower value of Steel resistance: Verde Conorete pryout resistance: Vaden = K- lower value of Nag and Nage Concrete edge resistance: Vage = V'nae fof f fa Frat fe Basic design shear resistance Design steel resistance Vras [Anchor size wa [Mio | mi2 | M6 | M20 | M24 | M27 | M30 HAS 5.8 in| 68 | 104 | 152 | 288 | 448 | 640 | a7.2 | 1056 HITV 56 fen) | 7.2_[ 42,0 | 168 [312 | 4a8 [704 [920 [1120 HAS 6.8 [kn] [108 | 168 | 248 | 464 | 72,0 | 1024 | 1392 | 168.8 Veo, HiEVa8 TN] | 12.0 | 184 | 27.2 | 504 | 7e4 | 1128 | 147.2 | 179.2 s+ HAS (ELR ten [77 [22 | 17.3 [327 [506 [78 [458 [555 HIT-VR EN | 83 | 128 | 192 | 353 | 651 | 795 | 483 | 688 HAS CE}HCR fen) [104 [168 | 248 | 464 [720 | 640 | 69 | 1057 HIT-V-HOR Ten) | 12.0 | 184 | 27.2 | 504 | 7a4 | 709 | 920 | 1120 Design concrete pryout resistance Vru.cp = lower value” of k - Nrap and k - Nrac k= 2 for he 2 60 mm 8) Naas: Design combined pullout and concrete cone resistance Nace: Design concrete cone resistance Design concrete edge resistance Vrac Prac: fa - fa -fh- fa fot - fe [Anchor size wa [| Mio | mi2 | Mis | M20 | M2 | M27 | M30 Non-cracked concrete ae iy 55 | 66 | 16 | te7 | 270 | s66 | 445 | 530 112008 375 ena Laan} Prana BS AS) Influencing factors Influence of concrete strength Concrete strength designation emcee ¢ 205 | ¢ 25/30 | ¢ 30137 | c 35/45 | c 40/50 | c 45/55 © 50/60 fs = (eveun/25NImmry = 1 14 122 | 134 [| 141 | 1.48 1.55 8) foxaue = concrete compressive sirengih, measured on cubes with 150 mm side length Influence of angle between load applied and the direction perpendicular to the free edge [Angie 8 40° [ 20° [ 30° | 40" | so" | 60° | 70° | 80° [2907 v f e\ 1 | 101 | 1,05 | 1,13 | 1,24 | 1,40 | 1.64 2,32 | 2,50 Influence of base material thickness hie 018 | 03 | 045 | 06 [075] 09 | 105) 12 | 135 [218 fe = (u(t5-o)? 31 o2 [045 [0.55 [0.63 [0.71 | 0,77 [024 | 089 [ 095 [ 1,00 Influence of anchor spacing and edge distance “ for concret fa = (clha)"® «(1 +8 / [3 -¢]) -0,5 edge resistance: f, Single Group of two anchors s/hat eth | anchor | 9.75] 450 [225 [3,00 3,75 [4,50 [5,25 | 6,00 [6,75 [7.50] 625 | 900 [3.75 [Toso] Tze 7s [-oss-| 043 ose] oss) 038 ogs| ns) ts] o8s|oss| Oss] O38 oas| bss] es] Oss ar SS5yoaet ose] Tool toot oop top tot tet Teo, Loop vaot ant Tan) an dian bar [ard oot tal asl taeda tanta tel tel fae taeT tas] teeta os foosoftso{ tat tast tot tsola st pao oan pant pan pan >aeLaaoL pol Z ae iss 2on| 225] Za 205| oar] So) 416] 9ae| Sse] ss) 535] S20] 3s) da ta earl oorl zs 21r|- soe] sal Ssel seal spe[ sss] Sas see] sss] Sas] oan an Ban sos Sas sant seal sot til eas( cael ef cast ¢a0{eso{ sao oan 3,25 | 5.86 | 3,15| 3.38) 3.61| 3,83| 4,08| 4,28] 4.51| 4,73| 4.96| 6,18] 5,41| 5.63] 5.86] 5, 86 | 5,86 3,500] 6.55 | 3.51] 3.74] 3,98| 4,21] 4.44] 4.68) 4,91| 5,14| 5.38] 5.61] 5,85] 6,08] 6.31] 6, 3,75 [7.26 | 3.87| 4.12) 4,36] 4,60] 4.84| 5.08] 5,33] 5,57| 5.81] 6,05] 6,29] 6,54| 6.78] 7, 55] 6,55 02] 7.26 4,007] 8,00_| 4,25| 4,50] 4,75| 5,00] 5.25] 5,50] 5,75| 6,00| 6.25] 6,50] 6,75| 7.00| 7,25] 7,50] 7.75| 425 [8.76 | 4,64] 4.90] 5,15] 5.41] 5.67] 5.93] 6,18] 6,44| 6,70| 6.96] 7,22] 7.47| 7.73] 7.99] 8.25] 4,50 | 9.55_[5.04] 5.30] 5,57] 5.83] 6.10] 6,36] 6,63] 6,89| 7.16] 7.42| 7,69] 7.95] 8.22] 6.49] 8.75] 4,75, 5.45| 6.72 | 5,99| 6,27| 6.54| 6,81| 7,08] 7,36| 7.63| 7,90| 8,17| 8.45| 6.72 8,99] 9,26 5,00 5.87] 6,15| 6,43] 6,71] 6.99] 7,27| 7,55] 7,83| 6,11] 8,39| 8.66] 8.94] 9.22| 9,50] 9,78 5.25 6,30] 6,87| 7.16| 7.45| 7,73] 8,02| €.31| 859] 8,68] 9,17| 9.45] 9.74] 10,02] 10:31 5,50. 7,33] 7,62| 7,92] 8.21| 8,50] 8,79| 9.09] 9,38] 9,67] 9.97 | 1026] 10.5] 10,5| 1a) The anchor spacing and the edge distance shall not be smaller than the minimum anchor spacing Sy, minimum edge distance Cran 376 iv and the 172000 ee Lease) PLEAD AS) Influence of embedment depth held *[4 [ses .e [7]8)] 9s |] frar= 0,05 - (hor 4) ost [ 063 [075 [1.01 | 431 | 164 [ 200 | 230 | 261 held 2] 3 || s [1 | 7 | 1 [18 | 20 frat = 0,08 (has Fe)" 325 [ 372 | 421 | 473 | 527 | 5.84 | 642 | 7.04 | 7.67 Influence of edge distance * eld as [0] 8 | 2] 0 | «0 f= (doe or [om | os7 | 065 | 060 | 057 | 052 | 050 4) The edge distance shall nat be Smaller than the minimum edge distance Gn, Combined tension and shear loading For combined tension and shear loading see section “Anchor Design” 377

You might also like