You are on page 1of 2

Optima HX Series

TM

High Performance UV Systems

Efficient and cost effective, the Optima HX provides proven performance


and technology in numerous application such as Food & Beverage,
Life Sciences and Microelectronics.

SHOWN

Optima HX
TM
Utilized for ozone destruction and
1350 disinfection, the Optima HXTM is
not only cost effective, but proves
to be a reliable, innovative and
environmentally smart alternative.
I NDUSTRIES | Food & Beverage, Life Sciences,

FLOWRATES: 40-1300GPM @ 94%UVT,

APPLICATIONS
While disinfection is the most common
45-1400GPM @ 99%UVT

application for ultraviolet (UV) technology in


Microelectronics

water treatment, ozone destruction is also


used. Prior to point-of-use, the residual ozone
needs to be destroyed to ensure the process
water is not compromised. After considering
the appropriate variables, a properly sized UV
unit can be guaranteed to destroy the ozone to
non-detectable limits, ensuring the integrity of
the process and product.

SAFE & EFFECTIVE


UV does not ‘add’ anything to the water stream
such as undesirable color, odor, chemicals,
taste or flavor, nor does it generate harmful
TM
by-products. UV only imparts energy to the
OPTIMA HX SERIES
DE S I G N CA PA B I L I TI ES | Cu sto m C o nf ig u r a ti o n s

water stream in the form of ultraviolet light to


The Optima HX series was designed with a sophisticated sizing program,
TM

inactivate micro-organisms or reduce chemical


combining Multiple Source Summation (MPSS) and Computational Fluid compounds present in the water.
Dynamics (CFD), critical in calculating fluency rates, flow patterns and
A PPL I C ATI O N S | D is in fect io n

velocity distribution.
For questions regarding your application needs,
The series consists of 316L stainless steel treatment chamber and a please contact your local Authorized Distributor
stainless steel control panel in one integral unit for models with reactors or Aquafine Corporation for more information.
up to 8” in diameter. Models HX 02BDSU and above have a standard UL
TYPE - 1 painted carbon steel control cabinet.

With low-pressure high-output lamp (LPHO) technology, the HX lamp


provides increased process performance and extended lamp life, while
the systems compact size allows for a smaller footprint, maximizing
installations flexibility. Single-ended (SE) HX lamps allow quick change-outs
without tools.
60 Years of Pure Quality
Optima HX Series
TM

High Performance UV Water Treatment System


Specifications:
Model: Optima HX T M 02 ADS 02 BDS 02 CDS 02 BDL 02DDS 02CDL 02DDL 04 CDL 06 CDL 05 DDL 06 DDL 08 DDL 08 EDL 08 FDL 08 GDL 10 GDL 12 GDL

M A X I M U M FLOW RATE

D I S I N F E C T I ON (@94% UVT) 40 60 78 90 130 175 251 335 415 500 550 670 800 925 11 0 0 1300
G P M ( m 3 / hr)* (9) (14) (18) (20) (30) (40) (57) (76) (94) ( 11 4 ) (125) (152) (182) (210) (250) (295)

D I S I N F E C T I ON (@99% UVT) 45 71 90 11 5 150 220 300 405 520 626 700 850 1070 1200 1400
N/A
G P M ( m 3 / hr)* (10) (16) (20) (26) (34) (50) (68) (92) ( 11 8 ) (142) (159) (193) (243) (273) (318)

N umber of UV Lamps (HX SE) 2 4 6 5 6 8 10 12

E L E C T R I C A L REQUIREMENTS

E lectrical S upply 1 2 0 / 2 4 0 V / 5 0 - 6 0 H z , S ing l e Phase , 2 W + G N D

O per . power (NOMINAL WATTS) 276 360 276 360 600 840 768 840 111 6 1380

B A L L A S T TY PE ELEC T R O NIc

Controller /DETECTOR

U V V I S I O N 2000 G400 SERIES N/A opti on for R EM O TE ( “ U ” ) M O DEL O NLY O P TI O N A L

U V T E M P. & M onitoring S Y STEM O P TIO N AL

L A M P S TAT US INDICATOR S TA N D A R D

Lamp out alert (LOA) O P TIO N AL

Running time meter S tandard

H A N D / O F F / AUTO (HOA) NA O P TIO N AL

4 - 2 0m A output signal Opt ional

C O N T R O L CABINET

Cc s ystem rating C . S - UL Type 1 , S . S . - u l Type 3 R for REmote “ U ” only C . S - UL Typ e 1 , S . S . - u l Typ e 3 R

M AT E R I A L S OF CONST. STD / “U” 3 0 4 S . S . / c. S . , O P TIonal 3 0 4 S . S C . S . , O P TI O N AL 3 0 4 S . S

T R E AT M E N T CHAMBER

M aterials of construction 3 1 6L Stai n l ess ste e l

I N T E R N A L SURFACE FINISH R a 3 2 ( R a 1 5 optional )

O perating temperature ° F (° C) Wa t e r : 4 1° - 1 0 4 ° ( 5 ° - 4 0 ° ) A m b i e n t A i r : 3 4 ° - 1 0 4 ° ( 1 ° - 4 0 ° )

Max . Oper . P ressure PSI (Bar ) 150 (10)

I nlet/ O utlet FLANGE inches ( mm) 2 (50) 3 (80) 4 (102) 6 (150) 8 (200)

Hot water sanit. ° F (° C) 1 7 0 ° ( 7 7° ) AVAILA BLE WIT H S . S . C O M P. N U T S O NLY

S A N I TA RY FITTINGS O P TIO N AL

D I M E N S I O NS - for reference only

20.50 X 15 x 15 x 15 x 21.50 x 22 x 24 x 27 x 44.50 x 46.50 x


OV E R A L L D IMENSIONS INCHES
38.50 x 40 x 40 x 52 x 40 x 68 x 68 x 22 x 68 x 10 2 4 x 6 8 x 11 68 x 67 x 67 x 48.50 x 67 x 18.50
HXWXD
7 12 13.50 12 15.50 10 11 12 14.50 16.50

521 x 366 x 364 x 366 x 540 x 556 x 607 x 679 x 11 2 1 x 11 7 4 x


OV E R A L L D IMENSIONS (MM)
968 x 1010 x 1012 x 1321 x 1010 x 1721 x 1721 x 556 x 1721 x 254 610 x 1721 x 280 1721 x 1702 x 1702 x 1223 x 1702 x 464
HXWXD
176 300 338 300 387 254 274 298 362 413
* Dose Level: 30 mJ/cm2 after 9,000 hours of operation. All specifications are subject to change without notice. For additional requirements, please contact Aquafine Corporation.
0 Years o
ing 5 fS
rat
ISO

eb

er
North America & International Europe

Cel

vice
9001:2000
Certified
29010 Ave Paine, Valencia, CA 91355 Ramskamp 77-85 D-25337 Elmshorn, Germany
A TROJAN TECHNOLOGIES COMPANY
p. 661-257-4770 f. 661-257-2489 p. +49 (4121) 57806-13 f. +49 (4121) 57806-30
www.aquafineuv.com sales@aquafineuv.com
tf. 800-423-3015 (within domestic U.S.A. and Canada)
Printed in USA. © Aquafine Corporation 2009. All rights reserved. This document is not to be copied, electronically stored or reproduced without written permission from Aquafine Corporation. TSG 101I-09