You are on page 1of 4

Infant Incubator

nice-3010-H
An infant's smile is infinitely precious.
The newborn is not just a bundle of joy. It's a beautiful example of hope and wonder,
and life itself. To protect it during the critical neonatal stage, and see it glowing with
health is a labour of love. Neotech infuses the same warmth and dedication into its
effort in making the finest neonatal intensive care equipment.
Neotech Incubators, made to international standards, embody Precision, Reliability
and Convenience.

Micro-processor Control
Ensures accurate monitoring of climate
within the incubator. Guarantees maximum
patient-safety.

Clear text display of operating and


alarm situation
Permits immediate assessment of the
operational status while concentrating
entirely on the newborn. Canopy with unique hinging system

Detachable Control Unit Withdrawable baby-tray


Facilitates quick exchange of control unit, Gives unimpeded access to the newborn.
thus minimizing downtime.
Large front door
Facilitates daily routine work
Touch-operated, liquid-proof foil
and access to the newborn.
Control Panel
Allows fast, easy and hygienic disinfection. Separate X-ray cassette
compartment
Simultaneous Skin, Air and Ensures accuracy and reduces Withdrawable baby-tray with large
Set Temp Display exposure time. front door
Indicates newborn's skin temperature Self-supporting tube
and the actual surrounding air temperature. and lead apertures
Facilitate fast and safe insertion
Memory back-up of tubes and cords for patient-
Helps restore set temperature monitoring and therapy.
and control mode automatically
(in the event of power failure) Canopy with hinges
Enables easy cleaning
Programmable Mute Time inside the incubator.
2- 20 min. range offers greater Humidity Control Chamber and
flexibility and reliability. All operating and Micro air filter
control elements on the front
Soft cable skin-sensor Enable quick and easy operation.
Guarantees uninterrupted, reliable
functioning in the event of small radius
Single-mould
of bend in sensor cable.
5 elbow-operated ports
Allows easy access and eliminates
Stand with swivel-utility rails cross-infections.
and monitor console
Affords easy-to-read and accessible Micro Air Filters
arrangement of all vital monitors. Prevents entry of microbes
through air inlets.
Externally-operated trendle Electrical adjustment of working height
and fowler positioning Electrical adjustment of working height
Allows immediate shockless adjustment Enables efficient, convenient
of the bed-angle to the medical care of the newborn.
requirements of the newborn.
Built-in, integrated Oxygen Flow meter
Helps regulate dry oxygen inflow
Maximum bed dimensions into the incubator (optional)
Provide optimum work-area
for nurses, thus maintaining
comfort of the newborn. X-ray scaling and
Catheter-measuring Scale
12 Humidity Control Chamber Affords convenience and
Helps maintain humidity inside the incubator. helps save time.(optional)
Designed for easy cleaning and draining.
Built-in Observation Light 2 separate base cabinets Central supply bronchial aspirator,
Enables easy examination For compartmentalized accommodation Venturi slow suction and flow meter
of the newborn. of all necessary nursing equipment, with humidifier jar (optional)
and other important items.
Electrical
Electrical connection : Ac 230 V, 50 Hz, 3A ALARMS (acoustical and optical)
Max Power rating : 370VA +/-10% ·Skin temperature low
600VA +/-10% (Variable height) ·Skin temperature high
Heater power rating : 300VA ·Air temperature high
Electronics : Micro controller with self test ·Air temperature low
function ·Air failure (Fan failure)
Incubator control Modes : Servo Air and Servo Skin ·Air flow failure (Due to blocked filter or mechanically stuck fan)
Mute Time : 2 min - 20 min programable ·Heater failure
Co2 level with in the Hood : Less than 0.8% when mixture of Co2 in air is delivered at ·Air Probe failure
750ml /min at a point 10cm above the center of mattress ·Skin Probe failure
Temperature Accuracy ·Temperature > 39o in any mode
Air mode : Accuracy + _ 0.2oC ·Power failure
Skin mode : Accuracy + _ 0.2oC ·system failure
Max. temperature : 39oC Safety
Warm-up time : 25 - 35 min per 10oC (at 23oC Ambient temperature) Heater is electronically cut off
Initial Temp overshoot : <0.5oC if air/skin temperature inside incubator exceeds 39.0oC
Temperature uniformity : <0.8oC IEC 60601-1 Specification
Sensor : Thermistor Type of protection against electric shock : Class 1
Probe interchangeability : Accuracy +_ 0.2oC (calibration not required) Degree of protection against electric shock : Type BF (skin probe)
Noise level inside Type B (Mattress)
incubator : <50 db Mode of Operation : Continuous
Air velocity over the bed : <10 cm/sec ( at 10cm above the center matress) Protection against Hazardous of Explosion : Not Protected
Relative humidity : >80% at 10 cm over bed center Protection against increases of liquid : Not Protected
Air filter capacity : 99% (0.5 ) MDD Product Classification : Class llb
Air intake volume
with filter : 25 l/min Environmental
Air intake volume Operating Temperature : 100 C to 300 C
without filter : 250 l/min Operating Relative Humidity : 15 to 90% RH non condensing
o
Bed tilting : +_ 8 infinitely variable Storage Temperature : -100 C to 600 C
Height adjustable (Electrical) : from 900 mm to 1210 mm Storage Relative Humidity : 50 to 90% RH non condensing
Altitude : Sea level to 1.9 miles (3 kms)

SET TEMPERATURE RANGE Quality/Test approval


o o
Air mode : 30 C to 37 C Quality : ISO 13485:2016
o o
37.1 C to 39 C temperature Electrical safety : IEC 60601-1
override mode : IEC 60601-2-19
o o
Skin mode : 32 C to 37.5 C EMC Safety : IEC 60601-1-2
o o
37.6 C to 39 C temperature
DIMENSIONS/WEIGHT
override mode Overall width : 960 mm
Overall height :1290 mm - 1480 mm
OXYGEN CONCENTRATION Height of bed : 900 mm - 1090 mm
Oxygen input 5 lpm : 25% to 45% 02 Overall depth : 595 mm
Oxygen input 10 lpm : 35% to 65% 02 Dimensions of bed : 700 mm x 400 mm
Oxygen input 15 lpm : 45% to 70% 02 Weight : 110 kg
Castors : 4” diameter antistatic
Humidification : Low/high <80%
(2 locking and 2 non-locking)
IV Maximum load : 1.5 kgs
Maximum monitor load : 3.0 kgs
Maximum baby weight to be : 8.0 kgs

Optional Accessories

.Vacuum regulator for slow

74-00-006, Rev 02
suction control.

.Venturi slow suction

This model comes without .oxygen flow meter with


height-adjustment facility. humidifier jar.

nice 3010

AN ISO 13485:2016 Company(with design)

Regd.Office & Factory:# 85 Krishna Industrial Estate, Mettukuppam,


Vanagaram, Chennai - 600 095 India
Tel:+91-44-24762594,+91-44-24764608 Fax: +91-44-24766920,
e-mail info@niceneotech.com Web: www.niceneotech.com

You might also like