Professional Documents
Culture Documents
K-20
LCD Timer(Touch Type)
Specifications (A)
Photoelectric
Sensors
Model LE4S LE4SA
(B)
Repeat error Fiber
Optic
Sensors
Setting error Max. ±0.01% ±0.05sec. (Power ON Start)
Max. ±0.01% ±0.05sec.
Voltage error Max. ±0.005% ±0.03sec. (Signal ON Start) (C)
Door/Area
Sensors
Temperature error
(D)
Insulation resistance 100MΩ (at 500VDC megger) Proximity
Sensors
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 1hour
Vibration (F)
Rotary
Malfunction 0.5mm amplitude at frequency of 10 to 55Hz (for 1 min.) in each X, Y, Z direction for 10 min. Encoders
Approval
(H)
Temperature
Unit weight Approx. 98g Controllers
(I)
(J)
Counters
6 70 ● Panel cut-out
56
(K)
48 2 Min. 65 Timers
(L)
Panel
Meters
45 +0.6
0
(M)
Min. 65
Tacho /
44.8
56
Speed / Pulse
45 +0.6
0
Meters
(N)
Display
Units
(O)
Sensor
※Refer to page G-19 for 8-pin socket (sold separately). Controllers
(P)
Switching
Mode Power
● Bracket and mounting Supplies
(Q)
Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
※Insert product into a panel, fasten (S)
bracket by pushing with tools as Field
Network
shown above. Devices
(T)
Software
K-21
LE4S Series
Connections
LE4S
RESET 4 5
- + 24-240VAC 50/60Hz
SOURCE 24-240VDC
LE4SA
● [ON.D] [ON.D.II] [FK] [FKI] [INT] [T] [T.I] mode
4 5
3 6 CONTACT OUT:
250VAC 3A RESISTIVE LOAD
2 7
1 8
(Instantaneous (Time limit (Time limit contact 1c)
contact 1c) contact1c)
- + 24-240VAC 50/60Hz
SOURCE 24-240VDC
● [ - ] mode
4 5
3 6
CONTACT OUT:
Contact 2 7 Contact
250VAC 3A RESISTIVE LOAD
(Time limit contact 1a) (Time limit contact 1a)
1 8
- + 24-240VAC 50/60Hz
SOURCE 24-240VDC
K-22
LCD Timer(Touch Type)
Input Connections (A)
Photoelectric
Sensors
LE4S is No-voltage input (Short-circuit and open) type.
(B)
Fiber
Solid-state input Contact input Optic
Sensors
+ + START
START RL START (D)
- - RESET
RESET RESET S1 Proximity
Sensors
INHIBIT INHIBIT S2 INHIBIT
Q1 Q2
S3 (E)
Input 0V Input 0V Input 0V Pressure
Sensors
● Q1 is ON: Operating ● Q2 is ON: Operating ● S1, S2, S3 are ON: Operating (F)
Rotary
● Sensor: NPN open collector output ● Sensor: NPN universal output ● Please use reliable contact Encoders
(H)
Temperature
Controllers
● Time unit
It displays the time unit. (K)
Timers
● Output display (h:hour) (m:min.) (s:sec.)
It displays the status ※When the time is progressing, it
of output contact. is flashing at a rate of (0.5sec.) (L)
Panel
Meters
(N)
Display
● Operation mode Units
● UP/DOWN
It displays the current operation mode.
It displays time progressing
(ex: OND=ON Delay) (O)
UP (▲), DOWN (▼). Sensor
Controllers
(P)
● SHIFT key Switching
● Key lock display Used for advancing to setting time change Mode Power
Supplies
It displays the status mode and moving to each digit.
of key lock. (Q)
Stepper Motors
& Drivers
& Controllers
(T)
Software
K-23
LE4S Series
Function And Time Setting
Configuration
Power On
Setting time
Reset key change mode
key
key
RUN mode
key
for 3sec. while pressing key
Checking
Function key output
setting mode for 3sec. contact status
● Reset
Reset using key in Run mode
● Run mode
The operation status (When power is on for the first time: factory default setting) is displayed.
It could enter into function setting mode, setting value change mode and output contact status mode.
※If no key is pressed over 60 sec. in setting time change mode, it will return to Run mode and previous parameter
value is not stored.
K-24
LCD Timer(Touch Type)
Function Setting Mode (A)
Photoelectric
Sensors
LE4S
(B)
Function setting mode Fiber
Optic
Sensors
2)Time range
(C)
[OND], [ONd1], Door/Area
key Sensors
[ONd2], [INT],
1)Output operation 3)One-Shot output time
mode [INt1], [OFD]
(D)
mode Proximity
key 3sec. key key Sensors
※ONd2
(E)
mode Pressure
RUN mode
Sensors
7)Key lock key tOFFTime range tON Time range
(F)
[FLK], [FLk1], key key Rotary
Encoders
[NFD], [NFd1]
key 3sec. mode
(G)
Connectors/
key Sockets
6)Backlight On/Off 5)Min. input signal 4)Time Up/Down
(H)
key key Temperature
Controllers
(I)
SSRs / Power
Controllers
LE4SA
(J)
Function setting mode Counters
2)Time range
(K)
Timers
(R)
key key Graphic/
Logic
Panels
(S)
Field
Network
Devices
Factory Default
(T)
LE4S LE4SA Software
K-25
LE4S Series
Output Operation Mode
● LE4S/LE4SA output operation mode
1) In function setting mode, it enters into output operation mode as shown in the [Fig. 1].
2) Select proper output operation mode using and key.
(Refer to Output operation flowchart)
3) Press key to set output operation mode and move to next mode.
4) If pressing key for 3 sec. in any function setting mode, it will return to Run mode.
[Fig.1]
K-26
LCD Timer(Touch Type)
Time Range (A)
Photoelectric
Sensors
-Time range[tRNG]
(J)
: OND, ONd1, ONd2, INT, INt1, OFD mode Counters
(M)
Tacho /
Speed / Pulse
Meters
3) Press key to complete the time range setting and the next mode. (Q)
Stepper Motors
4) If pressing key for 3 sec., it will return to Run mode. & Drivers
※When FLK, FLk1, NFD, NFd1, S-D, TWN, TWn1 time range[T!RG, T@RG or & Controllers
(S)
Field
Network
※Time range flowchart Devices
(T)
Software
K-27
LE4S Series
● One-shot output time setting
When output operation mode ON Delay 2[ONd2],
1)In function setting mode, if it enters into One-shot output time setting mode as shown in
the [Fig. 2], the last digit will flash.
2) Set One-shot output time using and key. (setting range: 0.01s to 99.99s)
3) Pressing key to complete one-shot output time setting and move to the next mode.
4) If pressing key for 3 sec. in any function setting mode, it will return to Run mode.
key
key
3) Press key to complete UP/DOWN setting and move to the next mode.
4) If pressing key for 3sec. in any function setting mode, it will return to Run mode.
[Fig.3] ※Factory default
key
key
3) Press key to complete input signal width and move to the next mode.
[Fig.4]
4) If Pressing key over 3 sec. in any function setting mode, it will return to Run mode.
※Factory default
1) In function setting mode, if it enters into output contact setting mode, the characters will
be
displayed as shown in the [Fig. 5].
2)Select time limit 1c+instant limit 1c or time limit 2c using , keys.
(Refer to LE4SA Connections on page K-22 for output contact connections)
key
key
[Fig.5] 3) Press key to complete output contact setting and move to the next mode.
※Factory default 4) If pressing key for 3 sec. in any function setting, it will return to Run mode.
※Except for Star-Delta, Twin and Twin 1 modes (2C is set automatically)
※If pressing key in Run mode, output contact setting value will be displayed.
(If no key is pressed over 3 sec., it will enter into function setting mode.)
K-28
LCD Timer(Touch Type)
● Backlight ON/OFF setting (A)
Photoelectric
1) In function setting mode, if it enters into Backlight ON/OFF setting mode, the characters Sensors
key
(C)
Door/Area
key Sensors
3) Press key to complete Backlight ON/OFF setting and move to the next mode. (D)
Proximity
Sensors
[Fig.6]
4) If pressing key for 3 sec. in any function setting mode, it will return to Run mode.
※Factory default (E)
Pressure
Sensors
● Key Lock setting
1) In function setting mode, if it enters into Key Lock setting mode, the characters will be (F)
Rotary
displayed as shown in the [Fig. 7]. Encoders
3) Press key to complete key lock setting and move to the next mode.
4) If pressing key for 3 sec. in any function setting mode, it will return to Run mode. (K)
Timers
※Factory default for LE4S is lOFF and Factory default for LE4SA is LOc1.
※Key Lock function (L)
Panel
Meters
Display Function
lOFF Turns off the key Lock mode. (M)
Tacho /
Speed / Pulse
LOc1 key cannot be used. Meters
(O)
Sensor
Setting Time Change Controllers
Please set operation time according to following instruction as the setting is different depending on the output operation (P)
Switching
mode. Mode Power
Supplies
● Output operation mode: OND, ONDⅠ, ONDⅡ, INT, INTⅠ, OFF D (Q)
(LE4SA does not have no ONDⅠ, INTⅠ, OFF D.) Stepper Motors
& Drivers
& Controllers
(R)
Graphic/
Logic
Panels
(S)
Field
Network
Devices
(T)
Software
K-29
LE4S Series
● Output operation mode: FK, FK I
※It is able to change the setting time during the time progressing, but be sure about the time progressing while changing
of the time.
※If pressing key while setting time is shorter than min. setting time, setting value will be flickering three times and it will
be returned to setting mode again, not to RUN mode.
※If there is no additional key operations in 60 sec. after entering into setting mode, it will be return to RUN mode. (set
value is not stored.)
※Min. setting time: 0.01 sec.
(In case of: OND, ONd1, ONd2 modes, it is able to set "0" since no min. setting time is applied.)
K-30
LCD Timer(Touch Type)
LE4S Output Operation Mode T = Setting time, T > Ta (A)
Photoelectric
Mode Time chart Operation Sensors
T T Ta T
[OND] (B)
POWER Fiber
Optic
OND START
Sensors
RESET ② ③
RELAY OUT ① ④
(C)
Setting time POWER Door/Area
Sensors
UP 0
Setting time START
T
DOWN 0 RELAY
(D)
ON Delay OUT Proximity
1. Timing operation starts when START signal is ON at status of power on. Sensors
2. Output will be ON when timing operation is progressed up to the setting time. Display value will be
HOLD. (① position) (E)
3. When RESET signal is ON, display value and output will be reset. (② position) Pressure
Sensors
T > Ta 4. If RESET signal is OFF while START signal is ON,“STEP 1”will be restarted. (③ position) T = set time
5. When START signal is OFF, display value and output will be reset. (④ position)
[ONd1] T T Ta T (F)
POWER Rotary
Encoders
ONDⅠ START ②
RESET ③
(G)
RELAY OUT ① Connectors/
POWER
Setting time Sockets
UP 0 RESET
Setting time START (H)
T Temperature
ON Delay 1 DOWN 0 RELAY Controllers
OUT
1. Timing operation starts when START signal is ON at status of power on.
2. Output will be ON when timing operation is progressed up to the setting time. Display value will be (I)
HOLD. (① position) SSRs / Power
Controllers
T > Ta 3. Even though START signal is applied repeatedly, only the initial signal is recognized. (② position) T = set time
4. When RESET signal is ON, display value and output will be reset. (③ position)
[ONd2] T T Ta Ta T (J)
Counters
POWER
START ②
ONDⅡ
RESET
(K)
RELAY OUT ① Timers
Setting time
UP POWER
0
(L)
Setting time START Panel
DOWN Tout Meters
0 RELAY
ON Delay 2 T
1. Timing operation starts when START signal is ON at status of power on. OUT
(One-shot output) (M)
2. Time limit output will be ON and goes OFF during Tout setting time when timing operation is progressed Tacho /
up to the setting time. Display value will be HOLD. (① position) Speed / Pulse
Meters
3. When RESET signal is ON, display value and output will be reset.
4. If START signal is applied while time is progressing, Timing operation will be reset and started again. (② Tout = output time
(N)
T > Ta position) T = set time Display
5. Tout setting range: 0.01 sec to 99.99 sec. Units
K-31
LE4S Series
LE4S Output Operation Mode T = Setting time, T > Ta
Mode Time chart Operation
T T Ta T
[INT]
POWER
INT START ②
RESET
RELAY OUT ①
Setting time POWER
UP 0 START
T
Setting time
RELAY
Interval DOWN
0 OUT
1. Output will be ON when START signal is ON at status of power on and Timing operation starts.
2. Output will be OFF when timing operation is progressed up to the setting time. Display value will be HOLD.
3. When RESET signal is ON, display value and output will be reset. (① position)
T > Ta 4. If RESET signal is OFF when START signal is ON,“STEP 1” will be restarted. T = set time
5. When START signal is OFF, display value and output will be reset. (② position)
T Ta T T T
[INt1]
POWER
INTⅠ START
RESET ① ②
RELAY OUT
Setting time POWER
UP START
0
Setting time T T
RELAY
Interval 1 DOWN 0 OUT
1. Output will be ON when START signal is ON at status of power on and Timing operation starts.
2. Output will be OFF when timing operation is progressed up to the setting time. Display value will be HOLD.
3. Even though START signal is applied repeatedly, only the initial signal is recognized. (① position)
4. If START signal is ON after timing operation is progressed up to the setting time, Output will be ON and setting
T > Ta time will be reset and then timing setting starts. T = set time
5. When RESET signal is ON, display value and output will be reset. (② position)
Ton Toff Ta Ta Toff Ta Ton Ta Ton Toff
[NFD]
POWER
ON OFF D START
RESET ① ②
RELAY OUT
Setting time ON Delay
OFF Delay POWER
UP
0 START
ON Delay
Setting time OFF Ton Toff
Delay
DOWN RELAY
ON-OFF Delay 0 OUT
1. If START signal is ON when power is on, Output will be ON when timing operation is progressed up to the Ton
setting time (On-Delay). IF START signal is OFF, output will be ON when timing operation is progressed up to
the Toff setting time (OFF-Delay).
2. If START signal is applied repeatedly, output is ON and display value will be reset. (① position)
3. When RESET signal is ON, display value and output will be reset. When RESET signal is OFF while START
T > Ta signal is ON, it will be operating as On-Delay. (② position) Ton, Toff = set time
4. It is able to set each Toff time and Ton time separately.
Ton Toff Ta Ta Toff Ta Ton Ta Ton Toff
[NFd1] POWER
ON OFF DⅠ START
RESET ① ②
RELAY OUT
Setting time ON Delay
OFF Delay
UP POWER
0
Setting time ON Delay START
OFF Delay
DOWN Ton Toff
0 RELAY
ON-OFF Delay 1 1. If START signal is ON when power is on, timing operation starts. Output will be ON when timing operation is OUT
progressed up to the Ton setting time (On-Delay). IF START signal is OFF, output will be ON when timing
operation is progressed up to the Toff setting time (OFF-Delay).
2. Output will be ON when START signal is ON and goes OFF during setting time and display value will be reset. (① position)
3. Output will be OFF when START signal is OFF and goes ON during setting time and display value will be reset. (① position)
4. When RESET signal is ON, display value and output will be reset. When RESET signal is OFF while START
T > Ta signal is ON, it will be operating as On-Delay. (② position) Ton, Toff = set time
5. It is able to set each Toff time and Ton time separately.
Ta T Ta Ta T
[OFD]
POWER
OFF D START
RESET
RELAY OUT POWER
Setting time
START
UP 0 T
RELAY
OFF Delay Setting time OUT
DOWN 0
1. If START signal is ON when power is on, output will be ON.
2. When START signal is OFF, timing operation starts. Output will be OFF when timing operation is progressed up
T > Ta to the setting time. Display value will be HOLD. T = set time
3. When RESET signal is ON, display value and output will be reset.
※Initial status: UP mode-display value is "0", output is "OFF". DOWN mode-display value is "setting time", output is "OFF".
K-32
LCD Timer(Touch Type)
LE4SA Output Operation Mode T = Setting time, T > Ta, Rt = Reset time
(A)
Photoelectric
Sensors
Mode Time chart Operation
[OND] T Rt T T (B)
Fiber
POWER Optic
OND ※RESET Sensors
Time limit contact
(⑧-⑥)
Instantaneous contact (C)
(①-③) Door/Area
Setting time POWER Sensors
UP
0 T
Time limit (D)
Setting time contact Proximity
ON Delay DOWN 0 output Sensors
POWER
FK ※RESET (L)
Time limit contact Panel
(⑧-⑥) Meters
Instantaneous contact
(①-③)
Toff (M)
Ton POWER Tacho /
Speed / Pulse
UP Meters
0 Toff Ton Toff Ton
Time limit
Flicker Toff
contact
Ton
(Toff operation DOWN output
(N)
Display
precedes) 0 Units
1. Control output will be repeatedly OFF during Toff setting time and will be ON during Ton setting time when
power is ON. Ton, Toff = set time (O)
Ton, Toff > Ta 2. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes Sensor
OFF when power is OFF. Enables to set Ton and Controllers
3. If pressing RESET key, display value and time limit output will be reset. Toff time differently.
4. It is able to set each Toff time and Ton time separately. In [ ] mode, timing operation starts with Toff. (P)
Switching
[FLk1] Ton Toff Ton Toff Ton Ta Rt Ton Toff Ton Toff Mode Power
Supplies
POWER
FKⅠ ※RESET (Q)
Time limit contact Stepper Motors
(⑧-⑥) & Drivers
& Controllers
Instantaneous contact
(①-③)
Toff (R)
Ton POWER Graphic/
UP Logic
0 Ton Toff Ton Toff Panels
Time limit
Flicker 1 Toff
Ton contact (S)
(Ton operation DOWN output Field
precedes) 0 Network
Devices
1. Control output will be repeatedly ON during Ton setting time and will be OFF during Toff setting time when
power is ON. Ton, Toff = set time
2. If selecting time limit 1c + instantaneous 1c mode, instantaneous output will be ON when power is ON and goes (T)
OFF when power is OFF. Enables to set Ton and Software
3. If pressing RESET key, display value and time limit output will be reset. Toff time differently.
4. It is able to set each Ton time and Toff time separately. In [ ] mode, timing operation starts with Ton.
※Initial status: UP mode-display value is "0", output is "OFF". DOWN mode-display value is "setting time", output is "OFF".
※Instantaneous contact (OUT2) will be returned when power is off.
※RESET key is locked for default set and release the lock to use.
K-33
LE4S Series
LE4SA Output Operation Mode Rt: Reset time (Min. 500ms)
[ ] T1 T2 Rt T1 T2
POWER
-
※RESET
contact (⑧-⑥)
contact (①-③)
POWER
Setting time T1 T1
T2
Star-Delta UP 0 contact
T1 T2
Setting time
(Output will be set DOWN
T2
0 contact
automatically
as Time limit 2c) 1. contact will be ON when power is ON and Timing operation starts.
2. contact will be OFF when timing operation is progressed up to the T1 setting time.
Timing operation will be reset and started again. ※T1: set time
3. contact will be ON when timing operation is progressed up to the T2 switching time.
Display value will be HOLD. T2: switching time
4. If pressing RESET key, display value and - contacts will be reset. ( - switching time)
5. It is able to set each T1 and T2 time separately.
[ ] T1 T2 Rt T1 T2 T1
POWER
T
※RESET
T1 contact (⑧-⑥)
T2 contact (①-③)
POWER
Setting time T1 T1
Twin T2
UP 0 T1 contact
Setting time T1 T2
(Output will be set T2
automatically DOWN 0 T2 contact
as Time limit 2c) T1, T2 = set time
1. T1 contact will be ON when power is ON and Timing operation starts.
2. T1 contact will be OFF and T2 contact will be ON when timing operation is progressed up to the T1 setting
time. Timing operation will be reset and started again. T2 contact will be OFF when timing operation is
progressed up to the T2 setting time. Display value will be HOLD. Enables to set T1 and T2
3. If pressing RESET key, display value and T1, T2 contacts will be reset. time same or differently
4. It is able to set each T1 and T2 time separately.
[ ] T1 T2 Ta Rt T1 T2
POWER
TⅠ
※RESET
T1 contact (⑧-⑥)
T2 contact (①-③)
※Initial status: UP mode-display value is "0", output is "OFF". DOWN mode-display value is "setting time", output is "OFF".
※Instantaneous contact (OUT2) will be returned when power is off.
※RESET key is locked for default set and release the lock to use.
K-34
LCD Timer(Touch Type)
Proper Usage (A)
Photoelectric
Sensors
Caution When connecting more than 2 timers with 1 relay contact
It may give an electric shock if touch the input signal for input or transistor, please wire following <Fig. 2 >. (B)
Fiber
terminal (Between START, RESET, INHIBIT and terminal Please use relay contact or transistor to start. Optic
Sensors
②) when the power is supplied. (Time error can occurs under 100ms setting because of
rising time of Timer). (C)
Door/Area
Power connection Sensors
● LE4S, LE4SA work stably within range of rated power. RESET ④ Power
Input contact (E)
(If using power line with another high voltage line or or transistor INHIBIT ① Pressure
Sensors
energy line in the same conduit, it may cause inductive
voltage. (F)
Therefore please use separate conduit for power line) LE4S
Rotary
Encoders
Short-
Power start circuit
current START ③ (G)
● Caution for power rising time (100ms) after power on and RESET ④
Connectors/
Sockets
power falling time (100ms) after power off. INHIBIT ①
(H)
Temperature
Power ON Controllers
OFF
100ms The unstable time 100ms
(I)
against the input signal SSRs / Power
LE4S Controllers
Graphic/
● Please use Power supply with over current protection Logic
Panels
circuit. (250V 1A fuse)
● When using relay contact as input signal, please use a (S)
Field
contact that can function reliable at 5VDC, 1mA. Network
Devices
● In case of connecting START terminal (③) and power Rectification Transformer
terminal (②) of LE4S, do not use it to start at the same circuit with isolation (T)
Software
time applying power. < External sensor power supply >
● LE4S is transformer less type, therefore please check
following for connecting relay contact for input signal and ●Be sure that the specifications of this unit. Because
transistor. when supplying the power to LE4SA, this unit operates
instantly. (If supplying the power without the right
checking, it may cause malfunction.)
● , , operation modes are available to set
as "0".
K-35
LE4S Series
Interval mode
It is able to make Instantaneous ON and time limit OFF
(Holding device) with using interval mode.
T: Timer
Instan-
START START
taneous
Time
limit
Time
limit
Noise
We test 2kV, pulse width 1㎲ against Impulse voltage
between power terminals and 1kV, pulse width 1㎲ at noise
simulator against external noise voltage. Please install MP
condenser (0.1 to 1㎌) or oil condenser between power
terminals when over impulse noise voltage occurs.
Environment
Please avoid the following places;
● Place where the unit may be damaged by strong impact
or vibration.
● Place where there is corrosive gas or flammable gas and
water, oil, dust exist.
● Place where magnetic and electrical noise occurs.
● Place where there is high temperature and humidity
beyond rated specification.
● Place where there is strong alkalis and acids.
● Place where there is direct ray of sun.
K-36