Professional Documents
Culture Documents
2-Elektroden-Ableiter
Nom. DC spark-over voltage VsdcN 90 230 300 350 400 1000 2000 V
@ 100 V/µs 99% of < 400 < 600 < 700 < 800 < 800 < 1700 < 3400 V
measured values
@ 100 V/µs typical values < 330 < 550 < 600 < 700 < 750 < 1600 < 3200 V
@ 1 kV/µs 99% of < 600 < 700 < 800 < 900 < 900 < 1900 < 4100 V
measured values
@ 1 kV/µs typical values < 530 < 650 < 700 < 800 < 850 < 1800 < 3800 V
Service life
3 operations 8/20 µs – – – – – 2 2 kA
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
© EPCOS AG 2017 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. 37
2-Electrode Arresters
2-Elektroden-Ableiter
@ 100 V/µs 99% of < 3300 < 3800 < 4350 < 5000 < 5200 V
measured values
@ 100 V/µs typical < 3000 < 3400 < 4150 < 4600 < 4800 V
values
@ 1 kV/µs 99% of < 3400 < 4000 < 4500 < 5400 < 5500 V
measured values
@ 1 kV/µs typical < 3100 < 3500 < 4300 < 4800 < 5000 V
values
Service life
1 operation 8/20 µs 5 5 5 5 5 kA
3 operation 8/20 µs 3 3 3 3 3 kA
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
38 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. © EPCOS AG 2017
2-Electrode Arresters
2-Elektroden-Ableiter
Light-duty types
5 kA / 5 A l 5.7 × 5 × 5 mm
S50-… / EIA case size 2220 / Metric 5750
Recommended
pad outline
Service life
10 operations 50 Hz, 1 s 5 5 A
10 operations 8/20 µs 5 5 kA
1)
1 operation 8/20 μs 10 10 kA
1)
After loading DC breakdown may exceed initial values but device will remain in a safe mode.
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
© EPCOS AG 2017 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. 39
2-Electrode Arresters
2-Elektroden-Ableiter
Light-duty types
5 kA / 5 A l ø 5 × 5 mm
M50-… M51-…
@ 100 V/µs 99% of < 350 < 550 < 550 < 800 < 1350 V
measured values
@ 100 V/µs typical values < 300 < 500 < 500 < 750 < 1200 V
@ 1 kV/µs 99% of < 650 < 600 < 650 < 900 < 1500 V
measured values
@ 1 kV/µs typical values < 550 < 550 < 600 < 800 < 1350 V
Service life
10 operations 50 Hz, 1 s 5 5 5 5 5 A
10 operations 8/20 µs 5 5 5 5 5 kA
1)
1 operation 8/20 μs 10 10 10 10 10 kA
1)
After loading DC breakdown may exceed initial values but device will remain in a safe mode.
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
40 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. © EPCOS AG 2017
2-Electrode Arresters
2-Elektroden-Ableiter
Light-duty types
5 kA / 5 A l ø 8 × 6 mm
EC…
@ 100 V/µs 99% of < 500 < 500 < 500 < 550 < 800 < 1200 V
measured values
@ 100 V/µs typical values < 400 < 450 < 450 < 500 < 700 < 1000 V
@ 1 kV/µs 99% of < 700 < 600 < 650 < 700 < 900 < 1300 V
measured values
@ 1 kV/µs typical values < 600 < 550 < 550 < 600 < 800 < 1100 V
Service life
10 operations 50 Hz, 1 s 5 5 5 5 5 10 A
10 operations 8/20 µs 5 5 5 5 5 5 kA
1 operation 8/20 µs 10 10 10 10 10 10 kA
1 operation 10/350 µs 1 1 1 1 1 1 kA
Capacitance @ 1 MHz < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 pF
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
© EPCOS AG 2017 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. 41
2-Electrode Arresters
2-Elektroden-Ableiter
Medium-duty types
10 kA / 10 A l ø 8 × 6 mm
N80-… N81-…
@ 100 V/µs 99% of < 500 < 500 < 700 < 900 < 1100 V
measured values
@ 100 V/µs typical values < 450 < 450 < 650 < 750 < 950 V
@ 1 kV/µs 99% of < 600 < 700 < 900 < 1100 < 1400 V
measured values
@ 1 kV/µs typical values < 550 < 600 < 800 < 900 < 1100 V
Service life
10 operations 50 Hz, 1 s 10 10 10 10 10 A
10 operations 8/20 µs 10 10 10 10 10 kA
1 operation 8/20 µs 12 12 12 12 12 kA
1 operation 10/350 µs 1 1 1 1 1 kA
Capacitance @ 1 MHz < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 pF
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
42 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. © EPCOS AG 2017
2-Electrode Arresters
2-Elektroden-Ableiter
Heavy-duty types
20 kA / 20 A l 6 × 8.4 × 8.4 mm
S80-…
Recommended
pad outline
@ 100 V/µs typical values < 300 < 450 < 450 V
Service life
10 operations 50 Hz, 1 s 20 20 20 A
10 operations 8/20 µs 20 20 20 kA
1 operation 8/20 µs 25 25 25 kA
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
© EPCOS AG 2017 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. 43
2-Electrode Arresters
2-Elektroden-Ableiter
Heavy-duty types
20 kA / 20 A l ø 8 × 6 mm
A80-… A81-…
@ 100 V/µs 99% of < 350 < 500 < 500 < 550 < 700 < 1100 V
measured values
@ 100 V/µs typical values < 300 < 450 < 450 < 500 < 650 < 950 V
@ 1 kV/µs 99% of < 650 < 600 < 650 < 700 < 900 < 1400 V
measured values
@ 1 kV/µs typical values < 600 < 550 < 550 < 650 < 800 < 1100 V
Service life
10 operations 50 Hz, 1 s 20 20 20 20 20 20 A
10 operations 8/20 µs 20 20 20 20 20 20 kA
1 operation 8/20 µs 25 25 25 25 25 25 kA
Capacitance @ 1 MHz < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 pF
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
44 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. © EPCOS AG 2017
2-Electrode Arresters
2-Elektroden-Ableiter
Heavy-duty types
20 kA / 20 A l ø 8 × 20 mm
A83-…
@ 100 V/µs 99% of < 500 < 600 < 650 < 550 < 700 < 1100 V
measured values
@ 100 V/µs typical values < 450 < 450 < 500 < 450 < 650 < 950 V
@ 1 kV/µs 99% of < 600 < 800 < 800 < 700 < 800 < 1400 V
measured values
@ 1 kV/µs typical values < 550 < 600 < 600 < 550 < 700 < 1100 V
Service life
10 operations 50 Hz, 1 s 20 20 20 20 20 20 A
10 operations 8/20 µs 20 20 20 20 20 20 kA
1 operation 8/20 µs 25 25 25 25 25 25 kA
Capacitance @ 1 MHz < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 pF
Dimensions in mm
About packing see page 83.
Please read Important notes on page 4 and Cautions and warnings on page 5.
© EPCOS AG 2017 Bitte beachten Sie die Seite 4 Wichtige Hinweise sowie die Warn- und Sicherheitshinweise auf Seite 5. 45