Professional Documents
Culture Documents
Printer and printhead mountings for the Linx 8900 Series CIJ printer
for the Linx 8900 Series CIJ printer
Printhead mountings
Linx offers a wide range of mounting Applications requiring orientation at Accurate printhead positioning Interchangeable parts to create customised structures.
accessories for positioning printers non-standard angles can be easily
and printheads onto production lines. accommodated. All parts are interchangeable, making it easy to custom-build printhead support
Many mounting options structures and modify them when required.
Printer mountings comprise robust Unique to the range is a relocating
stainless steel cabinets and tables, mechanism that enables the printhead
which can be moved easily, as required. to be returned exactly to its original Well designed parts are quick and
Printhead bracket, Handscrew clamp
position after routine maintenance. easy to assemble and install
adjustable – pole mount (printhead bracket)
The Linx range of printhead mountings This avoids lengthy downtime and FA62047 FA67056
offers one of the most versatile means rejected product created by laborious This bracket allows the printhead to be Can be fitted to the printhead bracket
of mounting close to the product to trial and error methods of resetting the Wide range of interchangeable adjusted from horizontal to vertical and adjustable – pole mount FA62047 to
be marked. The range incorporates a provides for the mounting of an M18 enable manual fastening without the use
printhead position. parts to meet current and future bodied product sensor and a fibre optic of a hexagonal key. This allows more
number of unique design features that requirements sensor. A printhead cover tube sleeve convenient adjustment of printhead
improve performance and minimise The range of mountings includes ensures correct replacement of the mounting assemblies while in use on
downtime during routine maintenance. predefined mounting assemblies. The printhead after cleaning. For mounting the production line. Can be ordered
A variety of head mounting accessories individual parts are fully interchangeable, on the end of a pole. separately or as a printhead bracket
Made of stainless steel and other
handscrew pole mount assembly
is available to suit individual customer allowing customers to create their own tough materials for durability Dimensions (mm): 50 H x 58 W x 152 D FA62066.
applications. application specific arrangements.
2 3
Printer and printhead mountings
Printer and printhead mountings for the Linx 8900 Series CIJ printer
Printer and printhead mountings for the Linx 8900 Series CIJ printer
for the Linx 8900 Series CIJ printer
Base – direct horizontal
mount
Cross joint
FA62048
Standard printhead mounting assemblies
FA62050 Allows two poles to be mounted firmly These are packs containing the parts necessary for the most common
To mount a pole onto a vibration-free, and securely at right angles to each printhead mounting positions.
horizontal mounting surface on the other by means of a hexagonal key.
production line. Complete with M6 The height of the printhead mounting bracket can be adjusted manually (via the
Dimensions (mm): 100 L x 50 D
fittings. cross joint), and its orientation varied between horizontal and vertical. A printhead
Dimensions (mm): 60 H x 90 W x 50 D wash station can be added for convenient printhead cleaning. These assemblies can
be modified easily if required by adding new parts.
4 5
Product sensors for the
On any production line it is vital that • Photocells and inductive switches Wide range of sensors to detect
Sensor type Background suppression Colour registration mark Through beam fibre-optic Reflective fibre-optic
on-line printers are correctly and to sense a wide range of products different types of product
sensor scanner sensor sensor
consistently triggered to print a high including very small objects and those FA61079 FA61078 FA63069 FA536002
quality message in the right place at with highly reflective surfaces Operating principle Infra red light reflected off a Visible light reflected off Product breaks a visible light Product reflects visible light
the right time. Poorly placed or partly Tested with Linx printers – meet E.U. product in the area of focus small areas of the product beam carried by fibre-optic carried by fibre-optic cables
missing codes may result in products • Specialised sensors to detect and U.S. EMC standards cables from a control unit from a control unit
registration marks and products that Application Where the background is Detects small registration For use in inaccessible places For use in inaccessible places
being rejected. likely to interfere with printed onto continuous rolls and to scan small items or and to scan small items
contrast poorly with the background. triggering, for example of packaging film and labels, items with only a small gap
Photocells and other sensors are simple Robust designs – protected to IP65 ridged conveyors or products including very small marks between them
All Linx sensors are robust, with full that contrast poorly with the moving at high speed. Detects
and reliable devices that can be used or above background black and colour marks
with a printer to achieve this consistency, screening, EMC compliance, a high Sensing range 90 – 105 mm 9 – 12 mm (adjustable) Up to 250 mm (adjustable) Up to 50 mm (adjustable)
thereby maximising coding efficiency. degree of environmental protection Material M18 Nickel plated brass Rectangular diecast zinc Control unit: Rectangular polycarbonate housing
(minimum IP65) and short-circuit proof Fitted connectors – ready to install body and nuts enclosure Fibre-optic cables: Polyethylene coated plastic fibres
The Linx range of product sensors transistor outputs. Environmental IP67 IP67 IP67 IP67
protection rating
supports coding of products of different
Dimensions (mm) 93 x 18 (dia) 66 x 42 x 15 Control unit: 39 x 31 x 13 Control unit: 39 x 31 x 13
sizes, colours and materials: Mounting brackets for convenient Fibre-optic end fittings: M4 Fibre-optic end fitting: M6
installation Ambient temperature -10°C to 60°C -10°C to 60°C -10°C to 60°C -10°C to 60°C
range (operational)
Speed of response 0.2 msec 0.3 msec 0.5 msec 0.5 msec
Cable length 5 m 5 m Electrical cable: 5 m Electrical cable: 5 m
Fibre-optic cables: 2 m Fibre-optic cables: 2 m
Product sensors
Compatibility with FA099050 Use of through holes in the body
(can be cut on site)
DIN-rail mount or surface
(can be cut on site)
DIN-rail mount or surface
mounting brackets or the bracket supplied gives mount using the bracket mount using the bracket
a variety of mounting options supplied supplied
Other information Plastic lens Light / dark switching Minimum bend radius of Minimum bend radius of
selected by wiring fibre-optic cables: 9mm fibre-optic cables: 9mm
Mounting brackets
Sensor mounting bracket Sensor cover tube
Sensor type Reflection light beam Retro-reflective light beam Inductive proximity switch FA099050 mounting bracket
scanner switch with polarisation filter FA61100 To mount M18 bodied sensors onto FA62035
FA61105 FA61108 the printhead bracket or other suitable Simple acetal bracket that clamps
Operating principle Infra-red light reflected by Product breaks light beam Electromagnetic induction surface on the production line. Can be directly onto the Linx printhead cover
the product rotated in two different planes to get the tube and allows M18 bodied sensors
Application General-purpose Shiny, reflective products such Ferrous and non-ferrous metals, best orientation of the sensor. to be positioned immediately adjacent
as glass bottles and foil trays for example cans to the printhead.
Sensing range 20 – 170 mm (adjustable) 100 – 1000 mm 3 – 9 mm
Material M18 chromium plated brass Rectangular re-inforced M18 chromium plated brass Dimensions (mm): 149 x 58 x 13
body and nuts plastic body body and nuts
Environmental protection rating
Dimensions (mm)
IP65
56 x 18 (dia)
IP67
38 x 18 x 13
IP67
60 x 18 (dia)
Sensor accessories
Ambient temperature range -10ºC to 60°C -10ºC to 60°C -10ºC to 60°C
(operational) Splitter box PDEM cable
Speed of response 1 msec 0.5 msec 2 msec FA63012 FA63040
Cable length 5 m 5 m 5m
The splitter box allows one product This cable enables printers to be
Compatibility with mounting FA099050 Bracket supplied for production FA099050 sensor and one encoder to be daisy-chained together so that one
brackets FA62035 line mounting FA62035
connected to up to 4 printers. product sensor can drive up to
Other information Plastic lens Plastic lens 8 printers, and one shaft encoder
Supplied with reflector
Light / dark switching selected can drive up to 4 printers.
by wiring
6 7
Shaft encoders for the
8 9
Alarms and RS232 communications
Alarms and RS232 communications for the Linx 8900 Series CIJ printer
for the Linx 8900 Series CIJ printer
Upgrade description and RS232 and RS232 and RS232 and Parallel input/
ordering number VFC multistage alarm 24V multistage alarm output
FA11214 FA11216 FA11213
Linx offers single-stage alarms as
standard accessories, and volt-free
Linx standard alarms Physical Connection(s) RS232: 9-pin ‘D’ type plug RS232: 9-pin ‘D’ type plug RS232: 9 Pin ‘D’ type plug
contacts that can be added to the The flashing light can be used to Multi stage VFC (Volt Free contact): Multi stage 24V: 7-pin Bulgin plug, Parallel input output: 25-way ‘D’ type
indicate any one of a number of printer 6-pin Bulgin plug, includes alarm includes alarm input connector plug
Linx 8900 printer for customer input connector
conditions, for example low ink or sol-
alarms.
vent levels and disabled print. Electrical connections and signals -15V,+15V RS232 protocol -15V,+15V RS232 protocol -15V,+15V RS232 protocol
RS232 is a legacy technology replaced All alarms feature: Four VFCs (Volt Free Contacts) Four 24V 200mA outputs which Eight outputs and inputs, in 6
by USB and Ethernet. Linx offers an • Flashing frequency: switched with connections ‘Common’, can be set to pulsed or continuous standard configurations. For
twice per second (2 Hz) 3 x ‘Normally open, 2 x ‘Normally triggered by printer events configuration details see Linx 8900
RS232 connection on the 8900 printer • IP55 rated closed’ which are triggered by a Series Operating Manual
as an accessory to connect to legacy printer status
They are compatible with the same
systems. Typical applications RS232 remote communications RS232 remote communications RS232 remote communications
Linx poles used to support printheads using SCP (Simple Communications using SCP (Simple Communications using SCP (Simple Communications
and wash stations. Protocol) or RCI (Remote Protocol) or RCI (Remote Protocol) or RCI (Remote
Communications Interface) Communications Interface) Communications Interface)
Pole mount alarm beacon
Volt free contact 3 stage switched 24V three stage alarm, linked to Integration of printer with production
FA64006 alarm, linked to 3 different printer 3 different printer statuses such as line PLC controllers
statuses, such as ‘Printing’, ‘Printer ‘printing’, ‘not printing’, ‘low fluids’
Audio/Visual alarm failure’, ‘Low fluids’, ‘Power up’
FA64017 Software requirements To enable RS232 after fitting To enable RS232 after fitting To enable RS232 after fitting
hardware. Order free of charge hardware. Order free of charge hardware. Order free of charge
Extra cable tidies to secure configuration code H-8-0-306-00 configuration code H-8-0-306-00 configuration code H-8-0-306-00
alarm cables to poles System Software 2.1.0 and above System Software 2.1.0 and above System Software 2.1.0 and above
FA62059
Spare alarm lens cover
FA71083 Upgrade description and RS232 and Parallel input/ RS232 and Parallel input/ Parallel input/output, with
ordering number output, with VFC multistage output, with 24V multistage 24V and Volt Free Contacts
alarm alarm multistage alarms
FA11217 FA11218 FA11219
Linx 8900 Alarm and IO (Input Output) accessories Physical Connection(s) RS232: 9 Pin D-type plug RS232: 9 Pin D-type plug Parallel input output: 25-way ‘D’ type
plug
Parallel input output: 25-way ‘D’ type Parallel input output: 25-way ‘D’ type
plug plug Multi stage VFC (Volt Free Contact):
Upgrade description and Single stage 24V single RS232 RS232 and VFC connection 15-way ‘D’ type plug
Multi stage VFC (Volt Free Contact): Multi stage 24V: 7-pin Bulgin plug,
ordering number stage alarm is standard with FA11206 FA11207 6-pin Bulgin plug, includes alarm includes alarm input connector Multi stage 24V: 7-pin Bulgin plug,
all printers input connector includes alarm input connector
Physical Connection(s) Alarm: 2-pin Bulgin plug. Primary RS232: 9-pin ‘D’ type plug RS232: 9-pin ‘D’ type plug Electrical connections and signals --15V,+15V RS232 protocol -15V,+15V RS232 protocol Eight outputs and inputs, in 6
use is with Linx single stage alarms. standard configurations. For
A 2-way Bulgin connector is also Single stage VFC (Volt Free contact) Eight outputs and inputs, in 6 Eight outputs and inputs, in 6 configuration details see Linx 8900
available, order FA69007 2-way output is 6-pin Bulgin plug, includes standard configurations. For standard configurations. For Series Operating Manual
Alarm connector alarm input connector configuration details see Linx 8900 configuration details see Linx 8900
Series Operating Manual Series Operating Manual Output is a 15-way ‘D’ type connector
Electrical connections and signals 24V, 0V, pulsed or constant -15V,+15V RS232 protocol -15V,+15V RS232 protocol with four 24V 200mA outputs which
Four VFCs (Volt Free Contacts) Four 24V 200mA outputs which can be set to pulsed or continuous
VFC (Volt Free Contact) switched switched with connections ‘Common’, can be set to pulsed or continuous triggered by printer events for
with connections ‘Common’, ‘Normally 3 x ‘Normally open, 2 x ‘Normally triggered by printer events example ‘not printing’
open’ and ‘Normally closed’, plus closed’ which are triggered by a
relay N.O.Off standard alarms printer status Four VFCs (Volt Free Contacts)
switched with connections ‘Common’,
Typical applications Single stage alarm driven by a RS232 remote communications RS232 remote communications 3 x ‘Normally open’, 2 x ‘Normally
printer status like ‘low fluids’ using SCP (Simple Communications using SCP (Simple Communications closed’ which are triggered by a
Protocol) or RCI (Remote Protocol) or RCI (Remote printer status
Communications Interface) Communications Interface)
Typical applications RS232 remote communications RS232 remote communications Integration of printer with production
Volt free contact mains powered using SCP (Simple Communications using SCP (Simple Communications line PLC controllers
single stage alarm linked to a printer Protocol) or RCI (Remote Protocol) or RCI (Remote
status, for example ‘printing active’ Communications Interface) Communications Interface) Three stage 24v alarm, linked to 3
different printer events
Software requirements All releases of system software To enable RS232 after fitting To enable RS232 after fitting Integration of printer with production Integration of printer with production
hardware. Order free of charge hardware. order free of charge line PLC controllers line PLC controllers Volt free contact 3 stage switched
configuration code H-8-0-306-00 configuration code H-8-0-306-00. alarm, linked to 3 different printer
Volt free contact 3 stage switched 24V three stage alarm, linked to statuses, such as ‘Printing’, ‘Printer
All releases of system software alarm, linked to 3 different printer 3 different printer statuses such as failure’, ‘Low fluids’, ‘Power up’
statuses, such as ‘Printing’, ‘Printer ‘printing’, ‘not printing’, ‘low fluids’
failure’, ‘Low fluids’, ‘Power up’
Software requirements To enable RS232 after fitting To enable RS232 after fitting System Software 2.1.0 and above
hardware. Order free of charge hardware. Order free of charge
configuration code H-8-0-306-00 configuration code H-8-0-306-00
System Software 2.1.0 and above System Software 2.1.0 and above
10 11
Air knives for the
Linx 8900 Series CIJ printer
If the product to be coded is wet or damp, an air knife Air knife kit
connected to factory air and positioned before marking FA74276
can dry the area enough to allow good ink adhesion.
Spare air nozzle
Linx air knives are easily attached to the printhead at the FA72163
optimal position for efficient drying.
These scanners are from a world-class manufacturer and Power supply for 1D/2D
are useful for QuickSwitch® and similar applications. barcode scanner
FA63073
Use of Linx scanners guarantees compatibility with Linx
Spare PSU requires c8 connector with
software and hardware, and will be given technical support
country specific plug.
by Linx.
2D USB scanner
FA63071
These scanners read all standard
Scanner wall/
barcode formats. Contact Linx technical desk holder
support for compatibility with specific FA62581
applications and code formats.
www.linxglobal.com
MP41216/3
For more information, contact Linx Printing Technologies Ltd, Linx House, 8 Stocks Bridge Way, Compass Point Business Park, St Ives, Cambs, PE27 5JL, UK.
Telephone +44 (0)1480 302100 Fax +44 (0)1480 302116 email sales@linx.co.uk www.linxglobal.com
Linx and QuickSwitch are registered trademarks of Linx Printing Technologies Ltd.
© Linx Printing Technologies Ltd 2017.